Temporal Changes in the Terrain Conductivity of the Falls Run Refuse Pile: Preston Co., WV By Mike Solt

Similar documents
Groundwater Training Course SOPAC, April Electromagnetic (EM) Induction method for Groundwater Investigations

Electromagnetic surveying

The formation of polluted mine water

Letter Report Geophysical Subsurface Investigation Activities and Results Suspected Burial Site, Corpus Christi, Texas W.O. No

Matt Harris, Golder Associates (NZ) Ltd. The value of geophysics as a non-intrusive method for site characterisation

Introduction to Petroleum Geology and Geophysics

WHAT YOU NEED TO KNOW ABOUT LIVING NEAR INDIANA COAL MINES

This presentation reports on the progress made during the first year of the Mapping the Underworld project. As multiple Universities and Departments

GROUNDWATER PURVEYING USING VERY LOW FREQUENCY FRACTURE DELINEATION METHODS. Abstract

INVESTIGATION OF BRIDGE FOUNDATION SITES IN KARST TERRANE VIA MULTI-ELECTRODE ELECTRICAL RESISTIVITY

Decomposition of Marine Electromagnetic Fields Into TE and TM Modes for Enhanced Interpretation

Learning about GPS and GIS

Ground Penetrating Radar Survey of a Portion of the Riverside Cemetery, Hopkinsville, Kentucky

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Appendix B: Water Treatment Scenarios from AMD Treat

Application of Nuclear Magnetic Resonance in Petroleum Exploration

Earth Coordinates & Grid Coordinate Systems

Swamp Area Passive Treatment System Kettle Creek Watershed, Clinton County, PA

Metadata for Big River Watershed Geologic and Geomorphic Data

SEG Las Vegas 2008 Annual Meeting. Summary

GPR Polarization Simulation with 3D HO FDTD

The successful integration of 3D seismic into the mining process: Practical examples from Bowen Basin underground coal mines

Theory of Heating by Induction

Force on Moving Charges in a Magnetic Field

INTERPRETATION ADDENDUM CANADIAN MINING COMPANY INC. SUITE WEST HASTINGS STREET VANCOUVER, BC V6E 3X2 3D INDUCED POLARIZATION

Amplification of the Radiation from Two Collocated Cellular System Antennas by the Ground Wave of an AM Broadcast Station

CIVL451. Soil Exploration and Characterization

AQA Level 1/2 Certificate in Physics PAPER 1 SPECIMEN MARK SCHEME. AQA Level 1/2 Certificate in Physics Paper 1 MS

Robot Perception Continued

Development of EM simulator for sea bed logging applications using MATLAB

GROUND RESPONSE OF KATHMANDU VALLEY ON THE BASIS OF MICROTREMORS

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Remote Sensing, GPS and GIS Technique to Produce a Bathymetric Map

7.2.4 Seismic velocity, attenuation and rock properties

Magnetic Field of a Circular Coil Lab 12

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

THE GEOPHYSICAL VERY LOW FREQUENCY ELECTROMAGNETIC (VLF-EM) METHOD: EFFECTS OF TOPOGRAPHY AND SURFACE WATER INVESTIGATED WITH SIMULATIONS AND

Utah State General Records Retention Schedule SCHEDULE 1 GEOSPATIAL DATA SETS

PeakVue Analysis for Antifriction Bearing Fault Detection

Q1. The graph below shows how a sinusoidal alternating voltage varies with time when connected across a resistor, R.

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

U. S. Army Corps of Engineers Ground Water Extraction System Subsurface Performance Checklist

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

Physics 25 Exam 3 November 3, 2009

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 5 : Geophysical Exploration [ Section 5.1 : Methods of Geophysical Exploration ]

WELL LOGGING TECHNIQUES WELL LOGGING DEPARTMENT OIL INDIA LIMITED

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Moultrie Group Subsurface Geophysical Surveys

Selecting Receiving Antennas for Radio Tracking

By Gene Kitts, Senior Vice President-Mining Services, International Coal Group, Inc.

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

GUIDELINES FOR GEOTECHNICAL INVESTIGATION OF BRIDGE STRUCTURES. Materials Engineering Report No M (Supersedes Report No.

In-Situ Bioremediation Demonstration of Coal-Based Acid Mine Drainage. Tide Mine Site Indiana County, Pennsylvania

Topographic Maps Practice Questions and Answers Revised October 2007

The Basics of Navigation

A comparison of radio direction-finding technologies. Paul Denisowski, Applications Engineer Rohde & Schwarz

MONITORING THE GPR RESPONSE OF CURING CONCRETE T. De Souza 1, A.P. Annan 1, J.D. Redman 1, and N. Hu 1 1 Sensors & Software Inc., Mississauga, Canada

Introduction to GIS (Basics, Data, Analysis) & Case Studies. 13 th May Content. What is GIS?

