Manufacturer HEAD OFFICE. OSSTEM Germany GmbH. Mergenthalerallee MANUFACTURER
|
|
- Lauren Blankenship
- 8 years ago
- Views:
Transcription
1 Edition 06 / Germany GmbH Manufacturer HEA OFFICE MANUFACTURER Mergenthalerallee 25 #507-8, Center, #507-8, Geoje3-dong, Geoje3-dong, Yeonje-gu 8th F. WorldMeridian Venture CenterⅡ, 426-5, Gasan-dong, Eschborn Geumcheon-gu, Seoul, Korea Busan, Busan, Korea Korea. Zip: Zip_ Tel: tel_ (0) , 96 / fax_ Tel: +82 tel_ homepage_ Fax: +82 fax_
2 Implant Implant for Narrow Ridge Implant for This implant is is suitable for for a narrow a narrow ridge, ridge, such such as the as lower the lower This implant is for immediate provisional prosthetics for Fixture and abutment are are combined to withstand to withstand chewing chewing pressure pressure and Micro and thread Micro design thread was adopted design was to increase adopted chewing to increase power. chewing RBM surface power. was adopted for quick osseointegration. Neck can bent for correct insertion. RBM The shape surface and was the size adopted of abutment for quick part were osseointegration. optimized to enable Titanium provisional cap and ab analog enable easy The prosthetics shape without and the cutting. size of abutment part were optimized to enable prosthetics cap increases without the convenience cutting. of manufacturing cap increases the convenience of manufacturing immediate cap prosthetics. and lab analog enable a sophisticated restorative cap and lab analog enable a sophisticated restorative cap helps manufacturing prosthetics chair side. Ø2,5/ 3mm Abutment design for manufacturing dental Narrow neck design for an Micro thread design for for an an increase of of initial initial and and long-term stability. stability. Ø1,8/ 2,5mm Neck design to corrects the direction Connection of enture river which can be used when the neck when is the fractured neck is fractured Threaded body design for an increase of of Threaded body design to to increases initial stability Inplant Implant IMPANT
3 Implant Implant for Narrow entureridge Mechanical Implant rilling for Power according to the Neck esign enture-type This implant is implant suitable is for for a edentulous narrow ridge, patients such as with the narrow lower ridge anterior for region. those cases in which a standard implant is not possible. Fixture and abutment are combined to withstand chewing pressure enture RBM surface micro was thread adopted in the for upper quick distributes osseointegration. chewing pressure throughout The shape and bone the structure size of abutment making part it suitable were optimized for an immediate to enable prosthetics without placement. cutting. cap increases the convenience of manufacturing enture immediate retainer prosthetics. and lab analog allows easy and convenient denture manufacturing. cap and lab analog enable a sophisticated restorative Purpose This implant is for immediate provisional prosthetics for Combined partially and fixture completely and abutment-shaped edentulous patients. design enables implantation in a narrow ridge such as lower Research on the effectiveness of narrow neck and safety of soft tissue is on going and new designs including platform switching Neck can have bent been for correct invented. insertion. The effectiveness of narrow neck seems unclear. Therefore, fatigue stress and cycle-durability tests were conducted for each neck design. Titanium provisional cap and ab analog enable easy Materials manufacturing & Method of provisional prosthetics. Three test implants were made according to diameter and materials in neck areas. 5 test implants were manufactured per test. ISO14801 setting was arranged under the condition of 0N 30 5Hz 200,000 cycles. Additionally fatigue tests were conducted. Neck iameter Ø2,5/ 3mm Ball shape is suitable for o-ring attachment Abutment design for manufacturing dental Available in 2 or 4mm to account for gingival height O-Ring Retainer Set Contrast Competitor A cap helps manufacturing prosthetics chair side. Neck iameter Materials Cp Gr-5 Cp Gr-5 Cp Gr-4 Neck design to corrects the direction Connection of enture river which can be used Narrow neck design for an Micro threaded design is devised to improve initial bonding Micro thread stability. design for an increase of Test Results All the test results show that implant is superior to others in terms of endurance and resistance against fatigue and torsion resistance. {, Contrast, Competitor A} (N) (N) Threaded body design increases initial stability Threaded body design for an increase of Competitor A Threaded body design to increases initial stability Contrast Results of Fatigue Test () (Contrast) (Competitor A) S-N Curve 04 Inplant Implant IMPANT 05
4 Implant Analysis Implant of Initial for Narrow Stability Ridge According to Body esign Implant for Components Purpose This implant is suitable for a narrow ridge, such as the lower To analyze the internal stress diversion of mini implant (the diameter anterior of region. fixture is less than 3mm) through FEA. Fixture and abutment are combined to withstand chewing pressure Materials & Method Five categories of implants were developed in different settings RBM of pitch, surface bone was depth adopted and for micro quick osseointegration. thread. An analysis on internal stress diversion was done under the loading condition of The 0N shape in and 30 the size of abutment part were optimized to enable *FEA: Finite-Element Analysis *ASTM: American Society of Testing Materials *ANSYS: Engineering software for FEA *ANOVA: Analysis of Variance Macro Thread Micro Thread [ Indications Pitch ] epth Pitch epth Sample(A) None Sample(B) None Unit : mm cap increases the convenience of manufacturing cap and lab analog enable a sophisticated restorative Sample(A) Sample(B) Abutment design for manufacturing dental Test Results Pull-out and Push-out test show that implant has better results compared with Sample A and Sample B. FEA results show Narrow neck design for an that implant has the highest internal stress diversion. Micro thread design for an increase of Results of Pull-Out Test Results of FEA F This implant is for immediate provisional prosthetics for Implant (Narrow ridge) Neck can bent for correct insertion. Titanium provisional cap and ab analog enable 7 easy P253R P251R P253R P253R P3R P304R P301R P30114R P303R P304R P303R P304R A mini implant that is adequate for narrow space such as the mandibular anterior jaw One-body implant with micro thread design enhances the destribution of masticatory force RBM surface treatment enables fast osseointegration Optimized cap helps shape manufacturing and size of abutment prosthetics enables chair cutting-free side. prosthetic work Optimal design of body, thread, and drills to enhance initial bonding and bone penetration Packing unit : Implant (Narrow ridge) Neck design to corrects the direction Connection of enture river which can be used P254R P25114R P254R P254R (N) Sample(A) Sample(B) Type A : Implant Narrow Ridge Type Threaded body design for an increase of Unit:Mpa Sample A Sample B Maximum Torque (Narrow ridge) PIC Threaded Use body for design precise to impression increases work initial stability In case of non-modification of abutments : After taking an impression using an impression cap, make the prosthesis after creating a model using an analog In case of modification of abutment height only: After taking an impression using an impression cap, create a model using an analog and make the prosthesis by modifying the model shape according to the modification of abutment Packing unit : cap 06 Inplant Implant IMPANT 07
