Ontario s Building Code

Similar documents
OFM-TG Office of the Fire Marshal F M FIRE DRILLS GUIDELINE

Overview of Hotel Fire Safety Requirements

RULES OF DEPARTMENT OF MENTAL HEALTH AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES TABLE OF CONTENTS

Executive Summary Inclusion of Current Firewall Requirements in NBCC

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

How To Build A Two Hour Firewall In Calgary

Effective Use of Two Stage Alarms & Voice Communication Systems

Small Business Permit Service

SECTION 903 AUTOMATIC SPRINKLER SYSTEMS

(1) Signals to Fire Department A new requirement inserted due to a new defined use for Group C retirement homes.

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

CHAPTER 9 FIRE PROTECTION SYSTEMS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

The New Life Safety Chapter What It Applies to and How Organizations Can Comply with It

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

FIRE CODE INTERPRETATION

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

Life Safety Code Enabling References

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

An inventory of hazardous materials used in your workplace will prove useful.

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Fire Alarm Systems Requirements by Occupancy Type

City of San Antonio (COSA) Boarding Homes Fire Sprinkler System Training

You depend on others to assist you with one or several of these three areas. Long-Term Care

FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) Fax: (306)

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

TOWN BOARD OF THE TOWN OF NORTH SALEM WESTCHESTER COUNTY, NEW YORK LOCAL LAW # OF THE YEAR 2012

2012 Changes of the International Building Code Compared to the National Fire Protection Association- 101

Building Mechanical Inspector Senior Building Mechanical Inspector Principal Building Mechanical Inspector Chief Building Mechanical Inspector - 2

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Chapter 492 GREEN ROOFS

SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

How To Install A Carbon Monoxide Detector

City of Bettendorf Fire Alarm System Requirements

ASHE American Society for Healthcare Engineering of the American Hospital Association

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

New Ontario Building Code Highlights

Excerpts from the Canadian National Building Code (NBC)

Interior Designers Act

SACRAMENTO VALLEY FIRE MARSHALS ASSOCIATION

ESA MODEL FIRE ALARM ORDINANCE GOVERNING ALARMS RESPONDED TO BY FIRE OFFICIALS

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

CITY OF EDMONTON GROUP HOME INFORMATION & APPLICATION GUIDE

Maryland Updates Smoke Alarm Law What You Need to Know

Code Requirements for Existing Buildings

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

ECONOMIC DEVELOPMENT, NEIGHBORHOODS, AND STRATEGIC PLANNING DEPARTMENT M E M O R A N D U M

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

Errata NFPA 1. Fire Code Edition

Ministry of the Environment Decree. on housing design

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

April 2, 2007 TO: BUILDING CODE USERS

RULES AND REGULATIONS OF THE SAFETY FIRE COMMISSIONER CHAPTER RULES AND REGULATIONS FOR THE STATE MINIMUM FIRE SAFETY STANDARDS

SECTION THREE CONSTRUCTION CODES


ORDINANCE NO O-01

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

FIRE SAFETY REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

CHILD CARE LICENSING REGULATION

Practice Note

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

PREFACE. Arrangement. Overview. Codes Purchased from ICC. Technical Assistance. Introduction

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Winnipeg Fire Department Fire Prevention Branch

Building Performance Bulletin

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Chapter 3: Use and Occupancy Classification

Indiana Building Rehabilitation Standard

Amendments to the 2012 INTERNATIONAL FIRE CODE

ASSISTED LIVING BACKGROUNDER

Fire Code Inspector II

New York City Department of Buildings

Georgia State Amendments to the International Fire Code (2012 Edition)

Enrolled Copy S.B. 117

Building Code Clarifications - 7. Fire Resistance

BUILDING CODE COMMISSION

Multi-storey residential buildings - warranty insurance exemption. This updates the previous Practice Note issued June 2006

