procedures & products NOBELESTHETICS including Procera

Size: px
Start display at page:

Download "procedures & products NOBELESTHETICS including Procera"

Transcription

1 procedures & products NOBELESTHETICS including Procera

2 First from Nobel Biocare. NOBELPERFECT, (NP, RP, WP), NOBELDIRECT (NP, RP, WP), Brånemark System, NOBELREPLACE and NOBELSPEEDY Implants. A complete assortment with FDA clearance for Immediate Function in all single, partial and fully edentulous restorations in the mandible and maxilla. Nobel Biocare AB and all production units are certified according to the Environmental Management System ISO Some products may not be available in all markets. Please contact your local Nobel Biocare office for current product assortment and availability. Nobel Biocare is in compliance with ISO 13485:1996 and Council Directive 93/42/EEC Canadian Medical Devices Regulation 0086 For USA only: Federal law restricts this device to sale by or on the order of a licensed dentist or physician. All products are subject to change without notice.

3 Table of Contents Beautiful Teeth Now...4 Implant/Abutment Interface Diameter...5 Impression Techniques....6 Temporization...11 Abutment Selection...15 Type of Restoration...16 Procera Abutment...18 Snappy Abutment...21 Easy Abutment...24 Esthetic Abutment Single Tooth Abutment NOBELREPLACE NP...31 GoldAdapt Engaging...33 Procera Implant Bridge...35 Multi-unit Abutment...39 GoldAdapt Non-Engaging...42 Gold Abutment Bar/Gold Coping Bar...44 Ball Abutment Titanium FAQ...50 Manual Torque Wrench...52 OsseoSet...54 Cleaning and Sterilization Recommendation...55 Torque Guide...56 Product Reference Guide

4 Beautiful Teeth Now Congratulations! You have made an excellent choice. Welcome to the Nobel Biocare family. Nobel Biocare is providing dentists with more choices than ever before. But our goals remain the same: To ensure that your patients leave the treatment room satisfied, comfortable, with beautiful teeth, and with a renewed quality of life. To help your practice run more smoothly, efficiently and profitably. This manual is designed to provide quick access to important information regarding treatments, procedures and options for: Brånemark System Mk III Groovy NobelSpeedy Groovy Brånemark System Mk III Brånemark System Mk IV NobelReplace Tapered Groovy NobelReplace Straight Groovy NobelSpeedy Replace Replace Select Tapered Replace Select Straight NobelDirect Posterior The focus of this manual is on the clinical procedures. Additional information on the prosthetic components are found in the NobelEsthetics Prosthetic Products Catalog. For more detailed information on the laboratory procedures, please see the Dental Laboratory Procedure manual. For information about Procera, go to the Procera Laboratory Procedure manual or the Procera Interactive Training CD. For information on clinical procedures for NobelPerfect Groovy, NobelDirect Groovy and NobelDirect Oval. Please see the NobelPerfect Groovy and the NobelDirect Groovy manuals. Nobel Biocare solutions are designed to facilitate: Immediate Function Short & long-term Easy Esthetics Patient comfort and can also be used in Nobel Biocare s pioneering NobelGuide treatment method. See the NobelGuide Manuals/CD for more details. 4

5 Implant/Abutment Interface Diameter Our products are organized according to a platform concept, which facilitates treatment planning. Narrow Platform (NP) for situations in which there is limited inter-dental space or a narrow crest. Regular Platform (RP) for cases ranging from single anterior tooth loss to complete edentulism. Wide Platform (WP) where additional loading can be expected or whenever a wider diameter implant/abutment is considered preferable. 6.0 Platform (6.0) where additional loading can be expected or whenever an even wider diameter implant/abutment is considered preferable. External Connection Brånemark System Mk III Groovy* NobelSpeedy Groovy** Brånemark System Mk III* Brånemark System Mk IV Internal Connection NobelReplace Tapered Groovy NobelReplace Straight Groovy NobelSpeedy Replace Replace Select Tapered Replace Select Straight One-Piece Implants NobelDirect Posterior External Connection NP 3.5 mm interface RP 4.1 mm interface WP 5.1 mm interface Internal Connection NP 3.5 mm interface RP 4.3 mm interface WP 5.0 mm interface mm interface NOBELDIRECT Posterior RP 4.3 mm WP 5.0 mm mm Interface Diameter Interface Diameter *For RP 3.75 and RP 4 implants, use RP prosthetic components ** For WP 5 and WP 6 implants, use WP prosthetic components 5

6 Impression Techniques To restore an implant, the laboratory model needs to have either an implant replica or abutment replica. The only exception is with abutments that are modified in the mouth; these are reproduced in stone or acrylic in procedures identical to preparations on natural teeth. Impression Implant Level The purpose of the implant level impression is to crossreference the position of the implant platform in relation to other implants, teeth and soft tissue contours. The implant level impression is generally made when a one-stage procedure is utilized, or the indexing of implant position is desired, before soft tissue closure at the time of implant placement. However, an implant level impression may also be made after second-stage surgery, after a healing abutment or temporary restoration has been in place and the soft tissue has healed. The implant level impression coping is connected to the implant and the impression is made with an elastic material with either an open or closed tray. Information from the implant platform is transferred via the impression coping and implant replica to the stone model. The implant replica allows restorative components to be seated and removed from the dental cast during abutment selection and fabrication of the provisional or final restoration. Note: For implants that are greater than 25 divergent, the open tray technique must be used. 6

7 Closed Tray Technique 1. Place the impression coping over the implant. Use the Unigrip Screwdriver and tighten the screw (for NobelReplace only). The Impression Coping Closed Tray Plastic NobelReplace, which is intended to be used for single units and short span bridges with parallel implants, is pressed into the implant. 2. Block out the Unigrip hole on the guide pin (for NobelReplace only). A radiograph may be taken to verify proper seating of the impression coping. 3. Inject a heavy body impression material (polyether material or polyvinylsiloxane) around each impression coping and into the tray. Record the impression. 4. Remove the impression. 5. Remove the impression coping and thread it onto the corresponding implant replica. 6. Place the impression coping implant replica assembly into its corresponding location in the impression and send to the dental laboratory for model fabrication Open Tray Technique An alternative technique for taking an implant level impression. This is useful when: It is preferred to have the impression coping retained in the impression material to avoid uncertainty with re-seating. The lack of implant parallelism would make tray removal difficult using the closed tray technique. The height of the implant level impression coping is significantly below the occlusal plane. 1. Place the impression coping over the implant and tighten the guide pin using the Unigrip Screwdriver. 2. Relieve and perforate the impression tray to allow full seating of the tray and protrusion of the guide pins. If there is a large opening, it may be closed off using baseplate wax, with the guide pins indenting or perforating the wax. 3. Inject impression material around each impression coping and fill the tray; seat the impression tray fully so that the tips of all the guide pins are identified. After the impression material has set, unscrew each guide pin. Pull each guide pin with cotton pliers to verify full disengagement. Remove the impression tray. 4. Attach the appropriate implant replicas to the impression copings for model fabrication. Note: It is important that no forces are transferred to the impression coping while fastening the replica; this could twist the position of the coping in the impression material. A firm grip on the replica while tightening the guide pin will help prevent any dislodgement of the impression coping from it s reference position

8 Product List for Clinical Procedures External Connection Internal Connection Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm Impression Abutment Level The impression techniques (closed or open tray) are the same for straight and angled Multi-unit abutments and all platforms (NP/RP/WP). The abutment level impression coping is connected to the Multi-unit abutment and the impression is made with an elastic material with either an open or closed tray. Information from the abutment is transferred via the impression coping and abutment replica to the stone model. The abutment replica allows restorative components to be seated and removed from the dental cast during fabrication of the provisional or final restoration. Note: For implants that are greater than 25 divergent, the open tray technique must be used. 8

