User and Fitting Manual September 2011. Electric Curtain Track System Silent Gliss 5090



Similar documents
LUCCI AIRFUSION QUEST II CEILING FAN

INFRARED QUARTZ WALL HEATER

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Drayton Digistat +2RF/+3RF

Portable Air Conditioner

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

INSTALLATION INSTRUCTIONS

Infrarot-Bewegungsmelder IP44

- 2 - IMPORTANT SAFETY REMINDERS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Written By: Sam Lionheart

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Service Guide. Gateway M275

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

5W LED Energy Saver PIR Bulkhead

SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ALARM SYSTEM INSTALLATION GUIDE

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Metropole System Silent Gliss 6130M with Vega. Silent Gliss Metropole Decorative Curtain Poles

Build Your Own Solar Car Teach build learn renewable Energy! Page 1 of 1

4.3-inch Back-Up Camera

Meaco 30L and Meaco 40L dehumidifier instruction manual

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

AerAtron. Ceiling fans

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Important Safeguards

Page 1. Description

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

WIRELESS HOME ALARM SYSTEM (WHA1)

24 Wide Screen LED Monitor with HDMI

Telis 4 Soliris RTS Operating and installation guide Ref A

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MFU200 Integrated Under Counter Larder Fridge

AM / FM Tuner + RDS. Model: TU

User Installation Guide

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Your Simple Guide to Battery. Replacement. Customer Care:

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Doorbell Intercom Security System

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

Instruction manual for Firstline FCS12000CH

Digital Photo Picture Frame. Operation Manual

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Single Day Alarm Clock with. Bluetooth and USB Play-through

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

EZ-Steer Assisted Steering System

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Control Box Wiring For PRSstandard Tool

INSTALLATION INSTRUCTIONS

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Wireless Home Security Alarm System AM 500

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Small form factor bay converter and hard drive installation

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

GSM Alarm System User Manual

AerAtron. Ceiling fans

LED Security Spotlight User Manual

Replacing the Gateway M675 Keyboard

How To Program An Autodialer

Written By: Walter Galan

5800 Temperature Sensor Cable Assembly

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Getting started with

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Original Assembly Guide

3 IN 1 BATHROOM HEATER

DAB+ / FM Tuner Model: TU-201

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225

FG MOISTURE MONITOR Installation & Operation Manual

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

MAINTENANCE & TROUBLESHOOTING

16/32 Channel 1U Rack Mount CCTV Power Supply

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

430 Power/Electronics Replacement

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

INTRODUCTION INTERLOCK KIT K-8110

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Stove Guard Kit User Manual

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Transcription:

User and Fitting Manual September 20 Electric Curtain Track System Silent Gliss 5090

Table of Contents Failure to observe the following instructions may invalidate the Silent Gliss warranty. Fitting Information 4 2 Silent Gliss 5090 Basic Operation Method: 9 With Switch 3 Option : Silent Gliss 5090IR 0 4 Option 2: Silent Gliss 5090TL 4 5 Option 3: Silent Gliss 5090TC 22 6 Problem Solver 23 Important: Before using your system Silent Gliss 5090, please read these instructions carefully and keep them safe for future reference. A few minutes spent familiarising yourself with these components will save you time when carrying out the installation.

Fitting Information. Deciding the best position Points to consider when planning your installation The system Silent Gliss 5090 may trigger some types of burglar alarm. This may usually be remedied by relocation of, or a change of burglar alarm sensor. If in doubt, consult your burglar alarm supplier. It may be easiest to have the power supply on the same side of the window as the nearest plug socket. You might choose to position the power supply so that it is not visible and not touchable. The transformer should not be placed where there is a risk of condensation dripping onto it from a window sill or used in damp environments such as bathrooms. When fixing avoid any hidden cabling in wall. If in doubt consult a qualified electrician. Tools for fixing Your system track is ready assembled for easy fixing. Your track pack contains everything you need to fix the track to a wooden batten. If fixing directly to a wall or ceiling, appropriate fixings; e.g. wall plugs will also be needed. Page 4 User and fitting Manual Silent Gliss 5090

