Measuring Telecommunication Transformers

Similar documents
Application Note. So You Need to Measure Some Inductors?

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

GUIDE FOR TESTING POWER TRANSFORMERS

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

MEASUREMENT SET-UP FOR TRAPS

Experiment 7: Familiarization with the Network Analyzer

Measuring Biased Inductors with the GenRad Digibridge

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Contactless Power Transfer : Inductive charging of EV

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

ATE-A1 Testing Without Relays - Using Inductors to Compensate for Parasitic Capacitance

Without the pre amp, these microphones sound very good with tube equipment that provided a very high impedance load to the element.

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

PROCEDURE: 1. Measure and record the actual values of the four resistors listed in Table 10-1.

Welcome to the combined product training module of Linear Technology and Wurth Electronics about their efficient design solution for DC/DC Flyback

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

EMI and t Layout Fundamentals for Switched-Mode Circuits

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

An Overview of Practical Capacitance Bridge Functioning. by Paul Moses

Line Reactors and AC Drives

Reading: HH Sections , (pgs , )

Kit Watt Audio Amplifier

Since any real component also has loss due to the resistive component, the average power dissipated is 2 2R

Impedance 50 (75 connectors via adapters)

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

Power Quality Paper #3

AVR127: Understanding ADC Parameters. Introduction. Features. Atmel 8-bit and 32-bit Microcontrollers APPLICATION NOTE

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

Mutual Inductance and Transformers F3 3. r L = ω o

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Impedance Matching. Using transformers Using matching networks

S-Parameters and Related Quantities Sam Wetterlin 10/20/09

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

W03 Analysis of DC Circuits. Yrd. Doç. Dr. Aytaç Gören

Measurement setup for differential-mode and common-mode channels


Custom Products. Magnetic Components. Vishay Dale.

Agilent Advanced impedance measurement capability of the RF I-V method compared to the network analysis method. Application Note

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

RFID Receiver Antenna Project for Mhz Band

Application Note AN- 1095

SELECTION GUIDE. Nominal Input

Lab 8: DC generators: shunt, series, and compounded.

Current Probes, More Useful Than You Think

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

UltraFED IIB. 30 MHz Far-End Device

ENGR-2300 Electronic Instrumentation Quiz 1 Spring 2015

LS RS. Figure 1: Assumed inductor model

PIEZO FILTERS INTRODUCTION

(3 )Three Phase Alternating Voltage and Current

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Germanium Diode AM Radio

Lab E1: Introduction to Circuits

Chapter 11. Inductors ISU EE. C.Y. Lee

Current Transformers

Technical Note #3. Error Amplifier Design and Applications. Introduction

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

TS321 Low Power Single Operational Amplifier

Transistor Amplifiers

THE STRAIN GAGE PRESSURE TRANSDUCER

VOLTAGE REGULATOR AND PARALLEL OPERATION

Measurement of Capacitance

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Buffer Op Amp to ADC Circuit Collection

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Balanced vs. Unbalanced Audio Interconnections

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Solar Energy Conversion using MIAC. by Tharowat Mohamed Ali, May 2011

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Critical thin-film processes such as deposition and etching take place in a vacuum

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Subminiature Load Cell Model 8417

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Application Guide. Power Factor Correction (PFC) Basics

css Custom Silicon Solutions, Inc.

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Measurement of Inductor Q with the MSA Sam Wetterlin 3/31/11. Equation 1 Determining Resonant Q from Inductor Q and Capacitor Q

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

LR Phono Preamps. Pete Millett ETF.13.

Power Factor Correction for Power Systems First Semester Report Spring Semester 2007

AN1991. Audio decibel level detector with meter driver

Bridgeless PFC Implementation Using One Cycle Control Technique

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transformer circuit calculations

Common Mode and Differential Mode Noise Filtering

Transcription:

Measuring Telecommunication Transformers Rapid expansion of the Internet and Mobile Communications has driven the need to transmit digital information at high frequencies. This need has put new requirements on transformer manufacturers and presented new challenges to test equipment designers. This paper explores the changing applications for high frequency transformers, the challenges this presents to test equipment designers and test solutions offered by the Wayne Kerr (3260B and 3261A). Background Transformers can be grouped into two broad classes - Power and Signal (High Frequency) Transformers. Linear power transformers generally operate at a single line frequency, and high drive levels, SMPS (switch mode power supplies) require transformers to work under similar conditions at higher frequencies. Signal transformers are required to operate from low to high drive levels and multiple frequencies; they have been traditionally used to transmit signals at audio frequencies. However in recent years the requirement has been changing to transmit high-speed digital data. Typical technologies today include ISDN, HDSL and most recently ADSL. The basic test conditions for both groups are different. Power transformers require to be tested at fixed frequencies, with high drive levels. HF and Signal devices tend to be tested at low power and across a wide frequency range. In general they are small, often SMD parts. Basic Measurements Power transformers have a good correlation between the measured elements and the desired parameter, as seen in the table below, enabling a transformer to be characterised from the measured primary elements. Parameters Output Voltage Magnetising Current No Load Watts Power Loss Regulation Elements Turns Ratio Primary Inductance Primary Shunt Loss (Q), Leakage Inductance Signal transformers require a different set of measured parameters. To directly measure parameters such as insertion loss (IL) and return loss (RL) requires different terminating networks and the use of precision components, this allows high frequency measurements to be performed accurately. It is also possible to derive the required measurements such as IL and RL from accurate measurements of the primary elements shown in the table below.

