Medium Voltage Controllers, 200/400A Two-High Cabinet, Standard and Arc-Resistant Enclosure



Similar documents
Application Technique. Safety Function: Magnetic Door Switch Monitoring

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Oil and Coolant Circulating Heating System. Model - OCSM

Hard Disk Drive (HDD)

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Contractors Guide Central Inverter System Installation

CENTERLINE 2100 Low Voltage Motor Control Centers

CompactLogix Power Supplies Specifications

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

MCR1900 Media Converter 19-Slot Chassis

Medium Voltage Motor Control Assemblies

INTRODUCTION INTERLOCK KIT K-8110

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Sample - No Commercial Use

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

ControlNet Standard and High-flex Coax Cable

LIEBERT VNSA Installation Sheet

Masterclad 5 15 kv Arc Resistant Metal-Clad Indoor Switchgear

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Packaged Terminal Air Conditioner Wall Sleeve Installation

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

5800 Temperature Sensor Cable Assembly

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

HP UPS R1500 Generation 3

WE-350 Series ¼ Turn Electric Actuator

42U/45U 28" Wide Rack Installation & Service Guide

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Uninterruptible Power Supply. 500 kva kva

MCC Ratings. Voltage Rating

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

PS6500 Storage Arrays Rack Mount Instructions

Your safety and the safety of others are very important.

How To Build A Germany Power Plant

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ATS Overhead Table Shelf System INSTRUCTION MANUAL

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

INSTALLATION INSTRUCTIONS

Enhancing Personnel Safety with Arc Resistant Equipment

Type GM-SG-AR 5 kv and 15 kv arc-resistant metal-clad switchgear instruction manual. Answers for energy.

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

UV100A Ultraviolet Air Treatment System

Installation Instructions

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Installation Instructions

About the BitStorm 6051 POTS Splitter

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Parallel Redundant Uninterruptible Power Supply

ReadyLift (Part# ) Strut Extension, Installation Instructions Toyota Tundra New Body Style 2WD & 4WD

Control Box Wiring For PRSstandard Tool

Requirements for Electrical Installations

Installation Instructions for Alarm Module Kit A043F059

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Explosion-Proof Electric Unit Heaters

UniStream CPU-for-Panel

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Single Phase Soft Starter

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

SB-C-CTS/10TW3 SKU# & Up Cadillac CTS/CTS-V

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

INSTALL/REMOVAL INSTRUCTIONS: WINDOW LIFT MOTOR

Architect/Contractor Information Package

Cooktop Low-Profile Ventilation Hoods

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Owner s Manual & Safety Instructions

, User s Manual

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

G670 Intermittent Pilot Ignition Controls

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Toroidal Conductivity Sensor

Bimetallic Overload Relay Specifications

Installation Instructions

Medium voltage VCP-W MR2 (integral racking)

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

HMI display Installation Guide

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Model 1756 Test Lead Kit

ADM1TE 5/30A DIN rail single phase two wire energy meter

Transcription:

User Manual Medium Voltage Controllers, 200/400A Two-High Cabinet, Standard and Arc-Resistant Enclosure Publication 1500-UM055H-EN-P

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Rockwell Software, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Summary of Changes This manual contains new and updated information. New and Updated Information This table contains the changes made to this revision. Topic Page Replaced inside front cover. Inside Front Cover Replaced Typical Structure and Typical Nameplate graphics. 10 Added Environmental Conditions. 11 Replaced Center Vertical Channel graphic. 20 Updated procedure for Opening the Medium Voltage Doors. 30 Added step to procedure for Joining Sections. 32 Added information to Attention table. 39 Added information to Attention table. 42 Added information to Attention table. 43 Replaced Typical Ground Bus Splicing Configuration graphic. 47 Updated Isolation Switch Kit and stocking quantity. 79 Added (Series R or higher) to 80158-707-53 79 Added Attention table. 90 Added instructions to Cabinet preparation. 90 Added Attention table. 99 Added instructions to Cabinet preparation. 99 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 3

Summary of Changes Notes: 4 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Table of Contents Chapter 1 General Information Document Scope................................................... 9 Starter Identification............................................... 9 Prepared Space................................................... 11 Series Number............................................... 11 Motor Data.................................................. 11 Starter Features.............................................. 11 Recommended Torque Values.................................... 11 Environmental Conditions....................................... 11 High Altitude Application.................................... 12 Chapter 2 Installation Standard Enclosure Door Opening Procedure......................................... 13 Opening the Low Voltage Doors............................... 13 Opening the Medium Voltage Doors........................... 14 Anchoring....................................................... 15 Joining Sections.................................................. 16 Access to the Power Bus.......................................... 17 Rear Access.................................................. 17 Side Access................................................... 19 Front Access Access to Power Bus............................ 19 Front Access Bottom Exiting Load Cables.................... 24 Load Cable Connections......................................... 25 Top Exiting Load Cables...................................... 27 Bottom Exiting Load Cables.................................. 28 Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Door Opening Procedure......................................... 29 Opening the Low Voltage Doors............................... 29 Opening the Medium Voltage Doors........................... 30 Anchoring....................................................... 31 Joining Sections.................................................. 32 Access to the Power Bus.......................................... 33 Rear Access.................................................. 34 Side Access................................................... 34 Front Access Access to Power Bus............................ 36 Front Access Bottom Exiting Load Cables.................... 39 Load Cable Connections......................................... 40 Top Exiting Load Cables...................................... 41 Bottom Exiting Load Cables.................................. 42 Chapter 4 Common Installation Bus Splicing..................................................... 45 Power Bus................................................... 45 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 5

