SECTION 02563 SANITARY SEWER FORCE MAINS



Similar documents
SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

SECTION 603 SANITARY SEWER FORCE MAINS

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Special Specification 7021 Water Main and Sewer Line Replacements

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Chapter 7 Plumbing Connections

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

SECTION STORM DRAIN SYSTEM

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Section C-1 Pipes and Fittings

City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

SECTION DUCTILE-IRON PIPE AND FITTINGS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SECTION STORM DRAINAGE SYSTEM

SECTION PVC PRESSURE PIPE AWWA C900

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

STANDARD SPECIFICATION SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

ENGINEER S LIST OF APPROVED ITEMS POTABLE WATER SYSTEM

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

SECTION BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.

SECTION DUCTILE IRON PIPE AND FITTINGS

FY08 SEWER POINT REPAIRS BID TABULATION

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

For a building with a crawl space, see Figure

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

SECTION SANITARY SEWER PIPE

SECTION 3 SANITARY SEWER DESIGN

SANITARY SEWER SPECIFICATIONS

SECTION DUCTILE IRON PIPE AND FITTINGS

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

SECTION FIRE HYDRANTS

WATER SERVICE 2

INDEX. Sec. No. Items Page Nos.

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Standard Specifications for Installation and Repairs of Water and Sewer Service Lines

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION FACILITY STORM DRAINAGE PIPING

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

Item No. Description Estimated Unit Total Unit Total Unit Total Unit Total Quantity Price Amount Price Amount Price Amount Price Amount

SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2016

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

DIVISION 4300 STORM DRAINAGE

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

VILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER ST BID PROPOSAL

SECTION WATER DISTRIBUTION SYSTEMS TABLE OF CONTENTS

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Section 2100-Trenching and Tunneling

WILDCAT CANYON ROAD SPECIFICATION NO SLIDE REPAIR BIDDER'S PROPOSAL (continued)

Town House Center Highway North Huntingdon, PA 15642

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification GRAVITY SANITARY SEWER SYSTEM

APCO SLOW CLOSING AIR/VACUUM VALVES

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Technical Specifications For Sewing Enveilment Plans

Chapter 6 Material Specifications

CD i -STREETS- Detail #

STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF MANITOWOC, WISCONSIN SECTION 400 SEWER AND WATER CONSTRUCTION

Sewage Compliance Form Instructions

CHAPTER 6 - SANITARY SEWER

UFGS (January 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION STORM DRAINAGE TABLE OF CONTENTS

Wastewater Capital Projects Management Standard Construction Specification

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SUPPLEMENTAL SPECIFICATIONS AND DETAILS FOR CONSTRUCTION SEPTEMBER Metropolitan Domestic Water Improvement District P.0.

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Construction Standards for the City of Bristol, Tennessee. Adopted: January 8, 2002

STAFFORD COUNTY DEPARTMENT OF UTILITIES WATER AND SEWER

INSTALLATION OF INSITUFORM LINER

Acceptance Codes APPENDIX - A. Acceptance Criteria

ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION

CABLE TRENCH INSTALLATION GUIDE

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION CAST-IN-PLACE CONCRETE

SECTION 300 SANITARY SEWER CONSTRUCTION SPECIFICATIONS

CHAPTER 6 PIPELINE MATERIALS, VALVES AND APPURTENANCES

SECTION 200: STORM SEWER CONSTRUCTION STANDARDS

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Transcription:

SECTION 02563 SANITARY SEWER FORCE MAINS 1.0 GENERAL A. Description Sanitary sewer force main installation shall include, but not necessarily be limited to, furnishing and installing pressure rated pipe, fittings, and appurtenances of size and type shown on the Plans, installed on firm foundation true to line and grade and in accordance with the Contract Documents. B. Related Work Specified Elsewhere 1. Trench Excavation, Backfill, and Compaction; Section 02250. 2. Precast Concrete Utility Structures; Section 03400. C. Quality Assurance 1. Materials 2.0 MATERIALS The Commission will inspect all materials before, during and after installation to ensure compliance with the Contract Documents. 1. Materials shall be furnished in accordance with the Contract Documents. 2. To minimize the number of joints, only standard manufacturers length of pipe shall be furnished and installed for all sanitary sewer force mains and house connections unless otherwise indicated on the plans, or as approved by the Commission. B. Pipe Symbols For convenience and standardization, the various types of pipe are designated on the plans by the symbols noted in Section 02551, entitled Water Main Installation and Chlorination. C. Materials Furnished by the Commission 1. The Commission will not furnish any materials for sanitary sewer force main construction. 2. Unless otherwise noted in the Special Provisions, the Contractor shall pay for potable water for all testing. The Contractor shall contact the Commission to coordinate its use. D. Contractor's Options The Contractor may furnish ductile iron pipe and fittings, polyvinyl chloride pipe and fittings, or high density polyethylene pressure pipe and fittings for sanitary sewer force May 2009