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

PLUMBING CODE REGULATION

SUBCHAPTER B. INSURANCE ADVERTISING, CERTAIN TRADE PRACTICES, AND SOLICITATION 28 TAC , , , and

REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET

Fire Safety Risk Assessment

SAN DIEGO COMMUNITY COLLEGE DISTRICT INSTITUTIONAL REVIEW BOARD (IRB) INVESTIGATOR GUIDELINES FOR RESEARCH USING HUMAN SUBJECTS

Transcription:

Ministry of Municipal Affairs and Housing Ontario s Building Code ONTARIO ONLY PROPOSED CHANGE TO THE 2012 BUILDING CODE CHANGE NUMBER A-01-04-01 CODE REFERENCE Div. A /1.4.1.2.(1) DESCRIPTION OF PROPOSED AMENDMENT Delete the definitions of care or detention occupancy and care and treatment occupancy, revise the definition of care occupancy, detention occupancy and residential occupancy, and introduce new definitions of care, treatment, and treatment occupancy to harmonize with the model National Building Code of Canada EXISTING 2012 BUILDING CODE PROVISION(S) 1.4.1.2. Defined Terms Care or detention occupancy means the occupancy or use of a building or part of a building by persons who, (a) are dependent on others to release security devices to permit egress, (b) receive special care and treatment, or (c) receive supervisory care. Care and treatment occupancy (Group B, Division 2) means an occupancy in which persons receive special care and treatment. Care occupancy (Group B, Division 3) means an occupancy in which persons receive special or supervisory care because of cognitive or physical limitations, but does not include a dwelling unit. Detention occupancy (Group B, Division 1) means an occupancy in which persons are under restraint or are incapable of self preservation because of security measures not under their control. Residential occupancy means the occupancy or use of a building or part of a building by persons for whom sleeping accommodation is provided but who are not harboured or detained there to receive medical care or treatment or who are not involuntarily detained there. PROPOSED CODE CHANGE Delete the following definitions and make corresponding editorial changes to the affected provisions in the Building Code: Care or detention occupancy Care and treatment occupancy Revise the following definitions to harmonize with the model National Building Code (mnbc) definitions: Care occupancy (excluding the reference to behavioural limitations) Detention occupancy Residential occupancy Adopt the following modified definitions from mnbc: Care Treatment Treatment occupancy

Include associated commentary adopted / adapted from mnbc 1.4.1.2. Defined Terms Care or detention occupancy means the occupancy or use of a building or part of a building by persons who, (a) are dependent on others to release security devices to permit egress, (b) receive special care and treatment, or (c) receive supervisory care. Care and treatment occupancy (Group B, Division 2) means an occupancy in which persons receive special care and treatment. Care means the provision of services other than treatment by or through care facility management to residents who require these services because of cognitive or physical limitations. ** Care occupancy (Group B, Division 3) means the occupancy or use of a building or part of a building where care is provided to residents. Detention occupancy (Group B, Division 1) means the occupancy by persons who are restrained from or are incapable of evacuating to a safe location without the assistance of another person because of security measures not under their control. Residential occupancy means the occupancy or use of a building or part of a building by persons for whom sleeping accommodation is provided but who are not harboured for the purpose of receiving care or treatment and are not involuntarily detained. Treatment means the provision of medical or other health-related intervention to persons, where the administration or lack of administration of these interventions may render them incapable of evacuating to a safe location without the assistance of another person. Treatment occupancy (Group B, Division 2) means the occupancy or use of a building or part of a building for the provision of treatment, and where overnight accommodation is available to facilitate the treatment. ** Does not include the reference to behavioural limitations contained in mnbc. Associated Commentary A-1.4.1.2. Defined Terms Care Occupancy Support services rendered by or through care facility management refer to services provided by the organization that is responsible for the care for a period exceeding 24 consecutive hours. They do not refer to services provided by residents of dwelling units or suites, or to services arranged directly by residents of dwelling units or suites with outside agencies. In the context of care occupancies, these services may include a daily assessment of the resident's functioning, awareness of their whereabouts, the making of appointments for residents and reminding them of those appointments, the ability and readiness to intervene if a crisis arises for a resident, supervision in areas of nutrition or medication, and provision of transient medical services. Services may also include activities of daily living such as bathing, dressing, feeding, and assistance in the use of washroom facilities, etc. No actual treatment is provided by or through care facility management. Inherent in receiving special or supervisory care services for cognitive or physical limitations are the residents limited capacity for self-preservation and reliance on staff for assistance in evacuation to a point of safety in the event of a fire emergency. Residents requiring assistance to evacuate could include persons who: are incapable of independent mobility; require assistance to use or access a mobility aid, e.g., transferring to and from a wheelchair or accessing a walker or cane; are incapable of following directions under emergency conditions; or are capable of self-evacuation, but not without direction or within time frames considered necessary for safe evacuation in an emergency situation.