Table of Contents Insulated Power Bus Splicing.................................. 46 Ground Bus.................................................. 47 Incoming Line Cable Connections................................. 47 Installation of Current Transformer Barrier........................ 49 Hi-Pot and Megger Test.......................................... 49 Start-up Procedure............................................... 50 Contactor Inspection......................................... 50 Preliminary Checks........................................... 50 Testing Contactor Operation.................................. 51 Typical Wiring Diagrams......................................... 52 Chapter 5 Maintenance Tool Requirements............................................... 55 Recommended Torque Values..................................... 55 Door Interlock Circumvention.................................... 56 Power Lock-out Procedure........................................ 57 Fuse Removal and Replacement................................... 60 Bolt-on Fuse Removal/Installation............................. 61 Clip-on Fuse Removal/Installation............................. 61 Contactor Maintenance........................................... 62 Removing the Contactor.......................................... 62 Contactor Interlock Rod Adjustment.............................. 64 To Reduce the Gap Distance.................................. 65 To Increase the Gap Distance.................................. 65 Isolation Switch Mechanism Inspection and Lubrication............ 67 Isolation Blade Switch Adjustment................................ 69 Isolation Switch Mechanism Grounding Adjustment................ 72 Auxiliary Contacts Inspection and Replacement.................... 73 Isolation Switch Auxiliary Contacts................................ 74 Adjusting the Normally Open (ISa) Contacts................... 74 Adjusting the Normally Closed (ISb) Contacts.................. 75 Adjusting the Change-of-State Point........................... 76 Emergency Circumvention Procedure for Power Cell Entry.......... 76 Installing Z-clip with Isolation Switch Handle in the OFF Position.. 78 Installing Z-clip with Isolation Switch Handle in the ON Position 78 Chapter 6 Spare Parts Bulletin 1512 and 1512BT Units Parts List......................... 79 Appendix A ArcShield Unit Information Overview........................................................ 81 ArcShield Design................................................. 81 Exhaust Systems: Chimney or Plenum Option...................... 82 Plenum Information.......................................... 82 Plenum Exhaust Considerations............................... 83 6 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Table of Contents Additional Notes............................................. 85 Chimney Information........................................ 86 Chimney Exhaust Considerations............................. 86 ArcShield Plenum Installation Instructions ArcShield Chimney Installation Instructions Appendix B Recommended Torque Values.................................... 87 Plenum Bracing.................................................. 87 General Plenum Layout for ArcShield Line-up..................... 88 STEP 1 Mounting a Single Plenum.............................. 89 Cabinet Preparation.......................................... 90 Plenum Placement on Structure............................... 90 STEP 2 Alignment of Side-by-Side Plenums.................... 91 STEP 3 Sequence of Final Assembly............................. 92 STEP 4 Closing the Front of the Plenum Sections................ 93 STEP 5 Extension and Elbow Assembly.......................... 93 STEP 6 Mounting Extension/Elbow to Plenum Line-up......... 94 STEP 7 Additional Mounting Support........................... 96 Appendix C Recommended Torque Values.................................... 97 General Plenum Layout for ArcShield Line-up..................... 98 Cabinet Preparation.......................................... 99 Chimney Placement on Structure............................. 100 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 7

Table of Contents Notes: 8 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Chapter 1 General Information Document Scope This User Manual pertains to the Rockwell Automation Bulletin 1512B medium voltage controller. The Bulletin 1512B structure includes provisions for two complete MV controller units. The installation section provides instructions for both the standard enclosure type and Rockwell Automation arc resistant type (ArcShield). The product Bulletin numbers covered by this document are: 1512B 200/400 A FVNR controller 1512BT 200/400 A Transformer Feeder 1512BP 200/400 A Prepared Space (1) IMPORTANT This document is to be used for all Bulletin 1512B unit types, including arc resistant (ArcShield ) units. Important information specifically for ArcShield units can be found in Appendix A, Appendix B and Appendix C. ATTENTION: Users must refer to the information in Appendix A, Appendix B and Appendix C to correctly install and maintain ArcShield arc resistant units. Failure to do so may negate the arc resistant benefits provided by ArcShield, exposing personnel to risk of serious injury or death. This document may also be used as a reference guide for the following Bulletin numbers: 1512DM 200/400 A VFD Input Contactor Units 1512DO 200/400 A VFD Output Contactor units 1512M 200/400 A VFD Output Bypass Starter 1562E 200/400 A MV SMC Flex Solid-State (up to 4800V) Reduced Voltage Starter 1591B Incoming Line Unit 1592BF Fused Load Break Switch for Feeders 1592BP Fused Load Break Switch for Feeders, prepared space Starter Identification A structure nameplate is attached to the right-side flange of the structure (see Figure 1). Refer to the nameplate for information such as series number, section number, NEMA enclosure type, unit ratings and bus ratings. (1) Not available on arc-resistant designs. Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 9