5 Implant Implant for Narrow Ridge Implant for (Narrow ridge) This implant is suitable for a narrow ridge, such as the lower PTC Use for making Fixture temporary and abutment prosthesis are combined to withstand chewing pressure One-touch locking design Packing unit : (Narrow ridge) RBM surface was adopted for quick osseointegration. The shape and the size of abutment part were optimized to enable cap increases the convenience of manufacturing cap and lab analog enable a sophisticated restorative This implant is for immediate provisional prosthetics for Implant () T184 T184 Neck can bent for correct insertion. T184 Titanium provisional cap and ab analog enable easy ab [ Indications Analog ] (Narrow ridge) PA Make an Implant (narrow ridge) abutment of the oral cavity onto a working model Packing unit : T254 T254 T254 Abutment design for manufacturing dental Narrow neck design for an Micro thread design for an increase of Implant cap helps to be used manufacturing for the immediate prosthetics mounting chair of side. temporary prosthesis for completely or partially edentulous patients Neck designed for path compensation and intensity support Simple system to make temporary prosthesis using titanium provisional caps and lab analogs Neck design to corrects cap facilitating the direction prosthetic work chair side Rectangular structure at the bottom of the neck facilitates easy removal of Connection provisional of enture implant river which can be used when the Optimized neck is fractured design of body, thread, and drilling to enhance initial bonding and bone penetration Packing unit : Implant () () TPC Use for making temporary prosthesis (Titanium) Packing unit : Threaded body design for an increase of () Threaded body design to increases initial stability TA Make an Implant (provisional) abutment of the oral cavity on a working model Packing unit : 08 Inplant Implant IMPANT 09
6 Implant Implant for Narrow Ridge anterior region. 252R 25112R R KIT Neck can bent for correct insertion. The shape and the 252R size of abutment part were optimized to enable 254R 25112R 25114R prosthetics without252r cutting. 254R Titanium provisional cap and ab analog enable easy 252R 254R 3.0 of cap increases the convenience manufacturing immediate prosthetics R R cap and lab analog enable a sophisticated restorative R R 302R 3R 304R 304R 302R 30112R 304R 30114R bone; more advantageous for immediate prosthetic mounting edentulous patients or if regular implant is inappropriate Easy and convenient denture work through the use of retainers Micro thread on top helps distribute masticatory pressure to the and lab analogs bone; more advantageous for immediate prosthetic mounting Ball-type structure for the connection of the O-ring attachment Easy and convenient denture work through the use of retainers Use by selecting 2/4mm depending on the gingival height Abutment design for manufacturing dental and lab analogs Packing unit : anterior Implant (enture) ceramics in lower teeth enabling Ball-type structure for the connection of the O-ring attachment immediate placement. Use byprosthetics selecting 2/4mm depending on the gingival height Packing unit : Implant (enture) alveolar rill Torque river Machine river Spare rill Torque river Machine river Spare O-Ring Retainer Set O-Ring Retainer Set Name Micro thread design for an increase of Retainer cap set initial ando-ring long-term stability. Nameset O-ring O-ring Retainer cap set for making stud-type overdenture O-ring set Packing unit : Retainer + O-ring Use (enture) (enture) rivers for the Narrow Ridge and types (4types) - Machine ong(narrow Ridge) rivers forriver the Narrow Ridge and types -(4types) Torque river ong(narrow Ridge) -- Machine (enture) Machine river river Short ong(narrow Ridge) Torque river river ong(narrow Short (enture) -- Torque Ridge) - Machine river Short (enture) 1 set of 3river Short (enture) - Torque - Parallel Pin - river 1 set of Separator 3 epth Gauge -- Parallel Pin - river Separator Components (optional) - epth Gauge 1 set of 3 types of drivers for denture 1 set of 2 other types - Machine river Short(Narrow - Torque Handle KIT Components (optional) Ridge) -1 Torque -1 Torque set of 3river typesshort(narrow of drivers forridge) denture set of 2Wrench other types cap helps manufacturing prosthetics chair side. Handle -- Torque river ong (enture) Machine river Short(Narrow Ridge) - Torque - Torque river Short(Narrow Ridge) - Torque river ong (enture) - Torque Wrench Narrow Ridge Type : No hole on the head Narrow Ridge Type enture Type enture Type : A hole on the head RCS01 OAON01S RCS01 rill for Implant OAON01S Name 1.5mm ance rill rill for Implant Use for making stud-type overdenture Packing unit : Retainer + O-ring Threaded body design for an increase of self tapping and initial stability Components (basic) -5-drill 1.5mm set ance rill - 1.8mm Twist rill ong mm 1.5mm Twist ancerill rillshort 2.3mm Twist Twist rill rill ong ong mm mm 1.8mm Twist Twist rill rill Short Short Connection enture river which can be used enture Type Narrow of Ridge Type iscemment Torque rivers enture Type : A hole on the head Narrow neck design for an KIT Neck design to corrects the direction iscemment Torque rivers Narrow Ridge Type : No hole on the head (basic) 5-drill set KIT Micro thread on top helps distribute masticatory pressure to the alveolar enture-type implant can be used in case of narrow ridge width for OK implant can be used 302R 304R in case of narrow ridge width for patients or if regular 302R edentulous implant is inappropriate304r Implant KIT - 2.3mm Twist rill ong - 2.3mm Twist rill Short enture-type OK KIT Components Implant KIT RBM surface was adopted for quick osseointegration. 252R 254R 252R 254R 254R KIT ( KIT) 2.0 Fixture and abutment are combined to withstand chewing pressure Implant (enture) This implant is for immediate provisional prosthetics for This implant is suitable for a narrow ridge, such as the lower Implant (enture) Implant for A Make an Implant (denture) abutment of the oral cavity on a working model A Packing unit : an Implant (denture) abutment of the oral cavity on a working model Packing unit : 8 ance rill Twist rill ance rill Twist rill OS 42 OS OS OS18S Name rill ong 1.8mm Twist 1.8 Threaded body design increases stability 1.5mm ance mm Twisttorill Short initial 1.8 Make 8 1.8mm 2.3mm Twist rill ong OS18 OS23 1.8mm 2.3mm Twist rill Short OS18S OS23S 2.3mm mm Twist rill ong OS23 OS25 2.3mm mm Twist rill Short OS23S OS25S 42 OS25 abmarking Analog specification as implant length for easy identification ; laser mm Twist rill Short 32 OS25S on 8////mm.For lance drilling, drilling only the cortical bone is mm Twist rill ong Same recommended; enables drillinglength up to the laser identification marking line depending on Same specification as implant for easy ; laser marking the surgeon's work environment on 8////mm For lance drilling, drilling only the cortical bone is recommended; enables drilling up to the laser marking line depending on the surgeon's work environment Inplant Implant IMPANT IMPANT 11 Inplant IMPANT 11