9 Closed Tray Technique 1. Place the impression coping and rotate it into position on the abutment until complete seating is achieved. 2. Inject a heavy body impression material (polyether material or polyvinylsiloxane) around each impression coping and into the tray. Record the impression. 3. Remove the impression. 4. Remove the impression copings from the abutment and attach the abutment replicas to each coping. 5. Place the impression coping abutment replica assembly into its corresponding location in the impression and send to the dental laboratory for model fabrication Open Tray Technique 1. Place the impression coping on the abutment and tighten the guide pin using the Unigrip Screwdriver. 2. Relieve and perforate the impression tray to allow full seating of the tray and protrusion of the guide pins. If there is a large opening, it may be closed off using baseplate wax, with the guide pins indenting or perforating the wax. 3. Inject impression material around each impression coping and fill the tray; seat the impression tray fully so that the tips of all the guide pins are identified. After the impression material has set, unscrew each guide pin. Pull each guide pin with cotton pliers to verify full disengagement. Remove the impression tray. 4. Attach the appropriate implant replicas to the impression copings for model pouring. Note: It is important that no forces are transferred to the impression coping while fastening the replica; this could twist the position of the coping in the impression material. A firm grip on the replica while tightening the guide pin will help prevent any dislodgement of the impression coping from its reference position Impression techniques on abutment level for Snappy Abutment, Easy Abutment and Ball Abutment Titanium, see pages 21, 24 and 47. 9

10 Product List for Clinical Procedures Impression Coping Closed Tray Multi-unit External Connection Internal Connection Impression Coping Open Tray Multi-unit Abutment Replica Multi-unit Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 10

11 Temporization Depending on the final restoration planned, several alternatives in provisional restorations are possible. It is best to have a temporization strategy to meet patient requirements during different phases of treatment planning. One-Stage Function As for crown & bridge, temporization may be performed in many different ways, from the use of a standard acrylic crown, adjusted chairside, to a lab-processed temporary crown. It is important to have a smooth contour on the provisional crown to avoid irritating the soft tissue. Care should be taken not to contaminate the surgical site with impression material or cement. For the Snappy Abutments, Easy Abutments, Esthetic Abutments and Multi-unit Abutments, temporary copings are available using the same principles as for crown & bridge. In some situations, Nobel Biocare Temporary Abutments can be used for the temporary prosthesis. For single unit temporary restorations there is an Immediate Temporary Abutment available. 11

12 Two-Stage Function Before implants are uncovered For the totally edentulous patient after implant insertion, use the existing denture that has been adjusted and relined. For the partially edentulous patient after implant insertion, use suitable conventional temporization procedures. After implants are uncovered Provisional restorations can be made on temporary components as the needs of the patient and the treatment plan dictate. Indexing at the time of implant placement, can allow the fabrication of an abutment and/or provisional restoration to be delivered at the time of implant uncovering. Temporary Restorations For fabrication of temporary restorations, there are several options. For cemented restorations, using the Snappy Abutments, Easy Abutments, Esthetic Abutments and Procera Abutments, temporary crowns or bridges are made with the same techniques used for natural teeth. For Multi-unit Abutments, provisional restorations can be fabricated by processing acrylic or composite to temporary copings. 1. Immediate Temporary Abutment Immediate Temporary Abutments and Copings are used for single unit implant supported temporary dental restorations, made chair-side. The Immediate Temporary Abutment consists of two parts, an abutment and a plastic coping. 1. The abutment is mounted onto the implant and tightened with the Screwdriver Machine Multi-unit and Manual Torque Wrench Prosthetic to 35 Ncm. 2. The abutment post is adjusted for height and clearance if necessary. 3. The plastic coping is tried-in and relieved for clearance if necessary. 4. A temporary crown is fabricated with traditional methods using either acrylic or composite. Warning: Do not use with Polyurethane cements. The cement will not cure

13 Temporary Abutments/Copings The standard temporary abutments and copings, used for the fabrication of provisional restorations, are made of titanium or plastic. The retentive groove on the abutments/copings will help to bind acrylic material when building a provisional construction. 1. Provisional restorations may be made either at a dental laboratory or chair-side. The provisional restoration is fabricated directly on the temporary abutments/copings. For the direct chair-side method, an acrylic template for the provisional restoration can be made from either a wax-up or denture tooth set-up representing the planned restoration. 1. Fasten the temporary abutments/copings in the mouth or on the model. Use guide pins that extend beyond the occlusal plane. 2. Make holes in the acrylic template to allow the guide pins and temporary abutments/copings to protrude. 3. Examine undercuts associated with adjacent natural teeth and block out as necessary. 4. Fill the acrylic template with acrylic and seat over the guide pins and temporary abutments/copings. 5. After setting, loosen the guide pins to remove the restoration. 6. Laboratory protection analogs can be attached to the bottom of the abutments/copings to protect the base during trimming and polishing procedures. The provisional restoration is fastened with the corresponding abutment screw/prosthetic screw. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling material Principle Clinical Procedure for Connecting a Provisional Restoration For Screw-Retained Provisional Restorations: The provisional restoration is fastened with the corresponding abutment screw/prosthetic screw. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling. For Cement-Retained Provisional Restorations: The provisional restoration must be cemented with retrievable temporary cement. Remove any excess cement and adjust the occlusion. 13

14 Product List for Clinical Procedures Immediate Temporary Abutment Includes: Plastic Coping Immediate Temporary Abutment External Connection Internal Connection Temporary Abutment Engaging Titanium with Abutment Screw Temporary Abutment Non-Engaging Titanium with Abutment Screw Temporary Abutment Plastic Engaging without Abutment Screw Temporary Abutment Plastic Non-Engaging without Abutment Screw Temporary Coping Multi-unit Titanium with Prosthetic Screw Temporary Coping Multi-unit Plastic without Prosthetic Screw Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 14

15 Abutment Selection If the final restoration is to meet the esthetic and functional demands of the dentist and patient, selecting the proper abutment is crucial. In some cases, the dentist makes the abutment selection and sends an abutment level impression to the laboratory. However in many cases, the dentist takes an impression at fixture level to facilitate the abutment choice. Try-in Abutments In order to facilitate the abutment selection there are now plastic Try-in Abutments available with internal or external connections. These are intended to be momentarily placed into an implant (intra-orally) or implant replica (dental laboratory) to aid the clinician or dental technician in the selection of an appropriate shape and size abutment for the patient. The Try-in Abutments are available for Snappy Abutments, straight and angled Esthetic Abutments and angled Multi-unit Abutments. A soft tissue measuring tool is included along with the Try-in Abutment. Try-in Abutments for External Connection Indications The Abutment Try-ins are indicated for partially or fully edentulous patients receiving implant treatment with NobelReplace or Brånemark System Implants. Cleaning and Sterilization The Abutment Try-ins are reusable by the dentist or laboratory. They may be cleaned and sterilized prior to patient use as required in compliance with established routines at the hospital/clinic. Try-in Abutments for Internal Connection Cement-Retained Cement-retained restorations on implants follow the same basic protocol as tooth-supported crowns and fixed partial denture restorations. While the abutments are screw-retained in to the implants, the restoration is cemented over the abutments. The use of temporary cement is recommended for ease of retrievability. Note: Do not use temporary cement for Procera Crowns or Procera Bridge Zirconia. Screw-Retained A screw-retained restoration is retained by screws that enter through the occlusal or cingulum area of the restoration. The screw passes through the crown and threads into the abutment screw. The restoration is retrievable by the dentist. 15

16 Type of Restoration Single Tooth Restoration Cement-Retained Procera Abutment Zirconia or Titanium Snappy Abutment Titanium Easy Abutment Titanium Esthetic Abutment Angled, Straight Titanium Single Tooth Abutment Titanium GoldAdapt Engaging External NP/RP/WP External NP/RP/WP External NP/RP/WP External NP/RP/WP Internal NP External NP/RP/WP Internal NP/RP/WP/6.0 Internal NP/RP/WP/6.0 Internal NP/RP/WP/6.0 Internal NP/RP/WP/6.0 Internal NP/RP/WP/6.0 Octagon 4.8 Multiple Unit Restoration Cement-Retained Procera Abutment Zirconia or Titanium External NP/RP/WP Internal NP/RP/WP/6.0 Octagon 4.8 Snappy Abutment Titanium External NP/RP/WP Internal NP/RP/WP/6.0 Easy Abutment Titanium External NP/RP/WP Internal NP/RP/WP/6.0 Esthetic Abutment Angled, Straight Titanium External NP/RP/WP Internal NP/RP/WP/6.0 GoldAdapt Engaging External NP/RP/WP Internal NP/RP/WP/6.0 the interface part is not illustrated 16

