One-Piece Implant by MAKE IT SIMPLE

Similar documents
ISSN , Published by the POSEIDO Organization & Foundation

Standard Internal Hex

Straumann Dental Implant System. Fax Order Form Collection.*

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

NARROW DIAMETER implant


Dental Implant Options in Atrophic Jaws

Guidance for implant removal. Straumann Dental Implant System

Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS*

Information on the product

Implant systems warranty

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

PureForm Ceramic System. Emulating nature. The perfect disguise.

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

ARCS Pre-Implantology

Straumann Dental Implant System. Implant Selection Guide.

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Gl GinGival level implant

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

More than a fixed rehabilitation.

TRI-CAM Implant System

Straumann. Time-tested

Straumann Bone Level Tapered Implant Peer-to-peer communication

GINGIVAL LEVEL implant

High-Tech Ceramics Dental Implant System: Two Part Metal-Free Natural. User Manual. swiss made. giving nature a hand

Current Concepts in American Dentistry: Advances in Implantology and Oral Rehabilitation

Regular C/X Prosthetics. Prosthetics

Abutment fracture in a bridge supported by natural teeth and implants

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

MAY Attachment (k) Summary 21 CER

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Discover the new ANKYLOS generation: ANKYLOS C/X with the option of indexing & more...

Implants of high-performance ceramic. vk-lange :44 Uhr Seite 1. One-piece precision implant. Made in Germany

One Abutment - One Time

September 13-16, 2009

MIS System Guide User Manual

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Press Abutment Solutions

GS II Implant System. GS II Implant System. Catalog & Manual. Catalog & Manual MANUFACTURING DIVISION HEAD OFFICE

DISCOVER THE NEW ANKYLOS GENERATION: ANKYLOS C/X with the option of indexing & more...

More than an implant. A sense of trust. Straumann Dental Implant System

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

All-on-4 treatment concept with NobelSpeedy Groovy

PRoduct catalog International Headquarters Straumann USA Straumann Canada talog PRoduct

Life Table Analysis for Evaluating Curative-effect of One-stage Non-submerged Dental Implant in Taiwan

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

United States. Product Catalog 2015

Choosing the right type of abutment

The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty

Straumann Dental Implants Confident smiles

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

Manufacturer HEAD OFFICE. OSSTEM Germany GmbH. Mergenthalerallee MANUFACTURER

Supervisors: Dr. Farhan Raza Khan

páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé

Air. Air and light. Light

COMPLETE CHOICE GUIDE

Home News Customer Login Ordering Catalogs Education Contact Us

Choose What Feels Right. Bridge vs. Dental Implant

Modern Tooth Replacement Strategies & Digital Workflow

TEPZZ 69 _ZA T EP A2 (19) (11) EP A2. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

BASIC INFORMATION ON THE SURGICAL PROCEDURES. Straumann Dental Implant System

The SKY Locator family

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

procedures & products NOBELESTHETICS including Procera

Product Catalog. ERA Mini TM Dental Implant System

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

The SATURN implant by Cortex Dental Industries

Patient information on dental implants. More than just beautiful teeth. A comprehensive guide to dental implants.

Renaissance of One-Piece Implants

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Surgical technique. Sagitta EVL

Implanting Brilliancy

ATLANTIS abutments as individual as your patients

WHAT YOU NEED TO KNOW ABOUT SELECTING A DENTAL IMPLANT SYSTEM

FABRICATING CUSTOM ABUTMENTS

03) Denture System - Ball Abutment - Magnetic Abutment (Sunken Type) - Magnetic Abutment (Flat Type)

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

Dental Implant Restoration

Retrospective study on the survival rate of IBS implant

Proven Techniques and New Developments in Partially Edentulous Patients

Ridge Reconstruction for Implant Placement

PRECISION, RELIABILITY, SIMPLICITY. simeda. customized. & solutions. Digital performance

NobelActive. procedures and products

Rebilda DC. Rebilda Post System. Rebilda

Implant systems Systematically perfect

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

Transcription:

One-Piece Implant by MAKE IT SIMPLE

P. 4-5 P. 6-7 P. 8-12 P.12-13 P.14 P.15 P.16-17 MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed to be free from defects in material and workmanship. However, should a customer find fault with any MIS product after using it according to the directions, the defective product will be replaced. Warning: Only a licensed dentist should use these products. The images contained in this promotional material is for illustration purposes only and is subject to change.