7 Implant Implant for Narrow Ridge Warnings Implant & for Procedures river for Narrow Ridge & Type river for enture type Torque river Machine river This implant is suitable for a narrow ridge, such as the lower Name Fixture and abutment are combined to withstand chewing pressure Torque river (Short) PTS Torque river (ong) PT Machine RBM river surface (Short) was adopted 3.4for quick osseointegration P Machine The river shape (ong) and the size 3.4 of abutment part 29.4 were optimized PM to enable Special-purpose prosthetics driver without for Implant cutting. (Narrow Ridge and ) The triangle mark is used cap by increases aligning the driver convenience with the implant of manufacturing cross section cap and lab analog enable a sophisticated restorative Name Torque river (Short) TS Torque river (ong) T Machine river Special-purpose driver for Implant (denture) The triangle mark is used by aligning the driver with the implant cross section This implant is for immediate provisional prosthetics for How to separate driver when pinching occurs during insertion Neck can bent for correct insertion. Titanium provisional cap and ab analog enable easy river Separator Insert river separator into the hole and lift up the driver Implant by ever Principle How to recover Type Path Correct the Path by using epth Gauge. Fracture of Implant Neck can be occurred in excessive bending. Torque river Machine river Abutment design for manufacturing dental cap helps manufacturing prosthetics chair side. Gauge for Implant epth Gauge immediate prosthetics Name placement. epth Gauge G Parallel Pin PP epth gauge Narrow eft neck : For depth design checking for an upon drilling increase Right of : Use gingival for stability implant bending The parallel pin is used for path checking upon drilling. Micro thread design for an increase of Neck design to corrects the direction Connection of enture river which can be used How to remove implant when fracture occurs in Type Parallel Pin Torque Handle TH Use for manual torque after connecting to the connected part of a torque Threaded driver body design for an increase of Threaded body design to increases initial stability enture river Type implant with fractured neck river Separator S In case a driver is stuck during implantation, the river Separator helps remove the driver based on the lever principle (inserting river Separator into the driver groove) When the neck fractures. Connect denture driver to provisional implant. Rotate the driver counter-clockwise to remove 12 Inplant Implant IMPANT
8 Implant Warnings Implant & Procedures for Narrow Ridge Product Implant Information 1. Push the dotted line at the top of the This implant is suitable for a narrow ridge, such as the lower This implant is for immediate provisional prosthetics for package with hands. The package includes a implant, manuals, and chart stickers. Fixture and abutment are combined to withstand chewing pressure 42mm Neck can bent for correct insertion. The laser markings indicate the length of implant RBM surface was adopted for quick osseointegration. The shape and the size of abutment part were optimized to enable 35mm 32mm Titanium provisional cap and ab analog enable easy cap increases the convenience of manufacturing mm 2. The implant is sterilized before it is placed into the blister package. iameter, length, product code cap and lab analog enable a sophisticated restorative mm number and ot number are written on the back of the package.. Abutment design for manufacturing dental iameter of implant and final drill cap helps manufacturing prosthetics chair side. 3. Remove the cap and the abutment part is exposed. Align the arrow mark on the driver with the cross section of the implant when you connect it. If a secure connection is not made, try again. Narrow neck design for an Micro thread design for an increase of Final rill Implant iameter Interference Recommandation rilling the length of cortical bone Neck design to corrects the direction 1.5~ ~0.5 rilling the length of the implant 1.8~ ~0.6 rilling the length of the implant Connection of enture river which can be used ** The harder structure is, the larger the diameter of final when drill the should neck be. is fractured rill depth Interference Implant diameter 4. Take the implant out of the ampule and move it cautiously as the picture shows. Avoid contact with any objects and dropping the implant. Threaded body design for an increase of river selection guide according to location ocation How to use Recommendation Threaded body design to increases initial stability In case of hight crown Engine ong Type river (Anterior teeth) Hand ong Type river In case of narrow osslusal space (Posterior teeth) Engine Hand * Recommendations : 25 rpm, 30Ncm ( 1.8 : 25Ncm) Short Type river Short Type river 22mm 20mm 17mm mm Anterior teeth Posterior teeth 14 Inplant Implant IMPANT
9 Implant Recommended Implant for Surgical Narrow Ridge Procedure Implant Prosthetic for Procedure for Narrow Ridge Implant ( / 3.0) _ Recommended insertion torque This : 30Ncm implant is suitable for a narrow ridge, such as the lower Fixture and abutment are combined to withstand chewing pressure RBM surface was adopted for quick osseointegration. The shape and the size of abutment part were optimized to enable cap increases the convenience of manufacturing cap and lab analog enable a sophisticated restorative Step This 1 implant : is for immediate Restoration provisional prosthetics for 1. partially Check vertical and completely height, and edentulous path after patients. implant insertion. (Remove upper part of implant, using irrigation, Neck if adjustment can bent is for necessary.) correct insertion. 2. Titanium Fabricate provisional and place cap provisional and ab analog prosthetics enable by easy using manufacturing temporary cap. of provisional prosthetics. Make adjustment considering length of upper marking line, and accurate prosthetics manufacturing using lab analogue is possible. Shaping individual margin is possible in the 3mm margin area of the implant. Step 2 : & Working Cast [ When abutment is not made ] 1. Place an impression cap on the implant. cap helps manufacturing prosthetics chair side. ance rill 800rpm Check Path Abutment design for manufacturing dental 1.8 rilling / ceramics in Check lower epth anterior teeth enabling Engine Mode : 30Ncm 2.3 rilling / Manual Mode : ess than 70Ncm 2.5 rilling ( Type : ess than 40Ncm) 1200rpm Implant ( 1.8) _ Recommended insertion torque : 25Ncm Narrow neck design for an Micro thread design for an increase of Separate river 2. Take an impression 3. Send impression and lab analog to lab for manufacturing of prosthesis When the abutment is modified. Take a direct impression. Send to lab for manufacturing of prosthesis Neck design to corrects the direction Connection of enture river which can be used When only abutment height was adjusted. Place an impression cap on implant. Threaded body design for an increase of Take an impression, send impression and lab Threaded body design to increases initial stability analog to lab for manufacturing of prosthesis Step 3 : Setting ance rill 800rpm Only cortical bone with irrigation Engine Mode : 25Ncm Manual Mode : ess than 40Ncm Separate river Place prosthesis in mouth check occlusion Caution :In Type, insert the implant by using Torque Handle(TH), otherwise, fracture of neck may be occurred when more than 40Ncm of torque value is reached. 16 Inplant Implant IMPANT 17