17 Single Tooth Restoration Screw-Retained GoldAdapt Engaging External NP/RP/WP Internal NP/RP/WP/6.0 Multiple Unit Restoration Screw-Retained Multi-unit Abutment Titanium Multi-unit Angled Abutment Titanium GoldAdapt Non-Engaging Procera Implant Bridge Titanium External NP/RP/WP External NP/RP External NP/RP/WP External NP/RP/WP Internal NP/RP/WP Internal NP/RP Internal NP/RP/WP/6.0 Internal NP/RP/WP/6.0 Octagon 4.8/6.5 Overdenture Restoration Bar-Retained Ball-Retained Gold Abutment Bar Multi-unit Abutment Titanium Multi-unit Angled Abutment Titanium Ball Abutment Titanium External RP Internal NP/RP External NP/RP/WP Internal NP/RP/WP External NP/RP Internal NP/RP External RP Internal NP/RP Gold Coping Bar the interface part is not illustrated 17

18 Procera Abutment Zirconia, Titanium Single Tooth and Multiple Unit Restorations Cement-Retained Indications Single or multiple implant restorations Fully edentulous or partially edentulous arch 1. Impression 1. Place the impression coping implant level onto the implant. To transfer the position of the implant to a working model, take an impression on implant level (see the chapter: Impression Techniques). 2. Connect the temporary restoration (see the chapter: Temporization), or healing abutment and send the impression to the dental laboratory. 2. Laboratory Procedure Wax-up technique The Procera Abutment wax-up kit with different platform replicas is used to create a wax-up pattern. After scanning the wax-up pattern with Procera Scanner, the data is transferred to a production facility via Internet. 3D CADD technique Procera 3D CADD program is used to create a computerized design for Procera Abutment. The contour, alignment and finish line are designed on the screen. When the design is completed, data is transferred to the production facility via Internet. 3. Procera Production Facility The abutment is produced and returned to the laboratory. 18

19 4. Laboratory Procedure In the laboratory the abutment is scanned for a Procera Crown or Procera Bridge Zirconia, which after production will be veneered with NobelRondo porcelain. Note: When designing/preparing Procera Abutment Zirconia, make sure that the thickness of the ceramic material is at least 0.8 mm. This thickness limit is applicable up to a height of 3 mm above implant level. 5. Abutment Connection 3. Remove the temporary restoration or healing abutment from the implant. Ensure that the implant platform is free from any soft-tissue or bone remnants. 4. Insert the abutment screw into the screw access channel using the Unigrip Screwdriver. Position the abutment/screw assembly into the implant and secure the screw in the implant until resistance is felt. A radiograph can be helpful to confirm accurate seating of the abutment. Note: When using the Procera Abutment with external connection on compatible hex implants, use the screw supplied with the abutment. 5. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 6. Cementation of Final Restoration 6. Gently seat the restoration on the abutment and check both the occlusion and the interproximal contacts. The restoration should be in light occlusion. Excursive contact should be minimal. 7. Cement the restoration using permanent cement. 19

20 Procera Abutment Octagon Procera Abutments are also available in both titanium and zirconia for Straumann Regular Neck 4.8 mm implants Procera Abutment Octagon. Simply follow the normal laboratory procedure for Procera Abutment and the clinical procedure for Straumann implants. Product List for Clinical Procedures External Connection Internal Connection Procera Abutment Includes: Abutment Screw Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Note: For temporary components see page 14. Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 20

21 Snappy Abutment Titanium Cement-Retained Single Tooth and Multiple Unit Restorations Note: The NobelDirect Posterior Implant has an integrated abutment portion, which is identical to the Snappy Abutment and thus uses the same prosthetic components. Indications The abutments are ideal for posterior, partially edentulous restorations and single implant restorations 1. Abutment Connection 1. Insert the abutment screw into the screw access channel using the Unigrip Screwdriver. Position the abutment/screw assembly into the implant and secure the screw until resistance is felt. A radiograph can help to confirm accurate seating of the abutment to the implant. 2. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 2. Impression 3. Using light finger pressure, press the impression coping onto the Snappy Abutment. A snap will indicate that the impression coping is fully engaged and well adapted to the margin of the Snappy Abutment. Note the plastic tabs inside the impression coping fit into the top of Snappy Abutment. 4. Take a standard impression. When the impression is pulled, the impression coping will disengage from the Snappy Abutment and is picked up in the impression. 5. Insert the Abutment Replica Snappy Abutment into the Impression Coping and send the impression to the dental laboratory for model and prosthetic fabrication. 21

22 3. Temporary Restoration 6. Clean and remove any debris from the Snappy Abutment. Use the Manual Torque Wrench Prosthetic to verify the tightening to 35 Ncm of the abutment screw. Provisionalize the Snappy Abutment chair-side using the plastic/temporary coping, or use the healing cap that is included in the Snappy Abutment package. Warning: Do not use Plastic/Temporary Coping Snappy Abutment with polyurethane cements. The cement will not cure. 4. Laboratory Procedure In the laboratory a model is made and the restoration is produced. Alternatives: Procera Crown veneered with NobelRondo Procera Bridge Zirconia veneered with NobelRondo Plastic/Temporary Coping Snappy Abutment in a cast restoration 5. Cementation of Final Restoration 7. Remove the healing cap or temporary prosthesis using the Unigrip Screwdriver. Cement the restoration over the abutment. Use provisional cement if greater ease of retrievability is desired. Note: Only use permanent cement when cementing ceramic crowns or bridges. 22

23 Product List for Clinical Procedures Snappy Abutment Includes: Abutment Screw Healing Cap Impression Coping External Connection Internal Connection Impression Coping Snappy Abutment Abutment Replica Snappy Abutment Healing Cap Snappy Abutment Plastic/Temporary Coping Snappy Abutment Engaging/Non-Engaging Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 23

24 Easy Abutment Titanium Cement-Retained Single Tooth and Multiple Unit Restorations Indications The abutments are ideal for posterior, partially edentulousrestorations and single implant restorations 1. Abutment Connection 1. Insert the abutment screw into the screw access channel using the Unigrip Screwdriver. Position the abutment/ screw assembly into the implant and tighten the screw until resistance is felt. A radiograph can help to confirm accurate seating of the abutment to the implant. 2. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 35 Ncm Modifications, if needed Remove the abutment, place it on an implant replica and modify it with a carborundum disk and carbide bur. If the modification is made intra-orally, use profuse water irrigation. Note: Occlusal reduction of the Easy Abutment must not exceed 1 mm or the abutment screw will be compromised. 2. Impression 3. Mount the purple screw access plug in the Easy Abutment screw access channel using a perioprobe. If the top of the abutment has been modified, block out the channel with wax, cotton or other appropriate material. 4. Using light finger pressure, press the impression cap onto the Easy Abutment. A snap will indicate that the impression cap is fully engaged and well adapted to the margin of the Easy Abutment. Note: If the Easy Abutment has been modified, do not use the impression cap; instead, take a standard C&B impression and send to laboratory. 24

25 5. Use the included centrix injection tip to slowly inject impression material into the hole on top of the impression cap. Continue until the impression material extrudes out of the lateral vent holes of the impression cap. Note: For best results, care should be taken to avoid bottoming out the injection tip inside the snap-on impression cap. 6. Take a standard impression. When the impression is pulled, the impression cap will disengage from the Easy Abutment and will be picked up in the impression. The screw access plug is often picked up in the impression material. Remove the screw access plug from the impression with an explorer. 7. Insert the Abutment Replica Easy Abutment into the impression cap and send the impression to the dental laboratory. 3. Temporary Restoration 8. Clean and remove any debris from the Easy Abutment. Use the Manual Torque Wrench Prosthetic to verify the tightening to 35 Ncm of the abutment screw. Provisionalize the Easy Abutment using the temporary coping, or use the healing cap that is included in the Easy Abutment package. Remove the screw access plug and place the healing cap using the Unigrip Screwdriver without over-tightening. Never place the healing cap on the Easy Abutment unless the abutment screw has been tightened to 35 Ncm. Warning: Do not use Temporary Coping Easy Abutment with polyurethane cements. The cement will not cure. 4. Laboratory Procedure In the laboratory a model is made and the restoration is produced. Alternatives: Procera Crown veneered with NobelRondo Procera Bridge Zirconia veneered with NobelRondo Ceramic Coping Easy Abutment with NobelRondo Plastic Coping Easy Abutment in a cast restoration 25