Chapter 1 General Information Figure 1 - Typical Structure Nameplate A unit nameplate is also found in the low voltage compartment with specific unit motor application information (see Figure 2). Figure 2 - Typical Unit Nameplate Refer to these nameplates whenever you contact Rockwell Automation for assistance. Be prepared to provide such information as series number, structure series, unit series, diagram schematic and catalog number. 10 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

General Information Chapter 1 Prepared Space When ordering a starter kit to complete a prepared space (2), provide the following information to ensure the proper components are supplied. Series Number Provide the series number from the structure with the prepared space. The number is stamped on a nameplate on the right-hand flange of the starter (see Figure 1). The series number is also available from the dimension drawings for the starter. Motor Data Provide the following motor data: Locked rotor current Full load current Maximum locked rotor time Acceleration time Motor service factor Motor horsepower Starter Features Provide information regarding any special features required for the starter kit. Indicate if these features are different from the motor control features in the existing, complete power cell. Recommended Torque Values When reinstalling components or when reassembling the cabinet, tighten the following bolt sizes to the specified torque values: Table 1 - Hardware Torque Values 1/4 in. hardware 8 N m (6 lb ft) 5/16 in. hardware 15 N m (12 lb ft) 3/8 in. hardware 27 N m (20 lb ft) 1/2 in. hardware 65 N m (48 lb ft) Environmental Conditions The controller must accept nominal plant power of 2400V, 3300V, 4200V, 4800V, 5500V, 6600V, 6900V (+5/-15%), or 7200 (+0/-15%), 3 phase 50/60 Hz (± 3%). (2) Not available on arc resistant cabinets. Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 11

Chapter 1 General Information The standard controller must operate in an ambient temperature range of 0 40 C (32 104 F) with a relative humidity of up to 95% (non-condensing). Higher ambient temperature conditions are supported with factory assistance. The equipment shall be capable of being stored in an environment with an ambient temperature range of -40...85 C (-40...185 F). If storage temperature fluctuates or if humidity exceeds 85%, space heaters must be used to prevent condensation. The equipment must be stored in a heated building having adequate air circulation. WARNING: The equipment should never be stored outside. Rockwell Automation products are built using materials that comply with Class 1: Industrial Clean Air sulfur environments as defined in IEC Standard 60654-4 (Operating Conditions for Industrial-Process Measurement and Control Equipment), and G1 as defined in ISO-S71.04-1985 (Environmental Conditions for Process Measurement and Control Systems: Airborne Contaminants). High Altitude Application The equipment shall operate at altitudes from 0 1000 m (0 3300 ft) above sea level, without derating. For applications above 1000 m (3300 ft), the maximum current and basic impulse levels (BIL) of the controllers shall be derated, and vacuum contactors may be compensated for operation at the specified altitude (see publication 1500-SR020_-EN-P). 12 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Chapter 2 Installation Standard Enclosure IMPORTANT For information on the installation site preparation, see General Handling Procedures for MV Products, Publication MV-QS050_-EN-P. ATTENTION: Use suitable personal protective equipment (PPE) per local codes or regulations. Failure to do so may result in severe burns, injury or death. Door Opening Procedure Opening the Low Voltage Doors Low voltage doors are identified as LV in Figure 3. 1. To access the compartments for standard cabinets use a flat-head screwdriver and turn both of the 1/4-turn fasteners at least 90 in a counterclockwise direction. 2. The door is now released and will swing open. 3. Reverse the procedure to secure the doors. Figure 3 - Access to Low Voltage Compartments.. 1/4-turn fasteners for Upper Low Voltage Door LV MV.... 1/4-turn fasteners for Lower Low Voltage Door LV MV.. Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 13