Treatment The ability to evacuate unassisted implies that a person is capable of recognizing and responding to an emergency given their physical, cognitive and behavioural abilities, and able to move to a safe location without the assistance of another person. For example, such persons must be able to arise and walk, or transfer from a bed or chair to a means of mobility, and leave the building or move to a safe location on their own. Treatment Occupancy "Treatments" may include such things as surgery, intensive care, and emergency medical intervention. Treatment services differ from the services provided by care occupancies like personal care assistance or the administration of medication, and from those provided by business and personal services occupancies like dentistry or day procedures. RATIONALE FOR CHANGE Problem / General Background The Vulnerable Occupancies Technical Advisory Committee (TAC) identified that the current definitions would benefit from additional clarity in that: they include terms and phrases that are not clearly defined; the definition for care occupancy requires clarification that the care occupancy standards apply whether the care is received directly or indirectly through care facility management; and the current exemption for dwelling units potentially allows for the unintended exemption of buildings in which residents receive special or supervisory care based on the physical layout rather than the actual use. Justification / Explanation Recommended by the Vulnerable Occupancies Technical Advisory Committee [D-REC 1]. The proposed harmonization with the model National Building Code definitions, as supplemented by commentary, will reduce the ambiguity in the determination of the appropriate classification for buildings where occupants receive care or treatment and thereby provide for improved clarity in application and enforcement. Cost / Benefit Implications No cost implications. Enforcement Implications Improved clarity in application and enforcement. Who is Affected Building owners/operators, designers, builders, and enforcement authorities. Objective-Based Analysis Proposed changes relate to Division A. Objective and functional statements are available only for Division B.

Provision Objective Functional Statement

Ministry of Municipal Affairs and Housing Ontario s Building Code ONTARIO ONLY PROPOSED CHANGE TO THE 2012 BUILDING CODE CHANGE NUMBER B-03-02-01 CODE REFERENCE Div. B/3.2.2.44, 3.2.2.46., 3.2.2.47., 3.2.4.8., 3.2.5.13., 3.2.6.8. DESCRIPTION OF PROPOSED AMENDMENT Enhanced fire safety requirements for retirement homes regulated by the Retirement Homes Act, when classified as residential occupancies by the Building Code. Those retirement homes classified as care occupancies by the Building Code will continue to be regulated through the care occupancy requirements. EXISTING 2012 BUILDING CODE PROVISION(S) 3.2.2.44. Group C, up to 4 Storeys, Noncombustible Construction (1) (2) The building referred to in Sentence (1) shall be of noncombustible construction, and, (a) except as permitted by Sentence (3), floor assemblies shall be fire separations with a fire-resistance rating not less than 1 h, (b) mezzanines shall have a fire-resistance rating not less than 1 h, (c) roof assemblies shall have a fire-resistance rating not less than 1 h, and (d) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. 3.2.2.46. Group C, up to 3 Storeys, Increased Area (1) (2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible construction used singly or in combination, and, (a) except as permitted by Sentences (3) and (4), floor assemblies shall be fire separations with a fire-resistance rating not less than 1 h, (b) mezzanines shall have a fire-resistance rating not less than 1 h, (c) roof assemblies shall have a fire-resistance rating not less than 1 h, and (d) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. 3.2.2.47. Group C, up to 3 Storeys (1). (2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible construction used singly or in combination, and, (a) except as permitted by Sentences (3) and (4), floor assemblies shall be fire separations with a fire-resistance rating not less than 45 min, (b) mezzanines shall have, if of combustible construction, a fire-resistance rating not less than 45 min, and (c) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly. 3.2.4.8. Signals to Fire Department