Bracket position Draw a level line on the ceiling, wall or batten at the height you wish to position the track. Ask your supplier about the appropriate kind of bracket. Note: The distance* depends on the kind of curtain used. Check that nothing disturbs the curtain for example: radiator, window handle etc. 80-00* 53 Top fix with bracket 3825 Wall fix with bracket 3836.2 Fitting the motor Fitting the motor unit to the predetermined end of the track Slide back locking plate () and remove. Locate motor drive shaft (2) into pulley drive (3) inside pulley housing (5). Fully insert motor (4) into pulley housing (5) and twist to secure motor unit onto pulley housing as shown. Replace locking plate () to lock the motor firmly in position. Note: You may need to turn motor slightly to left or right to ensure locking plate locates completely with a click. To remove motor, if necessary, reverse instructions above. 5 2 4 3 User and fitting Manual Silent Gliss 5090 Page 5

.3 Fixing the hook tape to the transformer and the fixing plate to the wall Clean rear of transformer case, remove velcro hook strips from fixing plate (). Stick velcro hook strips in position centrally above and below the certification sticker on the rear of the transformer case (2) lining up with velcro loop section on the fixing plate. Position wall holder and mark through fixing lugs onto the wall. Drill fixing holes using a 6mm drill, insert wall plugs provided and screw fixing plate (3) to wall. In the event of the mains cable not reaching a convenient mains socket, we would advise you to have an additional socket fitted by a qualified electrician. Tidy the run of cable between the transformer and motor unit with the cable clips provided. When fixing avoid any hidden fixing cabling in the wall. If in doubt consult a qualified electrician 2 3.4 Connecting the motor Connect transformer to mains power with lead supplied (do not switch on power at this stage). Plug in transformer output into port () on the bottom of the motor. Black wheel (2) is channel for IR sensor (optional) see section 3. 2 Motor A B Plug A is for the cable of the timer or switch Plug B is for the infrared sensor or switch Transformer (with cable) Page 6 User and fitting Manual Silent Gliss 5090

.5 Fixing the switch Lever switch cover off switch using a flat bladed screwdriver near the cable. There are two options for fitting the cable of the switch. A. Concealed fitting the switch is supplied with cable entering from the back to allow concealment of cable. B. Surface fitting break off the blanking piece () from the edge of the switch backplate as shown allowing the cable to fit flush to the wall. Position the switch and mark through holes onto the wall (2). Drill fixing holes using a 6mm drill, insert wall plugs provided and screw switch to wall (3). Replace cover. Fix cable to wall with cable clips provided. Note: All cables are fitted with non-rewireable plugs and cannot be shortened. 2 3 Switch.6 Adding or removing gliders Single Stack: First remove the motor (see Fitting the Motor on previous page). Insert gliders through the slot. Pair Stack: On the opposite side of the motor, remove only the locking plate, there will be enough space to add or remove gliders. Note: When hanging your curtains the heading must be underslung i. e. the top of the curtains must be completely below the curtain track profile, failure to do so could invalidate the warranty. User and fitting Manual Silent Gliss 5090 Page 7

.7 Setting or adjusting the end stops Having hung your curtains to the track, you can now adjust the end stops if necessary. If required, you can control how far the curtains draw back by means of the end stop (). Carefully loosen end stop (2) locking screw. Slide the stop along the channel to the point that you want the curtains to dress to when open or close and then fully re-tighten screw. Re-test to the open position and re-adjust end stop (). Note: In order to avoid damage of the system, the belt carrier (3) must run into the end stop () on both sides. Single Stack factory set do not move 2 3 Pair Stack factory set do not move adjustable set to curtain fullness 3 Track adjustable set to curtain fullness Page 8 User and fitting Manual Silent Gliss 5090