26 5. Cementation of Final Restoration 9. Remove the temporary prosthesis or healing cap using the Unigrip Screwdriver. Cement the restoration on the abutment. Use provisional cement if greater ease of retrievability is desired. Note: The screw access plug may be utilized to block out the screw access channel prior to cementation of the final restoration provided that the abutment has not been modified. Note: Only use permanent cement when cementing ceramic crowns or bridges. 26

27 Product List for Clinical Procedures External Connection Internal Connection Easy Abutment Includes: Abutment Screw Healing Cap Impression Coping Centrix Injection Tip Screw Access Plug Impression Cap Easy Abutment Includes: Centrix Injection Tip Screw Access Plug Abutment Replica Easy Abutment Healing Cap Easy Abutment Temporary Coping Easy Abutment Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 27

28 Esthetic Abutment Titanium Cement-Retained Single Tooth and Multiple Unit Restorations The following description is based on straight Esthetic Abutments. The same procedures are used for the 15 Esthetic Abutments. The abutment is designed with a scalloped margin that profiles natural soft tissue contours with various collar heights available based on the implant platform and system. Indications Single or multiple implant restoration Fully edentulous or partially edentulous arch 1. Abutment Connection 1. Insert the abutment screw into the screw access channel using the Unigrip Screwdriver. Position the abutment/screw assembly into the implant and tighten the screw in the implant until resistance is felt. A radiograph can help to confirm accurate seating of the abutment. 2. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. Modification, if needed Remove the abutment, place it on an implant replica and modify it with a carborundum disk and carbide bur. If the modification is made intra-orally, use copious water irrigation. 2. Impression 3. Take a standard C&B impression. 4. Send the impression to the dental laboratory. 28

29 3. Temporary Restoration Clean and remove any debris from the Esthetic Abutment. Use the Manual Torque Wrench Prosthetic to verify the tightening to 35 Ncm of the abutment screw. Provisionalize the Esthetic Abutment using the plastic/temporary coping. Warning: Do not use with polyurethane cements. The cements will not cure. 4. Laboratory Procedure In the laboratory, a model is made and a restoration is produced. Alternatives: Procera Crown veneered with NobelRondo Procera Bridge Zirconia veneered with NobelRondo Plastic/Temporary Coping Esthetic Abutment in a cast restoration. 5. Cementation of Final Restoration 5. Gently seat the restoration on the abutment and check both the occlusion and the interproximal contacts. The restoration should be in light occlusion. Excursive contact should be minimal. 6. Cement the restoration using provisional or permanent cement. Note: Only use permanent cement when cementing ceramic crowns or bridges. 29

30 Product List for Clinical Procedures Esthetic Abutment Includes: Abutment Screw External Connection Internal Connection Esthetic Abutment 15 Includes: Abutment Screw Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Plastic/Temporary Coping Esthetic Abutment Available as straight/15 Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 30

31 Single Tooth Abutment NOBELREPLACE NP Titanium Cement-Retained Single Tooth Restoration Indications Single implant restoration with limited interdental space 1. Impression 1. Place the impression coping implant level onto the implant. To transfer the position of the implant to a working model, take an impression implant level (see the chapter: Impression Techniques). 2. Connect the healing abutment or temporary restoration (see the chapter: Temporization), and send the impression to the laboratory. 2. Laboratory Procedure In the laboratory, a model is made, the abutment is modified, if needed, and a restoration is made. Alternatives: Procera Crown veneered with NobelRondo Conventional C&B 3. Abutment Connection 3. Remove the temporary restoration or healing abutment from the implant. Ensure that the implant platform is free from any soft tissue or bone remnants. 4. Insert the abutment screw into the screw access channel of the abutment using the Unigrip Screwdriver. Position the abutment/screw assembly into the implant and tighten the screw in the implant until resistance is felt. If a template has been produced, use this for guiding the abutment into the right position. A radiograph can help to confirm accurate seating of the abutment. 5. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 31

32 4. Cementation of Final Restoration 6. Gently seat the restoration on the abutment and check both the occlusion and the interproximal tooth contacts. The restoration should be in light occlusion and excursive contact should be minimal. 7. Cement the restoration using provisional cement or permanent cement. Note: Only use permanent cement when cementing ceramic crowns. Product List for Clinical Procedures Internal Connection Single Tooth Abutment NOBELREPLACE NP Impression Coping Implant Level Closed Tray Implant Replica Note: For temporary components see page 14 Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 32

33 GoldAdapt Engaging Screw-Retained Single Tooth Cement-Retained Single Tooth and Multiple Unit Restorations This instructions is for screw-retained restorations only. Indications Single or multiple implant restorations Screw access hole location through occlusal surface of posterior teeth or cingulum of anterior teeth without angle correction Limited interocclusal space Limited interdental space 1. Impression 1. Place the impression coping implant level onto the implant. To transfer the position of the implant to a working model, take an impression implant level (see the chapter: Impression Techniques). 2. Connect the healing abutment or temporary restoration (see the chapter: Temporization), and send the impression to the laboratory. 2. Laboratory Procedure In the laboratory a model is made, a GoldAdapt is connected and a conventional C&B restoration is made. 3. Connection of Final Restoration 3. Remove the temporary restoration or healing abutment from the implant. Ensure that the implant platform is free from any soft tissue or bone remnants. 4. Insert the abutment screw into the screw access channel of the restoration using the Unigrip Screwdriver. Position the restoration/screw assembly into the implant and tighten the screw in the implant until resistance is felt. A radiograph can help to confirm accurate seating of the abutment. 5. Check both the occlusion and the interproximal contacts. The restoration should be in light occlusion and excursive contact should be minimal. 6. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 7. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling material. 33

34 Product List for Clinical Procedures GoldAdapt Engaging Includes: Abutment Screw External Connection Internal Connection Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Note: For temporary components see page 14 Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 34

35 Procera Implant Bridge Titanium Screw-Retained Multiple Unit Restoration Indications Fully edentulous or partially edentulous arch Implant level or abutment level 1a. Impression Implant Level 1. Place impression copings implant level onto the implants using guide pins for connection. To transfer the position of the implant to a working model, take an impression at implant level (see the chapter: Impression Techniques). 2. Connect the temporary restoration (see the chapter: Temporization) or healing abutment and send the impression to the laboratory. 1b. Impression Abutment Level 1. Place the Impression Copings Multi-unit onto the Multi-unit Abutments. To transfer the position of the abutment to a working model, take an impression on abutment level (see the chapter: Impression Techniques). 2. Connect the temporary restoration (see the chapter: Temporization) or healing cap and send the impression to the laboratory. 2. Laboratory Procedure In the laboratory, a model is made and a resin framework is produced and is sent to a Procera production facility. 3. In Procera Production Facility The framework is milled from a solid piece of titanium and returned to the laboratory. 4. Laboratory Procedure The restoration is completed using conventional methods. 35

36 5a. Connection of Final Restoration on Implant Level 3. Remove the temporary restoration or healing abutments from the implants. Ensure that the implants are free from any soft tissue or bone remnants. 4. Connect the restoration to the implants with abutment screws. Start with the mid region post and tighten the following screws alternating left and right sides. 5. Tighten the abutment screws to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 6. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling material. Note: When using Procera Implant Bridge with external connection on compatible hex implants, use screw intended for the Brånemark System platform. 5b. Connection of Final Restoration on Abutment Level 3. Remove the temporary restoration or healing caps from the abutments. 4. Connect the restoration to the abutments with prosthetic screws. Start with the mid region post and tighten the following screws alternating left and right sides. 5. Tighten the prosthetic screws to 15 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 6. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling material. 15 Ncm Procera Implant Bridge Octagon The Procera Implant Bridge is also available at implant level for Straumann Regular Neck 4.8mm and Wide Neck 6.5 mm implants Procera Implant Bridge Octagon. You simply follow the normal laboratory procedure for Procera Implant Bridge and the clinical procedure for Straumann implants. 36