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

Map Patterns and Finding the Strike and Dip from a Mapped Outcrop of a Planar Surface

EFCOG Best Practice #84. Point of Contact: David Inskeep, (208) , or Clark Scott, (208) ,

CHAPTER 2 HYDRAULICS OF SEWERS

Environmental risk managements of mine wastes (from planning to aftercare) Marja Liisa Räisänen ELY-centre for Kainuu

INTERFERENCE OF SOUND WAVES

General Physics (PHY 2140)

1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D

Model Virginia Map Accuracy Standards Guideline

Coupling Effect in Substation Ground Measurements

Self-Calibrating Remote Control Monitoring Systems

CIESIN Columbia University

Subsalt Interferometric Imaging using Walkaway VSP and Offset Free Cable geometry: A Modeling Study

potential in the centre of the sphere with respect to infinity.

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Prepared By: Sheilani Binti Shaari Department of Electrical Engineering/PKB

GROUND-PENETRATING RADAR SURVEY

Coupling Magnetic Signals to a SQUID Amplifier

ESSENTIAL COMPONENTS OF WATER-LEVEL MONITORING PROGRAMS. Selection of Observation Wells

Antenna Deployment Technical Brief

Candidate Number. General Certificate of Education Advanced Level Examination June 2014

Current and Temperature Ratings

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section

Magnetic Fields and Their Effects

Searching Land Records thru the BLM General Land Office Records.

PREDICTIVE MODELLING AND MONITORING NATURAL ATTENUATION TO SAVE REMEDIAL COSTS

The Basics of Chapter 105 Waterways and Wetlands Permitting in PA

Ultrasonic Wave Propagation Review

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Description of Simandou Archaeological Potential Model. 13A.1 Overview

Magnetic survey at Nesodden survey and interpretation report

ElectroMagnetic Induction. AP Physics B

2. THE TEORRETICAL OF GROUND PENETRATING RADAR:

3D Visualization of Seismic Activity Associated with the Nazca and South American Plate Subduction Zone (Along Southwestern Chile) Using RockWorks

STRENGTHS AND WEAKNESSES OF GRAVITY AND MAGNETICS AS EXPLORATION TOOLS FOR GEOTHERMAL ENERGY

If you require assistance in obtaining access to the presentations or have questions regarding the or Glenn Young at (916)

720 Contour Grading. General. References. Resources. Definitions

LABORATORY TWO GEOLOGIC STRUCTURES

Fundamentals of Electromagnetic Fields and Waves: I

Objectives. Describing Waterflooding. Infill Drilling. Reservoir Life Cycle

Transcription:

Temporal Changes in the Terrain Conductivity of the Falls Run Refuse Pile: Preston Co., WV By Mike Solt Abstract: This study is designed to monitor the temporal changes in terrain conductivity of the Falls Run Refuse Pile in Preston County, WV. The refuse site is currently owned and operated by the Preston County Coke and Coal Association. The refuse pile consists of four layers of material piled on top of near-surface bedrock; coal refuse, alkaline yellowboy sledge, limestone, and a thin layer of topsoil. Geophysical analysis of the current conductivity will be compared to previous studies done by Shogren (22), Tang (21), and Anderson (22) who also applied geophysical techniques to delineate anomalous regions in the refuse area for the purpose of detecting and mapping acid water source areas. The survey area consists of a 6 ft. x 14 ft. grid within where terrain conductivity observations were made at 2 ft. intervals. A Geonics EM-31 conductivity meter was used to measure the varying degrees of terrain conductivity; both vertical and horizontal dipole measurements were made. Surfer was used to map the data and to compute and map the differences between the observations made in this study to the ones made by the Geology 454 class of 2. Preliminary analysis of conductivity contours over the Falls Run Refuse Pile with observations made in 2 indicates similar anomalous regions within the area. Introduction: Acid mine drainage from high sulfur coal mine refuse, mine spoil, as well as near surface mines contaminates streams through the Appalachian region. Mine contamination from coal containing high amounts of pyrite seeping into waterways is

