Information LZ100 Command Station Version 2.3

Similar documents
LocoNet, the Digitrax Difference

BMD16N-SD. version 1.2

POINTS POSITION INDICATOR PPI4

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Central Station. with Update

Modular I/O System Analog and Digital Interface Modules

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

The Sync and Charging Cable for Galaxy Tablets is a portable and easy-to-use sync and charging cable for a variety of Galaxy Tablets.

Points Position Indicator (PPI1) for Points Motors with Common Ground

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

GAUGEMASTER PRODIGY EXPRESS

WEB log. Device connection plans

MasterControl. Central unit for digital control EasyControl. Manual. Art.-Nr

USB/VGA Cat 5 UTP Console Extender

central station Unsurpassed in its Groundbreaking Features: Innovative Digital Worlds of Train Operation. Developed by Märklin.

The Hare TM REV J, 5/20/2011

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Multi-Protocol decoder with Load regulation

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

INSTRUCTION MANUAL. FOR TECHNICAL ASSISTANCE: VERSION 3.2 ITEM #330

Complete Train Control. Run Your Trains, Not Your Track!

CONTROL SWITCHER User s Manual (Preliminary)

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

CONSOLE REMOTE I /O AC 9V

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

How To Make A Feedback Decoder For A Model Railroad

SIM 3 TRACES OF MISWIRED AND/OR DAMAGED BALANCED (3-PIN XLR) CABLES

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

DPI 260 SERIES: Digital Pressure Indicators

Assembly Instructions: Shortwave Radio Kit

Atlas Model RR Signal System Operating Manual

Square D Clipsal C-Bus Network Analyzer

PRO PLM Installation Instructions

PUSH BUTTON START INSTALLATION MANUAL

WEB log. Device connection plans

SYSTEM 4C. C R H Electronics Design

EMBEDDED ACCESS CONTROL Hardware Installation Guide

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

HDMI to 3G-SDI Converter Quick Installation Guide

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Harford County Modular Model Railroad Fall 2014

AXIS T81B22 DC 30W Midspan

Part Name/Description Part Number Quantity. Power Cable

Using installed Fieldbus Wiring to carry Ethernet Communications

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

RX4 Transponder Detector Installation Manual

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Brief Information LAN/USB Interface. Art. no st edition, 10 11

EDI Distributor Control Interface Wiring and Setup Instructions

SwitchPilot. User manual Third edition, October SwitchPilot SwitchPilot Extension SwitchPilot Servo P/N

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CAN AND NETWORK COMMUNICATIONS

Dynamis User Guide. Contents

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Technical Guide for Installation and Maintenance

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

USB 2.0 Bay Media Card Reader Quick Installation Guide

Multi-Protocol decoder

CAT5 KVM Extender User Manual

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

DisplayPort 2-Port KVM Switch Installation Guide

RGB for ZX Spectrum 128, +2, +2A, +3

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

TS510 & TS500. Installation & User Guide. Compatible Equipment

Hatton s MD4 Decoder. Thank you for purchasing Hatton s Decoders.

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

e-ask electronic Access Security Keyless-entry

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

CURRENT TRANSFORMERS INSTALLATION GUIDE

Digital input modules

S88XPressNetLI v1.0. Installation, user and reference manual KDesign Electronics, PCB design by RoSoft

NC-12 Modbus Application

UNPACKING AND CONNECTING THE COMMODORE 64

Installation instructions for Series NRX INCOM communications adapter module

STANDALONE PCI INTERFACE PACKAGE

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

INSTALLATION GUIDE. FCC ID NOTICE

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS/2 KVM Console Extender User Manual (GCE250)

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Operation and Installation Manual

CoolWave r 2 Phase Control Board and Cable Replacement Kits

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

ImmersionRC Uno5800 v4 5.8GHz Audio/video receiver. Instruction manual - International edition

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Transcription:

Command Station LZ100 1 Information LZ100 Command Station Version 2.3 Art. No. 20101 December, 1996

2 Command Station LZ100 Getting started To get started with, you need: Command Station LZ100 Hand Held Controller LH100 Power Station LV100 Locomotive equipped with a locomotive decoder, or with another NMRA-DCC compatible locomotive decoder (or an Arnold Digital or Märklin Digital= decoder) Transformer providing 16 volt AC and 50VA output The units have removable multi-pin connectors with screw terminals, to make connecting wires easy. Wire Command Station LZ100 and Power Station LV100 together as shown in Figure 1. Terminals U and V on Command Station and Power Station are the connection points for the transformer. Connect terminals C, D and E on the Command Station with the corresponding terminals on the Power Station. Terminals J and K on the Power Station are for the connection to the track (See Figure 2 and 3). Plug the connector of the Hand Held Controller LH100 into the round 5-pin DIN terminal on the back of LZ100, marked XBUS. Figure 1: Connecting LZ100 to Power Station LV100

Command Station LZ100 3 Figure 2: Connecting to 2-Rail Figure 3: Connecting to 3-Rail After connecting all the units, plug the transformer into a power outlet. The display of the Hand Held Controller will briefly show LH100, then it will display the address of the most recently used locomotive, along with its data. On first use, the display will show locomotive address 3 (factory set). If your digital locomotive has another address, then press Cl key on the Hand Held Controller. Next enter the desired locomotive address on the keypad and verify it by pressing the Enter key. Now you can control the speed of your digital locomotive with the following keys: If you want to change your locomotive s direction of travel, first set the speed to step 0, then press the hexagonal key. The new direction will be shown in the display. With the 0 key you can turn the locomotive headlights on and off (if connected). See your LH100 manual for more details.