Table of contents. Introduction. Advantages. One-Piece Implants (Ø3mm, Ø3.5mm). Surface. Surgical Kit. Analogs and Keys. Packaging.

4. The UNO One-Piece offers a unique monoblock design that integrates both implant and superstructure, for a quick, simple one-stage procedure. UNO implants are specifically engineered for use in narrow ridges and tight spaces. The innovative geometries and advanced surface morphology of the UNO offers high initial stability. These versatile implants can be used to restore single crowns and anterior cemented bridges. MIS Corporation. All rights reserved.

6. 4. Advantages. UNO One-Piece Implant Ø3.50mm

UNO One-Piece Abutment dimensions and height allow easy adjustment for a perfect fit with cemented crowns or bridges. Deep threads The deep thread design enables good initial stability. Sharp threads allow a smooth and predictable insertion into hard and dense bone. Dual thread The UNO dual thread design increases the BIC (Bone to Implant Contact) over the entire body of the implant. The dual thread doubles the implant insertion rate (1.50mm), facilitating a simpler and faster implant placement. Surface treatment The surface roughness and micro-morphology is a result of sandblasting and acid-etching. This proven MIS surface technology has provided millions of patients and clinicians with excellent osseointegration results and long-lasting clinical success. Two spiral channels The UNO features a domed apex, providing a high tolerance and safe procedure during insertion. Cutting apex Drill tip allows self-drilling capability for easy depth adjustments.

8. Screw type implant range One-Piece Implants Length 10mm 11.50mm 13mm 16mm Type MO1-10300 MO1-11300 MO1-13300 MO1-16300 Ø3 mm MO1-10350 MO1-11350 MO1-13350 MO1-16350 Ø3.50 mm 4 Depth Marks Drilling Diameter Options 3 3.50 10mm 11.50mm 13mm 16mm

Catalog No. Dimensions Ø3mm UNO Screw-Type Implants MO1-10300 Ø 3mm length 10mm Titanium Alloy Ti 6Al 4V ELI Sand-Blasted and Acid-Etched MO1-11300 Ø 3mm length 11.50mm MO1-13300 Ø 3mm length 13mm 6.3mm 2.7mm Ø3 MO1-16300 Ø 3mm length 16mm L Implant Ø3mm Procedure Drill Speed (RPM) Diameter 1200-1500 Ø1.90 900-1200 Ø2 Ø2 700-900 Ø2.40 Ø2.40 15-25 Ø3 Do not use the final drill for bone type 3&4 The drilling sequence is illustrated using a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.

10. Catalog No. Dimensions Ø3.50mm UNO Screw-Type Implants MO1-10350 Ø 3.50mm length 10mm Titanium Alloy Ti 6Al 4V ELI Sand-Blasted and Acid-Etched MO1-11350 Ø 3.50mm length 11.50mm MO1-13350 Ø 3.50mm length 13mm 6.3mm 2.7mm Ø3.50 MO1-16350 Ø 3.50mm length 16mm L Implant Ø3.50mm Procedure Drill Speed (RPM) Diameter 1200-1500 Ø1.90 900-1200 Ø2 Ø2 700-900 Ø2.40 500-700 Ø3 Ø3 15-25 Ø3.50 Do not use the final drill for bone type 3&4 The drilling sequence is illustrated using a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.

Innovative design makes the UNO One-Piece a simple and easy implant placement and restorative solution.