37 Product List for Clinical Procedures Procera Implant Bridge - at Implant or Abutment Level Does not include Abutment Screws/Prosthetic Screws External Connection Internal Connection Implant Level Components Abutment Screw Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Abutment Level Components Multi-unit Abutment Available as straight, 17, 30 Includes: Abutment Screw Prosthetic Screw Multi-unit Impression Coping Closed Tray Multi-unit Impression Coping Open Tray Multi-unit 37

38 Product List for Clinical Procedures External Connection Internal Connection Abutment Replica Multi-unit Healing Cap Multi-unit Available as regular/wide Note: For temporary components see page 14. Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 38

39 Multi-unit Abutment Titanium Screw-Retained Multiple Unit Restoration Indications Multiple unit screw-retained restoration Fully edentulous or partially edentulous arch Desire for greater ease of retrievability 1a. Abutment Connection Straight Multi-unit Abutment 1. Use the pre-mounted plastic holder to place the abutment into the implant and screw the abutment into the correct position. 2. If necessary, shorten the holder with a pair of scissors. 3. When the abutment is seated, the disposable plastic holder should be removed with a slight bending movement. A radiograph can be helpful to confirm accurate seating of the abutment. 4. Tighten the abutment screw to 35 Ncm using the Manual Torque Wrench Prosthetic and Screwdriver Machine Multi-unit. 1b. Abutment Connection 17 and 30 Multi-unit Abutment 1. The abutment is placed over the implant by using the pre-mounted abutment holder. Please note that there are several possible positions to place the abutment. 2. Tighten the abutment screw using a Unigrip Screwdriver until resistance is felt. A radiograph can help to confirm accurate seating of the abutment. 3. The disposable holder is then unscrewed from the abutment by turning it counter-clockwise. 4. Tighten the abutment screw to 15 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver 35 Ncm Note: Be sure not to exceed 15 Ncm. 39

40 2. Impression 5. Place the impression coping abutment level onto the abutment. To transfer the position of the abutment to a working model, take an impression at abutment level (see the chapter: Impression Techniques). 6. Connect the temporary restoration (see the chapter: Temporization), or healing cap and send the impression to the dental laboratory. 3. Laboratory Procedure In the laboratory, a model is made and a restoration is produced. Alternatives: Procera Implant Bridge Gold Coping Multi-unit in cast restoration 4. Connection of Final Restoration 7. Remove the temporary restoration or healing caps from the abutments. 8. Connect the restoration to the abutments with prosthetic screws. Start with the mid region post and tighten the following screws alternating left and right sides. 9. Tighten the prosthetic screws to 15 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 10. Fill the screw access channel with a suitable material such as gutta percha, silicone or temporary filling material. 15 Ncm 40

41 Product List for Clinical Procedures External Connection Internal Connection Multi-unit Abutment Available as straight, 17, 30 Includes: Abutment Screw Prosthetic Screw Multi-unit for connection of Procera Implant Bridge Impression Coping Closed Tray Multi-unit Impression Coping Open Tray Multi-unit Abutment Replica Multi-unit Healing Cap Available as regular/wide Note: For temporary components see page 14. Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 41

42 GoldAdapt Non-Engaging Screw-Retained Multiple Unit Restoration Indications Multiple implant restoration screw-retained Limited interocclusal space Screw access hole location through occlusal surface of posterior teeth or cingulum of anterior teeth without angle correction Implants with less than 40 overall divergence to allow path of insertion 1. Impression 1. Place the impression copings implant level onto the implant. To transfer the position of the implants to a working model, take an impression implant level (see the chapter: Impression Techniques). 2. Connect the temporary restoration (see the chapter: Temporization), or healing abutments and send the impression to the dental laboratory. 2. Laboratory Procedure In the laboratory a model is made, GoldAdapts are connected and a conventional C&B restoration is made. 3. Connection of Final Restoration 3. Remove the temporary restoration or healing abutments from the implants. Ensure that the implant platforms are free from any soft-tissue or bone remnants. 4. Insert the abutment screws into the screw access channels of the restoration using a Unigrip Screwdriver. Position the restoration/screw assembly into the implants and tighten the screws in the implants until resistance is felt. A radiograph can be helpful to confirm accurate seating of the abutment. 5. Check both the occlusion and the interproximal contacts. The restoration should be in light occlusion and excursive contact should be minimal. 6. Tighten the abutment screws to 35 Ncm using the Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 7. Fill the screw access channels with a suitable material such as gutta percha, silicone or temporary filling. 42

43 Product List for Clinical Procedures GoldAdapt Non-Engaging Includes: Abutment Screw External Connection Internal Connection Impression Coping Implant Level Closed Tray Alternatives for internal connection: Low Profile Plastic Impression Coping Implant Level Open Tray Implant Replica Note: For temporary components see page 14. Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 43

44 Gold Abutment Bar/ Gold Coping Bar Overdenture Restoration Bar-Retained Indications Fully edentulous arch Financially compromised patients Extensive bone or soft tissue loss Compromised patient manual dexterity Necessity for soft tissue support Phonetic concerns Implant Supported Overdenture Maxilla: 6 to 8 implants Mandible: 4 or more implants The number of implants is important, but not the only factor, in determining the load potential Resilient Tissue Supported Overdenture Maxilla: 4 or more implants Mandible: 2 or more implants 1a. Impression Implant Level 1. Place the Impression Copings Bar onto the implants. To transfer the position of the implants at a working model, take an impression with a custom tray at implant level. 1b. Impression Abutment Level 1. Place the Impression Copings Bar Multi-unit onto the abutments. To transfer the position of the abutments to a working model, take an impression with a custom tray on abutment level (see the chapter: Impression Techniques). 2. Laboratory Procedure In the laboratory a model is made and an occlusal rim with incorporated gold abutments/gold copings is produced. 3. Jaw Relationship 2. Secure the occlusal rim to the implants or abutments with abutment screw/prosthetic screw or short guide pins. 3. Record the jaw relationship. 44

45 4. Laboratory Procedure The bar is soldered to the gold abutments/gold copings and a tooth set-up in wax is produced. 5. Clinical Try-in 4. Evaluate wax try-in. 6. Laboratory Procedure In the laboratory the overdenture is processed. 7a. Connection of Final Restoration Implant Level 5. Tighten the abutment screws to 35 Ncm using Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 6. Deliver the denture. Adjust the retention. Verify the occlusal relationships, confirm resiliency and hinge axis movement. 7b. Connection of Final Restoration Abutment Level 7. Check the tightness of the abutment screws. Tighten the prosthetic screws to 15 Ncm using Manual Torque Wrench Prosthetic and Unigrip Machine Screwdriver. 8. Deliver the denture. Adjust the retention. Verify the occlusal relationships, confirm resiliency and hinge axis movement. 15 Ncm 45

46 Product List for Clinical Procedures Gold Abutment Bar Includes: Abutment Screw External Connection Internal Connection Gold Coping Bar Multi-unit Includes: Prosthetic Screw Impression Coping Bar Implant Level Closed Tray Implant Replica Impression Coping Bar Closed Tray Multi-unit Abutment Replica Multi-unit Instrumentation Prosthetic Kit Includes: Manual Torque Wrench Prosthetic Screwdriver Machine Unigrip 20 mm Screwdriver Machine Unigrip 30 mm Screwdriver Machine Multi-unit 21 mm 46

Procedures & Products. NobelEsthetics

Procedures & Products. NobelEsthetics Procedures & Products NobelEsthetics First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment with

More information

NobelActive. procedures and products

NobelActive. procedures and products NobelActive procedures and products precautions and warnings Manufacturer: Nobel Biocare AB, Box 5190, SE-402 26 Göteborg, Sweden. Phone: +46 31 81 88 00. Fax: +46 31 16 31 52 www.nobelbiocare.com Important!