Chapter 2 Installation Standard Enclosure Opening the Medium Voltage Doors ATTENTION: Medium voltage components are located behind the swing-out low voltage panel (standard cabinets only). Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) before attempting to open the swing-out low voltage panel. Failure to do so may result in severe burns, injury or death. ATTENTION: Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) before beginning any service procedures to the unit. Failure to do so may result in severe burns, injury or death. Medium voltage doors are identified as MV in Figure 4. Figure 4 - Access to Medium Voltage Compartments.. LV MV Door Locking Bolts for Upper Medium Voltage Door Isolation Switch Handles.... LV MV Door Locking Bolts for Upper Medium Voltage Door.. IMPORTANT Each medium voltage door has its own isolation switch handle and interlocking safeguards. Upper and lower power cells are separated by an isolation barrier. Refer to Access to the Power Bus on page 17 for the procedure to open the swingout low voltage panel behind the low voltage door (for standard cabinet only). 1. Electrically open the contactor by pressing the STOP button on the starter or at the remote control location. 2. Move the isolation switch handle to the OFF position. 3. Unscrew the door locking bolts for medium voltage door. 4. The door is now released and will swing open. 14 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 5. Reverse the procedure to close the door. IMPORTANT Ensure that the swing-out low voltage panel is in its original position before attempting to close the MV door. When closing the medium voltage door, ensure all door locking bolts on the right side of the MV door are in place and tightened until the door is flush with the flange. Do not overtighten the bolts. If the door is not securely fastened, it will not be possible to move the isolation switch handle to the ON position. ATTENTION: Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) before beginning any service procedures to the unit. Failure to do so may result in severe burns, injury or death. Anchoring Place the controller in the desired installation location. Use M12 (1/2 in.) floor mounting bolts to securely fasten the controller to the mounting surface. See Figure 5 as an example of the location of the mounting holes in the cabinet. TIP Refer to Dimension Drawing provided with order documentation for additional details related to cabinet floor plan. IMPORTANT Pre-determined cabinets have been designed for Uniform Building Code (UBC) seismic zone 1, 2A, 2B, 3 and 4, and IBC (International Building Code) seismic activity without overturning or lateral movement, provided they are securely mounted according to UBC, IBC and local building codes. This can include concrete pad design, steel floor design and the sizing of cabinet anchors. Concrete floor cutouts must not be adjacent to floor anchor bolts and must be sized to seismic load. Consult factory if floor mounting must be reviewed by an accredited engineer. Many jurisdictions require an engineer from the local area to review the design. Seismic qualification does not indicate that the equipment will function properly after a seismic event. Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 15

Chapter 2 Installation Standard Enclosure Figure 5 - Cabinet Floor Plan Line cable conduit opening. Load cable conduit opening for bottom compartment. Load cable conduit opening for top compartment. Control wire conduit opening. Each opening provides access to top and bottom compartments. Mounting holes for 1/2 in. (M12) anchor bolts. Mounting holes for 1/2 in. (M12) anchor bolts (required for seismic applications only). Minimum distance to concrete floor cut-out required for seismic applications. 1.00 (25) x 3.00 (76) non removable sill channels. Front All dimensions in. (mm) NOTES FOR SEISMIC APPLICATIONS For installations on concrete the minimum depth and radius of concrete supporting the cabinet anchors is dependent on seismic loads. Refer to important information above. For installations on a metal structure the metal plate depth and cabinet anchoring method is dependent on seismic loads. Joining Sections TIP Joining hardware can be found in a package mounted on the front of the shipping skid. Refer to publication MV-QS050_-EN-P for level floor surface requirements. 1. Position the left side of the section on a level surface and secure the section in place with 12 mm (1/2 in. [M12]) floor mounting bolts (refer to Anchoring on page 15). 2. When joining NEMA Type 12, apply a continuous 3 mm (1/8 in.) wide bead of silicone sealer around the perimeter of one section. 3. Remove the side bus access covers if applicable. 4. Position the right section against the left section. Ensure that the surface is level. 16 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 5. Secure the sections together using the 1/4-20 self-tapping screws. Thread the screw through the 7 mm (0.281 in.) clearance hole to the corresponding 6 mm (0.219 in.) pilot hole. To access the front clearance holes of the left-side cabinet, open the medium voltage doors. To access the rear clearance holes remove the rear covers of the starter. If rear access is not available, refer to Front Access Access to Power Bus on page 19. 6. Secure the right section to the floor using M12 (1/2 in.) floor mounting bolts (refer to Anchoring on page 15). Figure 6 - Joining Sections Side Bus Access Cover 0.219 Pilot Holes (5x) 0.281 Pilot Holes (5x) 0.281 Pilot Holes (5x) 0.219 Pilot Holes (3x) Front Front Access to the Power Bus ATTENTION: This procedure requires contact with medium voltage components. To avoid shock hazards, lock out incoming power before working on the equipment (refer to Power Lock-out Procedure on page 57 of Chapter 5). Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. Rear Access 1. Remove the hardware securing the center rear bus access cover (see Figure 7). 2. Remove the center rear bus access cover. Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 17

Chapter 2 Installation Standard Enclosure 3. Once the rear bus cover is removed, you will see the three power bus bars and the ground bus bar (see Figure 8). Figure 7 - Access to Power Bus from Side and Rear of Cabinet Center Rear Bus Access Cover Side Bus Access Cover Figure 8 - Bus Bars from Back Access 18 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 Side Access A side bus access cover is located on each side of the controller. 1. Remove the hardware from the appropriate side bus access cover (see Figure 7). 2. Remove the side bus access cover. 3. Once the side bus access cover is removed, you will see the three power bus bars and the ground bus (see Figure 9). Figure 9 - Side Bus Access Cover Removed Front Access Access to Power Bus ATTENTION: To avoid shock hazards, lock out incoming power (refer to Power Lock-out Procedure on page 57 of Chapter 5) before working on the equipment. Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. 1. Complete the Power Lock-out Procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) for both medium voltage power cells and the power bus. 2. Open the doors and remove the hinge pins. Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 19

