Technique Guide. DBX Inject. Demineralized Bone Matrix with Delivery System.

Similar documents
DBX. Bone Graft Substitute. The osteoinductive power.

Technique Guide. Norian SRS Fast Set Putty. Calcium phosphate bone void filler.

it will set at body temperature, and it will grow. UNIQUE FORMULATIONS

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

Patient Information. Anterior Cervical Discectomy and Fusion Surgery (ACDF).

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Demineralized Bone Matrix: Development of a Process for Optimal Performance. the better approach

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

S YN T H E T I C C A N C E L LO U S B O N E

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Summary of typical bone-graft substitutes that are commercially available

LifeNet Health Presented by James Clagett, PhD., Chief Science Officer LifeNet Health - The Best Keep Secret in Regenerative Medicine

Dental Bone Grafting Options. A review of bone grafting options for patients needing more bone to place dental implants

BONE-GRAFT SUBSTITUTES: FACTS, FICTIONS & APPLICATIONS

Scout Vessel Guard. A hydrogel membrane with exceptional handling characteristics.

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Plasmax Plasma Concentration System BIOLOGICS

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

ClikSTAR - Important facts about your new insulin delivery device.

Lentur Cable System. Surgical Technique

THE EVOLVING ROLE OF BONE-GRAFT SUBSTITUTES

Technology Breakthrough in Spinal Implants (Technical Insights)

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

(English) NEXUS SPINE SPACER SYSTEM

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Don t Let Life Pass You By Because Of Oral Bone Loss

Battery Power Line. Battery-driven power tool system for orthopaedics and traumatology.

cartilage regeneration

Ankle Block. Indications The ankle block is suitable for the following: Orthopedic and podiatry surgical procedures of the distal foot.

Zimmer DeNovo NT Natural Tissue Graft

Instructions for Use. Components of the GENOTROPIN PEN 12

Zimmer Small Fragment Universal Locking System. Surgical Technique

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

ON-Q * Catheters and Introducers

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Degenerative Spine Solutions

HUMULIN (HU-mu-lin) N

How To Prepare and Give a Prefilled Syringe Injection

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding.

Instructions for Use

Knotilus TM. Anchor Instability Repair. Technique Guide

PICC & Midline Catheters Patient Information Guide

Spinal Arthrodesis Group Exercises

PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

BONE-GRAFT SUBSTITUTES: FACTS, FICTIONS & APPLICATIONS

INSULIN INJECTION KNOW-HOW

The information contained in this document is intended for healthcare professionals only.

Achilles Tendon Repair, Operative Technique

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin)

Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:

Tell your doctor about all the medicines you take, including prescription and nonprescription medicines, vitamins, and herbal supplements.

Blood sampling and transportation Standard Operating Procedure

Choosing Bone Graft Substitutes: Filling the Gaps on Evidence and Pricing. September 24, 2014

Heart problems - What are the possible side effects of AVONEX? What is AVONEX? Who should not take AVONEX?

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

Model 450 Mag Horn Ferromagnetic Locator

Get the Facts, Be Informed, Make YOUR Best Decision. Pelvic Organ Prolapse

The Enbrel SureClick autoinjector is a single-use prefilled autoinjector. It contains one 50-mg dose of Enbrel.

HUMULIN 70/30 KwikPen

INJECTION TECHNIQUE. IVF NURSING OFFICE: (301) Darshana (301) Nicole

The OmniPod Insulin Management System

XCM Biologic Tissue Matrix. Regenerative matrix for reinforcement and repair of soft tissue.

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

I-140 Venipuncture for Blood Specimen Collection

PACKAGE LEAFLET: INFORMATION FOR THE USER. VITAMINE B12 STEROP 1mg/1ml Solution for injection / oral solution. Cyanocobalamin

Plasmax Plasma Concentration System for Laparoscopic Roux-en-Y Gastric Bypass

Peripheral Venous Catheter Placement Simulator

Hypodermic Product Catalog. The Basis for Selection of Your Medication Delivery Device Needs

Guidance for implant removal. Straumann Dental Implant System

HUNTER TENDON IMPLANTS

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

Adult Forearm Fractures

DIRECTED UMBILICAL CORD BLOOD AND TISSUE COLLECTION IN THEATRE (CELLCARE)

GeniJet Pipeless Motor Spa Installation

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

A Practical Guide for the selection and use of prefilled Syringes for flushing vascular access devices. Paul Parisien, MedXL inc., Montreal, Canada.