4 Command Station LZ100 System design of is a digital multi-train control system for all model railroad scales. It was developed in close cooperation with model railroaders. The basis for its development was the digital systems Arnold Digital and Märklin Digital=, also developed by Lenz Elektronik GmbH. Figure 4 shows the simple and clear system design of. is compatible with NMRA-DCC systems and their locomotive and accessory decoders. If you have older Arnold Digital and Märklin Digital=, you can use locomotive decoders and accessory decoders from these systems with. Also, if you have devices from these systems (control 80, keyboard, etc), then you can continue to use them with the original central unit= and the Translation Module LC100 together with. Figure 4: System Overview If you encounter compatibility problems with components you already have, please contact us. We will do our best to resolve such problems.

Command Station LZ100 5 The capabilities of are to a large extent determined by a program running inside the unit, the software. The advantage of this approach is that new functions can be adopted simply by changing the software. It is not necessary to purchase new units. This way it is easier to implement suggestions for improvements from model railroaders. Command Station LZ100 The core of the system is Command Station LZ100. It coordinates the input devices (Hand Held Controller LH100, etc.) and is also responsible for data processing. Information is exchanged between Command Station and input devices via a 4-wire cable, the XBUS. The Command Station generates the control signals for Power Station LV100, which combines them with the necessary power and sends them to locomotive and accessory decoders. Therefore, the Command Station has no boosted output to connect to tracks. Accordingly it only needs a small transformer (15VA), which could be one you already have from a starter set. If you use a more powerful transformer, you can connect the Command Station and the Power Station to the same transformer. Connecting the Command Station Command Station LZ100 is connected to the AC output of the transformer with 2 wires at terminals U and V (see Figure 5). If you use the digital transformers 6002 (Märklin) or 86002 (Arnold), you use their yellow and brown terminals. Connect the programming track to terminals P and Q. This track must be completely isolated from the rest of the layout. At terminals C and D the data signal needed by the Power Station is available. These terminals are connected with the corresponding terminals on the Power Station with a twisted pair wire (see Figure 5). You can easily make a twisted pair wire from two normal single wires that you twist together.

6 Command Station LZ100 Figure 5: Complete Connections of Command Station and Power Station If terminal E on the Command Station is connected to terminal E on the Power Station, the Power Station is able to provide feedback about overloads. The Command Station will then turn off all other Power Stations and send the corresponding information to Hand Held Controllers and other input devices. The feedback bus is connected at terminals R and S. Via this wire, which also must be a twisted pair, the Command Station asks for the state of for example turnouts or track occupancy detectors. For this purpose, feedback units are connected to this (Accessory Decoder with Feedback LS100 or Feedback Encoder LR100). For more details on connecting these units, please refer to the respective manuals. If the Command Station is correctly installed and wired, and the supply power of the transformer switched on, the LED on the front of the Command Station lights up. If the LED flashes after the power up, then there is a wiring problem on the XBUS. Data transfer between Command Station and input devices The connecting wires from Command Station LZ100 to the input units, for instance Hand Held Controller LH100, or the Interface, are referred to as XBUS.

Command Station LZ100 7 Figure 6: When wiring the X-BUS, wires must not be allowed to branch or loop Via this bus, the Command Station and connected devices exchange information. A maximum of 30 devices are allowed on the XBUS. Each of the connected units has its own address, so that data exchange is problem-free. Directions for how to change the address of Hand Held Controller LH100 or another input device on the XBUS are found in the corresponding manuals. The XBUS can be connected to the Command Station via either a 5-pin DIN connector or terminals L, M, A and B. You can connect the first Hand Held Controller directly to the 5-pin DIN connector on Command Station LZ100. If you want to connect additional Hand Held Controller LH100 (or other input devices) to Command Station LZ100, then you use terminals L, M, A and B. Via the wires at terminals A and B, the units exchange data with the Command Station. Via the wires at terminals L (plus) and M (minus) the units are supplied with power. Figure 7: Connecting Panel 21150 Figure 8: Pin Assignments from solder side From these terminals you run wires (XBUS wire) to the connecting panels (see Figure 7, catalog number 21150). You can also solder the wires yourself to a female 5-pin DIN connector. These connectors are readily available in electronics stores. The pin assignments of the 5-pin DIN connector are shown in Figure 8.

8 Command Station LZ100 Make sure that you do not accidentally reverse the polarity at terminals L and M by switching wires. This could cause damage to connected input devices. The XBUS wire must be installed so that the line starts at the Command Station and ends somewhere on your layout. (Daisy chained from Command Station via intermediate input locations to the last input location.) Between the start and end you may insert connecting panels or 5-pin DIN connectors anywhere. You may not route the wire in a hub-spoke pattern or as a closed loop. Under all circumstances you must ensure that the wires that are connected to terminals A and B are twisted. All wires should have a cross section of at least 0.25 square millimeter. The length must not exceed 100 meter (327 feet). The ends of the data bus must be connected (terminated) with a resistor (included with the Command Station). The value of the resistor is 120 Ohm. Figure 9: Terminating the X-BUS with a 120 Ohm Resistor Hüttenbergstraße 29 35398 Gießen, Germany Hotline: 06403 900 133 Fax: 06403 5332 http://www.lenz.com Lenz Agency of North America PO Box 143 Chelmsford, MA 01824 ph/fax: 978 250 1494 support@lenz.com This equipment complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1996 Lenz GmbH, All Rights Reserved