12. Surface. SEM image of the implant surface showing the micro-structure (5 μm) SEM image of the implant surface showing the micro-structure (10 μm) Identification Card and Codification of the Chemical and Morphological Characteristics of 62 Dental Implant Surfaces. Part 3: Sand-Blasted/Acid-Etched (SLA Type) and Related Surfaces (Group 2A, main subtractive process). *All MIS implants undergo the same surface treatments; sand-blasting and acid-etching. The research study was done on the SEVEN implant, however the results are valid for all MIS implant surfaces David M. Dohan Ehrenfest1,2,*, Marco Del Corso3,4, Byung-Soo Kang5, Philippe Leclercq6, Ziv Mazor7, Robert A. Horowitz8, Philippe Russe9, Hee-Kyun Oh10, De-Rong Zou11, Jamil Awad Shibli12, Hom-Lay Wang13, Jean-Pierre Bernard2 and Gilberto Sammartino3. Background and Objectives Dental implants are commonly used in dental therapeutics,but dental practitioners only have limited information about the characteristics of the implant materials they take the responsibility to place in their patients. The objective of this work is to describe the chemical and morphological characteristics of 62 implant surfaces available on the market and establish their respective Identification (ID) Card, following the Implant Surface Identification Standard (ISIS). In this third part, surfaces produced through the main subtractive process (sand-blasting/acid-etching, SLAtype and related) were investigated. Materials and Methods Eighteen different implant surfaces were characterized: Straumann SLA (ITI Straumann, Basel, Switzerland), Ankylos (Dentsply Friadent, Mannheim, Germany), Xive S (Dentsply Friadent, Mannheim, Germany), Frialit (Dentsply Friadent, Mannheim, Germany), Promote (Camlog, Basel, Switzerland), Dentium Superline (Dentium Co., Seoul, Korea), Osstem SA (Osstem implant Co., Busan, Korea), Genesio (GC Corporation, Tokyo, Japan), Aadva (GC Corporation, Tokyo, Japan), MIS Seven (MIS Implants Technologies, Bar Lev, Israel), ActivFluor (Blue Sky Bio, Grayslake, IL, USA), Tekka SA2 (Tekka, Brignais, France), Twinkon Ref (Tekka, Brignais, France), Bredent OCS bluesky (Bredent Medical, Senden, Germany), Magitech MS2010 (Magitech M2I, Levallois-Perret, France), EVL Plus (SERF, Decines, France), Alpha Bio (Alpha Bio Tec Ltd, Petach Tikva, Israel), Neoporos (Neodent, Curitiba, Brazil). Three samples of each implant were analyzed. Superficial chemical composition was analyzed using XPS/ESCA (X-Ray Photoelectron Spectroscopy/Electron Spectroscopy for Chemical Analysis) and the 100nm in-depth profile was established using Auger Electron Spectroscopy (AES). The microtopography was quantified using optical profilometry (OP). The general morphology and the nanotopography were

evaluated using a Field Emission-Scanning Electron Microscope (FE-SEM). Finally, the characterization code of each surface was established using the ISIS, and the main characteristics of each surface were summarized in a reader-friendly ID card. Results From a chemical standpoint, in the 18 different surfaces of this group, 11 were based on a commercially pure titanium (grade 2 or 4) and 7 on a titaniumaluminium alloy (grade 5 or grade 23 ELI titanium). 4 surfaces presented some chemical impregnation of the titanium core, and 5 surfaces were covered with residual alumina blasting particles. 15 surfaces presented different degrees of inorganic pollutions, and 2 presented a severe organic pollution overcoat. Only 3 surfaces presented no pollution (and also no chemical modification at all): GC Aadva, Genesio, MIS SEVEN. From a morphological standpoint, all surfaces were microrough, with different microtopographical aspects and values. All surfaces were nanosmooth, and therefore presented no significant and repetitive nanostructures. 14 surfaces were homogeneous and 4 heterogeneous. None of them was fractal. Discussion and Conclusion The ISIS systematic approach allowed to gather the main characteristics of these commercially available products in a clear and accurate ID card. The SLA-type surfaces have specific morphological characteristics (microrough, nanosmooth, with rare and in general accidental chemical modification) and are the most frequent surfaces used in the industry. However they present different designs, and pollutions are often detected (with blasting/etching residues particularly). Users should be aware of these specificities if they decide to use these products. Identification card of the MIS Seven surface, following the implant Surface identification Standard (ISIS) codification Fig. 1 Identification Card of the MIS SEVEN surface: MIS Seven (MIS Implants Technologies, Bar Lev, Israel; Figure 1) was a sandblasted/acid-etched surface on a grade 23 ELI (Extra Low Interstitials) titanium core. No pollution or chemical modification was detected. the surface was moderately microrough, nanosmooth, and homogeneous all over the implant. 1 LoB5 unit, Research Center for Biomineralization Disorders, Chonnam National University, South Korea. 2 Department of Stomatology, School of Dental Medicine, University of Geneva, Switzerland. 3 Department of Oral Surgery, Faculty of Medicine, University Federico II of Naples, Italy. 4 Private Practice, Turin, Italy. 5 Department of Physics, Seoul National University, Seoul, South Korea. 6 Private Practice, Paris, France. 7 Private Practice, Ra anana, Israel. 8 Department of Periodontology and Implant Dentistry, College of Dentistry, New York University, New York, USA. 9 Private Practice, Reims, France. 10 Department of Oral and Maxillofacial Surgery, School of Dentistry, Chonnam National University, South Korea. 11 Department of Stomatology, Shanghai Sixth People s Hospital, Shanghai Jiao Tong University, China. 12 Department of Periodontology and Oral Implantology, University of Guarulhos, Sao Paulo, Brazil. 13 Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, USA. *Corresponding author: David M. Dohan Ehrenfest.