Chapter 2 Installation Standard Enclosure 3. Open the low voltage cell doors (refer to Opening the Low Voltage Doors on page 13). 4. Disconnect the control wiring harness from the wire plug at the lower left side of the contactor. 5. Remove the two self-tapping screws from the center vertical channel (see Figure 10). 6. Pull on the center vertical channel to swing out the low voltage panel. Figure 10 - Center Vertical Channel Remove self-tapping screws from center vertical channel Control Wiring Harness 20 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 7. Remove each glass-polyester barrier located in front of the current transformers (see Figure 11). Figure 11 - Removing Glass-polyester Barrier Current Transformers Remove self-tapping screws from barrier assembly Glass-polyester barrier 8. Remove the retaining screw from the cable duct barrier and remove the barrier (see Figure 12). 9. Remove the two retaining screws from the cable duct boot and remove the boot (see Figure 12). Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 21

Chapter 2 Installation Standard Enclosure Figure 12 - Removing Cable Duct Boot and Barrier Current Transformers CT Mounting Plate Loosen Retaining Screws Cable Duct Boot Remove Retaining Screws Cable Duct Barrier 10. To access the left side of the power bus, locate the two bus access covers at the rear, left side of the power cell. Remove the four self-tapping screws from each cover and remove the covers (see Figure 13). Figure 13 - Removing Bus Access Covers Remove four selftapping screws from each Bus Access Cover 22 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 11. If access to the right side of the power bus is required, remove the vacuum contactor from the upper power cell (refer to Removing the Contactor on page 62 of Chapter 5). 12. Remove the power fuses from the isolation switch. 13. Remove the interphase barriers from the trailer fuse block by raising them vertically up and out of the mounting slots (see Figure 14). 14. Use a 9/16-in. socket to remove the contactor bus bars from the isolation switch trainer fuse block. Figure 14 - Contactor Bus Bars (Trailer Fuse Block for Clip-on Fuses Shown) Trailer Fuse Block Mounting Bolts Contactor Bus Bars 15. Disconnect the secondary control wiring from the control power transformer (CPT) and remove the CPT mounting plate. Leave the CPT attached to the plate. ATTENTION: The CPT is heavy and assistance may be required to safely remove and transport the unit. Use caution when removing the CPT. Failure to do so may result in personal injury and/or damage to the equipment. 16. To access the right side of the power bus, remove the self-tapping screws from the lower glass-polyester bus access cover and remove the cover (see Figure 15). Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 23

Chapter 2 Installation Standard Enclosure 17. Reverse the procedure to reassemble the cabinet. Ensure that the barriers are put back in place and all parts and tools are accounted for. Figure 15 - Access to Right Side of Power Bus Remove self-tapping screws ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so may result in electrical faults and cause damage to equipment or serious injury to personnel. Front Access Bottom Exiting Load Cables If the cables in your cabinet exit from the bottom, the procedure to access the power bus is almost identical to the one above. Follow the procedure for Top Exiting Load Cables on page 27, but remove the cable duct barrier and cable duct boot from the top of the lower power cell, rather than those at the bottom (see Figure 16). 24 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 Figure 16 - Bottom Cable Exit Configuration Cable Duct Barrier Cable Duct Boot Load Cable Connections ATTENTION: To avoid shock hazards, lock out incoming power (refer to Power Lock-out Procedure on page 57 of Chapter 5) before working on the equipment. Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. IMPORTANT The current transformers may be positioned for top or bottom cable exit. Follow the appropriate procedure described for your starter configuration. IMPORTANT Refer to Dimensional Drawings provided with order documentation for additional details. 1. Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5). 2. Open the MV power cell door. 3. Remove the cable duct boot at the top of the cabinet for top exiting load cables, or remove the one at the bottom of the cabinet for bottom exiting load cables (see Figure 17). Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 25

Chapter 2 Installation Standard Enclosure Figure 17 - Access to Load Cable Conduit Openings (Top exit cable configuration shown) (LV panels removed for clarity) Remove Cable Duct Boot to access Load Cable Conduit opening for cables exiting from bottom Power Cell Current Transformer Mounting Plate Connect Load Cables to Current Transformers 4. Remove the appropriate load cable conduit openings in the top or bottom of the cabinet (see Figure 18 or Figure 19). TIP Refer to Dimensional Drawings provided with order documentation for additional details. 26 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Installation Standard Enclosure Chapter 2 Top Exiting Load Cables 5. Load cables for the bottom power cell should be routed first. Pull the cables into the cabinet through the appropriate opening (see Figure 18). Run the cables behind the current transformer mounting plate and into the bottom power cell. Figure 18 - Load Cable Conduit Openings (Top Exit Shown) Top of Cabinet Load cable Conduit Opening for cables from top power cell Load Cable Conduit opening for cables from bottom power cell Ground Lug 6. For the top power cell, pull the cables into the cabinet through the appropriate opening (see Figure 18). 7. Connect the cables to the current transformers and tighten the connections to 65 N m (48 lb ft). 8. Connect cable shields to the ground lug. 9. Reinstall the cable duct boot and reassemble the cabinet. ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so may result in electrical faults and cause damage to equipment or serious injury to personnel. Rockwell Automation Publication 1500-UM055H-EN-P - December 2014 27

