APPLETON PLUGS AND RECEPTACLES TRUSTED CONNECTIONS.



Similar documents
D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Rugged & Reliable Power Connections

Plugs and Receptacles

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Title: Grounding and Bonding Rev-01

Charging what can be more simple? SAE J1772

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Generator DoCKInG StatIonS

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

RAY-MAX Integrated Solar Power Strip

Powertite Series Pin and Sleeve Receptacles, Connectors and Plugs

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

B-Series Temperature Switches

Bypass transfer switch mechanisms

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

Electrical Grounding. Appendix C

Utility Distribution Systems

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

12-Volt 10-Amp Regulated Power Supply

Explosion-Proof Electric Unit Heaters

The MC Cable Revolution is Gaining Ground REMKE

The Different Types of AC Power Connectors in North America

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

Vilter motor starter solutions The NEW industry standard in motor starter packages

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Construction Electrical Terminology. Electricians

Raceway and Boxes for Electrical Systems Page 1 of 7

IEC 309 INTERLOCKS NORTH AMERICAN

Electrocution Hazards

EDS / EFS Series Control Stations

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

PAINT BOOTH LIGHTING

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE

WHOLESALE DIRECT INC WEST 65TH STREET

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

EDS / EFS Series Control Stations

Protect your home and family with Advanced Technology from Cutler-Hammer

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

POWER GENERATION.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Evaluating Water-Damaged Electrical Equipment

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

The Different Types of AC Power Connectors in North America

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Fundamentals of Power

8146/5 Series Breaker Panelboards

HIGH VOLTAGE SHORE CONNECTION

Evaluating Water-Damaged Electrical Equipment

Screw Plug Immersion Heaters

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

THE IMPORTANCE OF HIPOT ISOLATION ON INDUSTRIAL ETHERNET SWITCHES

Plugs and Receptacles Industrial Heavy Duty Non-Hazardous

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Plugs & Receptacles. Section

D e s c r i p t i o n a n d De s i g n Fe a t u r e s

Laboratory Safety Guideline Electrical Safety

B-Series Switches Pressure, Differential Pressure & Hydraulic

Cable/Conduit Conversion

AMERBRITE UNDERWATER WHITE LED POOL LAMP

CHARGING SYSTEMS INTERNATIONAL

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

Secondary Unit Substations

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

Hazardous location controls and apparatus. Getting you closer. ACE series explosionproof variable frequency drives

Top Commercial / Residential Electrical Requirements *

TWIST-LOCK and HUBBELLOCK Devices

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

BATTERY CHARGER OWNER S MANUAL

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

The Tesla Roadster battery pack is comprised of about 6800 of these cells, and the entire pack has a mass of about 450kg.

RAEGuard EC FGM-13XX

For Models #6-5001, #6-7501, # & #10-12K1

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Neutral Wire Facts and Mythology. White Paper #21

Heading FACT SHEET. Overview.

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

POWER TO GET THE JOB DONE

Safety and Installation Instructions for AC Modules

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

RayClic Connection System Installation Instructions

3053 Electrical Safety Training Program Course Outline

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Transcription:

APPLETON PLUGS AND RECEPTACLES TRUSTED CONNECTIONS.

SUPPLYING POER HERE IT S NEEDED. The portable equipment used to build, repair, operate or maintain petrochemical plants, marine terminals, cell towers or even petroleum exploration equipment requires secure electrical connections. Achieving this safely requires Appleton plugs and receptacles. For over 100 years, we have given you the power to connect. Our single-minded goal is safety. e protect your personnel by designing plugs and receptacles with safe, reliable and secure connectivity. e make them watertight, dust ignition proof or explosionproof to keep your facilities as safe as possible. Indeed, many of our receptacles pass the rigorous NEMA 4X requirements. And when you consider that NEMA 3X is the industry standard, you begin to see just what kind of trusted connection you can expect from Appleton.

hether you need to bring power to a trade show booth, a metal grinder in a shipyard or to an arc welder in the middle of the Gulf of Mexico, Appleton has a plug and receptacle to fit your exact need. Appleton offers three families of plugs that work in unison with dozens of receptacle designs that make safe electrical connections in commercial, industrial, harsh and hazardous environments. Factor in the different amperage and voltage choices and features of our specialty receptacles, and you have hundreds of options to choose from. The Powertite Series, our metallic pin and sleeve offering, is designed to handle moisture, inclement weather, as well as hazardous vapor or dust. Typical applications include cellular communication infrastructure, ship to shore power, oil field equipment and portable equipment used in the petrochemical industry. All aluminum construction ensures durability in these difficult environments. atertight design provides protection against potential failure or shock hazard. Our U-Line blade style devices build out our vast product line. The robust plug design permits portable equipment to be used safely in both hazardous and standard location environments. Our IEC 309 pin and sleeve product is an economic solution that is great for use in non-hazardous, light industrial applications like warehousing, entertainment, and food processing plants. Locations where a nonmetallic solution is preferred. hether for general purpose or hazardous locations, our plug and receptacle products are designed to ensure maximum safety for the people who are connecting them. PLUG AND RECEPTACLE CLASSIFICATIONS G I Div.2 I Div.2 General eatherproof NEMA 3X NEMA 4X Class II Division 2 Class II Division 1 Class I Division 2 Class I Division 1 APPLETON CONNECTS IN ANY ENVIRONMENT. POERTITE U-LINE IEC 309 PIN AND SLEEVE

