Dynamic Behaviour of DC Motor-Based Photovoltaic Pumping Systems under Searching MPPT Algorithms

Similar documents
K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

Maximum Power Tracking for Photovoltaic Power Systems

Improved incremental conductance method for maximum power point tracking using cuk converter

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

A Stable DC Power Supply for Photovoltaic Systems

Solar Energy Conversion using MIAC. by Tharowat Mohamed Ali, May 2011

New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar

Hybrid Power System with A Two-Input Power Converter

A Design of DC/DC Converter of Photovoltaic Generation System for Streetcars

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Power Flow Control Using Bidirectional Dc/Dc Converter for Grid Connected Photovoltaic Power System

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Input and Output Capacitor Selection

THE CONTINUOUS growth of the global energy demand

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

Maximum power point tracking techniques for solar water pumping systems

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Simulation and Analysis of Perturb and Observe MPPT Algorithm for PV Array Using ĊUK Converter

An Isolated Multiport DC-DC Converter for Different Renewable Energy Sources

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

Student Pulse Academic Journal

Bringing Renewable Energy to the Electrical Engineering Undergraduate Education and Research at UPRM

Multi-port DC-DC Topology for Renewable Energy Systems using Soft Computing Techniques

A Photovoltaic Array Simulation Model for Matlab-Simulink GUI Environment

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Parametric variation analysis of CUK converter for constant voltage applications

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

Analog & Digital Electronics Course No: PH-218

Switch Mode Power Supply Topologies

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Implementation of the Movable Photovoltaic Array to Increase Output Power of the Solar Cells

Design and implementation of a modified DC- DC converter suitable for renewable energy application

Chapter 20 Quasi-Resonant Converters

Modeling and Control for Smart Grid Integration with MPPT of Solar/Wind Energy Conversion System S. Sathish Kumar 1, B.Swapna 2, Dr.C.

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

FREQUENCY CONTROLLED AC MOTOR DRIVE

Design of Solar Power Optimizer And Eliminating Leakage Current In Multi-Level Inverter For PV Systems

A bidirectional DC-DC converter for renewable energy systems

DC Motor control Reversing

Energy comparison of MPPT techniques for PV Systems

Application Note AN- 1095

Solar Mobile charging Solutions

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Implementation of High Step-Up Solar Power Optimizer for DC Micro Grid Application

Chapter 4. LLC Resonant Converter

98% Efficient Single-Stage AC/DC Converter Topologies

Design, Analysis, and Implementation of Solar Power Optimizer for DC Distribution System

Creating a Usable Power Supply from a Solar Panel

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Coordination Control of a Hybrid AC/DC Microgrid With Various Renewable Energy Sources

SPEED CONTROL OF INDUCTION MACHINE WITH REDUCTION IN TORQUE RIPPLE USING ROBUST SPACE-VECTOR MODULATION DTC SCHEME

The Calculation of G rms

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

See Horenstein 4.3 and 4.4

Capacitor Ripple Current Improvements

Line Reactors and AC Drives

Closed Loop PWM Control for Induction Motor Drive Using Dual Output Three Phase Inverter

Design of an Auxiliary Power Distribution Network for an Electric Vehicle

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

2. Permanent Magnet (De-) Magnetization 2.1 Methodology

Bi-directional Power System for Laptop Computers

Power Electronic Circuits

DC-DC Converter Basics

Analysis and Design of Multi Input Dc Dc Converter for Integrated Wind PV Cell Renewable Energy Generated System

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2014): 5.

SIMULATION AND ASSESSMENT OF SINGLE PHASE SEMI-Z-SOURCE INVERTER (S-ZSI)

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

MULTI-INPUT DC-DC CONVERTER FOR RENEWABLE ENERGY SOURCES

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Maximum power point tracking using a fuzzy logic control scheme

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Efficient Interconnect Design with Novel Repeater Insertion for Low Power Applications

Modified Cascaded Five Level Multilevel Inverter Using Hybrid Pulse Width Modulation

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

Frequency Response of Filters

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Stand-alone Photovoltaic System for a Cabin in Marsa-allam

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Power quality control strategy for grid-connected renewable energy sources using PV array and supercapacitor

Analog Optical Isolators VACTROLS

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Motor Fundamentals. DC Motor

Transcription:

Dynamic Behaviour of DC Motor-Based Photovoltaic Pumping Systems under Searching MPPT Algorithms M. A. Elgendy, B. Zahawi, D. J. Atkinson, and D. Giaouris School of Electrical, Electronic, and Computer Engineering - Newcastle University m.a.elgendy@ncl.ac.uk, bashar.zahawi@ncl.ac.uk, dave.atkinson@ncl.ac.uk, damian.giaouris@ncl.ac.uk Abstract- The behaviour of searching maximum power point tracking (MPPT) algorithms utilizing direct duty ratio perturbation control is shown to exhibit nonlinear phenomena, including slow scale bifurcations and chaos like behaviour, when applied to a dc photovoltaic () system. The performance characteristics of a dc photovoltaic water pumping system, in which the searching MPPT algorithm is applied at the frequency of the PWM signal of the converter, are examined. The nonlinear behaviour of the system is analyzed and the effects of different parameters on system performance are discussed. Key words: Pumping, MPPT, Buck Converter, Chaos. 1000 W/m 2, 60 C 800 W/m 2, 50 C 600 W/m 2, 40 C 400 W/m 2, 30 C 200 W/m 2, 20 C dc motor-pump set load line Operating Points Maximum Power Points I. INTRODUCTION The cost of conventional energy sources is continuously rising while the cost of systems is falling, increasing the potential for the use of energy in large scale schemes. One of the most important applications of energy is in water pumping. A pumping system comprises a array, a pump controller, a motor and a pump. The ac pumping system utilizing a multi-stage centrifugal pump and an induction motor is standard for subterranean water pumping, while the dc pumping system utilizing a single-stage centrifugal pump and a brushed dc motor, usually a permanent magnet motor, is most common for shallow water pumping. In the last decade, brushless dc motors have begun to replace brushed dc motors and induction motors for small scale pumping applications. A dc motor-pump set can be connected directly to the generator as is the case with most commercial dc pumping systems. In this case, the system operates at the intersection of the I V curve of the generator and the load-line (Fig. 1). This operating point may be far from the maximum power point of the generator. To achieve optimum matching between the generator and the motor-pump set, a pump controller, normally comprised of a simple dc-dc converter, is used. The duty ratio of the converter is controlled by a MPPT algorithm to maximize the power delivered to the load. The type of dc-dc converter is chosen in accordance with the voltage ratings of the motor and the array. A comparison between the performance of directly connected systems and that of systems using the most common MPPT algorithms has recently been presented [1]. In this paper, the dynamic behaviour of dc pumping systems utilizing searching MPPT algorithms is examined and analyzed showing these systems to exhibit chaos-like and quasi-periodic nonlinear characteristics under normal operating conditions. Fig. 1. Mismatch between dc motor-pump set and source II. SEARCHING MAXIMUM POWER POINT TRACKING ALGORITHMS Searching algorithms measure the array output current/power or the converter output current/power and utilize the measurement to determine whether to increase or decrease a control parameter. Conventionally, the array output voltage is utilised as the control parameter and used in conjunction with a PI controller to adjust the duty ratio of the converter [2-5]. In this case, the rate of MPP tracking is much lower than the PWM rate of the converter because the system has to wait for the effects of the perturbation. More recently, a faster implementation method has been suggested where the duty ratio is used directly as the control parameter [6]. Searching MPPT algorithms do not require previous knowledge of the generator characteristics and do not require measurement of solar intensity and cell temperature. However, they may be affected greatly by the chosen values for the dc link capacitance of the converter, the switching frequency, and the step size of changing the control variable [1]. The most common searching algorithms used for MPP tracking are the perturb and observe (P&O) algorithm and the incremental conductance (INC) algorithm. In the basic form of a P&O algorithm [7], the operating point of the generator is perturbed by increasing or decreasing the converter duty ratio by a small amount and measuring the generator output power (P ) before and after the perturbation. If the power increases, the controller continues to perturb the system in the same direction; otherwise the system is perturbed in the opposite direction. Fig. 2 shows that while the power is increasing, the direction of perturbation does not