Chapter 2 Installation Standard Enclosure Bottom Exiting Load Cables TIP Follow steps 1-4 from the previous section. 5. Load cables for the top power cell should be routed first. Pull the cables into the cabinet through the appropriate opening (see Figure 19). Run the cables behind the current transformer mounting plate and into the top power cell. Figure 19 - Load Cable Conduit Openings (Bottom Exit Shown) Load Cable Conduit Opening for cables from top power cell Load Cable Conduit Opening for cables from bottom power cell Bottom of Cabinet 6. For the bottom power cell, pull the cables into the cabinet through the appropriate opening (see Figure 19). 7. Connect the cables to the current transformers and tighten the connections to 65 N m (48 lb ft). 8. Connect cable shields to the ground lug. 9. Reinstall the cable duct boot and reassemble the cabinet. ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so may result in electrical faults and cause damage to equipment or serious injury to personnel. 28 Rockwell Automation Publication 1500-UM055H-EN-P - December 2014

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) This installation section contains information on arc resistant styles of enclosures, referred to in this manual as ArcShield. IMPORTANT For information on the installation site preparation, see Publication MV-QS050_-EN-P. ATTENTION: Use suitable personal protective equipment (PPE) per local codes or regulations. Failure to do so may result in severe burns, injury or death. Door Opening Procedure Opening the Low Voltage Doors Low voltage doors are identified as LV in Figure 17 on page 26. 1. To access the compartments for ArcShield cabinets turn the release handle counter-clockwise 90º. 2. The door is now released and will swing open. 3. Reverse the procedure to secure the door. Figure 20 - Access to Low Voltage Compartments Chimney Plenum Upper Low Voltage Door handle LV MV LV MV Upper Low Voltage Door handle LV MV LV MV Lower Low Voltage Door handle Lower Low Voltage Door handle Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 29

. Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Opening the Medium Voltage Doors ATTENTION: Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) before beginning any service procedures to the unit. Failure to do so may result in severe burns, injury or death. Medium voltage doors are identified as MV in Figure 21. Figure 21 - Access to Medium Voltage Compartments Chimney Plenum Upper Low Voltage Door handle LV MV LV MV Upper Low Voltage Door handle Lower Low Voltage Door handle LV MV LV MV Lower Low Voltage Door handle IMPORTANT Each medium voltage door has its own isolation switch handle and interlocking safeguards. Upper and lower power cells are separated by an isolation barrier. Refer to Access to the Power Bus on page 33 for the procedure to open the swingout low voltage panel behind the low voltage door (for standard cabinet only). 1. Electrically open the contactor by pressing the STOP button on the starter or at the remote control location. 2. Move the isolation switch handle to the OFF position (see Figure 22). 3. Unbolt the door locking bolts for medium voltage door. 4. The door is now released and will swing open. 5. Reverse the procedure to close the door. Door lock bolts must be adequately tightened (refer to Recommended Torque Values on page 11 of Chapter 1 for torque values) IMPORTANT When closing the medium voltage door, ensure all door locking bolts on the right side of the MV door are in place and tightened until the door is flush with the flange. Do not overtighten the bolts. If the door is not securely fastened, it will not be possible to move the isolation switch handle to the ON position. 30 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 TIP On all ArcShield starters, the sticker in Figure 22 is attached to each door for your reference. Figure 22 - Label on Arc Resistant Door Anchoring Place the controller in the desired installation location. Use M12 (1/2 in.) floor mounting bolts to securely fasten the controller to the mounting surface. See Figure 23 as an example of the location of the mounting holes in the cabinet. TIP IMPORTANT Refer to Dimension Drawing provided with order documentation for additional details related to cabinet floor plan. Pre-determined cabinets have been designed for Uniform Building Code (UBC) seismic zone 1, 2A, 2B, 3 and 4, and IBC (International Building Code) seismic activity without overturning or lateral movement, provided they are securely mounted according to UBC, IBC and local building codes. This can include concrete pad design, steel floor design and the sizing of cabinet anchors. Concrete floor cutouts must not be adjacent to floor anchor bolts and must be sized to seismic load. Consult factory if floor mounting must be reviewed by an accredited engineer. Many jurisdictions require an engineer from the local area to review the design. Seismic qualification does not indicate that the equipment will function properly after a seismic event. ATTENTION: Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) before beginning any service procedures to the unit. Failure to do so may result in severe burns, injury or death. Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 31