More information

Restorative Guidelines

Restorative Guidelines Restorative Guidelines Contents Restorative Guidelines 4.1 Neoss Implant System 4.2 4.2 Esthetiline Solution 4.3 4.3 Provisional Abutments 4.8 4.4 Impression Techniques Implant Level 4.12 4.5 NeoLink

More information

platform shifting Nobel Biocare is shifting gingival beauty to the next level

platform shifting Nobel Biocare is shifting gingival beauty to the next level platform shifting Nobel Biocare is shifting gingival beauty to the next level Nobel Biocare is shifting gingival beauty to the next level Platform Shifting is the latest in Nobel Biocare s offering of

More information

Procedures & Products Powered by Procera. All-on-4

Procedures & Products Powered by Procera. All-on-4 Procedures & Products Powered by Procera All-on-4 First from Nobel Biocare. NobelPerfect, (NP, RP, WP), NobelDirect (NP, RP, WP), Brånemark System, NobelReplace and NobelSpeedy Implants. A complete assortment

More information

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment Contents TS Implant System Cement retained restoration Screw retained restoration 06 Cement-retained bridges with the Solid abutment system (non- 72 Screw retained crown with the ComOcta Gold abutment

More information

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: 866-902-9272 781-328-3490. Fax: 866-903-9272 781-328-3400

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: 866-902-9272 781-328-3490. Fax: 866-903-9272 781-328-3400 Contact Us: Implant System Phone: 866-902-9272 781-328-3490 Fax: 866-903-9272 781-328-3400 Prosthetic Manual Mail: Keystone Dental, Inc. 144 Middlesex Turnpike Burlington, MA 01803 USA www.keystonedental.com

More information

prosthetic technique manual

prosthetic technique manual prosthetic technique manual TABLE OF CONTENTS Introduction 1 Treatment Planning 2-5 Restorative Options Implant-level Cement-retained Restorations Implant-level Screw-retained Restorations Abutment-level

More information

All-on-4 treatment concept with NobelSpeedy Groovy

All-on-4 treatment concept with NobelSpeedy Groovy All-on-4 treatment concept with NobelSpeedy Groovy Product overview Immediate Function for high patient satisfaction Immediately loaded fixed provisional prosthesis on the day of surgery. Immediate improvement

More information

NARROW DIAMETER implant

NARROW DIAMETER implant ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball

More information

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM PROSTHETIC PROCEDURE for HG IMPLANT SYSTEM HG Implant System Contents Cement retained restoration Rigid abutment When abutment reduction is unnecessary When abutment

More information

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system. www.straumann.com

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system. www.straumann.com PROSTHETICS Crown and bridge restorations with the synocta prosthetic system www.straumann.com Straumann is the exclusive industrial partner of the ITI (International Team for Implantology) in the areas

More information

Implant Parts. A Radford Heath Guide http://www.radfordheath.com 1

Implant Parts. A Radford Heath Guide http://www.radfordheath.com 1 Implant Parts A Radford Heath Guide http://www.radfordheath.com 1 Disclaimer The information given in this document has been provided in good faith for basic information purposes only and the information

More information

Multi-unit abutment bar overdenture

Multi-unit abutment bar overdenture This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit www.biohorizons.com/prostheticmanual.aspx Use this

More information

screw-retained crown using a PEEK temporary abutment

screw-retained crown using a PEEK temporary abutment screw-retained crown using a PEEK temporary abutment This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please visit

More information

One Abutment - One Time

One Abutment - One Time One Abutment - One Time A new treatment concept simple, innovative, easy to implement. Something so simple that does so much. What makes One Abutment - One Time a favorite among clinicians and patients

More information

screw-retained single crowns using custom-cast abutments

screw-retained single crowns using custom-cast abutments screw-retained single crowns using custom-cast abutments This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual, please

More information

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI Taking the Mystique out of Implant Dentistry Dr. Michael Weinberg B.Sc., DDS, FICOI What is Restorative Implant Dentistry? Restorative implant dentistry involves taking a few simple mechanical principles

More information

DESS. Screws. Tijuana Ventas: (664) 685 6294/95 hirambogarin@dabocorp.com. For all major implant systems!! www.dabocorp.com

DESS. Screws. Tijuana Ventas: (664) 685 6294/95 hirambogarin@dabocorp.com. For all major implant systems!! www.dabocorp.com Screws Screws for definitive use. Made from medical grade 5 ELI Titanium Integrity and soundness guaranteed by stress tests of up to 150% of their nominal torques. Their designs ensure a perfect fit with

More information

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM PROSTHETICS Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM IMPORTANT NOTES Disclaimer of liability The ITI dental implant is part of an overall concept and may only

More information

Regular C/X Prosthetics. Prosthetics

Regular C/X Prosthetics. Prosthetics Regular C/X Prosthetics /X C/ Prosthetics ANKYLOS C/X Prosthetics For more than 20 years, the ANKYLOS system developed by Prof. Dr. G.-H. Nentwig and Dr. Dipl.-Ing. Walter Moser with its TissueCare Connection

More information

Implant Bar Overdenture Utilizing Locator Attachments

Implant Bar Overdenture Utilizing Locator Attachments Utilizing Locator Attachments Step-by-Step Restorative Protocol Implant Bar Overdentures offer a removable implant solution for edentulous patients desiring a stable and esthetic prosthesis that improves

More information

Crown and Bridge Restorations. Straumann synocta Prosthetic System

Crown and Bridge Restorations. Straumann synocta Prosthetic System Crown and Bridge Restorations Straumann synocta Prosthetic System The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research and education. Contents

More information

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT Introduction A 58 year old male had been missing teeth #7=12 for approximately 28 years. During

More information

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT Straumann Variobase Abutment 1 The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research

More information

SCD Case Study. Treatment Considerations for Implant Rehabilitation

SCD Case Study. Treatment Considerations for Implant Rehabilitation SCD Case Study Treatment Considerations for Implant Rehabilitation Multiple surgical and restorative factors play a role in the treatment planning of implant restorations for the edentulous patient (Ali

More information

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

ATLANTIS abutments design guide CAD/CAM patient-specific abutments ATLANTIS abutments design guide CAD/CAM patient-specific abutments Contents Introduction 4 This manual helps you to explore all the benefits of ATLANTIS CAD/CAM patient-specific abutments. It gives you

More information

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection Sanjay Karunagaran, B.D.S., D.D.S., M.S.D., Gregory J. Paprocki, D.D.S., Russell Wicks, D.D.S., M.S., Sony Markose, B.D.S.,

More information

ball abutment overdenture: chairside pick-up using existing denture

ball abutment overdenture: chairside pick-up using existing denture ball abutment overdenture: chairside pick-up using existing denture This prosthetic technique module may contain references to the complete Prosthetic Manual (L02015). To download the full Prosthetic Manual,

More information

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments Clinical and Laboratory Procedures for Fixed Margin Implant Abutments Dr. Carl Drago DDS, MS, American Board of Prosthodontics Director, Dental Research BIOMET 3i, Adjunct Faculty Department of Prosthodontics,

More information

Implants in your Laboratory: Abutment Design

Implants in your Laboratory: Abutment Design 1/2 point CDT documented scientific credit. See Page 41. Implants in your Laboratory: Abutment Design By Leon Hermanides, CDT A patient s anatomical limitations have the greatest predictive value for successful

More information

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES Straumann Anatomic IPS e.max Abutment The ITI (International Team for Implantology) is academic partner of Institut Straumann in the areas of research

More information

Prosthodontist s Perspective

Prosthodontist s Perspective Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution - Non-Commercial - Share Alike 3.0 License. Copyright 2008, Dr. Jeff Shotwell. The following

More information

Standard Internal Hex

Standard Internal Hex Standard Internal Hex Touareg TM -OS Touareg TM -S Swell TM Touareg -S Touareg -OS Swell About ADIN Adin Dental Implant Systems Ltd., designs, manufactures and markets state of the art, technologically

More information

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation

More information

Encode Restorative System Procedure & Laboratory Manual

Encode Restorative System Procedure & Laboratory Manual Procedure & Laboratory Manual Encode Virtual Abutment Encode Abutment Blank Encode Abutment 1/2 Milled Encode Abutment Completed ENCODE RESTORATIVE SYSTEM Simply Impressive With the introduction of the

More information

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS Straumann Temporary Abutments, VITA CAD-Temp The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of

More information

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics Diagnosis Diagnosis Diagnosis Implantology Is a Prosthetically Driven Entity. Information Before Treatment is Diagnosis Information after Treatment

More information

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS Straumann Narrow Neck Straumann is industrial partner of the ITI (International Team for Implantology) in the areas of research, development and education. CONTENTS

More information

Contact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare.