CORNERSTONE TISSUE PARALLEL TISSUE OFFERINGS

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Aspira* Peritoneal Drainage Catheter

Organ, Tissue and Eye Donation: Glossary of Terms

Medications or therapeutic solutions may be injected directly into the bloodstream

#12 Professional Meat Grinders

Integumentary System Individual Exercises

Information for the Patient About Surgical

Transcription:

Technique Guide DBX Inject. Demineralized Bone Matrix with Delivery System.

Table of Contents Introduction DBX Inject Putty 2 Indications and Contraindications 6 Surgical Technique Preparation 7 Delivery Technique 11 Product Information Musculoskeletal Transplant Foundation (MTF) 16 Product Information 17 Synthes

DBX Inject. Demineralized bone matrix with delivery system. The DBX Inject Putty package contains a glass syringe preloaded with DBX Putty and a separate plastic delivery syringe. When the DBX Putty is transferred from the glass syringe to the delivery syringe, it becomes DBX Inject Putty. When using the delivery syringe, DBX Inject Putty may be extruded directly into the operative site. The delivery syringe may be used with a variety of tamps and cannulas, provided separately, but also can be used alone. Caution: The glass syringe is not an applicator and should not be used to deliver tissue to the operative site. DBX Putty is demineralized bone matrix that has osteoinductive potential* and is osteoconductive. It is composed of demineralized bone from human donors in a biocompatible carrier and provided in various forms to meet surgical needs. The demineralized bone powder is produced by the removal of minerals from cortical bone. The DBX Putty carrier, sodium hyaluronate, is a naturally derived material that is biocompatible and biodegradeable, similar to the naturally occurring hyaluronate found in the human body. DBX Putty demineralized bone matrix is nonhemolytic, ensuring compatibility with the surrounding autogenous blood cells. *Note: It is unknown how the osteoinductive potential, measured in the athymic mouse model or the alkaline phosphatase assay, will correlate with clinical performance in human subjects. 2 Synthes DBX Inject Technique Guide

DBX Putty Demonstrated bone formation Osteoconductive and osteoinductive potential Biocompatible inert carrier, ph-balanced, nonhemolytic Exemplary safety AATB-accredited tissue bank, viral inactivation, NAT-tested Stays in place resists movement under irrigation, maintains physical integrity Ready to use, with no mixing or thawing required Delivery system Delivery syringe provides tactile feedback allowing consistent and controlled delivery Optional delivery cannula can be attached to the syringe, for more precise application and access to remote sites Tamp is provided with delivery cannula to extrude remaining material from cannula DBX Putty glass syringe Delivery syringe body Delivery syringe plunger Cannula Tamp Synthes 3

DBX Inject. Demineralized bone matrix with delivery system. Carrier characteristics Sodium hyaluronate is a polysaccharide which occurs naturally in the human body. It plays an essential role in cell proliferation, migration and adhesion, and has been correlated to angiogenesis. 1,2 It also confers positional stability to the tissue. 3 Sodium hyaluronate is proven to be safe. 2 The DBX Putty carrier, sodium hyaluronate, is similar to the naturally occurring hyaluronate found in the body. MTF uses high-quality medical grade sodium hyaluronate, produced through fermentation processes under good manufacturing practice (GMP) guidelines. The DBX Putty formulation has been specifically designed to have the physiological normal ph of 7.2, similar to human blood. 1. Alicia Orlidge and Patricia D Amore. Cell Specific Effects of Glycosamino-glycans on the attachment and Proliferation of Vascular Wall Components. Microvascular Research. 31: S41 S43, 1986. 2. J.R.E. Fraser and T.C. Laurent. Turnover and Metabolism of Hyaluronan. The Biology of Hyaluronan. Evered D. and Whelan J., eds. Wiley, Chichester (Ciba Foundation Symposium 143) S41 S59, 1989. 3. Arthur Gertzman, Moon Hae Sunwoo. A Pilot Study Evaluating Sodium Hyaluronate as a Carrier for Freeze-dried Demineralized Bone Powder. Cell and Tissue Banking. 2: S87 S94, 2001. 4 Synthes DBX Inject Technique Guide