10 Implant Implant ImplantProsthetic for NarrowProcedure Ridge for Step 1 This implant is suitable for a narrow ridge, such as the lower Manufacture a temporary prosthesis on the model. Implant Implant for Prosthetic Procedure for denture implant for immediate provisional prosthetics for A.This For newisdenture Fixture and abutment are combined to withstand chewing pressure Step 1 Step 2 NeckO-ring can bent insertion. Insert in for thecorrect Retainer, place the retainer on the Insert Implant between the implants. RBM surface was adopted for quick osseointegration. The shape and the size of abutment part were optimized to enable Ball Head exposed in the mouth and take an impression. Titanium provisional cap and ab analog enable easy Step 3 manufacturing of provisional prosthetics. Step 2 Check and control the Path of Implant. cap increases the convenience of manufacturing Connect to the retainer in the impression Step 4 cap and lab analog enable a sophisticated restorative Step 3 Confirm the space where can be inserted After manufacturing the working model, remove the on the temporary prosthesis. Retainer from the impression according to the general rules. Step 5 Step 4 Connect in the mouth. Using the completed working model, manufacture enture according to the general rules.. Step 6 cap helps manufacturing prosthetics chair side. After covering with a Rubber am, connect Abutment design for manufacturing dental Step 5 and temporary prosthesis using Resin. Check the insertion points of the denture Neck design to corrects the direction Step 7 Step 6 Remove the surplus resin and adjust occlusion after Resin Connection Push the O-ring through the rubber dam. Insert the o- of enture river which can be used hardens. ring into the retainer. Attach the retainer to the o-ring Narrow neck design for an Set the temporary prosthesis using Cenment. Micro thread design for an increase of abutment. Step 7 Inject Resin into the Hole formed on enture and remove the surplus after Resin has hardened. Step 8 Threaded body design for an increase of Threaded body design to increases initial stability Check the bearing and occlusion status. 18 Inplant Implant IMPANT IMPANT 19
11 Implant Implant Implant ImplantProsthetic for NarrowProcedure Ridge for denture B. Using existing denture Implant for Clinical Application using Implant This implant is suitable for a narrow ridge, such as the lower This implant is for immediate provisional prosthetics for Fixture and abutment are combined to withstand chewing pressure Step 1 Considering Path, insert Implant according to the set surgery procedure. RBM surface was adopted for quick osseointegration. Neck can bent for correct insertion. The shape and the size of abutment part were optimized to enable Titanium provisional cap and ab analog enable easy Step 2 After checking the location of insertion, form the Hole on cap increases the convenience of manufacturing the existing denture. cap and lab analog enable a sophisticated restorative Step 3 Connect Rubber am and then connect Ball Head by inserting O-Ring with weak bearing into the Retainer. Step 4 Inject Resin after setting the existing denture formed Hole. Remove the surplus part after Resin has hardened. Step 5 Check the bearing and occlusion status. cap helps manufacturing prosthetics chair side. Abutment design for manufacturing dental Neck design to corrects the direction Narrow Ridge PatientCondition: narrow Final Narrow neck design for an Micro thread design for an increase of rill : 1.8 Implant ridge Connection of enture river which can be used : x.0mm Bone Type : 3 Torque Value : 17Ncm Threaded body design to increases initial stability Threaded body design for an increase of 20 Inplant Implant IMPANT IMPANT 21
12 Implant Implant Implant for Narrow Ridge Clinical Application using Implant Implant for Clinical Application using Implant This implant is suitable for a narrow ridge, such as the lower This implant is for immediate provisional prosthetics for Fixture and abutment are combined to withstand chewing pressure Neck can bent for correct insertion. RBM surface was adopted for quick osseointegration. The shape and the size of abutment part were optimized to enable Titanium provisional cap and ab analog enable easy cap increases the convenience of manufacturing cap and lab analog enable a sophisticated restorative cap helps manufacturing prosthetics chair side. Abutment design for manufacturing dental Narrow Ridge Narrow Ridge PatientCondition: PatientCondition: No more increase in bone volume Final rill : 1.8 Implant : x.0mm x.0mm tooth extraction 2 weeks before surgery Narrow neck design for an Micro thread design for an increase of Final Neck design to corrects the direction Connection of enture river which can be used rill : 1.8 Implant : x.0mm Bone Type : 3 Bone Type : 3 / Ncm Torque Value : 17 Threaded body design to increases initial stability Threaded body design for an increase of 22 Inplant Implant IMPANT IMPANT 23
13 Implant Implant Implant for Narrow Ridge Clinical Application using Implant Implant forsterilization Washing and This implant is suitable for a narrow ridge, such as the lower Thisto implant is for&immediate provisional prosthetics for How maintain Store surgical instruments partially and completelysurgical edentulous patients. should be soaked in sterilizing solution to prevent hardening of the blood. Wash 1.Right after procedure, instruments Fixture and abutment are combined to withstand chewing pressure with running or distilled water to completely remove blood and other remaining objects. Neck can bent for correct insertion. RBM surface was adopted for quick osseointegration. 2. ry with paper towel or heater. Put the instruments in sterilizing kit, and sterilize them for minutes at 5 in Autoclave. The shape and the size of abutment part were optimized to enable Titanium cap and ab dry analog Keep theprovisional sterilized instruments andenable store. easy cap increases the convenience of manufacturing cap and lab analog enable a sophisticated restorative cap helps manufacturing prosthetics chair side. Soak surgical instruments in sterilization solution and wash in distilled or running water, Abutment design for manufacturing dental Neck design to corrects the direction Narrow Ridge Connection of enture river which can be used PatientCondition: No more increase in bone volume Final rill : 1.8 / 2.3 Implant : x.0mm 3.0 x.0mm Remove water and disinfect for minutes at 5 in Autoclave. Narrow neck design for an Micro thread design for an increase of Bone Type : 3 Threaded body design to increases initial stability Threaded body design for an increase of 24 Inplant Implant IMPANT IMPANT 25
