PRO 2 Sensor (IHT) Conford Electronics. Installation and Users Manual. Conford Electronics 1 Hillview, Conford Liphook, Hampshire.

Similar documents
Duct Humidity Transmitter

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Analytical Instruments Smart Analyzer 90 Type SMA

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

HMI display Installation Guide

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Use A Ds340 (Dsp)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

PBX Series Quick Fit Connector Bimetallic Steam Traps

Digital inductive conductivity transmitter

PART 1 - INTRODUCTION...

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Pressure transmitter For general industrial applications Model A-10

Drayton Digistat +2RF/+3RF

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

ADM1TE 5/30A DIN rail single phase two wire energy meter

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Modular I/O System Analog and Digital Interface Modules

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Mini USB and USB 2.0-IP67 Connector System

Threaded Inline Air Heaters

TMS TANK MANAGEMENT SYSTEM

3/2-way Solenoid Valve, direct-acting, NC or NO

J TB/TW Temperature limiter, temperature monitor

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Mounting Instructions. Torque Transducer. A en

Cross-beam scanning system to detect slim objects. 100 mm in

WD-AMX Water Detection Controllers

Manual Ranging MultiMeter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Instruction Manual Differential Pressure Transmitter

Problem / Solution. The problem:

How To Use A Flowmeter

Vario-Series Accessories

Triple Waveband Infra-Red Flame Detection

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Proportional pressure regulators VPPE

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

HERZ-Thermal Actuators

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Technical data sheet TDS0070

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Oil and Coolant Circulating Heating System. Model - OCSM

Maintenance Guide IM/AZ20M EN Rev. C. Endura AZ20 series probe Combustion oxygen monitor

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Plastic tube flowmeters Series PT/PS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

CARING FOR YOUR WATER HEATER

TS93 EMR T/PT/TDE. Surface applied door closer

Installation Instructions

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Toroidal Conductivity Sensor

Givare NC-SRS 280 och 880

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Model 1756 Test Lead Kit

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

MIC-WKT and MIC-WKT-IR

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Installation Questions

CO2 Alarm. Operation. Application

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Current Monitoring Kit QUICK START GUIDE

Material test chamber with mechanical convection

Technical Data. Dimensions

Typical Aluminum GFM Mass Flow Meter

Compact pressure switch Flameproof enclosure Ex d Model PCA

ATL Fuel Level Sender Probes

TIG INVERTER INSTRUCTION MANUAL

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

G670 Intermittent Pilot Ignition Controls

Data Sheet PS1B Pressure Switch

ST Series POWER SUPPLIES USER INSTRUCTIONS

Current Monitoring Kit

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Rosemount 333 HART Tri-Loop

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Technical Specification. Generating Set with Waukesha engine burning natural gas

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Electro-pneumatic control valves

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Transcription:

Conford Electronics PRO Sensor (IHT) Installation and Users Manual V.c Conford Electronics Hillview, Conford Liphook, Hampshire. GU QW Phone: + () Web site: www.confordelec.co.uk email: contact@confordelec.co.uk

INDEX Subject Page Warnings and Cautions.. Introduction to the PRO Sensor (IHT). Installation general.. Mechanical installation.. Mechanical assembly. Electrical installation... Wiring diagram Calibration Calibration graphs... - Sensor characteristics Maintenance Specification. Parts list Labels.