threatening to the environment. Mainly, the lowered ph of contaminated streams and rivers leads to elevated total dissolved solids, many of which are toxic to the surrounding flora and fauna. The Surface Mining Province Number 2, which includes Monongalia and Preston counties, is characterized by high pyrite, high sulfur content and low neutralizing potential (Bennett, 22 / Skouseen, 21, v.1 pp.91). Refuse present from the Falls Run Refuse Area comes from this high sulfur region. The coal beds from which the refuse was extracted include: The Pittsburgh coal, Kittanning coal, and the Upper Freeport coal. These coal beds are known to produce acid mine drainage when exposed to water and oxygen (Bennett, spring 22 / Dean, spring 22). Deposition of refuse at the Falls Run site began in 1983 for the purpose of disposing unusable coal from the Greer Mansion site, and from the Greer coal- processing facility. Greer continued to transport refuse to the site until 1988 when the facility was closed. Following the closure of the processing facility alkaline sludge from the Greer Mansion surface- mine sedimentation pond was dumped on the site to reduce acid seeps (Bennett, 22). A layer of limestone was then deposited over the sludge in hopes of further reducing acid seeps and neutralizing the acidity of the refuse area. Finally a layer of topsoil was placed on top of the limestone to sustain vegetation. Falls Run Refuse Disposal Area is located in Masontown, WV approximately 12 miles east of Morgantown along Route 7, approximately 1 mile past the entrance to the Greer Limestone quarries. The southwest corner of the study area s UTM coordinates are: 17 61153 E, 43848 N. Previous studies performed by WVU students Shrogen (21), Tang (21), and Anderson (22) modeled terrain conductivity, sounding and resurveyed part of the

refuse area following the initial surveys of the area conducted by the geophysics class during the fall of 2. In addition to the terrain conductivity measurements taken by the EM-31/34, various other geophysical methods were employed to delineate anomalous regions within the refuse pile. The Geophysics class of 2 provided magnetic data taken by a Geometrics proton precession magnetometer. Shrogen (21) used a Phoenix very low frequency (VLF) electromagnetic survey to supplement terrain conductivity data collected. Three anomalous regions were identified within the Falls Run Coal Refuse Pile. The comparison of very low frequency surveys to terrain conductivity surveys show similarity in anomalous regions according to Shrogen (21). For an explanation of very low frequency (VLF) surveys and study results see Shrogen (21). A major zone of high conductivity can be identified in the data collected by the geophysics class of 2. (Figure 1) Figure 1. 2 15 1 5 Data collected by Geol 454 (class of 2) 5 45 4 35 3 25 2 15 5 1 15 2 25 3 35 4 45 5 55 6 1 5 Figure 1. shows the observed terrain conductivity of the Falls Run Refuse Area measured by the 2 geophysics class in millimohs per meter. Notice the high areas of conductivity located at point A) between the 5 ft. and 1 ft. range, in the central region at point B) between the 2 ft. and 35 ft. range, and at point C) between the 5 and 6 ft. range. Yen Tang, in her analysis of the Falls Run Refuse Pile, employed a Sting and Swift resistivity imaging system. The resistivity survey was conducted to supplement the

findings of the EM-31 terrain conductivity survey. For further explanations of resistivity theories and detailed results of the study refer to Tang (21). Erin Anderson, in her 22 survey of the refuse site repeated magnetic surveys over part of the refuse area. The magnetic survey revealed what are believed to be metallic objects at the pile. For an explanation of the principals of the Geometrics proton procession magnetometer see: Anderson (22). Anderson also collected four 58 ft. EM-31 profiles over the area surveyed earlier in the fall of 2. Her survey confirmed that the area of high conductivity observed in 2 still remained at the site. Methods: The Geonics EM-31 conductivity meter was used to measure the terrain conductivity of the coal refuse site. The EM-31 conductivity meter utilizes a transmitter coil, which sends out an alternating electromagnetic field. This primary field induces a current flow in the sub-surface, which is measured, by secondary current flow measured in the meter s receiver coil. Figure 2. Figure 2.a displays the electric model for vertical dipoles. Figure 2.b shows the electrical circuit for vertical dipoles.