14 Cautions Cautions Implant Surgical Implant Procedure for Narrow Ridge How Implant to Maintain for Surgical KIT This implant is suitable for a narrow ridge, such as the lower The operator must check the following items before starting the surgery. Fixture and abutment are combined to withstand chewing pressure Patient's condition RBM surface was adopted for quick osseointegration. Sufficient bone volume and quality prior to treatment etailed health status The shape and the size of abutment part were optimized to enable Smoking and/or drinking habits prosthetics Masticatory without cutting. pattern and habit Status of oral hygiene cap Psychological increases the convenience state of manufacturing Patient's understanding of implant surgery cap and lab analog enable a sophisticated restorative Treatment Plan iscuss treatment options with your patient. Include the pros and cons of each treatment as well as the procedure involved. This implant is for immediate provisional prosthetics for 1 uring surgery, be sure to keep used tools in saline or distilled water. Neck can bent for correct insertion. Titanium provisional cap and ab analog enable easy 2 Rinse tools with distilled or running water to remove all blood and debris. 3 Alcohol wash all tools used in surgery Caution: o NOT use hydrogen peroxide *Exposure to hydrogen peroxide may cause discoloration to laser markings and/or TiN coating 4 Remove all moisture with a dry cloth or warming fan Abutment design for manufacturing dental Medical iagnosis Check the patient s health history before implant surgery. iscuss the treatment plan and health history with the patient s primary care physician before performing surgery. Narrow neck design for an Micro thread design for an increase of Improper upper/lower posterior height Improper lower anterior width Extremely poor bone quality Congenital or acquired heart conditions Ischemic heart patient (angina, myocardial infarction) High blood pressure Patient s distrust of implant treatment Pay Particular Attention to the Following during an Implant Procedure Threaded body design for an increase of Precautions 5 Replace cap helps dried manufacturing tools into the prosthetics Kit case chair side. (Refer to the color-coding for easy placement.) Neck design to corrects the direction 6 Autoclave Kit for minutes at 2, then store at room Connection temperature. of enture river which can be used Immediately after surgery separate, wash and store all tools. Re-sterilize Kits prior to surgery (2 for minutes) Hanaro All drills Kits and have drivers a 1 year are recommended product Threaded warranty body for (after up design to opening); 50 to uses. increases all drills initial and drivers stability are recommended for up to 50 uses. 26 Inplant Implant IMPANT 27
MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT
FIXTURE COMPONENTS 004 006 MS SA Implant - Narrow Ridge MS SA Implant - Denture 008 010 MS Implant - Provisional MS KIT MS SA Implant - Narrow Ridge MS SA Implant - Narrow Ridge Components 3 7 Impression
More informationContents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment
Contents TS Implant System Cement retained restoration Screw retained restoration 06 Cement-retained bridges with the Solid abutment system (non- 72 Screw retained crown with the ComOcta Gold abutment
More informationNARROW DIAMETER implant
ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball
More informationGS II Implant System. GS II Implant System. Catalog & Manual. Catalog & Manual MANUFACTURING DIVISION HEAD OFFICE
Implant System Catalog & Manual Implant System Catalog & Manual HEAD OFFICE 8th FL WorldMeridian Venture Center, 426-5, Gasan-dong, Geumcheon-gu, Seoul, Korea tel_ 02 2016 7000, fax_ 02 2016 7001 homepage_
More informationPROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM
PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM HG Implant System Contents Cement retained restoration Rigid abutment When abutment reduction is unnecessary When abutment
More informationRestoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16
More informationSCD Case Study. Treatment Considerations for Implant Rehabilitation
SCD Case Study Treatment Considerations for Implant Rehabilitation Multiple surgical and restorative factors play a role in the treatment planning of implant restorations for the edentulous patient (Ali
More informationDental Implant Options in Atrophic Jaws
Dental Implant Options in Atrophic Jaws Orthopedic Application Jay B. Reznick, D.M.D., M.D. Diplomate, American Board of Oral and Maxillofacial Surgery Tarzana, CA Endopore Dental Implant System Screw-Type
More informationWhat Dental Implants Can Do For You!
What Dental Implants Can Do For You! Putting Smiles into Motion About Implants 01. What if a Tooth is Lost and the Area is Left Untreated? 02. Do You Want to Restore Confidence in Your Appearance? 03.
More informationOne Abutment - One Time
One Abutment - One Time A new treatment concept simple, innovative, easy to implement. Something so simple that does so much. What makes One Abutment - One Time a favorite among clinicians and patients
More informationGIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.
Now Distributed By GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN. OPENING MINDS AND EXPANDING PRACTICE REVENUE OPPORTUNITIES Since the McGill Consensus in 2002, the dental industry has recognized
More informationUnderstanding Dental Implants
Understanding Dental Implants Comfort and Confidence Again A new smile It s no fun when you re missing teeth. You may not feel comfortable eating or speaking. You might even avoid smiling in public. Fortunately,
More informationContact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare.
Use of CP Titanium and Titanium alloys for Dental Implants Steve Hurson, Nobel Biocare U.S.A. Yorba Linda CA Abstract Professor Per Ingvar Branemark of Sweden published his results on 15 years of research
More informationStandard Internal Hex
Standard Internal Hex Touareg TM -OS Touareg TM -S Swell TM Touareg -S Touareg -OS Swell About ADIN Adin Dental Implant Systems Ltd., designs, manufactures and markets state of the art, technologically
More informationRidge Reconstruction for Implant Placement
Volume 1, No. 5 July/August 2009 The Journal of Implant & Advanced Clinical Dentistry Ridge Reconstruction for Implant Placement 2 Hours of CE Credit Oral Implications of Cancer Chemotherapy Immediate
More informationProsthodontist s Perspective
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution - Non-Commercial - Share Alike 3.0 License. Copyright 2008, Dr. Jeff Shotwell. The following
More informationTRI-CAM Implant System
TRI-CAM Implant System infinite opportunities In Implantology For almost 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop and manufacture the highest quality,
More informationIMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?
IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS? Dental implants are a very successful and accepted treatment option to replace lost or missing teeth. A dental implant is essentially an artificial tooth
More informationIMPLANT DENTISTRY EXAM BANK
IMPLANT DENTISTRY EXAM BANK 1. Define osseointegration. (4 points, 1/4 2. What are the critical components of an acceptable clinical trial? (10 points) 3. Compare the masticatory performance of individuals
More information2016 Buy Up Dental Care Plan Procedure List
* This is in addition to the embedded Preventive Plan (see procedure list at deltadentalco.com/kp_preventive. BASIC SERVICES Minor Restorative Services D2140 Amalgam 1 surface, primary or permanent D2150
More informationImplant Parts. A Radford Heath Guide http://www.radfordheath.com 1
Implant Parts A Radford Heath Guide http://www.radfordheath.com 1 Disclaimer The information given in this document has been provided in good faith for basic information purposes only and the information
More informationprocedures & products NOBELESTHETICS including Procera
procedures & products NOBELESTHETICS including Procera First from Nobel Biocare. NOBELPERFECT, (NP, RP, WP), NOBELDIRECT (NP, RP, WP), Brånemark System, NOBELREPLACE and NOBELSPEEDY Implants. A complete
More informationRESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS
RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. CONTENTS Product
More informationORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology
ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning Orthodontics and Implantology 2 All rights are reserved. Any reproduction of the present publication is prohibited in whole or in part and by
More informationDENTAL IMPLANT THERAPY
DENTAL IMPLANT THERAPY PATIENT WELCOME PACK Dr. Syed Abdullah BDS, MSc (Dental Implants) What are dental implants? In the early 1950s, a Swedish Scientist, Per-Ingvar Branemark observed that titanium metal
More informationTHE LOCATOR OVERDENTURE IMPLANT SYSTEM.
THE LOCATOR OVERDENTURE IMPLANT SYSTEM. FOUR DECADES OF ATTACHMENT KNOWLEDGE INCORPORATED INTO NARROW DIAMETER OVERDENTURE IMPLANTS. The LOCATOR Overdenture Implant System (LODI) is comprised of 2.4mm
More informationGl GinGival level implant
GL Gingival Level implant TABLE OF CONTENTS GL - Gingival Level implant Implant characteristics page 04 Dental implant page 05 Prosthetic components page 06 Ball attachment system page 08 Temporary peek
More informationNobelActive. procedures and products
NobelActive procedures and products precautions and warnings Manufacturer: Nobel Biocare AB, Box 5190, SE-402 26 Göteborg, Sweden. Phone: +46 31 81 88 00. Fax: +46 31 16 31 52 www.nobelbiocare.com Important!
More informationSmile Confidently With DIEM 2. Immediate Full Arch Rehabilitation
Smile Confidently With DIEM 2 Immediate Full Arch Rehabilitation Immediate Full Arch Rehabilitation * Edentulism and failing dentition continue to be major health challenges affecting millions of people
More informationAll-on-4 treatment concept with NobelSpeedy Groovy
All-on-4 treatment concept with NobelSpeedy Groovy Product overview Immediate Function for high patient satisfaction Immediately loaded fixed provisional prosthesis on the day of surgery. Immediate improvement
More informationDESS. Screws. Tijuana Ventas: (664) 685 6294/95 hirambogarin@dabocorp.com. For all major implant systems!! www.dabocorp.com
Screws Screws for definitive use. Made from medical grade 5 ELI Titanium Integrity and soundness guaranteed by stress tests of up to 150% of their nominal torques. Their designs ensure a perfect fit with
More informationADA Insurance Codes for Laboratory Procedures:
ADA Insurance Codes for Laboratory Procedures: Inlay/Onlay Restorations D2510 Inlay - metallic - one surface D2520 Inlay - metallic - two surfaces D2530 Inlay - metallic - three or more surfaces D2542
More informationImplant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology
Implant Systems MAX LOGIC MONO Today s name in tomorrow s implant technology Implant Systems Etgar Medical Implant Systems brings to the market an entire spectrum of dental implant products based on its
More informationClinical and Laboratory Procedures for Fixed Margin Implant Abutments
Clinical and Laboratory Procedures for Fixed Margin Implant Abutments Dr. Carl Drago DDS, MS, American Board of Prosthodontics Director, Dental Research BIOMET 3i, Adjunct Faculty Department of Prosthodontics,
More informationTaking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI
Taking the Mystique out of Implant Dentistry Dr. Michael Weinberg B.Sc., DDS, FICOI What is Restorative Implant Dentistry? Restorative implant dentistry involves taking a few simple mechanical principles
More informationWhat is a dental implant?
What is a dental implant? Today, the preferred method of tooth replacement is a dental implant. They replace missing tooth roots and form a stable foundation for replacement teeth that look, feel and function
More informationBEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / 2016. Partners in Progress
BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / 2016 Partners in Progress PREFACE Affordable, innovative implantology products "Made in Germany" Dear customers and partners, Walter Esinger Managing Director
More informationSURGICAL MANUAL. Step By Step Techniques
SURGICAL MANUAL Step By Step Techniques TABLE OF CONTENTS PRE-SURGICAL 1 8 MEASUREMENT OF BONE.......................... 2 BONE CLASSIFICATION........................... 3 IMPLANT SIZE SELECTION.........................