Warnings and Cautions ONLY QUALIFIED PERSONNEL WHO THOROUGHLY UNDERSTAND THE OPERATION OF THIS EQUIPMENT AND ANY ASSOCIATED MACHINERY SHOULD INSTALL, START-UP OR ATTEMPT MAINTENANCE OF THIS EQUIPMENT. NON-COMPLIANCE WITH THIS WARNING MAY RESULT IN PERSONAL INJURY AND/OR EQUIPMENT DAMAGE NEVER WORK ON ANY CONTROL EQUIPMENT WITHOUT FIRST ISOLATING ALL POWER SUPPLIES FROM THE EQUIPMENT. WARNING CAUTION This equipment was tested before it left our factory. However, before installation and start-up, inspect all equipment for transit damage, loose parts, packing materials etc. Due consideration must be given to environmental conditions of installation for safe and reliable operation. STATIC ELECTRICITY This equipment contains electrostatic discharge (ESD) sensitive parts. Observe static control precautions when handling, installing and servicing this product EMC & Safety tested to relevant BS EN Standards CAUTION The user must be aware that, if this equipment is used in a manner not specified by Conford Electronics, the protection provided by the equipment may be impaired INSTALLATION This equipment is designed for indoor use only Installation category II Pollution Degree in accordance with IEC CAUTION Oxygen sensor body may be hot, even when boiler is off CAUTION Do not bypass IHT unit by connecting cable directly to the oxygen sensor. This will result in damage to the equipment. The IHT unit should on no account be removed from the PRO Sensor; these are a calibrated, matched pair. Issue.c (March ) PROSensor (IHT) Product manual Page

PROSensor (IHT) General Measuring depleted Oxygen levels in the flue gas has long been recognised as one of the best measures of combustion conditions and is an essential pre-requisite to reducing fuel costs and improving environmental performance of new and existing industrial boiler plant. The Conford Electronics PRO Sensor (IHT) combines field proven PRO Sensor technology with an intelligent In-head transmitter (IHT) to provide a low cost and easily installed oxygen monitoring system. The design eliminates the need for an external signal-conditioning unit (normally housed in a separate panel). This enables a direct connection to the sensor thus providing optimum EMC immunity, high signal integrity, and low cost installation and servicing. The IHT unit is coupled directly to a high stability zirconium oxygen sensor cell and converts the output to an industry standard process signal (-ma). Energy efficiency and the environment The optimum air to fuel ratio is critical to efficient energy conversion and to minimising noxious emissions from boiler plant. Burning less fuel also means producing less CO. Hysteresis, linkage wear, cable and control failures are some of the typical causes of significant fuel wastage, and hence poor environmental performance. Safety Maintaining the correct air to fuel ratio reduces the risk of flame impingement and resultant failure of boiler tubes. Combustion efficiency tests carried out when the boiler is routinely serviced do not protect against interim faults developing, or catastrophic component failure with the risk of a serious explosive incident. Plant performance, outages and damage Poor combustion accelerates the formation of carbon deposits on the heat transfer surfaces, reducing boiler efficiency. These deposits can also cause thermal stress, which may result in costly boiler repairs and unscheduled outages. Continuous monitoring of oxygen levels can therefore greatly reduce maintenance costs. Issue.c (March ) PROSensor (IHT) Product manual Page

Installation All electrical work to be carried out by qualified personnel in accordance with Local wiring regulations General The Conford Electronics PRO Sensor (IHT) installation kit includes a DIN rail mountable preset dc power supply (required for its internal heater), probe assembly, flue flange, gasket and cable assemblies pre conduited for ease of installation. The flue flange is welded to the boiler flue as detailed below. A flue gas sampling probe is screwed into the flange ensuring correct orientation, and locked in place with a locknut. This part of the installation is permanent. The O sensor assembly bolts on to the probe body, remote from the flue, (this considerably eases maintenance). The In-head transmitter (IHT) is directly mounted to, and should not be separated from, the sensor. The -ma signal output is scaled to.% -.% O. The power supply is DIN rail mountable, generally positioned in the burner panel. (wired as per drawing.) Fitting the flange and probe body in the duct The oxygen sensors will be normally located in the flue duct immediately after the point where the flue gasses exit the boiler. The flue flange should be welded on to the top surface of the duct, taking care not to overheat and deform the flange. The probe body should be mounted as detailed below. The duct should be insulated to avoid radiant heat damaging the cabling if flue gas temperatures in excess of o C are anticipated. When welding the flue flange to the duct wall, the threads should be protected with temporary blanking plugs available from Conford Electronics. The probe body is to be screwed in and locked with the locknut provided, ensuring the correct orientation as shown overleaf. The oxygen sensor assembly is then mounted on the sensormounting flange with gasket, off Mx setscrews and lockwashers provided. Issue.c (March ) PROSensor (IHT) Product manual Page