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Figure 23 - Cabinet Floor Plan 7.50 [191] 5.25 [133] 4.88 [124] 13.05 [331] F E 16.17 [411] A 5.68 X 9.00 [144 X 229] 9.32 [237] 30.00 [762] 36.00 [914] G 4.62 [117] G E C B 5.68 X 9.00 [144 X 229] 5.68 X 9.00 [144 X 229] D 3.00 X 5.00 [76 X 127] H 23.68 [601] 2.31 [59] 31.38 [797] Front 36.00 [914] E A B C D Line cable conduit opening. Load cable conduit opening for bottom compartment. Load cable conduit opening for top compartment. Control wire conduit opening. Each opening provides access to top and bottom compartments. E F G H Mounting holes for 1/2 in. (M12) anchor bolts. Mounting holes for 1/2 in. (M12) anchor bolts (required for seismic applications only). Minimum distance to concrete floor cut-out required for seismic applications. 1.00 (25) x 3.00 (76) removable sill channels. NOTES FOR SEISMIC APPLICATIONS For installations on concrete the minimum depth and radius of concrete supporting the cabinet anchors is dependent on seismic loads. Refer to important information above. For installations on a metal structure the metal plate depth and cabinet anchoring method is dependent on seismic loads. Joining Sections TIP TIP Joining hardware can be found in a package mounted to the front of the shipping skid. Refer to publication MV-QS050_-EN-P for level floor surface requirements. 1. Position the left side section on a level surface and secure the section in place with M12 (1/2 in.) floor mounting bolts (refer to Anchoring on page 31). 2. When joining ArcShield sections, apply a continuous 3 mm (1/8 in.) wide bead of silicone sealer around the perimeter of one section. 3. Remove the side bus access covers if applicable. 32 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 4. Position the right section against the left section. Ensure that the surface is level. 5. Secure the sections together using the 1/4-20 self-tapping screws. Thread the screw through the 7 mm (0.281 in.) clearance hole to the corresponding 6 mm (0.219 in.) pilot hole. To access the front clearance holes of the left-side cabinet, open the medium voltage doors. To access the rear clearance holes remove the rear covers of the starter. If rear access is not available, refer to Front Access Access to Power Bus on page 19 of Chapter 2. When joining the ArcShield sections, use the provided 1/4-20 thread fasteners to secure the perimeter of the horizontal bus opening, ensure all bolts are installed. (Before joining sections together, ensure there is a silicone seal around the bus bar opening.) 6. Secure the right section to the floor using M12 (1/2 in.) floor mounting bolts (refer to Anchoring on page 31). IMPORTANT To prevent arc gas from escaping, all mounting holes on the sides and floor of the enclosure must have hardware installed. Figure 24 - Joining Sections Power Bus cutout holes must align Silicone is applied around power bus cutout area to prevent gas leakage between joined cabinets Access to the Power Bus ATTENTION: This procedure requires contact with medium voltage components. To avoid shock hazards, lock out incoming power before working on the equipment (refer to Power Lock-out Procedure on page 57 of Chapter 5). Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 33

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Rear Access 1. Remove the hardware securing the center rear bus access cover (see Figure 25). 2. Remove the center rear bus access cover. 3. Once the rear bus cover is removed you will see the three power bus bars and ground bus (see Figure 27). Figure 25 - Access to Power Bus from Side and Rear of Cabinet Side Bus Access Cover Center Rear Bus Access Cover Side Access A side bus access cover is located on each side of the controller. 1. Remove the hardware from the appropriate side bus access cover. 2. Remove the side bus access cover (see Figure 25). 3. ArcShield units at the end of a line-up have a ground connection to the inner plate of the side bus access cover (see Figure 26 to Figure 28). This connection must be maintained to ensure unit arc resistant performance. 34 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Figure 26 - Side Bus Access Cover Warning Label Figure 27 - Side Bus Access Cover Ground Connection Side Bus Access Cover Ground Connection Figure 28 - ArcShield Ground Plate Removable Handle Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 35

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Front Access Access to Power Bus ATTENTION: To avoid shock hazards, lock out incoming power (refer to Power Lock-out Procedure on page 57 of Chapter 5) before working on the equipment. Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. 1. Complete the Power Lock-out Procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5) for both Medium Voltage power cells and that power bar. 2. Open medium voltage power cell door (see Figure 29). Figure 29 - ArcShield Power Cell (Upper) 3. Remove the retaining screw from the cable duct barrier and remove the barrier (see Figure 30). 4. Remove the two retaining screws from the cable duct boot and remove the boot (see Figure 30). 36 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Figure 30 - Removing Cable Duct Boot and Barrier Current Transformers CT Mounting Plate Loosen Retaining Screws Cable Duct Boot Remove Retaining Screws Cable Duct Barrier 5. To access the left side of the power bus, locate the two bus access covers at the rear, left side of the power cell. Remove the four self-tapping screws from each cover and remove the covers (see Figure 7 on page 18). Figure 31 - Removing Bus Access Covers Remove Bus Access Cover Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 37