More informationALL-CERAMIC DENTAL IMPLANT SOLUTIONS
ALL-CERAMIC DENTAL IMPLANT SOLUTIONS Scientific Evidence Bone-to-implant contact of 78% at 3 months. One piece implant = no prosthetic connections References 1. One-year follow-up of first consecutive
More informationRegular C/X Prosthetics. Prosthetics
Regular C/X Prosthetics /X C/ Prosthetics ANKYLOS C/X Prosthetics For more than 20 years, the ANKYLOS system developed by Prof. Dr. G.-H. Nentwig and Dr. Dipl.-Ing. Walter Moser with its TissueCare Connection
More informationMINI IMPLANTS FOR LOWER DENTURE STABLIZATION
MINI IMPLANTS FOR LOWER DENTURE STABLIZATION From the Office of Dr. Michael J. Guy 511A Lakeshore Drive, North Bay ON, P1A 2E3 Mini dental implants (MDI) have become increasingly popular in the past decade
More informationStep-by-Step Virtual Implant Planning MIS Corporation. All Rights Reserved. MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed
More informationplatform shifting Nobel Biocare is shifting gingival beauty to the next level
platform shifting Nobel Biocare is shifting gingival beauty to the next level Nobel Biocare is shifting gingival beauty to the next level Platform Shifting is the latest in Nobel Biocare s offering of
More informationGINGIVAL LEVEL implant
GL GINGIVAL LEVEL implant English version TABLE OF CONTENTS GL - GINGIVAL LEVEL IMPLANT Implant characteristics page 04 Dental implant page 05 Prosthetic components page 06 Ball attachment system page
More informationSupervisors: Dr. Farhan Raza Khan
1 Presenter: Dr. Sana Ehsen Supervisors: Dr. Farhan Raza Khan 2 A dental implant (also known as an endosseous implant or fixture) is a surgical component that interfaces with the bone of the jaw to support
More informationball abutment overdenture: chairside pick-up using existing denture
ball abutment overdenture: chairside pick-up using existing denture This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual,
More informationThe LOCATOR concept. Simplicity and versatility for prosthesis fixation
The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful
More informationDental Updates. Excerpted Article e-mail: re777@comcast.net. Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS
¼ ½ ¾ µ mw/cm 2 Volume 17; 2007 Dental Updates "CUTTING EDGE INFORMATION FOR THE DENTAL PROFESSIONAL " 200 SEMINARS AND 30 JOURNALS REVIEWED YEARLY FOR THE LATEST, CUTTING EDGE INFORMATION Excerpted Article
More informationStraumann Bone Level Tapered Implant Peer-to-peer communication
Straumann Bone Level Tapered Implant Peer-to-peer communication Clinical cases April, 2015 Clinical Cases Case No. Site 1 Single unit; Anterior Maxilla 2 Multi-unit; Anterior Maxilla Implant placement
More informationHigh-Tech Ceramics Dental Implant System: Two Part Metal-Free Natural. User Manual. swiss made. giving nature a hand
e High-Tech Ceramics Dental Implant System: Two Part Metal-Free Natural User Manual swiss made giving nature a hand Giving nature a hand. ZERAMEX, our excellent implant system is fully orientated towards
More informationRestorative Guidelines
Restorative Guidelines Contents Restorative Guidelines 4.1 Neoss Implant System 4.2 4.2 Esthetiline Solution 4.3 4.3 Provisional Abutments 4.8 4.4 Impression Techniques Implant Level 4.12 4.5 NeoLink
More informationprosthetic technique manual
prosthetic technique manual TABLE OF CONTENTS Introduction 1 Treatment Planning 2-5 Restorative Options Implant-level Cement-retained Restorations Implant-level Screw-retained Restorations Abutment-level
More informationImplant Bar Overdenture Utilizing Locator Attachments
Utilizing Locator Attachments Step-by-Step Restorative Protocol Implant Bar Overdentures offer a removable implant solution for edentulous patients desiring a stable and esthetic prosthesis that improves
More informationHEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014
PAGE 1 of 5 References Related ACA Standards 4 th Edition Standards for Adult Correctional Institutions 4-4369, 4-4375 PURPOSE To provide guidelines for determining appropriate levels of care and types
More informationLong-term success of osseointegrated implants
Against All Odds A No Bone Solution Long-term success of osseointegrated implants depends on the length of the implants used and the quality and quantity of bone surrounding these implants. As surgical
More informationPerkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
More informationThe SKY Locator family
The family A new horizon for minimally invasive implant restoration 2 Tel. (+49) 0 73 09 / 8 72-4 40 Fax (+49) 0 73 09 / 8 72-4 44 www.bredent-medical.com e-mail info-medical@bredent.com Treatment concepts
More informationImproving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures
Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures by Timothy F. Kosinski, DDS, MAGD While oral function is the primary concern for most patients, the importance of esthetics
More informationMore than a fixed rehabilitation.
More than a fixed rehabilitation. A reason to smile. In combination with: Patient expectations drive dental treatments for fixed edentulous immediate restorations. Patients today have increasingly high
More informationModern Tooth Replacement Strategies & Digital Workflow
Modern Tooth Replacement Strategies & Digital Workflow Case Studies by Dr Maurice Salama, DMD AS PUBLISHED BY Dentistry Today, June 2014 Complete Implant Restoration System FACTS: Implant Dentistry Has
More informationCHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.
CHAPTER 10 RESTS AND DEFINITIONS A REST is any rigid part of an RPD framework which contacts a properly prepared surface of a tooth. A REST PREPARATION or REST SEAT is any portion of a tooth or restoration
More informationGuidance for implant removal. Straumann Dental Implant System
Guidance for implant removal Straumann Dental Implant System The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research and education. ContentS
More informationImplant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration
Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration ROBERT SCHNEIDER, DDS, MS* ABSTRACT The prosthetic restoration of a
More informationAbout DENTSPLY Implants
Product Catalog About DENTSPLY Implants Improving patient quality of life requires vision, commitment, creativity, and innovation. We are committed to a thorough scientific approach and clinical evidence
More informationTooth Replacement Options
Dr. Jordan Johnson Johnson Dental Associates http://www.beta.mydentalhub.com/ada/test/ (800) 947-4746 Tooth Replacement Options If you re missing one or more teeth, you may be all too aware of their importance
More informationOsseo-integrated Dental Implant Policy and Guidelines
Osseo-integrated Dental Implant Policy and Guidelines 1. PURPOSE The purpose of this document is to outline the Department of Veterans Affairs (DVA) policy regarding the provision of dental implant treatment
More informationDental Implant Restoration
Dental Implant Restoration Principles and Procedures Stuart H. Jacobs Brian C. O Connell London, Berlin, Chicago, Tokyo, Barcelona, Beijing, Istanbul, Milan, Moscow, New Delhi, Paris, Prague, São Paulo,
More informationANGEL DENTAL CARE Implant Consent
This information is to help you make an informed decision about having implant treatment. You should take as much time as you wish to make the decision in relation to signing the following consent form.
More informationA Comprehensive Explanation
Dental Implants A Comprehensive Explanation Overview Since the 1980s, dental implants have become more popular among dentists and patients. 1 In some clinical situations, implants may be the best treatment
More informationTechnique Guide. Screw Removal Set. Instruments for removing Synthes screws.