Mechanical installation Flue temp transmitter housing (Do not separate) Oxygen sensor Transmitter housing (Do not separate) Sensor assembly ZR/ Gasket ZR/ Probe Locknut Thermocouple assembly ZR/ Cont. mm (Gas tight) Welded flue flange plate ZR/ Flue duct wall Ensure adequate clearance for full G/ thread Probe body & sensor flange Note probe orientation ZR/ Flue gas flow off G/ ports for thermocouple and flue gas test probe Flue flange plate details Issue.c (March ) PROSensor (IHT) Product manual Page

Mechanical assembly Gasket ZR/ Transmitter Housing (Do not separate from sensor) Oxygen Sensor Assembly ZRN/ Locking Nut Probe Assembly ZR/ Flue Flange Plate ZR/ Flue Temperature Probe Assembly ZR/ Transmitter Housing (Do not separate) Issue.c (March ) PROSensor (IHT) Product manual Page

Electrical installation Pre conduited m cable sets fitted with IP plug and socket terminations are supplied with the Conford Electronics PRO Sensor (IHT) and should be installed as per the wiring installation diagram. Mains connection The power supply should be installed with a double pole, thermal magnetic circuit breaker. It should meet the relevant requirements of IEC - and IEC -. The circuit breaker should be marked to indicate it as the disconnecting device for the PRO Sensor, and should be located as close as possible to the supply (typically this would be in the boiler control panel). The protective earth of the power supply must be connected to the main protective earth. Note: No signalling wiring should be allowed to run parallel with any mains cabling, unless separated by at least mm. Where signalling and mains have to cross, this should be done at right angles. See wiring diagram (over) for details. Issue.c (March ) PROSensor (IHT) Product manual Page

A B C D E F RevNo Revision note Date Signature Checked Bk was, R was, Bk was, R was, R was, Bk was // SP -ma output (using heater supply). Vdc Supply for heater Flue temp -ma signal (+) Panel mounted heater power supply (.Vdc) Vdc Supply for heater Oxygen -ma signal (+) Flue temp -ma signal (-) Oxygen -ma signal (-) Flue temp -ma signal (+) Oxygen -ma signal (+) - Vac Flue temp -ma signal (-) Oxygen -ma signal (-) -ma output (using external supply) to Vdc supply Designed by Checked by Approved by - date Filename Date Scale Edition Sheet / A B C D E F (-ma supply) (-ma output) (-ma supply) (-ma output) - Vac IHT Oxygen sensor assembly Thermocouple assembly (-ma supply) (-ma output) (-ma supply) (-ma output) Bk R R Bk Scr R Bk Scr Pin out from IHT ) (-ma) Signal supply ) (-ma) Signal output Screen ) V Heater supply ).Vdc Heater supply Flue temp probe (-ma) - deg Pin out from Flue temp Tx ) (-ma) Signal supply ) (-ma) Signal output Screen Note: max loop impedance = Ohms @ Vdc +V IHT Oxygen Sensor (-ma). -. % - V N L Bk R R Bk Scr R Bk Scr Panel mounted heater power supply (.Vdc) +V - V. Vdc Supply for heater Vdc Supply for heater Note: max loop impedance = Ohms @ Vdc Boiler flue N L + - JG PM // IHT Electrical inst // NTS Conford Electronics Conford, Liphook Hampshire GU QW Electrical installation PROSensor (IHT) & Flue temp Installation drg

Calibration check In common with all process monitoring and control equipment, the calibration of the PRO Sensor should be checked after installation with a calibrated combustion analyser. Using the test port provided in the flue flange, O levels should be checked against the values displayed at both low and high burner firing rates once the boiler and sensor have got to normal operating temperature. Note: The PRO Sensor sensor reads the wet oxygen level and that most portable flue gas analysers read the dry oxygen level. This will result in slightly differing measured values, the wet measurement being typically ½ to % less than the dry reading portable instrument, - dependent upon fuel type. Refer to the appropriate graph below NORTH SEA GAS % OXYGEN / %CARBON DIOXIDE %CO (dry) %O (dry) %O (wet) % EXCESS AIR Issue.c (March ) PROSensor (IHT) Product manual Page