14 Surgical Kit. The UNO One-Piece implant Surgical Kit is a compact kit, that includes drills, tools and a ratchet wrench. One-Piece Kit Contents: MT-RI030 Ratchet wrench MT-SMD10 Spade marking drill MT-TDN20 Pilot drill 2mm external irrigation MT-P2416 Pilot drill Ø2.40 height 16mm MT-TDT30 Twist drill 3mm external irrigation MT-BTT20 MT-PP001 Body try-in 2mm for tapered impl. procedure Parallel pin X2 MT-UML21 UNO One-Piece implant motor adapter, long MT-RKS15 UNO One-Piece implant long key MT-RKL21 UNO One-Piece implant long key UNO Implant Surgical Kit MK-0036

Analogs and Keys. MIS UNO One-Piece implant tools are designed to facilitate quick and reliable implant procedures. Analog MO1-RSA10 UNO One-Piece implant analog One-Piece Keys MT-UML21 UNO One-Piece implant motor adapter, long MT-RKL21 UNO One-Piece implant long key MT-RKS15 UNO One-Piece implant short key UNO One-Piece mountless tube

16. Packaging. The innovative MIS packaging system is designed for simple and easy use. All of our implant boxes feature distinctive colors, large typeface, clear data labels and a pull tab for quick opening. Boxes are a uniform shape and height, specifically designed to fit in clinic cabinets for easy accessibility and compact space-saving storage. For the dentist s use Boxes are a uniform shape and height, specifically designed to fit in clinic cabinets for easy accessibility and compact space-saving storage. Implant identification markings Quick identification markings signify: implant diameter (top), implant length (middle) and implant platform (bottom). Easy-pull tab Convenient pull tab facilitates easy, quick opening of the box during surgery.

Tubes Newlly designed molten polystyrene tubes provide easy use for maximum convenience. Pack of 10 implants The box is designed to contain exactly 10 pieces of each item with the same lot number. It can be used as a display stand or stored in a drawer, where items can be easily and readily identified.

All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher.

MC-UNO08 Rev.1 Rev.5 MIS Quality System complies with international quality MIS Implants Technologies Ltd www.mis-implants.com MIS Implants Technologies Ltd. www.mis-implants.com standards: ISO 13485:2003 - Quality Management System for Medical Devices, ISO 9001: 2008 Quality Management System and CE Directive for Medical Devices ISO 9001:2000 93/42/EEC. MIS products are cleared for marketing in the ISO 13485:2003 USA and CE approved. 0483 Authorized European Representative: MIS Germany, Paulinenstraße 12a, 32427 Minden, GERMANY MIS Corporation. All All Rights Rights Reserved. Reserved.