The time varying magnetic field arising from the alternating current in the transmitting coil induces very small currents in the earth. These currents generate a secondary magnetic field Hs, which sensed together with the primary field, Hp, by the receiver coil (McNeill, 198). Three factors influence the secondary magnetic field; inter- coil spacing s, operating frequency f, and ground conductivity σ. The secondary magnetic field is a function of the following constraints which are incorporated in the EM-31 design (McNeill, 198). Here McNeill defines the equation that describes the constraints of the secondary magnetic field, calculated by the EM-31 conductivity meter. 1) Hs ~ iωµoσ(s squared) Hp 4 where: Hs = secondary magnetic field at receiver coil Hp = primary magnetic field at the receiver coil f = frequency (Hz) ω = 2πf µo = permeability of free space σ = ground conductivity (mho/m) s = inter-coil spacing (m) i = the square root of -1 This allows the ratio of the secondary to the primary magnetic field to be linearly proportional to the terrain conductivity of the sub- surface. The Geonics EM-31 assumes a low induction number, which measures the ratio of the secondary magnetic field Hs at the receiver. This occurs when both coils are lying on the surface of a half-space of conductivity σ to the primary magnetic field Hp in the absence of half-space (McNeil, 198). The induction number, B is a function of inter-coil spacing over skin depth. 2)

B = s δ S is the intercoil spacing and δ is the skin depth. The electrical skin depth is described as the depth at which the amplitude of the electromagnetic field drops to 1/e of the source amplitude and is a function of the operating frequency and the ground conductivity (Shrogen, 21). Electrical skin depth δ is a known characteristic of a homogeneous half- space and is defined by -1 δ =5(1/σf) 3) The amplitude AR of an electromagnetic field generated by a transmitter having source amplitude As is given by equation 4. -αr Ar = Ase Where Ar is the measured amplitude at distance r As is the amplitude of the electromagnetic field at the source α is the attenuation coefficient r is the distance from the source 4) The attenuation coefficient varies in proportion to the frequency of the electromagnetic wave such that higher frequencies are attenuated mare than lower frequencies over the same distance. Therefore to obtain a greater exploration depth a lower frequency must be used (Shrogen, 21). The EM-31 conductivity meter has an inter-coil spacing of 3.7 meters, which yields an effective exploration depth of about 6 meters using a vertical dipole orientation and 3 meters when the horizontal dipole is used. The operating frequency of the Geonics EM- 31 is 65 Hz. The conductivity meter constantly evaluates the electrical conductivity so the conductivity readings displayed continuously. Output of the conductivity meter is

displayed on a scale. The secondary field intensity measured by the meter is automatically scaled according to the relationship given by equation 1). The EM-31 carried in front of the operator with a shoulder strap for convenience. Results: EM-31 conductivity results of the falls Run Refuse Area taken in the fall of 22 reveal anomalous regions in both vertical and horizontal orientations. The terrain conductivity of the refuse area ranges from to 38 in the vertical dipole survey, and from to 25 in the horizontal dipole survey (figure 3.). The location of the anomalies is consistent between the horizontal and vertical orientations, showing an increase in extent of the anomalous region with increased depth. Three areas with conductivity higher than 25 are observed from the measurements of the terrain conductivity in the vertical dipole orientation. These areas are located on the x axis between 5 and 1 ft., between 15 and 375 ft., and between 525 and 6 ft. possibly extending beyond 6 ft (figure 3.). The data taken in the horizontal dipole orientation, which has a shallower penetration depth, reveal areas of conductivity greater than 16 in approximately the same location along the x axis as the vertical data. Figure 3. 15 1 5 Mike Solt's Vertical Dipole Data (Fall 22) (coordinate rotation applied) 5 1 15 2 25 3 35 4 45 5 55 6 4 35 3 25 2 15 1 5 Terrain Conductivity Data Falls Run Refuse Area

Figure 3. Terrain Conductivity Data Falls Run Refuse Area 15 1 Mike Solt's Horizontal Dipole data (Fall 22) (coordinate rotation applied) 28 24 2 5 16 12 8 5 1 15 2 25 3 35 4 45 5 55 6 4 Figure 3 demonstrates the terrain conductivity of the falls Run Refuse Area. Three anomalous regions, A, B, & C, are present and consistent between the horizontal and vertical measurements. Universal Transverse Mercator (UTM) coordinates were recorded for the purpose of geo- referencing the refuse site (figure 4.). Global Positioning Satellites (GPS) were used to determine the UTM coordinate. A hand- held GPS unit; constructed by Navistar, uplinked to three or more satellites orbiting the planet triangulates its location with and accuracy of about 1 m. Although this degree of precision may not be useful in referencing the location of anomalous regions within the refuse area, it will help co reference the survey area with digital ortho-photo quadrangle images. Figure 4. Vertical Dipole Measurements - Mike Solt (Fall 22) 4 36 32 1 5 28 24 2 16 12 5 1 15 2 25 3 35 4 45 5 55 6 8 4