Contact: Steve Hurson VP, R & D Nobel Biocare 22715 Savi Ranch Pkwy Yorba Linda, CA 92887 (714) 282-5072 steve.hurson@nobelbiocare. Use of CP Titanium and Titanium alloys for Dental Implants Steve Hurson, Nobel Biocare U.S.A. Yorba Linda CA Abstract Professor Per Ingvar Branemark of Sweden published his results on 15 years of research

More information

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16

More information

Restorative Manual Impression Transfer System

Restorative Manual Impression Transfer System Restorative Manual Impression Transfer System Indirect (closed-tray) transfer technique Implant-level indirect transfers for closed-tray, transfer impression technique Designed to transfer the soft tissue

More information

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

The LOCATOR concept. Simplicity and versatility for prosthesis fixation The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful

More information

About DENTSPLY Implants

About DENTSPLY Implants Product Catalog About DENTSPLY Implants Improving patient quality of life requires vision, commitment, creativity, and innovation. We are committed to a thorough scientific approach and clinical evidence

More information

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth. CHAPTER 10 RESTS AND DEFINITIONS A REST is any rigid part of an RPD framework which contacts a properly prepared surface of a tooth. A REST PREPARATION or REST SEAT is any portion of a tooth or restoration

More information

Dental Implant Restoration

Dental Implant Restoration Dental Implant Restoration Principles and Procedures Stuart H. Jacobs Brian C. O Connell London, Berlin, Chicago, Tokyo, Barcelona, Beijing, Istanbul, Milan, Moscow, New Delhi, Paris, Prague, São Paulo,

More information

More than a fixed rehabilitation.

More than a fixed rehabilitation. More than a fixed rehabilitation. A reason to smile. In combination with: Patient expectations drive dental treatments for fixed edentulous immediate restorations. Patients today have increasingly high

More information

How To Use A Cresco

How To Use A Cresco Cresco Prosthetic and laboratory procedures 2 Discover the freedom of precision When it comes to screw-retained implant bridges, Cresco is proving to be the preferred choice of both dentists and dental

More information

Clinical Perspectives

Clinical Perspectives Clinical Perspectives Inside This Issue: Accelerated Patient Rehabilitation With Advanced Technologies Case Presentation By: Pär-Olov Östman, DDS, PhD, MD Åsa Kärner, CDT Volume 8, Issue 2 Advanced Technologies

More information

Step-by-Step Virtual Implant Planning MIS Corporation. All Rights Reserved. MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed

More information

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. CONTENTS Product

More information

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS Straumann Temporary Abutments, VITA CAD-Temp The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of

More information

Navigator System For CT Guided Surgery Manual

Navigator System For CT Guided Surgery Manual Navigator System For CT Guided Surgery Manual Instructions For Use OSSEOTITE, OSSEOTITE XP, OSSEOTITE Certain, Certain PREVAIL, OSSEOTITE NT, Encode, IOL, Miniplant, Microminiplant, GingiHue, Gold-Tite,

More information

While the prosthetic rehabilitation of

While the prosthetic rehabilitation of Restoring Mandibular Single Teeth with the Inclusive Tooth Replacement Solution Go online for in-depth content by Bradley C. Bockhorst, DMD While the prosthetic rehabilitation of full-arch cases provides

More information

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit a perfect fit CROWN AND BRIDGE RESTORATIONS WITH THE CAMLOG IMPLANT SYSTEM Basic Information Planning of the Prosthetic Restoration Fabrication of the Plaster Model Temporary Restorations Esthomic Line

More information

Ridge Reconstruction for Implant Placement

Ridge Reconstruction for Implant Placement Volume 1, No. 5 July/August 2009 The Journal of Implant & Advanced Clinical Dentistry Ridge Reconstruction for Implant Placement 2 Hours of CE Credit Oral Implications of Cancer Chemotherapy Immediate

More information

Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh.

Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh. Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh., INDIA IMPLANT ABUTMENT An abutment is a component that is intermediate between

More information

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4. ITI Standard Implant Dental Implant System The ITI Dental Implant System was developed in Switzerland by the Institute Straumann and Dr. ndre Schroeder, President of the University ern. ITI implants are

More information

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT FIXTURE COMPONENTS 004 006 MS SA Implant - Narrow Ridge MS SA Implant - Denture 008 010 MS Implant - Provisional MS KIT MS SA Implant - Narrow Ridge MS SA Implant - Narrow Ridge Components 3 7 Impression

More information

TRI-CAM Implant System

TRI-CAM Implant System TRI-CAM Implant System infinite opportunities In Implantology For almost 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop and manufacture the highest quality,

More information

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL Osteo-Ti INTRODUCTION This handbook has been designed to give you a basic understanding of dental implants and related surgery procedures. As with all

More information

Full Crown Module: Learner Level 1

Full Crown Module: Learner Level 1 Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / 30 Extensions: Porcelain Fused to Metal (PFM) / 12 All Ceramic / 8 Learner Level 1 Mastery of Tooth Preparation Estimated Set Up Time: 30

More information

Simpl Implant Abutments with Atlantis CAD CAM Technology

Simpl Implant Abutments with Atlantis CAD CAM Technology Simpl Implant Abutments with Atlantis CAD CAM Technology Don t change your implant... change your abutment. See more patients in less time... and save money in the process! See how we ve made it Simpl.

More information

BASIC INFORMATION ON THE prosthetic procedures. Straumann Bone Level Implant Line

BASIC INFORMATION ON THE prosthetic procedures. Straumann Bone Level Implant Line BASIC INFORMATION ON THE prosthetic procedures Straumann Bone Level Implant Line Straumann is the industrial partner of the International Team for Implantology (ITI) in the areas of research, development

More information

ATLANTIS abutments as individual as your patients

ATLANTIS abutments as individual as your patients ATLANTIS abutments as individual as your patients ATLANTIS the freedom of unlimited possibilities Discover why ATLANTIS CAD/CAM abutments are the natural choice for patientspecific, cement-retained implant

More information

World leading in innovative restorative and esthetic dental solutions.

World leading in innovative restorative and esthetic dental solutions. World leading in innovative restorative and esthetic dental solutions. Individualized crowns, bridges, veneers and abutments Standardized implants and abutments TiUnite surface At a glance Nobel Biocare

More information

IMPLANT DENTISTRY EXAM BANK

IMPLANT DENTISTRY EXAM BANK IMPLANT DENTISTRY EXAM BANK 1. Define osseointegration. (4 points, 1/4 2. What are the critical components of an acceptable clinical trial? (10 points) 3. Compare the masticatory performance of individuals

More information

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration ROBERT SCHNEIDER, DDS, MS* ABSTRACT The prosthetic restoration of a

More information

education Although demographic factors and growing patient awareness of the benefits of dental implants

education Although demographic factors and growing patient awareness of the benefits of dental implants education Increasing implant dentistry in undergraduate education using new technology: A pilot project Hugo De Bruyn, MDS, MsC, PhD ± & Stefan Vandeweghe, DDS Although demographic factors and growing

More information

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation Smile Confidently With DIEM 2 Immediate Full Arch Rehabilitation Immediate Full Arch Rehabilitation * Edentulism and failing dentition continue to be major health challenges affecting millions of people

More information

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

THE LOCATOR OVERDENTURE IMPLANT SYSTEM. THE LOCATOR OVERDENTURE IMPLANT SYSTEM. FOUR DECADES OF ATTACHMENT KNOWLEDGE INCORPORATED INTO NARROW DIAMETER OVERDENTURE IMPLANTS. The LOCATOR Overdenture Implant System (LODI) is comprised of 2.4mm

More information

SURGICAL MANUAL. Step By Step Techniques

SURGICAL MANUAL. Step By Step Techniques SURGICAL MANUAL Step By Step Techniques TABLE OF CONTENTS PRE-SURGICAL 1 8 MEASUREMENT OF BONE.......................... 2 BONE CLASSIFICATION........................... 3 IMPLANT SIZE SELECTION.........................