SANITARY SEWER FORCE MAINS 02563-2 mains unless otherwise noted. Ductile or cast iron fittings shall be furnished for use with ductile iron pipe or polyvinyl chloride pipe. E. Detailed Material Requirements 1. Portland cement concrete for pipe buttresses and anchorages shall be Mix No. 1, as specified in Section 03300. 2. Ductile iron pipe and fittings, polyvinyl chloride pipe and fittings, concrete pressure pipe and fittings shall be as specified in Section 02551. Pressure rating or class shall be as noted in the Contract Documents. Cement lining and coatings shall be as required on ductile iron pipe (DIP) and fittings. 3. Joint Restraint a. Restrained joint pipe and fittings shall be of the pipe manufacturer s standard design. b. Ductile iron retainer glands for use with mechanical type joints shall be as approved. c. Rod for tie rod assemblies shall meet the material requirements of ASTM A193, Grade B7, and shall be threaded for at lease 8 inches on both ends. Rod shall be 3/4 inch diameter unless otherwise noted. d. Nuts shall meet the requirements of ASTM A194. Manufactured tie rod and accessories shall result in the completed restrained joint assembly having a minimum working pressure rating of 200 psi. 4. Resilient Seat Gate Valves Resilient seat gate valves shall be as specified in Section 02552 for water valves. 5. Valve Boxes Valve boxes shall be as specified in Section 02552, except the covers shall be labeled SEWER. 6. Sewage Air Release and Combination Air/Vacuum Valves a. Sewage air and vacuum valves shall be of the type that automatically releases air, gas or vapor under pressure, automatically exhaust large quantities of air during the filling of a system, and allow air to reenter during draining or when a vacuum occurs. 8/9/10 b. Sewage air and vacuum valves shall have an elongated stainless steel body and stainless steel cover. The internal compound lever mechanism shall be stainless steel and all other internals, including float, shall be stainless steel to positively prevent a galvanic action. The stainless steel float shall withstand a minimum pressure of 1,000 psi. c. All materials of construction shall be certified in writing to conform to ASTM specifications as follows:

SANITARY SEWER FORCE MAINS 02563-3 PART MATERIAL SPECIFICATION 8/9/10 Body and Cover Stainless Steel ASTM A48, Class 30 Internals Stainless Steel Series 300 Float Stainless Steel Series 300 Seat Buna-N Exterior Paint Phenolic Primer FDA approved for Red Oxide potable water d. The valve manufacturer shall furnish installation and maintenance instruction manuals with each valve. e. Isolating valve shall be installed between force main and air and vacuum valve. f. Sewage air and vacuum valves shall be installed in an easily accessible vault. Vault shall be adequately vented to meet air and vacuum valve requirements. g. All internals shall be easily removed through the top cover without removing the main valve from the lines. 7. Detector Tape Visual detection tape shall be 3 inches wide (minimum) nonmetallic green plastic tape, lettered SEWER in black graphics. 8. Tracer Wire for Non-Metallic Pipelines 3.0 EXECUTION Tracer wire shall be #12 AWG solid continuous copper wire with a 45 mil polyethylene insulation. The wire shall be blue, have UL markings and suitable for direct bury applications. All underground splicing shall be with butt splice connectors and shrink tubing or split bolt connectors with a water proof binder and underground electrical tape. 1. Trench excavation, foundation preparation, backfill, and compaction shall be as specified in Section 02250. 2. Force main installation shall be as specified in Section 02551, Water Main Installation and Chlorination, except chlorination is not required. 3. Pipe bedding, thrust and anchor blocks, and force main appurtenances shall be installed in accordance with the Standard Details for Water. 4. Resilient Seat gate valve installation shall be as specified in Section 02552 for water valves. 5. Sewage air release and combination air release/vacuum valves shall be installed in accordance with the Standard Details.

SANITARY SEWER FORCE MAINS 02563-4 B. Field Test 1. The force main and appurtenances shall be tested in accordance with Section 02551, except as modified herein. 2. Chlorination will not be required. 4.0 METHOD OF MEASUREMENT A. Force Main Measurement for furnishing and installing force main pipe and fittings will be per linear foot made horizontally along the centerline of the pipe through all fittings and appurtenances. B. Isolation, Sewage Air Release and Combination Air/Vacuum Valves Measurement for isolation, sewage air release and combination air/vacuum valves will be made of the number of each size and type of valves installed complete. 5.0 BASIS OF PAYMENT 1. Payment will be made at the unit and/or lump sum prices bid. The prices bid shall include furnishing all labor, tools, equipment and materials necessary to complete the work as shown, specified, and in strict accordance with the Contract Documents. 2. Payment for furnishing and installing force main pipelines and appurtenances will include the following: a. Trench excavation, backfill, compaction and incidental items as specified in Section 02250. b. Furnishing and installing bedding material for air release and vacuum valve manhole fill as per the Contract Documents. 3. Payment will be made for contingent items when approved by the Commission. B. Force Main Payment for furnishing and installing force main pipelines, complete and in place, will be made per linear foot of the size and type installed. The price(s) bid shall include traffic control, furnishing and installing all pipe, fittings, and jointing materials, removing existing buttresses when necessary, joint restraint, tracer wire and test stations where required, furnishing materials for and constructing all concrete anchorages and buttresses; strapping of fittings, connecting to existing pipelines or structures, testing; all aggregate bedding, and backfill; providing an approved spoil site, and disposing of all spoil or excess materials; all environmental and erosion or sediment control work including offsite requirements at spoil storage or borrow sites; restoration of all disturbed areas, and for all appurtenances, and incidental items to complete the force main. C. Isolation, Sewage Air Release and Combination Air/Vacuum Valves Payment for furnishing and installing isolation, sewage air release and combination air/vacuum valves, complete and in place, will be made for each size and type of valve

SANITARY SEWER FORCE MAINS 02563-5 installed. The price(s) bid shall include traffic control, furnishing and installing all valves, saddles, vaults or manholes, lids or frames and covers, pipe supports, angle valves, corporation stops, extension bar, restoration; testing of the complete installation; and incidental items to complete the valve installation. **END OF SECTION 02563**