change. The direction of perturbation, however, reverses every PWM cycle during periods in which the power is decreasing. The operation of the P&O algorithm is clearly related to output power variations regardless of the level of array voltage. During the period T = 2.076-2.0813 sec, the operating point of the system is located on the negative slope (dp / <0) of the array power-voltage curve (Fig. 3) hence, the correct direction of perturbation would be to increase the duty ratio of the converter thus reducing the array output voltage to move the operating point towards the MPP. When maximum power is reached at t = 2.0813 sec, the power begins to decrease, the operating point crosses the MPP and moves to the positive slope (dp / >0) part of the array power-voltage curve reversing the perturbation direction. Because of the slower response time of the system compared to the speed of the algorithm, the output power continues to decrease even after the direction of perturbation has been reversed, confusing the P&O algorithm which assumes that the power reduction is a result of the new perturbation. The algorithm will therefore reverse its perturbation direction forwards and backwards until the power begins to increase at t = 2.0864. The operating point of the system begins to move towards the MPP and crosses it again at t = 2.0911 to the negative slope of the array powervoltage curve. The algorithm is confused again then re-corrects itself at t = 2.0963 in the way described above. The INC algorithm [8] is based on the fact that the P-V curve of a generator has only one general maximum point (Fig. 3). At this point, the derivative of the power with respect to the voltage equals zero which means that the sum of the instantaneous conductance (I /V ) and the incremental conductance (di / ) equals zero (1). To the RHS and the LHS of the maximum power point, the sum of the instantaneous and incremental conductances is negative and positive, respectively (2, 3). At the MPP, To the LHS of the MPP, To the RHS of the MPP, di di di I = (1) V I > (2) V I < (3) V The incremental conductance MPPT algorithm compares the instantaneous conductance of a generator with its incremental conductance and decides whether to increase or to decrease the converter duty ratio accordingly. As shown in Fig. 4, the direction of perturbation changes every crossing of the maximum power point (i.e. when the sign of dp / changes). For instance, the duty ratio increases when the operating point is located on the negative slope of the array power-voltage curve (Areas a and c) and decreases when it locates on the positive slope part (Areas b and d). Fig. 2. Behaviour of P&O algorithm (1000W/m 2 & 25 C) dp > 0 dp Fig. 3. Power-voltage curve of a generator (1000 W/m 2 & 25 C) = 0 dp < 0 Fig. 4. Behaviour of INC algorithm (1000W/m 2 & 25 C) III. GENERAL DESCRIPTION OF THE SYSTEM In this paper, the nonlinear behaviour of both tracking algorithms is investigated using a dc pumping system comprised of 1020 Wp array, a step down dc-dc converter, and a permanent magnet dc motor loaded by a centrifugal pump (Fig. 5). The system is modelled and simulated utilizing individual models of each component derived from manufactures datasheets. System operation is simulated at constant solar intensity and cell temperature at 1000 W/m 2 and 25 C, respectively. The effects of the PWM frequency (f PWM ), the step size (ΔD), and the link capacitance (C L ) on system behaviour are studied. A comparison between the dynamic behaviour of the system under each MPPT algorithm is presented in the following section.

Fig. 5. DC photovoltaic pumping system block diagram IV. SIMULATION RESULTS A system operating with a searching MPPT algorithm has two types of transients; one originating from variations in solar irradiance/cell temperature and the other from the perturbation of the tracking algorithm. When the system is operating under steady-state solar irradiance and temperature conditions, it is still subjected to continuous step changes in duty ratio at the PWM rate. Because of its higher speed, the direct duty ratio perturbation approach adopted in this paper gives a faster transient response and a higher tracking efficiency compared to the reference voltage perturbation approach. This, however, means that the system is never allowed to reach a steady state due to the continued perturbation of the array voltage. In this section, attention is focused on the system s response to the perturbations resulting from the operation of the tracking algorithms. A. Perturb and Observe Algorithm The P&O algorithm continuously searches for the maximum power point causing the array voltage to fluctuate around the maximum power voltage (213 V) resulting in similar current and power fluctuations. As discussed above, the P&O algorithm can not distinguish between the power variations due to the perturbation and those result from the system dynamics. Hence, the direction of perturbation may change before crossing the maximum power point producing chaos-like array voltage and current waveforms and consequently similar motor current and torque waveforms (Fig. 6). The different waveforms of the system are always bounded by two levels hence the system is globally stable. Fig. 7 shows the array voltage-motor current phase plane of the system sampled at the PWM frequency with values of dc link capacitance (470 µf), PWM frequency (10 KHz) and step size (0.02%), chosen to give maximum power tracking efficiency [1]. The figure shows that array voltage is bounded between 208.4 V and 220 V while the motor current is bounded between 5.2 A and 6.25 A. Similarly, the duty ratio of the converter changes in a chaotic pattern between 83.3% and 86.8% (Fig. 8). Similar to the duty ratio waveform shown in Fig. 2, the horizontal lines in this figure represent the power decrease periods while other lines represent the power increase. The horizontal lines do not always start after crossing the MPP which means that the P&O algorithm may be confused any time depending on the system dynamics. Fig. 6: Array voltage and motor current waveforms; P&O algorithm Fig. 7: Array voltage - motor current phase portrait; P&O algorithm Fig. 8: Array voltage duty ratio phase portrait; P&O algorithm Fig. 9 shows the normalized frequency spectrum of the motor current. The motor current has a wide range of frequencies with maximum harmonic amplitude at 58 Hz. The low frequency harmonics of the motor current have very low amplitude compared to the dc value hence they have little effect on motor speed. However, if the current ripple increases, the amplitudes of these low frequency components increase causing motor vibration and noise. The peak-peak motor current ripple depends on the step size, the dc link capacitance and the PWM frequency.