2 Silent Gliss 5090 Basic Operation Method: With Switch Connecting motor The switch can now be plugged in to either position A or B. 2 Motor A B Operating your curtain track with switch Press switch» curtain moves Press switch during moving» curtain stops Press switch again» curtain moves back Switch User and fitting Manual Silent Gliss 5090 Page 9

3 Option : Silent Gliss 5090IR ) Motor 2) Switch 3) Infrared Sensor 4) Transformer 5) Main Plug 3 2 4 5 ) Remote control 2) Wall bracket 3) Self-adhesive cover 4) Sensor unit 5) Mounting clip - sensor 6) Cable - sensor 7) Plug B - sensor 8) Cable clips 6 4 7 8 5 3 2 Infrared Set IR SG 5093 Page 0 User and fitting Manual Silent Gliss 5090

3. Remote control The system can be conveniently operated from anywhere in the room using the remote control (Ideal for curtains that may be difficult to reach). Visible contact between sensor and remote control is necessary in order to dependably operate the system. A B 2 switch sensor Motor 3.2 Connecting motor and infrared sensor Unplug motor from mains. Plug the infrared sensor into the position B on the motor. Additionally, the switch could also be plugged into position A on the motor. (see Basic 5090 operation section 2) Decide where you wish to locate the sensor (4). It can be fixed to the wall by mounting clip (5) and screw (9) or clipped to a curtain by the mounting clip (5). The sensor should be in full view, not hidden behind the curtain or track. Attach the sensor (4) to the wall or curtain and secure cable with clips (8) provided. Note: The mounting clip (5) can be removed from the sensor (4) for fixing or adjusting the angle of the sensor. 9 5 4 8 IR Sensor User and fitting Manual Silent Gliss 5090 Page

3.3 Wall mounting the remote control You may wish to mount the remote handset () to a convenient wall near the door or close to a light switch. A wall mounting bracket (2) is provided for this purpose. Important: Do not attempt to fix mounting bracket where there is a possibility of hidden cables, e.g. directly above or below a light switch. If in doubt, consult a qualified electrician. To fit mounting bracket position, level and mark holes of mounting bracket (2). Drill two holes and insert wall plugs. Secure mounting bracket (2) to wall with screws provided. Attached self-adhesive cover (3) onto mounting bracket (2) to cover screw heads. The handset locate rest securely on this bracket but remains easily detachable for use anywhere in you room. 3 2 IR Remote Control Page 2 User and fitting Manual Silent Gliss 5090

3.4 Controlling more than one track You can use the handset to operate one or more systems by using the channel selector switch. There are four positions,,2,3 and 23(All). The motor is preset to receive all channels. If you have more than one system in the same room and you would like to operate them independently, you will need to set each motor to a separate channel as follows: Adjusting and testing the infrared system Channel selector switch Side view of the remote control 3 2 23 If you have just one track and no other infrared systems in your house, then the easiest way is to set the remote control to position 23(All). If you have more than one system and would like to control them separately, choose remote control position and turn the black wheel () with small flat blade screwdriver to position on the first motor. For the second motor, set the switch on the remote control to position 2 and turn the black wheel on the second motor to position 2. For the third motor, set the switch on the remote-control to position 3 and turn the black wheel (potentiometer) on the third motor to position 3. A B Motor User and fitting Manual Silent Gliss 5090 Page 3

4 Option 2: Silent Gliss 5090TL 4. Fixing the timer unit The timer unit is fixed to the wall by means of the fixing bracket (). When fixing, avoid any hidden cabling in the wall. If in doubt, consult a qualified electrician. Drill 6mm holes, insert wall plugs provided and screw wall bracket to wall. Before mounting the timer unit onto the bracket, plug the motor cable into position A and the light sensor into position C (see next page). You have the possibility to hide the cable on the rear side of the timer unit. Both cables could leave timer unit on the left or right side or one cable to the left and the other to the right, depending on where motor and light sensor are located. Rear of Timer C A Page 4 User and fitting Manual Silent Gliss 5090