(1) If a fire alarm system is required to be installed and a single stage system is provided, the system shall be designed to notify the fire department in conformance with Sentence (4) that an alarm signal has been initiated in, (a) a Group A occupancy having an occupant load more than 300, (b) a Group B occupancy, (c) a Group F, Division 1 occupancy, (d) a building regulated by the provisions of Subsection 3.2.6., or (e) a building containing interconnected floor space required to conform to Articles 3.2.8.3. to 3.2.8.11. 3.2.5.13. Automatic Sprinkler Systems (1) Except as permitted by Sentences (2) to (4), an automatic sprinkler system shall be designed, constructed, installed and tested in conformance with NFPA 13, Installation of Sprinkler Systems. (2). (3) NFPA 13D, Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, is permitted to be used for the design, construction, installation and testing of an automatic sprinkler system installed in a building of residential occupancy that contains not more than two dwelling units. 3.2.6.8. Voice Communication System (1) A voice communication system conforming to Article 3.2.4.23. shall be provided in a building if, (a) the floor of the top storey is more than 36 m above grade, or (b) a floor area or part of a floor area located above the third storey is designed or intended for use as a Group B, Division 2 or 3 occupancy. PROPOSED CODE CHANGE Add new Clauses 3.2.2.44.(1)(e), 3.2.2.46.(2)(e), 3.2.2.47.(2)(d): 3.2.2.44. Group C, up to 4 Storeys, Noncombustible Construction (1) (2) The building referred to in Sentence (1) shall be of noncombustible construction, and, (a) except as permitted by Sentence (3), floor assemblies shall be fire separations with a fire-resistance rating not less than 1 h, (b) mezzanines shall have a fire-resistance rating not less than 1 h, (c) roof assemblies shall have a fire-resistance rating not less than 1 h, (d) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly, and (e) retirement homes regulated by or under the Retirement Homes Act shall be sprinklered. 3.2.2.46. Group C, up to 3 Storeys, Increased Area (1) (2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible construction used singly or in combination, and, (a) except as permitted by Sentences (3) and (4), floor assemblies shall be fire separations with a fire-resistance rating not less than 1 h, (b) mezzanines shall have a fire-resistance rating not less than 1 h, (c) roof assemblies shall have a fire-resistance rating not less than 1 h, (d) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly, and (e) retirement homes regulated by or under the Retirement Homes Act shall be sprinklered.

3.2.2.47. Group C, up to 3 Storeys (1) (2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible construction used singly or in combination, and, (a) except as permitted by Sentences (3) and (4), floor assemblies shall be fire separations with a fire-resistance rating not less than 45 min, (b) mezzanines shall have, if of combustible construction, a fire-resistance rating not less than 45 min, (c) loadbearing walls, columns and arches shall have a fire-resistance rating not less than that required for the supported assembly, and (d) retirement homes regulated by or under the Retirement Homes Act shall be sprinklered. Add new clause 3.2.4.8.(1)(f): 3.2.4.8. Signals to Fire Department (1) If a fire alarm system is required to be installed and a single stage system is provided, the system shall be designed to notify the fire department in conformance with Sentence (4) that an alarm signal has been initiated in, (a) a Group A occupancy having an occupant load more than 300, (b) a Group B occupancy, (c) a Group F, Division 1 occupancy, (d) a building regulated by the provisions of Subsection 3.2.6., (e) a building containing interconnected floor space required to conform to Articles 3.2.8.3. to 3.2.8.11., or (f) a building containing a retirement home regulated by or under the Retirement Homes Act. Modify Sentences (1) and (3): 3.2.5.13. Automatic Sprinkler Systems (1) Except as permitted provided by Sentences (2) to (4), an automatic sprinkler system shall be designed, constructed, installed and tested in conformance with NFPA 13, Installation of Sprinkler Systems. (2) (3) NFPA 13D, Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, is permitted to be used for the design, construction, installation and testing of an automatic sprinkler system installed in a building of residential occupancy that contains not more than two dwelling units, except that a minimum 20 minute water supply is required for sprinkler systems in buildings containing retirement homes regulated by or under the Retirement Homes Act. Add new Clause 3.2.6.8.(1)(c): 3.2.6.8. Voice Communication System (1) A voice communication system conforming to Article 3.2.4.23. shall be provided in a building if, (a) the floor of the top storey is more than 36 m above grade, (b) a floor area or part of a floor area located above the third storey is designed or intended for use as a Group B, Division 2 or 3 occupancy, or (c) a floor area or part of a floor area located more than 18 m above grade is designed or intended for use as retirement home regulated by or under the Retirement Homes Act. RATIONALE FOR CHANGE Problem / General Background

