Pump-Transfer Cooler Filtration Unit UKF-3 / UF-3



Similar documents
Fixed displacement vane pumps

PUMP AND MOTOR DIVISION

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Filter Elements E /05.06

The Professional Choice. LDC With DC motor. OLAER LDC optimized for mobile use

Series TMM Axial Piston Motor. Technical Information

15/40/80CN Series Medium Pressure Filters

Radial piston pumps type R and RG

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Variable Displacement Pump AA10VSO

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Hydraulic Control Solutions

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

Rotary screw compressors kw 5,5 7, , bar MODULO

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

PVS Series - Models 185, 600, 1200, 1800 and 2700

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Refrigeration Compressed Air Dryer Buran Ultrapulse

Overheating limit control

Series description: Wilo-Drain TC 40

ThermoSorb Desiccant Dryers

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

ECOCIAT. Domestic hot water heat recovery unit

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Pressure transmitter For general industrial applications Model A-10

Internal gear pump PGF Series 2X and 3X

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

ETC -SV. Class 0 oil-free compressed air through catalysis

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Thermostatic valve Type AVTA

2/2 and 3/2 Way Size 6 Seat Valves

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Model 1210C Battery Powered Pump Shown. Description

300 Series PA Pump and Cooler Assemblies

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Energy Recovery Device isave 21-40


2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Breathers and Filler Breathers.

SOLENOID VALVES 3-4 WAY

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Pressure relief valves Size 6

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

How To Use A Corona Mdi 110

Rickmeier Solutions. Gear pumps for superior Lubrication

Chapter 5: Flow Valves

Single- and Multi-circuit Pumps

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

ThermoStar Refrigeration Air Dryers

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

912. The engine for construction equipment.

Duplex Filters 40 FLDK 0008(C)-0120(C)

Series PVP Variable Volume Piston Pumps

15/40/80CN Series Coreless Medium Pressure Filters

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Heating, air-conditioning, cooling

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Conlift1, Conlift2, Conlift2 ph+

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Technical Information. Hydrostatic Spindles. Hydrostatik by Hyprostatik. Innovative Spindle Concepts

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

MANTA Piston Distributor for Oil and Fluid Grease

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Pressure reducing valve, direct operated, Type ZDR 6 D

Axial Piston Variable Pump KVA

Specifications for Volkswagen Industrial Engine

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

HEERHUGOWAARD. T: +31 (0) Technical information

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Axial Piston Variable Motor A6VM

Transformer oil cooler ALFA A02

Overflow valve with thread connection

Transcription:

Pump-Transfer Cooler Filtration Unit UKF-3 / UF-3

Pump-transfer cooler filtration unit UKF-3/ UF-3 1. Description 1.1 General The UKF unit is a compact, easy-to-install unit for offline filtration cooling circuits. Installation is simply a matter of pipe mounting to and from the tank and connecting the voltage supply. 1.2 Features Offline unit consisting of: zlow-noise feed pump zfilter zoil-water plate heat exchanger zthe circuit is fitted with check valves to isolate the filter when used with a positive head tank when changing the filter element 1.3 Applications zplastic injection moulding machines ztransmission systems zpressing / Stamping zmachining centres zhydraulic systems 1.4 Hydraulic circuit UF (without heat exchanger) UKF optional optional 2. Technical specifications 2.1 Operating pressure Oil side max. 10 bar Water side max. 30 bar (static) 2.2 Suction pressure across the suction connection Max. 0.4 bar to 0.5 bar 2.3 Medium Oil side: Mineral oil to DIN51524 Part 1 and 2 Permitted contamination NAS 12 or ISO4406: 22/21/18 2.4 Temperature of medium Oil side: +10 C to +80 C Water side: +5 C to +60 C 2.5 Max. viscosity See Point 7. 2.6 Ambient temperature +10 C to +40 C 2.7 Mounting position Vertical 2.8 RPM Min. 1000 rpm Max. 1800 rpm 2.9 Direction of rotation Clockwise, see direction of arrow 2.10 Drive Three-phase electric motor Insulation class F Protection class IP55 2.11 Volumetric efficiency > 90 % at ν = 40 mm²/s 2.12 Noise levels Pump [cm³/rev] 1 bar 6 bar 20 61 61 30 61 62 40 62 63 50 64 66 70 67 68 100 68 70 130 70 72 db(a) at 1500 rpm Test medium ISO VG46 at 40 C. The noise levels are only a guide as the acoustic properties of a room, connections, viscosity and reflections have an effect on the noise level. 2.13 Weight (dry unit) (UF + heat exchanger + filter) UF: 1.5 kw 44 kg 2.2 kw 48 kg 4 kw 52 kg Heat exchanger: 610-20 11 kg 610-40 14 kg 610-70 17 kg 610-100 22 kg 610-120 25 kg 615-20 14 kg 615-40 18 kg 615-60 24 kg 615-80 30 kg Filter: MF180 2 kg LF330 5 kg LF500 7 kg LF660 8 kg 2.14 Operating data for heat exchanger zmedium (water side): Water glycol (HFC) Water Oils zcontamination: The level of particles in suspension should be less than 10 mg/l Particle size > 0.6 mm (spherical) Thread-like particles cause a rapid increase in pressure drops zcorrosion: The following limits correspond to a ph value of 7 Free chlorine: Cl 2 < 0.5 ppm Chloride ions: Cl < 700 ppm at 20 C; Cl < 200 ppm at 50 C Other limits: ph 7-10 2- Sulphate SO 4 < 100 ppm 2- [HCO 3 ] / [SO 4 ] > 1 Ammonia, NH 3 < 10 ppm Free CO < 10 ppm The following ions are not corrosive under normal conditions: Phosphate, nitrate, nitrite, iron, manganese, sodium, potassium zheat exchanger connections: Female thread (max. torque value 160 Nm) The pipes must be connected so that the connections are stressfree. Linear expansion and vibrations from the pipes to the heat exchanger must be avoided. 2