Technique Guide Screw Removal Set. Instruments for removing Synthes screws. Table of Contents Introduction Screw Removal Set 2 Surgical Technique Preoperative Planning and Preparation 6 Removal of Intact
More informationRestorative Manual Impression Transfer System
Restorative Manual Impression Transfer System Indirect (closed-tray) transfer technique Implant-level indirect transfers for closed-tray, transfer impression technique Designed to transfer the soft tissue
More informationDon t Let Life Pass You By Because Of Oral Bone Loss
Don t Let Life Pass You By Because Of Oral Bone Loss Ask For Dental Implant Solutions From BIOMET 3i Scan With Your Smartphone! In order to scan QR codes, your mobile device must have a QR code reader
More informationCeramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw
38 STARGET 1 I 11 ceramic restorations arne F. BOEcklER and MIcHaEl seitz Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw Introduction
More informationINTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL
INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL Osteo-Ti INTRODUCTION This handbook has been designed to give you a basic understanding of dental implants and related surgery procedures. As with all
More informationThe SATURN implant by Cortex Dental Industries
The SATURN implant by Cortex Dental Industries By Dr. Zvi Laster DMD W e P r o v e I t E v e r y D a y A case report using a newly designed implant specifically designed for immediate post-extraction loading
More informationProsthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: 866-902-9272 781-328-3490. Fax: 866-903-9272 781-328-3400
Contact Us: Implant System Phone: 866-902-9272 781-328-3490 Fax: 866-903-9272 781-328-3400 Prosthetic Manual Mail: Keystone Dental, Inc. 144 Middlesex Turnpike Burlington, MA 01803 USA www.keystonedental.com
More informationRetrospective study on the survival rate of IBS implant
Retrospective study on the survival rate of IBS implant Date : 30. 05. 2013 Written by : Dr. Je Won Wang, Director of research Approved by : Prof. Min Seung Ki - Contents - 1. Purpose Of Study 2. Materials
More informationDENTAL IMPLANTS DR JEBIN,MDS.,D.ICOI
Good Morning DENTAL IMPLANTS DR JEBIN,MDS.,D.ICOI What is implant? A dental implant is an artificial root that replaces the natural tooth root. Crown Gum Implant Tooth Root Jawbone Parts of implant Cover
More informationITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.
ITI Standard Implant Dental Implant System The ITI Dental Implant System was developed in Switzerland by the Institute Straumann and Dr. ndre Schroeder, President of the University ern. ITI implants are
More informationJob Ready Assessment Blueprint. Dental Assisting. Test Code: 4026 / Version: 01
Job Ready Assessment Blueprint Dental Assisting Test Code: 4026 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Introduction to the Dental Assisting Profession
More informationProcedures & Products Powered by Procera. All-on-4
Procedures & Products Powered by Procera All-on-4 First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment
More informationpáêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí
kéï=~ë=çñw= MRKOMNP páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí lééê~íáåö=fåëíêìåíáçåë båöäáëü=erpf Operating Instructions = Sirona Dental Systems GmbH Table of contents 1 Symbols used... 3 2 Product description...
More informationWhile the prosthetic rehabilitation of
Restoring Mandibular Single Teeth with the Inclusive Tooth Replacement Solution Go online for in-depth content by Bradley C. Bockhorst, DMD While the prosthetic rehabilitation of full-arch cases provides
More informationMarch 20, 2015. Dear Mr. Chen:
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center WO66-G609 Silver Spring, MD 20993-0002 March 20, 2015 Biomate
More informationLaboratory Designed Abutment. Optimization By Design
The Laboratory Designed Abutment Optimization By Design Table Of Contents Instructions For Scanning The Laboratory Designed Abutment.... 1 Pouring The Model And Cast... 1 Starting The Scanner.... 1 Calibrating
More informationEncode Restorative System Procedure & Laboratory Manual
Procedure & Laboratory Manual Encode Virtual Abutment Encode Abutment Blank Encode Abutment 1/2 Milled Encode Abutment Completed ENCODE RESTORATIVE SYSTEM Simply Impressive With the introduction of the
More informationMolar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery. Consequences of tooth loss.
Molar Uprighting Dr. Margherita Santoro Division of Orthodontics School of Dental and Oral surgery Molars The wide occlusal surface is designed for food grinding. The surface needs to be aligned with the
More informationMulti-unit abutment bar overdenture
This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit www.biohorizons.com/prostheticmanual.aspx Use this
More informationProcedures & Products. NobelEsthetics
Procedures & Products NobelEsthetics First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment with
More informationSurgical Manual OSSEOTITE Certain Implant Systems And OSSEOTITE External Hex Implant Systems
Surgical Manual OSSEOTITE Certain Implant Systems And OSSEOTITE External Hex Implant Systems No-Touch Mountless OSSEOTITE Certain Implant Delivery System Surgical Protocol Implant Placement Surgical Protocol
More informationDENT IMPLANT restoring qualit S: of LIfE
DENTAL IMPLANTS: restoring quality of life Dental Implants: A Better Treatment Option. What are dental implants? Dental implants are a safe, esthetic alternative to traditional crowns, bridgework, and
More informationAnother Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT
Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT Introduction A 58 year old male had been missing teeth #7=12 for approximately 28 years. During
More informationChapter 6 Aesthetical improvement Use of one-piece type implants
Chapter 6 Aesthetical improvement Use of one-piece type implants 1. Improving esthetics with one-piece implant Director of Kinebuchi Dental Clinic Takao Kinebuchi Aesthetics of two-piece two-stage type
More informationA New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options
A New Beginning with Dental Implants A Guide to Understanding Your Treatment Options Why Should I Replace My Missing Teeth? Usually, when you lose a tooth, it is best for your oral health to have it replaced.
More informationStraumann Dental Implant System. Implant Selection Guide.
Straumann Dental Implant System. Implant Selection Guide. STRAUMANN's IMPLANT PORTFOLIO The Straumann Dental Implant System offers two implant lines with diverse body and neck designs ranging from the
More informationTreatment planning for the class 0, 1A, 1B dental arches
Treatment planning for the class 0, 1A, 1B dental arches Dr.. Peter Hermann Dr Reminder: Torquing movement on tooth supported denture : no movement Class 1 movement in one direction (depression) Class
More informationReplacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation
More informationRehabilitation of a complex case with zirconium dental implants
Rehabilitation of a complex case with zirconium dental Authors_Dr Andrea Enrico Borgonovo, Dr Marcello Dolci, Dr Rachele Censi, Dr Oscar Arnaboldi, Dr Virna Vavassori & Prof Carlo Maiorana, Italy _Introduction
More informationTEPZZ 69 _ZA T EP 2 692 310 A2 (19) (11) EP 2 692 310 A2. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.
(19) TEPZZ 69 _ZA T (11) EP 2 692 3 A2 (12) EUROPEAN PATENT APPLICATION published in accordance with Art. 13(4) EPC (43) Date of publication: 0.02.14 Bulletin 14/06 (21) Application number: 1276632.0 (22)
More information