Figure 4. represents UTM coordinates for the corners and along the midpoint of line #1. UTM Coordinates A. 17 6111E B. 17 614E 438588N 438615N C. 17 619E D. 17 61181E 438535N 43851N E. 17 61153E 43848N The strike along the x- axis from to 6 is N28W. Comparison: The EM terrain conductivity data collected in fall, 22 has been rotated to fit the spacing intervals collected by the geophysics class of 2. The results of the data measured with the vertical dipole orientation in fall, 22 show anomalous regions to be located in the same areas as the data of the 2 geophysics class measured in the vertical orientation. (Figure 5.) Using the same contour interval of 5, it is clear that the apparent electromagnetic terrain conductivity within the anomalous regions has dropped. Areas of high terrain conductivity, measured at a depth of about 6 meters, in the 22 data are not as laterally extensive as those measured in 2. (Figure 5.) It is also apparent that the values of the terrain conductivity for the 22 data are not as elevated as those in the measured data from 2. The maximum value illustrated below (Figure 5), recorded in fall of 22 tops out at 35, while the data collected in 2 shows a maximum value of 45. This 22% reduction in the maximum conductivity values marks an overall reduction in conductivity in this region of the refuse pile (Figure 6 ).

Figure 5. 15 Mike Solt's Data (22) y coordinate transformation ynew = yold - 2 + x/15 5 45 4 1 5 35 3 25 2 15 1 5 1 15 2 25 3 35 4 45 5 55 6 5 2 15 Data collected by Geol 454 (class of 2) 5 45 4 35 1 5 5 1 15 2 25 3 35 4 45 5 55 6 3 25 2 15 1 5 Figure5. shows the reduction in overall conductivity of the observed zone of the Falls Run Refuse Area from the years 2 to 22. This reduction is obvious through the diminished extension of anomalous areas and lower maximum conductivity values. Figure 6. Conductivity Difference: Vertical Component (year 2 observations -year 22 observations) 2 15 1 5 1 5 5 1 15 2 25 3 35 4 45 5 55 6-5 -1-15 -2 Figure 6 displays the difference in conductivity measured by the geophysics class of 2 and the data collected in the fall of 22. In the zones labeled A, B, C, the map shows a reduction in the conductivity. In zone D there is a significant increase in a small area.

Conclusions: Geophysical methods are not only useful in determining the extent and location of AMD sources in the shallow sub-surface, but are also useful for documenting how conductivity changes over time. In this particular study, the Geonics EM-31 demonstrated an efficient and cost effective solution to determining shallow sub-surface conditions in the Falls Run Refuse Area. Three anomalous regions have been identified within the Falls Run Refuse Area. These regions show elevated conductivity levels that are interpreted to correlate with increasingly acidic waters filling the pore spaces with the refuse. In comparing data collected during the fall semester of 2 to the data collected during the fall semester of 22, the results reveal that a 22% reduction in the maximum values of the overall terrain conductivity has occurred during that two year time period. This reduction is complemented by a reduction of the aerial extent of the contaminated zones from two years ago. Action to remedy the acid seep sources is presently underway and has been in the past. The analysis of the geophysical information gathered at the Falls Run Refuse Area can be helpful in pinpointing the location of AMD trouble areas, thus reducing excavation costs. The time lapse comparison also indicates that treatment of the refuse area has been successful in reducing the overall acidity of the pile. Acknowledgements:

Thanks to Joe Dean of Greer Industries for permission to access the Preston County Coal and Coke Co. Refuse Area. This area provides students with the opportunity to develop skills in dealing with geophysical instrumentation for sub-surface investigation. Also thanks to Dr. Tom Wilson for providing the geophysical instruments necessary in conducting this survey, Jamie Tallman for his time, effort, and consistent note taking ability, Bill Carpenter, Francis Rengers, and John Suther. References: Anderson, E., 21, A Geophysical Investigation Using Terrain Conductivity and Magnetic Methods: West Virginia University, Senior Thesis, 12p. Bennett, L., 22, Survey and Assessment of the Falls Run Coal Refuse Pile Using Principals of Geochemistry: West Virginia University, Senior Thesis, McNeill, J., 198,Electromagnetic Terrain Conductivity Measurements at Low Induction Numbers: Geonics Limited, Technical Note, pp. 1-15. Shrogen, J., 21, The Use of Terrain Conductivity and VLF Methods to Locate Acid Seep Source Areas in a Coal Run Refuse Pile: West Virginia University, Senior Thesis, 23p. Tang, Y., 21, Resistivity and Terrain Conductivity Surveys over a Refuse Pile in Northern West Virginia: West Virginia University: Senior Thesis, 31p. Wilson, Dr. T., 22 Environmental and Exploratory Geophysics: West Virginia University, Class Lecture/ Field Trip, fall 22.