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) 6. If access to the right side of the power bus is required, remove the vacuum contactor from the upper power cell (refer to Removing the Contactor on page 62 of Chapter 5). 7. Remove the power fuses from the isolation switch. 8. Remove the interphase barriers from the trailer fuse block by raising them vertically up and out of the mounting slots (see Figure 32). 9. Use a 9/16-in. socket to remove the contactor bus bars from the isolation switch trainer fuse block. Figure 32 - Contactor Bus Bars (Trailer Fuse Block for Clip-on Fuses Shown) Trailer Fuse Block Mounting Bolts Contactor Bus Bars 10. Disconnect the secondary control wiring from the control power transformer (CPT) and remove the CPT mounting plate. Leave the CPT attached to the plate. ATTENTION: The CPT is heavy and assistance may be required to safely remove and transport the unit. Use caution when removing the CPT. Failure to do so may result in personal injury and/or damage to the equipment. 11. To access the right side of the power bus, remove the self-tapping screws from the lower glass-polyester bus access cover and remove the cover (see Figure 33). 12. Reverse the procedure to reassemble the cabinet. Ensure that the barriers are put back in place. 38 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Figure 33 - Access to Right Side of Power Bus Remove selftapping screws ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so will defeat the structure s arc resistant capabilities and result in electrical faults and cause damage to equipment or serious injury to personnel. Front Access Bottom Exiting Load Cables If the cables in your cabinet exit from the bottom, the procedure to access the power bus is almost identical to the one above. Follow the procedure for Front Access - Top Exiting Load Cables, but remove the cable duct barrier and cable duct boot from the top of the lower power cell, rather than those at the bottom (see Figure 34). Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 39

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Figure 34 - Bottom Cable Exit Configuration Cable Duct Barrier Cable Duct Boot Load Cable Connections ATTENTION: To avoid shock hazards, lock out incoming power (refer to Power Lock-out Procedure on page 57 of Chapter 5) before working on the equipment. Verify with a hot stick or appropriate voltage measuring device that all circuits are voltage free. Failure to do so may result in severe burns, injury or death. IMPORTANT The current transformers may be positioned for top or bottom cable exit. Follow the appropriate procedure described for your starter configuration. IMPORTANT For ArcShield units, cable size should not exceed 1-500 MCM or 2-350 MCM per phase. Note: Refer to Dimensional Drawings provided with order documentation for additional details related to cabinet floor plans. 1. Complete the Power Lock-out procedure (refer to Power Lock-out Procedure on page 57 of Chapter 5). 2. Follow steps 2 to 6 from Front Access Access to Power Bus on page 36 for the procedure to swing out the low voltage panel. 3. Remove the cable duct boot at the top of the cabinet for top exiting load cables, or remove the one at the bottom of the cabinet for bottom exiting load cables (see Figure 35). 40 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Figure 35 - Access to Load Cable Conduit Openings (Bottom Exit Cable) Connect Load Cables to Current Transformers Removable Cable Duct Boot to load cable conduit opening for cables exiting from bottom power cell 4. Remove the appropriate load cable conduit openings in the top or bottom of the cabinet (see Figure 36 or Figure 37). Top Exiting Load Cables TIP Follow steps 1-4 from previous section. 5. Load cables for the bottom power cell should be routed first. Pull the cables into the cabinet through the appropriate opening (see Figure 36). Run the cables behind the current transformer mounting plate and into the bottom power cell. 6. For the top power cell, pull the cables into the cabinet through the appropriate opening (see Figure 36). Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 41

Chapter 3 Installation Arc-Resistant Enclosure (ArcShield) Top of Cabinet Figure 36 - Load Cable Conduit Openings Load Cable Conduit Opening for Cables from Top Power Cell Load Cable Conduit Opening for Cables from Bottom Power Cell Current Transformer Mounting Plate 7. Connect the cables to the current transformers and tighten the connections to 65 N m (48 lb ft). 8. Connect cable shields to the ground lug. 9. Reinstall the cable duct boot and reassemble the cabinet. ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so will defeat the structure's arc resistant capabilities and result in electrical faults and cause damage to equipment or serious injury to personnel. Bottom Exiting Load Cables TIP Follow steps 1-4 from previous section. 5. Load cables for the top power cell should be routed first. Pull the cables into the cabinet through the appropriate opening (see Figure 37). Run the cables behind the current transformer mounting plate and into the top power cell. 42 Rockwell Automation Publication 1500-UM055H-EN-P - February 2015

Installation Arc-Resistant Enclosure (ArcShield) Chapter 3 Figure 37 - Load Cable Conduit Openings Load Cable Conduit Opening for cables from top power cell from behind the cable duct boot Load Cable Conduit Opening for cables from bottom power cell Bottom of Cabinet 6. For the bottom power cell, pull the cables into the cabinet through the appropriate opening (see Figure 37). 7. Connect the cables to the current transformers and tighten the connections to 65 N m (48 lb ft). 8. Connect cable shields to the ground lug. 9. Reinstall the cable duct boot and reassemble the cabinet. ATTENTION: Ensure all barriers are replaced before re-energizing the equipment. Failure to do so will defeat the structure's arc resistant capabilities and result in electrical faults and cause damage to equipment or serious injury to personnel. Rockwell Automation Publication 1500-UM055H-EN-P - February 2015 43