4.2 Connecting motor & timer ) Unplug motor from mains. 2) Plug the timer unit cable into position A on the motor (). 3) Plug in the other side of the cable into position A on the timer unit (2). 4) Plug in the light sensor into position C on the timer unit (3). 5) Additionally, the switch could be plugged into position B on the motor. A B Motor 2 3 Timer User and fitting Manual Silent Gliss 5090 Page 5

4.3 Fixing the light sensor The light sensor should be positioned behind the curtains facing the window to detect changing levels of light. Different locations can affect the opening times of curtains as follows. - Sensor faced towards rising sun will open and close earlier. - Sensor faced towards setting sun will open and close later. - Angling the sensor away from the window into the room will open later and close earlier. Fix the light sensor to the window frame or inside the window reveal with the adhesive pad. Tidy the cable with cable clips to the timer unit. 4.4 Activating the timer unit To activate the timer unit turn on mains power. The display panel should now indicate a time of 2:00 hours. Now try the operation using the open-stop-closed buttons. ) Option button 2) Reset button 3) Display 4) Clock controls 5) Close 6) Stop 7) Open Timer Page 6 User and fitting Manual Silent Gliss 5090

Programming the timer unit When you plug in the timer Unit, it is factory set; Clock 2:00 Timer Open 09:00 Timer Close 9:00 Timer To set timer to the correct time: Press, a flashing clock will appear. Set time using or. Press when finished. To set timer opening: Press, a flashing open symbol and opening time will appear. You can now reset the opening time using the or controls. Press when finished. To set timer closing: Press, a flashing closed symbol and closing time, now show. You can now set the closing time, again using the or controls. Press when finished. This completes the setting procedure. Press until both symbols appear. Your timer is now set to operate for both open and closed operations. User and fitting Manual Silent Gliss 5090 Page 7

Continued Select your desired control method Press and the system will scroll trough the following options with each press of the button. Start point; timer operates for both open and close. Open on timer and close on light sensor (when fitted). Close on timer and open on light sensor (when fitted). Timer and light sensor not operational, switch control through switch on timer only. Light sensor operates both open and close (timer not activated). Page 8 User and fitting Manual Silent Gliss 5090

4.5 Light sensor adjustments Your unit is pre-set to switch at an average light intensity for both open and close. However, you may wish to adjust the light sensor level required to trigger the curtain operation. Using the option button select clock only. First mode (Dawn and Dusk) Now press and hold the following 2 buttons, and then all simultaneously. The number 50 shows up. The sensitivity is divided between and 00 for dark and bright. = The curtains will open with minimum of light. 00 = The operation requires brighter light to open the curtains. The first mode setting is common for both the open and close functions. To return to normal operation press button. Functional test of light sensor When in this part of the set-up procedure, the light sensor can be functionally tested and will respond immediately. Cover the light sensor and the curtains will close, uncover the sensor and the curtains will open. You can use the open-stop-close buttons at any time without affecting the automatic settings. The timer gets back to light mode after a 24 hour cycle. User and fitting Manual Silent Gliss 5090 Page 9

Second mode (Sun protection) In Sun protection mode the curtain will close in high levels of direct sunlight to control temperatures or protect room interiors. Now press and hold the following 2 buttons, and then all simultaneously. The number 50 shows up. By pressing the button long enough you get after 0 to 00. There you have to possibility to choose between 00 and -900. -00 = The curtains close with less light. -900 = The curtains close with direct sunshine into the sensor (bright sunlight) The first mode setting is common for both the open and close functions. To return to normal operation press button. The second mode works only on this display position. Note: Opening and closing times will vary with changing weather conditions. You can use the open-stop-close buttons at any time without affecting the automatic settings. The timer gets back to light mode after a 24 hour cycle. Page 20 User and fitting Manual Silent Gliss 5090