Return Loss Parameters Insertion Loss Elements Turns Ratio squared Primary L & Q Self Capacitance, Leakage L Turns Ratio Primary L & Q Self Capacitance, Leakage L The derivation method used in the Wayne Kerr 3260B provides an advantage over the direct measurement method used in the Wayne Kerr 3261A, by allowing Insertion Loss (IL) and Return Loss (RL) to be derived without the need to connect different terminating networks and use of precision components. Using the Wayne Kerr 3260B terminating values can be entered from the instrument keypad. However above 20kHz the accuracy of the derived measurements decreases rapidly. The direct measurement technique used in the 3261A maintains accuracy for frequencies up to 3MHz. The technique also allows Longitudinal Balance (LB) and THD to be measured accurately and without the need to use different fixtures. The picture below shows the 3260B Precision Magnetics Analyzer deriving IL and RL using the derivation method described above. Basic Measurement Connections There are a number of connection methods suited to different measured parameters. These common methods include 2-wire, 4-wire Kelvin, and Kelvin transformer. The 2-wire connection is the most basic and generally used for non-critical measurements, it is not suitable for low impedance measurements. The 4-wire Kelvin is the most common measurement connection and was originally devised for making accurate low impedance measurements. The connection to the component under test is independent of the resistance of the connecting leads. ie. cable length is unimportant. The Kelvin transformer allows simultaneous connection to the primary and secondary of a transformer. For accurate turns-ratio, you need Kelvin connections on the primary to eliminate loading effects, the secondary side only requires 2 wires, however Wayne

Kerr added two more to the secondary to allow accurate secondary Rdc and Leakage L measurement without having to change the leads. Primary Secondary 2-wire 4-wire Kelvin Kelvin transformer Symbol Brown Red Orange Yellow Sense Low Drive Low Drive High Sense High Low Frequency (LF) sources of error and applied corrections At low frequencies there are two major sources of error. The first is due to coupling and noise between connecting leads and the second is caused by residual L, C, & R in cables and fixtures. Both are easy to correct. Noise and coupling between connecting leads can be reduced by using screened cables and residual L, C & R of the fixture and cables can be corrected by applying an offset correction through an open circuit (OC) and short circuit (SC) trim. See figure below. Connecting Cables Residual Impedance (Zs) Stray Admittance (Yo) Rs Ls Co Go Device under test Fixture Residual High Frequency (HF) sources of error and applied corrections At high frequencies we need to apply a different set of rules in order to compensate for measurement errors. At 50MHz everything must be terminated. For frequencies between 200kHz and approximately 5MHz the LF technique can be adapted, without the need to terminate the voltage and current sensing cables.

Errors due to unterminated cables are Scalar ie. the same at all levels and impedance s. Magnitude errors are worse than phase errors and are proportional to the frequency and cable length squared. Therefore a good basic rule is to reduce the test lead length as the frequency increases. Example AC voltmeter with Cin 50pF, 1m long screened input lead. At 1MHz this reads high by 0.1%. At 5MHz it becomes 2.5%. Double the cable length and the error goes to 0.3% and 7.5% respectively. HF Impedance measurement (V:I) In the Impedance measurement we sense both voltage and current. However due to the unterminated voltage and current sensing cables there are errors on both these. Voltage and current sensing errors can be the same or opposite polarity depending on the configuration of the instrument but they never cancel. A correction is always needed. Corrections Some equipment manufacturers use a fixed correction. But, these only remain valid if you use their test leads. Others make it user selectable dependent on cable length. However, the fixture adds errors that are dependent on the cable length, making this method inexact, the total uncertainty of the measurement being the sum of the errors in the Instrument, Cable and Fixture. Wayne Kerr use a calibration component with a known frequency response. This method works with any test lead or fixture and it allows the instrument accuracy to be maintained to the test device. The instrument runs a software routine to calculate the gain and phase errors at each frequency. This means the routine only needs to be re-run if the fixture or test leads are changed. It also allows the use of custom leads and fixtures. The calibration component needs to have a good frequency characteristic. Suitable components include a Polystyrene or Porcelain capacitor with a value between 100 and 150pF. HF Turns Ratio measurement (V: V) Making a standard connection to a component for turns ratio measurement gives an additional unquantifiable error, due to the primary and secondary sense cables being of different lengths. This particular error is simply overcome by using a Kelvin connection on the primary as in the example below. The Kelvin connection to the primary gives similar sense arrangements for both the primary and secondary and the error cancels out.

Drive V1 Primary Sense Connecting Cables (equal length) V2 Secondary HF Turns Ratio Connections Summary This paper has looked at the typical sources of error for both LF and HF measurements when testing transformers and identified appropriate corrections. These are summarized in the table below. Error Correction LF Error Sources (up to 200kHz) Noise Screened Cables Cable and Fixture due to Offsets corrected by open circuit residual L, C & R and short circuit trim HF Error Sources (200kHz approx. 5MHz) Impedance (V:I) Use calibration component Scalar error due to unterminated cables Turns Ratio (V:V) Use Kelvin connection on primary Scalar error due to winding unterminated cables The Wayne Kerr 3260B can use any measurement lead or fixture and maintain accuracy at the transformer at high frequencies. The Wayne Kerr 3260B can also derive IL and RL of line matching transformers to 20kHz. When used with the 3261A IL, RL and LB can be measured accurately to 3MHz. In addition the 3261A is able to derive THD of the transformer. Simon Harman Product Manager Wayne Kerr Electronics