POERTITE SERIES Our workhorse line, and the basis for many of our plug and receptacle product systems, is the Powertite Series. Constructed of non-corrosive, copper-free aluminum, Powertite plugs and receptacles are built for use in locations where exposure to the elements is inevitable. hen certain applications require additional safety precautions, reverse service or contact rotation options are available. Pair it with one of our many receptacles, and the Powertite plug can create a trusted connection for a hazardous location. SR/SRD/MD2SR INTERLOCKED RECEPTACLES G Designed for use with Powertite plugs, these receptacles provide a service outlet for portable equipment in non-hazardous locations like paper processing plants and shipyards. The housing is available in cast aluminum, sheet metal or stainless steel to allow for the optimum choice for a given environment. Special features provide safety and convenience. For example, a worker has the ability to shut off power locally, thereby preventing arcing. Once energized, the plug cannot be accidentally disconnected by a worker. *Only with the factory sealed MD2SR receptacles. Div.2* JBR SERIES RECEPTACLES This Powertite configuration has an interlocked disconnect switch. It is smaller in size than the competition, making it easier to install. But don t be fooled by its compact size. The JBR Series is explosionproof and rated NEMA 4X. EBR SERIES RECEPTACLES SR Based on the JBR design, the EBR series offers overcurrent protection through the use of a circuit breaker that is accommodated by a slightly larger housing. The footprint, however, is still more compact than those of the competition. SRD DBR SERIES RECEPTACLES MD2SR I ith a circuit breaker housed inside, it is designed for hazardous conditions (Class II), and is ideally suited for locations like grain elevators. If hazardous dust is prevalent, rely on the DBR.

U-LINE /U-LINE GFCI SERIES Bringing power to portable electrical devices should not bring hazards along with it. ith U-Line receptacles, you have safety in design and convenience in function. The factory sealed switched receptacle is explosionproof and designed to keep out moisture and dust. A simple twist of the plug produces an audible click, indicating that the receptacle is energized and the plug cannot be pulled out accidentally. A spring-loaded cap adds additional protection when the plug is disengaged. hen operating portable electricallyoperated devices in wet conditions, rely on the U-Line GFCI to meet all of the UL and CSA requirements for ground fault protection in hazardous conditions. INTRAGROUND N1 AND N2 SERIES RECEPTACLES These non-metallic receptacles stand up to extremely corrosive locations like offshore oil rigs. The N1 Series is ideally suited for Division 1 applications, and it will stay dry internally under the toughest conditions. The N2 Series is for Division 2 environments and is factory sealed so no external seals are required. CPS RECEPTACLES Div.2 The quick Make/Break feature of these receptacles reduces the potential for arcing. Deeply recessed contacts decrease the danger of accidental touching and safely confine any possible arcing to the interior of the unit. ATERTIGHT PIN AND SLEEVE G These plugs and receptacles are the standard for nonmetallic industrial pin and sleeve devices. The housings are constructed of nylon and high-impact PBT for durability. The entire line is color-coded for quick and easy identification of voltage requirements. Spring-loaded lids and gaskets ensure watertightness in heavy hosedown situations.

Appleton is our premium line of industrial electrical products under EGS Electrical Group, a division of Emerson Industrial Automation. Emerson Industrial Automation brings integrated manufacturing solutions to diverse industries worldwide. Our comprehensive product line, extensive experience, world-class engineering and global presence enable us to implement solutions that give our customers the competitive edge. For over 150 years, our electrical product brands have been providing a rich tradition of long-term, practical, high quality solutions with applications ranging from the construction and safe operation of petrochemical and process plants to providing quality power that precisely controls automotive robotic production. Engineers, distributors, contractors, electricians and site maintenance professionals around the world trust Emerson Industrial Automation brands to make electrical installations safer, more productive and more reliable. EGS is organized into three focused businesses that provide distributors and end-users expert knowledge and excellent service. Electrical Construction Materials This group manufactures a broad range of electrical products including conduit and cable fittings, plugs and receptacles, enclosures and controls, conduit bodies, and industrial lighting. hether the application is hazardous location, industrial, or commercial, the ECM group has the products to meet your needs. Power Quality Solutions This group offers the broadest power quality line including UPS, power conditioners, voltage regulators, shielded transformers, surge suppression devices and power supplies. Heating Cable Systems This group offers a broad range of electri cal heating cable products for residential, commercial, and industrial applications. Electrical Construction Materials Power Quality Solutions Heating Cable Systems EGS Electrical Group 9377. Higgins Road Rosemont, IL 60018 1.800.621.1506 www.egseg.com Canada 888.765.2226 Asia/Pacifi c 65.6745.0114 Middle East 971.4.8838.831 Latin America 52.55.5366-6180 x125 China 86.21.54260668 x305 Europe 33.1.4817.8502 The Appleton, O-Z/Gedney, SolaHD, EasyHeat, Nelson and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2008, EGS Electrical Group, LLC. All rights reserved. Appleton\Brochures\Plugs_Receptacles\PlugsandReceptacles\AEC_PlugsReceptacles_Brochure.indd