Reversing open-close direction Note: Depending on which way round you have chosen for your curtains to operate, you may find the open and close controls on the main control are reversed. To reverse the direction, proceed as follows: ) Set the curtains to half open / half closed (this is so that the system can run in either direction when the procedure is completed) 2) Disconnect the power plug from the motor unit. 3) Wait for 30 seconds to allow the capacitors in the motor unit to discharge 4) Press and hold a manual operating switch (note: this must be one of the simple switches, NOT the buttons on the timer unit) 5) Whilst still holding the switch, reconnect the power plug. 6) The motor will now run in the new open direction. 7) The switch can be released once the motor has started to run. The switch used for this setting can be connected into either position A or B on the motor. User and fitting Manual Silent Gliss 5090 Page 2

5 Option 3: Silent Gliss 5090TC The Silent Gliss 5090TC combines all control options from Silent Gliss 5090IR and 5090TL, for connection instructions please refer to sections 3 and 4. Please note the manual switch cannot be used if the light sensor is connected (switch included in kit). Page 22 User and fitting Manual Silent Gliss 5090

6 Problem Solver Problem Possible cause What to do Switch does a) Not plugged in at a) Check mains plug not operate mains or fuse blown or change fuse if curtain necessary b) Loose plugs b) Connect plugs into at motor unit motor unit c) Motor unit fault c) Refer to supplier Infra-red a) Battery in remote a) Change batteries does not flat on remote operate b) Infra-red sensor b) Plug Infrared sensor curtain is not connected into B on the motor unit c) Infrared sensor c) Reposition Infrared is covered sensor d) Not the same d) Change the frequency on the frequency on the remote and the motor remote to 23 (All) and try Timer unit not a) Timer unit not a) Press reset button functioning activated b) Not plugged in b) Plug in on position A timer unit and A motor unit Light sensor a) Light sensor or timer a) Plug Light sensor does not ope- unit not connected into C on timer unit, rate curtains plug timer unit A to motor unit A b) Sensitivity incorrectly b) Adjust setting adjusted Light closes a) Sensitivity incorrectly a) Turn sensitivity or open not adjusted adjuster on timer unit correctly b) Not correct daylight. b) Reposition Light User and fitting Manual Silent Gliss 5090 Page 23

6. Helpful Information Heat from the transformer Power consumption Maintenance Safety precautions Power cut The Silent Gliss 5090 transformer will feel slightly warm to touch. This is normal operating temperature and not a cause for concern. Silent Gliss 5090 is designed for minimal power consumption and is, therefore, inexpensive to run. In normal use, Silent Gliss 5090 will require no maintenance. There are no user-serviceable parts within the motor unit, timer unit or the transformer. If the supply cord becomes damaged it must only be replaced by the manufacturer, or its service agent, or a similarly qualified person in order to prevent a hazard. Do not exceed the maximum total curtain weight of 5 kg straight or 0 kg on a bent track. Timer settings will be retained for up to 48 hours in the event of a power cut. Page 24 User and fitting Manual Silent Gliss 5090

7 Warnings It is important for the safety of persons to follow these instructions. Save these instructions. Usage - Appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. - Children being supervised not to play with appliance. - Do not allow children to play with fixed controls. Keep remote controls away from children. - Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do not use if repair or adjustment is necessary. Installation - Before installing the drive, remove any unnecessary cords and disable any equipment not needed for powered operation. - Do not install the actuating member of a manual release at a height less than.8 m. - If a fixed control device is used, it must be mounted visibly - The used external power source, must be a safety insulated transformer or safety insulated power switching device with an output voltage of DC 24V and a minimum output current of,2a (ED2O% 5min). - If an external power source is used, a point of disconnection from the main power supply must be available or mains plug must be accessible. User and fitting Manual Silent Gliss 5090 Page 25

Page 26 User and fitting Manual Silent Gliss 5090

User and fitting Manual Silent Gliss 5090 Page 27

www.silentgliss.co.uk Silent Gliss Limited Pyramid Business Park, Poorhole Lane, Broadstairs, Kent CT0 2PT Tel: +44 (0) 843 86357 Fax: +44 (0) 843 864503 sales@silentgliss.co.uk