Focus 3. Rugged and Robust. Conveyor Rugged. Focus 3. Focus Chassis. Overview

Similar documents
Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

August SECO DC DRIVES. Table of Contents

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

A1000 Cheat Sheet (Open Loop Vector)

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Installation and Operating Manual

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Speed Control Relays SX2

SX460. Generator Automatic Voltage Regulator Operation Manual

Installation and Operating Manual

Installation and Operating Manual

LEESON ELECTRIC CORPORATION GRAFTON, WI U.S.A. TELEPHONE (262) FAX (262)

INTRODUCTION TO RATIOTROL

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

3753 en /b VE/B - VE/RG Va V riable speed drives

AC and DC Drive System Installation Information

Analog Servo Drive 25A8

Kit Watt Audio Amplifier

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

PowerFlex Dynamic Braking Resistor Calculator

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Single Phase Soft Starter

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

32VFD Variable Frequency Drives for Centrifugal Chillers

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Contents. Document information

Automatic Voltage Regulator User s Manual

SECTION VARIABLE FREQUENCY DRIVES

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

ETZGAR CONVEYOR COMPANY Controls Section v12.05

MC1000 Series Installation and Operation Manual

MDC Series

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Number 1 in efficiency

SINGLE PHASE DC DRIVES

GT Sensors Precision Gear Tooth and Encoder Sensors

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

3FBD DC Motor Drive User Manual

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Centro-Matic Automatic Lubrication Systems System Controls

PSR The compact range Description

Telefon (+45) Telefax (+45) Installation and operating manual

Specifying a Variable Frequency Drive s

FREQUENCY CONTROLLED AC MOTOR DRIVE

Research RF Sputtering Packages

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

What Is Regeneration?

SJ200 Series Inverter Quick Reference Guide

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SPEED CONTROL SYSTEM

Variable Transformers Product Design & Engineering Data

Digi-Motor Installation Guide

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Electric Rotary Actuator - On/Off or programmable control actuator

Power Supplies 3. SDN-P DIN Rail Series

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

T7079A,B Solid State Remote Temperature Controllers

EET272 Worksheet Week 9

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Softstarters Type PSR

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Diesel Engine Driven Generators Page 1 of 6

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

GPD 506/P5 Start-up Procedure and Checklist

SPEEDMASTER MICRO SERIES COMPACT INVERTERS

BLY17MDA Series. 24V, 10A Brushless Controller/Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Circuit Breakers. Next Generation of Protection Capabilities

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Safety Relays ESM/ESM-F

Reliance Electric GV3000/SE Industrial AC Drive

Application Note AN-SERV-006

Rotary Phase Converters

GLOLAB Two Wire Stepper Motor Positioner

IO-RM3 3-Stage Relay Module

Technical Guide No High Performance Drives -- speed and torque regulation

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Distribution Dry Type Transformers

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Transcription:

www.emersonct.com Rugged and Robust Overview The is a single-phase analog drive for DC motors with power ranges from 1/4 to 5 HP. Years of proven engineering design matched with surface mount technology make this newest Focus product rugged and reliable. Customer feedback guided the development of the. Many features that were typically available only as options are now standard, expanding its versatility and simplifying installation. Control Techniques provides flexibility. You can stock the complete product line with the four chassis units (two regenerative and two nonregenerative) and two enclosure kits. Conveyor Rugged Analog DC Drive 1/4 to 5 HP, 1 phase, 115-230 VAC Non-regen and Regen models Isolated control circuit (Regen) NEMA 4/12 or Chassis Tachometer or armature feedback Complete Motor Solutions Focus Chassis 90 F3R2C F3N5C F3N2C F3R5C