Fig. 9: Normalized frequency spectrum of motor current; P&O algorithm A larger step size increases the algorithm speed compared to the speed of the system response resulting in larger ripple magnitude in the array voltage and consequently in the motor current. On the other hand, a smaller step size reduces the ripple magnitude but slows down the algorithm response to radiation and temperature changes. The bifurcation diagram of the system, taking the step size as the bifurcation parameter, is shown in Fig. 10. As shown, low step sizes do not allow the system to track the maximum power. Instead, the system runs at equilibrium points near its open circuit voltage. The tracking algorithm begins to work at about 0.01% step size and works on its highest efficiency between step size values between 0.015 and 0.05. As the step size increases, the tracking speed increases but also, the array voltage ripple increases resulting in low tracking efficiency and undesired motor operation. Occasionally, the system reaches equilibrium states where the power change with respect to the step size approaches zero. This often happens near the duty ratio limits (0% and 100%). In this case, the duty ratio fluctuates between three levels and the power increases and decreases repeatedly with a very small amount (Fig. 11). The MPPT is lost and the system either runs as directly connected or it runs near it open circuit voltage until the irradiance and/or the temperature changes. Fig. 11: Array output power and duty ratio waveforms at 0.18% step size; P&O algorithm The bifurcation diagram of the system taking the link capacitance as the bifurcation parameter is shown in Fig. 12. A low value of link capacitance may not be enough to store the generated power during the off-period of the converter switch forcing the system to run at equilibrium points near its open circuit voltage. At about 100 μf link capacitance, the P&O algorithm begins to work so that the magnitude of the array voltage ripple is not affected greatly by the link capacitance. Again, MPPT may be lost at some values of the link capacitance and the system runs at equilibrium points until the irradiance and/or the temperature changes. However in this case, these equilibrium points may be closer to the maximum power point of the system. The frequency of the converter PWM signal has a similar effect to that of the step size. Low values of PWM frequency reduce the algorithm speed resulting in slower response to radiation and temperature changes while higher PWM frequency values result in higher motor current ripple. The bifurcation diagram of the system taking the PWM frequency as the bifurcation parameter is shown in Fig. 13. At some values of the PWM frequency, MPP tracking can be lost and the system runs near its open circuit voltage. Fig. 10: Array voltage step size bifurcation diagram; P&O algorithm (µf) Fig. 12: Array voltage link capacitance bifurcation diagram; P&O algorithm

Fig. 13: Array voltage PWM frequency bifurcation diagram; P&O algorithm B. Incremental Conductance Algorithm When using the INC algorithm, the perturbation direction changes at every crossing of the maximum power point, causing the array voltage to oscillate around the maximum power point voltage resulting in the apparently quasi-periodic voltage and current waveforms shown in Fig. 14. The different waveforms of the system are also bounded by two levels hence the system is globally stable. Fig. 15 shows the array voltagemotor current phase plane of the system sampled at the PWM frequency with values of dc link capacitance = 470 µf, PWM frequency = 10 KHz and step size = 0.02%, chosen to maximise array output power. As shown, the array voltage is bounded between 208.8 V and 217 V and the motor current is bounded between 4.9 A and 6.5 A. Similarly, the converter duty ratio changes in a quasi-periodic pattern between 84.5% and 86.25% (Fig. 16). This figure also illustrates how the duty ratio perturbation direction is reversed every crossing of the maximum power point (213 V). The normalized frequency spectrum of the motor current is shown in Fig. 17. Unlike the P&O algorithm, the low frequency harmonics produced by INC algorithm are concentrated in a single tone at 58 Hz, which has higher amplitude than those obtained using the P&O algorithm. If the current ripple amplitude increases, the amplitudes of the low frequency components increase and may cause motor vibration and noise. The peak current ripple again depends on the values of step size, PWM frequency, and dc link capacitance. Fig. 15: Array voltage - motor current phase portrait; INC algorithm Fig. 16: Array voltage duty ratio phase portrait; P&O algorithm Fig. 17: Normalized frequency spectrum of motor current; INC algorithm Fig. 14: Array voltage and motor current waveforms; INC algorithm The bifurcation diagram of the system taking the step size as the bifurcation parameter is shown in Fig. 18. The INC algorithm begins to work at lower step size values and has smoother changes in array voltage compared to the P&O algorithm. It works on its highest efficiency at step size values of between 0.005 and 0.05. As the step size increases, the tracking speed increases but also, the array voltage ripple increases resulting in low tracking efficiency and undesired motor operation.