GAS OIL %CO (dry) % OXYGEN / %CARBON DIOXIDE %O (dry) %O (wet) % EXCESS AIR MEDIUM & LIGHT OIL %CO (dry) % OXYGEN / %CARBON DIOXIDE %O (dry) %O (wet) % EXCESS AIR Issue.c (March ) PROSensor (IHT) Product manual Page

HEAVY OIL %CO (dry) % OXYGEN / %CARBON DIOXIDE %O (dry) %O (wet) % EXCESS AIR COAL %CO (dry) % OXYGEN / %CARBON DIOXIDE %O (wet) %O (dry) % EXCESS AIR Issue.c (March ) PROSensor (IHT) Product manual Page

Sensor characteristic charts IHT ma Output % Oxygen.. ma signal IHT - ma characteristics Load resistance (ohms). Supply voltage Issue.c (March ) PROSensor (IHT) Product manual Page

Maintenance As with any safety equipment, it is essential for the satisfactory, long-term operation of the system that a comprehensive maintenance agreement is in place. The Conford Electronics PRO Sensor (IHT) has been developed specifically for ease of maintenance. Many of the components are recyclable, and the service exchange units, precalibrated, set a new benchmark for ease of servicing and low cost of ownership. Zirconium oxygen sensors have a finite life, it is recommended that they are checked for accuracy and response time every months. The life span is dependent on fuel type used and contaminants present in the flue gas. (Nominally this can be considered to be to months in natural gas) Replacement is necessary when ambient oxygen levels are reading % or less, or the response time for the sensor becomes excessive. A low cost service exchange facility is available from Conford Electronics. The sensor is resistant to residue-free gaseous hydrocarbons and light fuel oil in line with DIN when used as fuel. During its total lifetime the sensor is resistant to aggressive exhaust gases like CO, CO, NO, NO x and low temperature carbonisation gas. A reduced lifetime can occur if the sensor is subjected to lead, phosphor, oxides of silicone, halogens, halogen acids or high concentrations of sulphur. A stainless steel sintered disk provides additional sensor protection from particulate, sulphur and other contaminants substantially improving the effective life of the zirconia sensor. Issue.c (March ) PROSensor (IHT) Product manual Page

Technical specification PRO Sensor (IHT) O Sensor type Zirconium (Protected with a sintered stainless steel filter) Range.% -.% Accuracy +/- % of reading IP Rated IP (sensor) IP (transmitter) Housing Stainless Steel / Aluminium Weight.kg Connection Amphenol C- Plug Dimensions x mm (max) Heater supply nom..a @.V DC Output - ma (.% -.% O ) Galvanically isolated Polarity protected Supply -V DC (Load resistance (Vsupply-.)/.(Ω)) Isolation V AC for Sec s Air humidity -% RH (non condensing) Flue gas temperature o C sustained; o C max ( hour cumulative) Ambient temperature - o C to o C EMC Emissions EN- Immunity EN- Safety EN- Flue gas temperature Flue gas temperature - ma (- o C) Power supply Input V AC @ /Hz Nominal max power VA Output.V DC (regulated) Din rail mounted Dimensions x x mm Options Digital display Pre configured to allow custom alarm thresholds: Relay output V AC @ A / V DC @A Open collector output V DC @.A (NPN) Probes Compact probe x mm (max) Issue.c (March ) PROSensor (IHT) Product manual Page

Parts List Description Power Supply Unit PRO Sensor (IHT) assembly including: mm S/S probe S/S probe locking nut Flange Plate Flue Temperature Probe assembly Gasket x M S/S Socket head cap screw x M Plain washer x M Split washer G/ Blanking plug.m Y cable assy m cable assy PRO Sensor (IHT) manual Part Number PR/ ZR Options and accessories Flange plate blanking plug ZR/ Digital display /alarm module - Spares Replacement PRO Sensor (IHT) ZR/ Replacement flue temperature probe ZR/ mm S/S probe ZR// mm S/S probe ZR// G/ Sampling port blanking plug B Issue.c (March ) PROSensor (IHT) Product manual Page