1-800-893-2321 Feature Performance Advantage Surface mount design Provides rugged and reliable operation at a costeffective price NEMA 4/12 enclosure as standard Protects the integrity of the drive in tough, demanding environments Regenerative and non-regenerative models available in the same footprint Minimizes machine design variations Jumper programmable for: Voltage rating (115-230 VAC) Frequency (50 / 60 Hz) Speed or torque control Tachometer or armature feedback Inherent flexibility in the drive design meets numerous customer requirements with a minimal inventory of drive models and options Independent acceleration and deceleration rates Adaptable to many machine and process speed control requirements Speed and current loop stability adjustments Precisely matches the drive to the motor dynamics Separately adjustable jog speed Aids the customer in setting up and testing their machine Ratings: SINGLE PHASE INPUT.25 to 1 HP (115 VAC).50 to 5 HP (230 VAC) Non-regenerative Motor Input Output Model Catalog HP AC Amps DC Volts Amps Number Volts Arm Field Arm Field.25 to 1 115 14 90 100 10 1.50 to 2 230 14 180 200 10 1 Chassis F3N2C.25 to 1 115 14 90 100 10 1.50 to 2 230 14 180 200 10 1 NEMA 4/12 F3N2E 3 to 5 230 35 180 200 25 1 Chassis F3N5C 3 to 5 230 35 180 200 25 1 NEMA 4/12 F3N5E Regenerative Motor Input Output Model Catalog HP AC Amps DC Volts Amps Number Volts Arm Field Arm Field.25 to 1 115 16 90 100 10 1.50 to 2 230 16 180 200 10 1 Chassis F3R2C.25 to 1 115 16 90 100 10 1.50 to 2 230 16 180 200 10 1 NEMA 4/12 F3R2E 3 to 5 230 40 180 200 25 1 Chassis F3R5C 3 to 5 230 40 180 200 25 1 NEMA 4/12 F3R5E is available with factory installed modifications. To order choose the drive required from the table below and then add modification suffixes to the catalog number (separated by hyphens). Auto (current/voltage signal) or Manual (speed pot) operation Provides local or remote speed control without an option kit Isolated control circuit (regen) Signal common can be earth grounded and tied directly to other drives without additional isolation Order String F3 X X X-XX-XX Modification 2, etc. Modification 1 C = Chassis, E = Enclosed Drive Horsepower: 2 = 2 HP, 5 = 5 HP N = Non-regen, R = Regen F3 = Product Family 91

www.emersonct.com Terminal Diagram: Terminal Description Pin # Type Notes 1 +24 VDC Power Supply For drive use only 2 Tie Point (motor thermal) No internal connection 3 Run Relay +24 VDC @ 10 ma 4 Relay (N.O.) Run relay contact 5 Relay Common 120 VAC, @ 1A resistive 6 Relay (N.C.) 7 Jog Reference Select +24 VDC, 30k Ohms (Logic Input) (requires run input) 8 Jog Pot Supply Input Analog Input, ±10 VDC (-10 VDC regen only) 9 +10 VDC Reference Supply, 5 ma max 10 Speed Reference Analog Input, ±10 VDC, 20k Ohms 11-10 VDC (regen only) Reference Supply, 5 ma max 12 Circuit Common Circuit common hot to earth ground (non-regen only) 13 Minimum Speed Pot For use with speed pot only 14 Remote Current Limit Pot Wiper input (refer to Input Jumpers JP6 & JP7) 15 Remote Current Limit Pot CW connection Input (refer to Jumpers JP6 & JP7) 16 Auto / Manual Input Logic Input, +24 VDC @ 30k Ohms 17 Current follower Input Analog Input, 4-20 or 1-5 ma 18 Voltage follower Input Analog Input, 200 VDC max 19 DC tachometer Input (-) Analog Input, 160 VDC max 20 DC tachometer Input (+) Circuit common 92

1-800-893-2321 Specifications: Adjustments Maximum Speed 80 to 120% of rated speed Minimum Speed 0 to 30% of maximum speed IR Compensation 0 to 20% of rated voltage Current Limit 0 to 150% of selected range Acceleration 0.3 to 20 seconds Deceleration 0.3 to 20 seconds Jog Speed 0 to 30% of rated speed Dimensions Speed Adjustment Start/Stop Run/Jog Forward/Reverse (Regen Only) Auto/Manual Operator Functions Standard Standard (Enclosed) Customer Supplied (Chassis) Option Kit Option Kit Option Kit Customer Selectable Rated Input Voltage 115 or 230 VAC Control Mode Speed or Torque Output Current Hi / Med / Low / Xlow Armature Voltage Feedback Hi (180) / Lo (90) VDC Tachometer Feedback Hi / Lo Speed Feedback Selector Armature / Tachometer Line Frequency 50 / 60 Hz Current Limit Pot Selector Local / Remote Logic Control Power Speed Potentiometer Speed Regulation (95% load change): Armature Voltage Feedback due to field) Tachometer Feedback (i.e. 5PY) Control 24 VDC 5k Ohms, 2 watts 1% of maximum speed with IR compensation. (does not include drift 0.5% of base speed Drive Operating Conditions NEMA 4/12 Enclosure Standard (Enclosed) Option Kit (Chassis) Altitude 1000m (3,300 ft) Ambient Temperature 0 to 40 C (32 to 104 F) (Enclosed) 0 to 55 C (32 to 131 F) (Chassis) Rated Input Voltage 115-230 VAC ±10% Rated Frequency 48 to 62 Hz Overload Capacity 150% of selected rating Efficiency: Controller (min) 98% Drive (typical) 86% 93