V. CONCLUSION An analysis of the dynamic performance of dc photovoltaic pumping systems operating with searching maximum power point tracking algorithms has been presented, showing the system to exhibit chaotic behaviour patterns when operating with P&O algorithms and a quasi-periodic pattern of behaviour when operating with INC algorithms. The frequency spectrum and the ripple amplitude of different current and voltage waveforms depend on the values of the PWM frequency of the MPPT converter, the value of dc link capacitance and the step size used in changing the duty ratio of the converter. Fig. 18: Array voltage step size bifurcation diagram; INC algorithm The bifurcation diagram of the system taking the link capacitance as the bifurcation parameter is shown in Fig. 19. The INC algorithm begins to work at lower link capacitance values and has smoother changes in array voltage compared to the P&O algorithm. Changes in PWM frequency have a similar effect to changes in step size. The bifurcation diagram of the system taking the PWM frequency as the bifurcation parameter is shown in Fig. 20. Compared with the P&O algorithm, the array voltage has smoother changes with the PWM frequency. Unlike the P&O algorithm, the INC works for the whole range of PWM frequencies and system waveforms are always of the same shape. ACKNOWLEDGEMENT The authors would like to thank Professor Soumitro Banerjee for his valuable comments and advice and would like to acknowledge the support received from the staff of the New and Renewable Energy Centre (NaREC). In addition, the first author would like to thank the Egyptian Government for sponsoring his studies. REFERENCES [1] M. A. Elgendy, B. Zahawi, and D. J. Atkinson., "Analysis of the Performance of DC Photovoltaic Pumping Systems with Maximum Power Point Tracking," presented at The 4th International Conference on Power Electronics, Machines and Drives 2008, York, UK, 2008. [2] D. P. Hohm and M. E. Ropp, "Comparative study of maximum power point tracking algorithms," Progress in Photovoltaics: Research and Applications, vol. 11, pp. 47-62, 2003. [3] V. Salas, E. Olias, A. Barrado, and A. Lazaro, "Review of the maximum power point tracking algorithms for stand-alone photovoltaic systems," Solar Energy Materials and Solar Cells, vol. 90, pp. 1555-1578, 2006. [4] N. Femia, G. Petrone, G. Spagnuolo, and M. Vitelli, "Optimization of perturb and observe maximum power point tracking method," IEEE Transactions on Power Electronics, vol. 20, pp. 963-973, 2005. (µf) Fig. 19: Array voltage link capacitance bifurcation diagram; INC algorithm [5] C. Hua, J. Lin, and C. Shen, "Implementation of a DSP-controlled photovoltaic system with peak power tracking," IEEE Transactions on Industrial Electronics, vol. 45, pp. 99-107, 1998. [6] E. Koutroulis, K. Kalaitzakis, and N. C. Voulgaris, "Development of a microcontroller-based, photovoltaic maximum power point tracking control system," IEEE Transactions on Power Electronics, vol. 16, pp. 46-54, 2001. [7] T. J. Liang, J. F. Chen, T. C. Mi, Y. C. Kuo, and C. A. Cheng, "Study and implementation of DSP-based photovoltaic energy conversion system," presented at Proceedings of the International Conference on Power Electronics and Drive Systems, 2001. [8] K. H. Hussein, I. Muta, T. Hoshino, and M. Osakada, "Maximum photovoltaic power tracking: an algorithm for rapidly changing atmospheric conditions," IEE Proceedings: Generation, Transmission and Distribution, vol. 142, pp. 59-64, 1995. Fig. 20: Array voltage PWM frequency bifurcation diagram; INC algorithm