3. Model code (also order example) UKF-3 / 1.0 / P / 70 / 2.2 / 610-70 / LF330 / 10 / D Type UKF UF pump + heat exchanger + filter pump + filter Model 1.0 heat exchanger series 610 2.0 heat exchanger series 615 1.2 / 2.2 with filter bypass Seals P+V static seal Perbunan + dynamic seal Viton P static and dynamic seal Perbunan Pump flow rate: cm³/rev cm³/rev 1000 rpm 1500 rpm 20 20 l/min 30 l/min 30 30 l/min 45 l/min 40 40 l/min 60 l/min 50 50 l/min 75 l/min 60 60 l/min 90 l/min 70 70 l/min 105 l/min 100 100 l/min 150 l/min 130 130 l/min 185 l/min Motor 1.5 kw @ 1000 rpm 2.2 kw @ 1500 rpm 2.2-6p kw @ 1000 rpm (6 pole motor) 4 kw @ 1500 rpm 4-6p kw @ 1000 rpm (6 pole motor) Plate heat exchanger No. of plates Series 610-20 - 40-50 - 70-100 -120 Series 615-20 - 40-60 - 80 Filter MF 180 LF 330 LF 500 LF 660 Filtration rating -03 3 µm -05 5 µm -10 10 µm -20 20 µm For further details on filter elements, see Filtration Technology catalogue. Differential pressure clogging indicator 2 bar BM: VM 2 BM.1 (2 bar; visual; manual reset) C: VD 2 C.0 (2 bar; electrical) D: VM 3 D.0 / -L24 (3 bar; electrical/visual) Other indicators on request For further details: see Clogging Indicator brochure 3

4. Determining the cooling capacity of UKF 4.1 Estimating the cooling capacity requirement for mineral oil based on increase in tank temperature DT V 1 P= t 35 P = heat dissipation DT = temperature increase in tank V = tank volume T = operating time [kw] [K] [l] [min] Example: In a system the tank temperature increases from 20 C to 70 C (= 50 K) in 30 minutes. The tank volume is 100 l 50 100 1 P= 30 35 P= 4.8 [kw] 4.2 Estimating the cooling capacity requirement based on installed electrical power P ¼ installed electrical power Calculating the oil and water outlet temperature Drop in oil temperature: P DT 36 Q oil Increase in water temperature P DT 14.4 Q water P = cooling capacity [kw] Q = oil flow rate [l/min] oil Q = water water flow rate [l/min] A calculation program is available to calculate accurately the required cooling capacity and a suitable plate heat exchanger. For this, five of the following seven variables are required: Oil inlet and outlet temperature Oil flow rate Water inlet and outlet temperature Water flow rate Cooling capacity In addition, the viscosity of the oil is required. 5. Selection of the plate heat exchanger The following graphs show the selection of plate heat exchangers based on cooling capacity. 5.1 Cooling capacity Cooling capacity at 185 l/min Cooling capacity [kw] Cooling capacity [kw] Cooling capacity [kw] 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10 15 20 25 30 35 40 Water temperature [ C] Cooling capacity at 105 l/min 55.00 50.00 45.00 40.00 35.00 30.00 25.00 20.00 Water temperature [ C] Cooling capacity at 45 l/min 615-80 615-60 610-120 610-70 15.00 10 15 20 25 30 35 40 24.00 22.00 20.00 18.00 16.00 14.00 12.00 10.00 8.00 615-60 615-40 610-100 610-40 615-40 615-20 610-40 610-20 6.00 10 15 20 25 30 35 40 Operating condition: T oil = 55 C; oil ISO VG 46; Water temperature [ C] Q oil Q water = 4 4

6. Dimensions UKF-3 UF-3 5

7. Graphs for motor-pump selection Viscosity / Temperature Graph to DIN 51519 Viscosity index 50 Kinematic viscosity [mm²/s] Temperature [ C] 6

8. Filter selection Depending on the conditions of the system and the environment, filters with the same filtration rating perform differently. Typicall fluid cleanliness classes achieved with HYDAC elements are shown below: Filtration rating x ( β x(c) >= 200) 25 19/16/13-22/19/16 20 18/15/12-21/18/15 15 17/14/11-20/17/14 10 15/12/9-19/16/13 5 12/9/6-17/14/11 3 10/7/4-13/10/7 10. Note The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 10/7/4 11/8/5 12/9/6 13/10/7 14/11/8 15/12/9 16/13/10 17/14/11 18/15/12 19/16/13 20/17/14 21/18/15 22/19/16 9. Notes on installation The pressure differential in a hydraulic line is dependent on: zflow rate zkinematic viscosity zpipe dimensions and can be estimated for hydraulic oils as follows: l Dp = 5.84 Q n [bar] d 4 l = Pipe length [m] d = Pipe internal diameter [mm] Q = Flow rate [l/min] n = Kinematic viscosity [mm²/s] This applies to straight pipe runs and hydraulic oils, and to laminar flow. Additional threaded connections and pipe bends increase the pressure differential Note: zas few threaded connections as possible zfew pipe bends; if unavoidable, use large radius zdifference in height between pump and oil level as small as possible zhoses must be suitable for a vacuum of min. 5000 mmw zdo not reduce pipe cross-section predetermined by the unit Oil cleanliness to ISO 4406 7