More information

BICON DENTAL IMPLANTS

BICON DENTAL IMPLANTS BICON DENTAL IMPLANTS The Bicon Dental Implant System, since 1985, has offered discerning dentists the ability to provide secure implant restorations that look, feel, and function like natural teeth. With

More information

Renaissance of One-Piece Implants

Renaissance of One-Piece Implants 2 EDI Minimally invasive and patient-friendly treatment concepts using one-piece implants Renaissance of One-Piece Implants Hannes Thurm-Meyer, dentist, Bremen, Germany, Thomas Horn, master dental technician,

More information

Nobel Clinician - Quick Guide

Nobel Clinician - Quick Guide 1220 E. Birch St. #201 Brea, CA 92821 (800)750-5004 Haupt Dental Lab Inc. Nobel Clinician - Quick Guide Step #1 - Diagnostics Make impressions of both the upper and lower arches using custom trays. Care

More information

LOCATOR ROOT ATTACHMENT SYSTEM

LOCATOR ROOT ATTACHMENT SYSTEM TECHNIQUE MANUAL LOCATOR ROOT ATTACHMENT SYSTEM IMPORTANT: This document contains the most current instructions for use. Please, read and retain. DESCRIPTION: Universal hinge, resilient attachment for

More information

Implant Assisted Removable Prosthodontics

Implant Assisted Removable Prosthodontics Implant Assisted Removable Prosthodontics M. Nader Sharifi, D.D.S., M.S. Cincinnati Dental Society Cincinnati, OH Friday May 7, 2014 I. Course Synopsis A. Different Types of Overdentures B. Implants with

More information

CAD/CAM technology supporting successful implant therapy

CAD/CAM technology supporting successful implant therapy CAD/CAM technology supporting successful implant therapy Suheil M. Boutros, DDS, MS, Manuel Fricke, DT Modern implantology opens up new treatment options for individuals with only minimal or no remaining

More information

ADA Insurance Codes for Laboratory Procedures:

ADA Insurance Codes for Laboratory Procedures: ADA Insurance Codes for Laboratory Procedures: Inlay/Onlay Restorations D2510 Inlay - metallic - one surface D2520 Inlay - metallic - two surfaces D2530 Inlay - metallic - three or more surfaces D2542

More information

Milled Bar Overdentures-Protocol and Procedures

Milled Bar Overdentures-Protocol and Procedures Milled Bar Overdentures-Protocol and Procedures Dennis Urban, CDT When full implant dentures requiring a milled bar is prescribed, the proper protocol and procedure are of extreme importance. The proper

More information

Long-term success of osseointegrated implants

Long-term success of osseointegrated implants Against All Odds A No Bone Solution Long-term success of osseointegrated implants depends on the length of the implants used and the quality and quantity of bone surrounding these implants. As surgical

More information

Dental Implant Options in Atrophic Jaws

Dental Implant Options in Atrophic Jaws Dental Implant Options in Atrophic Jaws Orthopedic Application Jay B. Reznick, D.M.D., M.D. Diplomate, American Board of Oral and Maxillofacial Surgery Tarzana, CA Endopore Dental Implant System Screw-Type

More information

Accelerated Patient Rehabilitation

Accelerated Patient Rehabilitation Accelerated Patient Rehabilitation Providing The Tools Necessary For An Immediate Solution: NanoTite Implants QuickBridge Provisional Components Navigator System For CT Guided Surgery Initial Patient Presentation

More information

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants Technique Manual LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants Status of information: L8002-TM REV. F - DF4515 Rev. 000 09/2010 1 CLASSIFICATION Universal hinge, resilient attachment

More information

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options A New Beginning with Dental Implants A Guide to Understanding Your Treatment Options Why Should I Replace My Missing Teeth? Usually, when you lose a tooth, it is best for your oral health to have it replaced.

More information

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures by Timothy F. Kosinski, DDS, MAGD While oral function is the primary concern for most patients, the importance of esthetics

More information

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca Duration: 6 meses STEP 1: WAX-UP OF FOUR UPPER POSTERIOR TEETH with Dr. Ivan Ronald Huanca The objective of this course s step

More information

2016 Buy Up Dental Care Plan Procedure List

2016 Buy Up Dental Care Plan Procedure List * This is in addition to the embedded Preventive Plan (see procedure list at deltadentalco.com/kp_preventive. BASIC SERVICES Minor Restorative Services D2140 Amalgam 1 surface, primary or permanent D2150

More information

ERA. Attachment Systems. A SNAP to Use and Maintain

ERA. Attachment Systems. A SNAP to Use and Maintain ER ttachment ystems NP to Use and Maintain ER Partial Denture ttachments The female component is a plastic pattern which is incorporated as part of a crown wax-pattern and cast in a hard alloy. metal female

More information

Dental Updates. Excerpted Article e-mail: re777@comcast.net. Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Dental Updates. Excerpted Article e-mail: re777@comcast.net. Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS ¼ ½ ¾ µ mw/cm 2 Volume 17; 2007 Dental Updates "CUTTING EDGE INFORMATION FOR THE DENTAL PROFESSIONAL " 200 SEMINARS AND 30 JOURNALS REVIEWED YEARLY FOR THE LATEST, CUTTING EDGE INFORMATION Excerpted Article

More information

LOCATOR BAR ATTACHMENT SYSTEM

LOCATOR BAR ATTACHMENT SYSTEM TECHNIQUE MANUAL LOCATOR BAR ATTACHMENT SYSTEM IMPORTANT: This document contains the most current instructions for use. Please, read and retain. DESCRIPTION: Universal hinge, resilient attachment for bar

More information

The Attractive Glass Abutment System (ZX-27) HANDOUT

The Attractive Glass Abutment System (ZX-27) HANDOUT The Attractive Glass Abutment System () HANDOUT! " " # $ % $ # & ' ( ) FAQs New Solutions Pharmaceuticals Tel.: +971 6 7460661 Fax : +971 6 7460771 P.O.Box. 18161 Ajman - UAE e-mail : info@newsolutionsdl.com

More information

New features DWOS 3.2

New features DWOS 3.2 New features DWOS 3.2 Version 1.1 Septembre 13 th 2012 Summary This document describes how to use the new features and improvements of the release 3.2.0 of the Dental Wings Open Software (DWOS). Order

More information

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS IMPLANTS IN FOCUS PLANNING FOR IMPLANT RESTORATIONS Replacing a missing maxillary central incisor with a dental implant can be the most demanding restoration in dentistry, so it s important to consider

More information

Gl GinGival level implant

Gl GinGival level implant GL Gingival Level implant TABLE OF CONTENTS GL - Gingival Level implant Implant characteristics page 04 Dental implant page 05 Prosthetic components page 06 Ball attachment system page 08 Temporary peek

More information

Straumann Bone Level Tapered Implant Peer-to-peer communication

Straumann Bone Level Tapered Implant Peer-to-peer communication Straumann Bone Level Tapered Implant Peer-to-peer communication Clinical cases April, 2015 Clinical Cases Case No. Site 1 Single unit; Anterior Maxilla 2 Multi-unit; Anterior Maxilla Implant placement

More information

FABRICATING CUSTOM ABUTMENTS

FABRICATING CUSTOM ABUTMENTS FABRICATING CUSTOM ABUTMENTS LUC AND PATRICK RUTTEN How much should a Dental Technician know about the clinical aspects of implantology? The answer is clear: as much as possible. This is the distinction

More information

Abutment fracture in a bridge supported by natural teeth and implants

Abutment fracture in a bridge supported by natural teeth and implants Abutment fracture in a bridge supported by natural teeth and implants Authors_Dr Gregory-George Zafiropoulos, Dr Giorgio Deli & Dr Rainer Valentin, Germany/Italy _Introduction Implant treatment has evolved

More information

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí kéï=~ë=çñw= MRKOMNP páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí lééê~íáåö=fåëíêìåíáçåë båöäáëü=erpf Operating Instructions = Sirona Dental Systems GmbH Table of contents 1 Symbols used... 3 2 Product description...

More information

Choosing the right type of abutment

Choosing the right type of abutment 50 Producing custom implant abutments using CAD/CAM Choosing the right type of abutment S. KHALILOVA 1, F. KISTLER 2, S. ADLER 3, S. WEISS 3, S. KISTLER 2 AND J. NEUGEBAUER 2,4 Rapid developments in the

More information