Demonstrated bone formation Osteoinductive potential Each lot of DBX Putty is validated in vivo or in vitro to verify its osteoinductive potential. Osteoconductivity The variety of DBM particle sizes provides an osteoconductive matrix. Athymic mouse Bone Formation Histologic verification Osteoinductivity study An athymic mouse study, based on the Urist intramuscular model, confirmed histologically that DBX Putty has osteoinductive potential. 4 Bone content of DBX Putty % Bone (by weight) 31% Bone Particle Diameter 212 850 μ New Bone Notes: High demineralized bone content maximizes the amount of bone placed in the surgical site. Animal test results may not necessarily be indicative of clinical performance. 4. M. Urist. Bone Formation by Autoinduction. Science. 1965; 150: 893 899. Synthes 5

Indications and Contraindications Indications DBX Inject Putty is intended for use as a Demineralized Bone Matrix for voids or gaps that are not intrinsic to the stability of the bony structure. DBX Inject Putty is indicated for treatment of surgically created osseous defects or osseous defects created from traumatic injury. DBX Inject Putty can be used alone in the posterolateral spine. DBX Inject Putty can also be used as an extender in the spine with autograft or allograft. DBX Inject Putty can be used with bone marrow. DBX Inject Putty is for single patient use only. DBX Inject Putty can be used alone in the pelvis and extremities. DBX Inject Putty can also be used as an extender in the pelvis and extremities with autograft or allograft. DBX Inject Putty can be used with bone marrow. DBX Inject Putty is for single patient use only. Contraindications* DBX Inject Putty is not intended to provide structural support of the bone during the healing process. DBX Inject Putty is also contraindicated in the following circumstances: Incomplete maxillofacial skull growth Severe vascular or neurological disease Fever Uncontrolled diabetes Severe degenerative bone disease Pregnancy Hypercalcemia Renal-compromised patients History of or active Pott s disease Osteomyelitis at the surgical site Inability to cooperate with and/or comprehend postoperative instructions * Please see the Directions for Use for complete description of indications, contraindications, warnings, and precautions. 6 Synthes DBX Inject Technique Guide

Preparation 1 Planning Select the appropriate volume of DBX Inject Putty and appropriate cannula and tamp size for the procedure. Note: A cannula and tamp is not necessary if delivering material directly from the delivery syringe. The glass syringe is not an applicator. Synthes 7

Preparation 2 Open outer tray Using aseptic technique, remove the inner tray containing DBX Putty from the outer tray by peeling back the foil lid. Note: DBX Putty is aseptically packaged into a sterile tray. 8 Synthes DBX Inject Technique Guide

3 Open inner tray Remove the glass syringe containing DBX Putty from the package by peeling back the foil lid of the inner tray. Caution: DBX Putty should not be extruded into the operative site from the glass syringe. Material should be dispensed into the delivery syringe or extruded into a sterile basin. Take care when opening the DBX Putty package to avoid dropping the glass syringe. Synthes 9

Preparation 4 Transfer DBX Putty to delivery syringe Remove the cap from the glass syringe and place the open end into the back of the delivery syringe body. Take care to apply gentle, even force to the plunger when extruding DBX Putty from the glass syringe. Extreme force applied to the plunger may cause the glass syringe to break. Dispense all the DBX Putty by backfilling the delivery syringe body. Remove and dispose of the glass syringe appropriately. 10 Synthes DBX Inject Technique Guide

Delivery Technique 5 Insert plunger and deliver material Once the DBX Putty has been transferred completely into the delivery syringe body, place the threaded plunger into the delivery syringe body. Note: Delivery to the operative site can be achieved directly from the delivery syringe, or a cannula can be attached to the delivery syringe for more precise application or access to remote areas. When the DBX Putty is transferred from the glass syringe to the delivery syringe, it becomes DBX Inject Putty. Synthes 11