Retirement homes when not classified as care occupancies are considered as residential occupancies. Such buildings are therefore not subject to the same level of fire safety requirements as care occupancies up to a certain building size. Justification / Explanation Recommended by the Vulnerable Occupancies Technical Advisory Committee [FCE-REC 3]. The Technical Advisory Committee recognized that residents of retirement homes regulated by or under the Retirement Homes Act in buildings that are currently classified as residential occupancies are vulnerable to fire due to age and frailty and all such facilities should be subject to enhanced fire safety beyond the current standards for residential occupancies. Cost / Benefit Implications Enhanced fire safety for vulnerable occupants. Additional cost due to the requirements of sprinklers and other proposed fire safety features. Enforcement Implications No enforcement implications are anticipated. Who is Affected Building owners/operators, designers, builders, and enforcement authorities. Objective-Based Analysis Provision Objective Functional Statement Div. B/3.2.2.44.(2)(e), 3.2.2.46.(2)(e), 3.2.2.47.(2)(d), 3.2.4.8.(1)(f), 3.2.6.8.(1)(c) All new Sentence 3.2.5.13.(3) Fire Safety / Fire Protection Sentence 3.2.5.13.(3) [F02, F81, F82-OP1.2] [F-02, F81, F82-OS1.2]

Ministry of Municipal Affairs and Housing Ontario s Building Code ONTARIO ONLY PROPOSED CHANGE TO THE 2012 BUILDING CODE CHANGE NUMBER B-09-10-01 CODE REFERENCE Div. B/9.10.20.6. DESCRIPTION OF PROPOSED AMENDMENT Enhanced fire safety requirements for retirement homes regulated by the Retirement Homes Act, when classified as residential occupancies by the Building Code. Those retirement homes classified as care occupancies by the Building Code will continue to be regulated through the care occupancy requirements. EXISTING 2012 BUILDING CODE PROVISION(S) None PROPOSED CODE CHANGE Add new Article 9.10.20.6.: 9.10.20.6. Automatic Sprinkler Systems (1) Retirement homes regulated by or under the Retirement Homes Act shall be sprinklered in accordance with Sentence 9.10.1.3.(8). RATIONALE FOR CHANGE Problem / General Background Retirement homes when not classified as care occupancies are considered as residential occupancies. Such buildings are therefore not subject to the same level of fire safety requirements as care occupancies up to a certain building size. Justification / Explanation Recommended by the Vulnerable Occupancies Technical Advisory Committee [FCE-REC 3]. The Technical Advisory Committee recognized that residents of retirement homes regulated by or under the Retirement Homes Act in buildings that are currently classified as residential occupancies are vulnerable to fire due to age and frailty and all such facilities should be subject to enhanced fire safety beyond the current standards for residential occupancies. Cost / Benefit Implications Enhanced fire safety for vulnerable occupants. Additional cost due to the requirements of sprinklers.

Enforcement Implications No enforcement implications are anticipated. Who is Affected Building owners/operators, designers, builders, and enforcement authorities. Objective-Based Analysis Provision Div. B/9.10.20.6. new Objective Functional Statement