94 Enclosure Option Options Factory Installed Modifications Kits are available as either factory-installed options or field kits. To order factory installed modifications, choose the basic drive required from the ratings table on page 91 and then add modification suffixes (separated by hyphens) to the basic catalog number. Function Description Suffix M.25-1 HP @ 115V M1 Contactor Kits*.50-2 HP @ 230V M2 3-5 HP @ 230V M5.5 HP @ 115 V, 2 HP @ 230V DB2 Dynamic.25 -.33 HP @ 120V, 1.5 HP @ 230V DB4 Braking.75-1 HP @ 230V DB6 Kits.5 HP @ 230V DB7.75-1 HP @ 115V DB1 3 HP @ 230V DB3 5 HP @ 230V DB5 Toggle Run / Jog TSA Switches Auto / Manual TSB Forward / Reverse TSC Signal Signal Isolation Board NS Isolation Feedback AC Tachometer Input Board ACT Speed Pot Ten-Turn Potentiometer TTP * When the M kit is factory installed, UL will not apply. By stocking these two enclosure kits along with the four chassis drives, the distributor can supply all models. The enclosure kits include the speed pot and the start / stop switch pre-wired to a plugon terminal strip and all gasketing required for a NEMA 4/12 rating. 2 HP, non-regen and regen...f3se 5 HP, non-regen and regen...f3le Toggle Switch (F3TS) This kit is used to provide one of the following functions: Run / Jog, Auto / Manual or Fwd / Rev (regen only). It can be mounted in the Focus 1 or enclosure cover, remote operator station (0895-8000), or remotely mounted when used with the chassis drive. The F3TS kit includes the toggle switch, NEMA 4/12 switch boot and connection wires for enclosure cover use. A maximum of three kits may be used with the enclosure cover. M Contactor Kit www.emersonct.com This kit provides a positive disconnect of the motor armature when the controller is stopped, preventing motor rotation in the event of SCR misfire due to line noise. It includes the DB (dynamic braking) poles, an auxiliary normally open (N.O.) contact, all connection wires and a magnetic contactor for mounting in the chassis or enclosed drives. This kit may be required by local and / or national electrical codes. 1 HP, 115 VAC... F3M112 2 HP, 230 VAC... F3M224 5 HP, 230 VAC... F3M524 Dynamic Braking Kit Dynamic braking provides rapid motor stopping by quickly dissipating the stored energy in the rotating motor and load. These kits are designed for use with the contactor kits. The resistors have been sized in accordance with the following NEMA specification for dynamic braking: Three stops in rapid succession with the load inertia equal to the motor inertia then cooling forever. AC Input HP (Typical) DB Kit Catalog Number.25 to.33 F3DB1524 120 VAC.5 F3DB224.75 to 1 F3DB112.5 F3DB0524.75 to 1 F3DB224 240 VAC 1.5 F3DB1524 2 F3DB224 3 F3DB324 5 F3DB524

1-800-893-2321 AC Tachometer Input Board (F3ACT) This option kit allows the to accept AC tachometer feedback. It mounts directly to the Focus 3 control board and accepts a range of 45 to 110 VAC at maximum speed. Signal Isolator Board (F3NSBD) Remote Percent / RPM Speed Meters These meters are used for remote display of the motor speed in RPM (up to 2000 rpm) or percent of maximum speed. Included is a universal calibration board. The 4.5 meter is enclosed in a NEMA 1 steel enclosure suitable for panel or wall mounting. This option is used in applications where isolation is required between an external control signal and the motor controller (which may or may not be at earth ground potential). It can be used to isolate a variety of voltage or current signals (see specifications below) or simply to isolate the speed potentiometer. The potentiometer power supply is included. This option can be mounted inside the cover or panel mounted on a piece of curtis track (included with kit). Because the board has a uni-polar output, it is typically used on single directional applications. Specifications Input Power Control Relay Relay Contacts Isolation Voltage Voltage Ranges Current Ranges Speed Pot Output 17 to 30 VDC @ 50 ma max. (for control circuitry) 24 VDC @ 12.1 ma (JP5 = 24 VDC) 115 VAC @ 20 ma (JP5 = 120 VAC) (qty. 2) Form A, 1A @ 250 VAC 240 VAC line voltage 2000 VAC hi-pot for 1 minute 5, 12, 26, 52, 98 & 208 VDC 180 Ohms/volt 0-5 or 1-5 ma 910 Ohms input impedance 0-20 or 4-20 ma 250 Ohms input impedance 5k Ohms, 2 watts (includes +10 VDC power supply for the pot) 0 to +10 VDC (uni-polar) Percent Speed Meter...2450-9024 RPM Speed Meter...2450-9021 Ten-turn Speed Potentiometer (6160-9001) This ten-turn speed pot provides a vernier scale for precise and repeatable speed setting while a locking tab prevents inadvertent speed changes. It may be mounted in the Focus 1 or enclosure, or in a remote operator station as described above (OPS4N01- PORS) or supplied by the customer. 95