Delivery Technique 5. Insert plunger and deliver material continued Small volumes of DBX Inject Putty may be delivered with precise control by rotating the threaded plunger in a clockwise direction. Each full rotation of the plunger results in the delivery of 0.5 cc of tissue. Large volumes of DBX Inject Putty may be delivered at a faster rate by advancing the threaded plunger into the syringe. Each click indicates that 0.5 cc of tissue has been dispensed. Caution: If resistance is encountered, pull the threaded plunger back slightly and rotate the knob one-half (1/2) turn counterclockwise to relieve the pressure, then continue delivery. Calibration marks on the delivery syringe are in 1 cc increments. 12 Synthes DBX Inject Technique Guide

6 Attach delivery cannula (optional) Using aseptic technique, peel open the cannula and tamp packaging and remove the cannula and tamp. Attach the cannula to the delivery syringe by fully inserting it into the tip and rotating one-quarter ( 1 /4) turn clockwise to lock into place. Synthes 13

Delivery Technique 6. Attach delivery cannula (optional) continued With the cannula securely attached, begin delivery of DBX Inject Putty as described in Step 5. Notes: Always use a backfill technique. Begin injection or delivery and slowly withdraw the cannula as fill is achieved. DBX Inject Putty with or without cannula is NOT a puncturing device. DBX Inject Putty should be extruded into operative site after surgical approach from the sterile plastic syringe or cannula. 14 Synthes DBX Inject Technique Guide

7 Insert tamp To deliver remaining DBX Inject Putty in the cannula, remove the cannula from the delivery syringe and insert the tamp through the cannula. Synthes 15

Musculoskeletal Transplant Foundation (MTF) Synthes has partnered exclusively with the Musculoskeletal Transplant Foundation (MTF) for over 10 years to provide high quality tissue for patients. Although there are national standards for tissue banks, they only set a baseline for the industry. Beyond that, regulations leave a lot to interpretation, so standards vary significantly from tissue bank to tissue bank. MTF offers safe allografts processed from among the most carefully selected donors. MTF s standards are set by their Medical Board of Trustees more than 40 surgeons from world-renowned academic institutions. Directed by Surgeons MTF utilizes a Medical Board of Trustees comprised of more than forty surgeons from world-renowned academic institutions. MTF s board sets standards, which are among some of the most stringent in the industry. Selecting the Ideal Donor MTF s extensive network of participating organ procurement organizations ensures that MTF has access to a broad selection of qualified donors. MTF holds itself to stringent standards for donor selection and processing criteria. MTF defers more donors than they accept. MTF Donor Deferral Rate > 97% deferred < 3% accepted Preserving and Protecting Tissue Integrity MTF s approach ensures a high level of safety, without compromising biological and mechanical integrity. MTF has developed and validated several tissue cleaning technologies to provide safe and high quality allograft bone. Allograft bone processed by MTF may result in improved incorporation in humans when compared to allograft bone processed from other sources based on results of in vivo testing*. Since MTF s inception, MTF has maintained an exemplary safety record distributing more than 5 million allografts from more than 90,000 donors. *Dunn M.G, 2008. Effect of Allograft Bone Processing on Structural Cortical Grafts: A Comparison of three proprietary processing Methods. 16 Synthes DBX Inject Technique Guide

Product Information DBX Inject Demineralized Bone Matrix Volume (cc) 068025 2.5 068050 5.0 068100 10.0 Delivery Cannulas and Tamps, sterile (1 ea./pkg.) (Trauma) 03.702.400.97S 8 gauge x 10 cm 03.702.403.97S* 8 gauge x 19 cm 03.702.401.97S 10 gauge x 10 cm 03.702.402.97S 12 gauge x 5 cm (Spine) 03.702.400.99S 8 gauge x 10 cm 03.702.403.99S* 8 gauge x 19 cm * Recommended for use with paste only. Synthes 17

Available through Synthes 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order call: (800) 522-9069 Fax: (877) 534-1560 www.synthes.com Processed by Musculoskeletal Transplant Foundation 125 May Street Edison, NJ 08837 Telephone: (732) 661-0202 Fax: (732) 661-2298 MTF tissue forms & products are protected by one or more issued or licensed US patents. A list of patents on available tissues and related technologies may be found on the MTF Website www.mtf.org. 2010 Synthes, Inc. or its affiliates. All rights reserved. Synthes is a trademark of Synthes, Inc. or its affiliates. Printed in U.S.A. 3/13 J9558-C DBX is a registered trademark and DBX Inject is a trademark of Musculoskeletal Transplant Foundation.