LK100 Reverse Loop Module Art. No. 12100 Revised 7/03

Similar documents
GAUGEMASTER PRODIGY EXPRESS

Multi-Protocol decoder

Multi-Protocol decoder with Load regulation

Harford County Modular Model Railroad Fall 2014

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

The Hare TM REV J, 5/20/2011

INSTRUCTION MANUAL. FOR TECHNICAL ASSISTANCE: VERSION 3.2 ITEM #330

LocoNet, the Digitrax Difference

What ensures easy and fast wiring?

MasterControl. Central unit for digital control EasyControl. Manual. Art.-Nr

Series and Parallel Resistive Circuits

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Reversing starter circuit for single phase induction motors Updated 1 st September 2008

Gantry Crane 1:87. Description. Packing contents. Unpacking. Roof assembly

Servo Info and Centering

Snap-It. This is an accessory (switch machine) decoder

THE INPUT/OUTPUT SYSTEM. Key Points

User manual DinaSys DTC/DTS and DTC/DTZ

Operating Instructions

INSTALLATION GUIDE. FCC ID NOTICE

Hatton s MD4 Decoder. Thank you for purchasing Hatton s Decoders.

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

POINTS POSITION INDICATOR PPI4

Instructions for TF2 Digitrax Dual Function Decoder w/transponder. TF2 DCC Dual Function Decoder with Transponder

Quick Start Guide. For Bachmann DCC Sound-Equipped Locomotives. Featuring Tsunami DCC Sound Technology by SoundTraxx

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

e-ask electronic Access Security Keyless-entry

48 SERIES Relay interface modules 10 A

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

OPERATION MANUAL VALVE CHECKER G

49 Series - Relay interface modules A. Features

3BASIC RELAY INSTRUCTIONS

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Pluggable interface relays CR-P Pcb relays

Speed sensor MiniCoder GEL 247

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

WIRELESS STATUS MONITOR

AlarmSense 2-wire detection and alarm system. Product Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Digi-Motor Installation Guide

Configuration Variables For Digital Command Control, All Scales

EET272 Worksheet Week 9

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

"Sophisticated Model Railroad Electronics"

The Interaction of Contactors with PLCs

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads

ELECTRONIC POWER SYSTEMS

Features, Benefits, and Operation

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Complete Train Control. Run Your Trains, Not Your Track!

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

DC and DCC Operation of Atlas Gold Series HO Scale C424/C425 Diesel Locomotives

Single Channel Loop Detector

RP-6 IR-PRO RP-6. Operation & Installation Guide v1.0

SwitchPilot. User manual Third edition, October SwitchPilot SwitchPilot Extension SwitchPilot Servo P/N

Principles of Adjustable Frequency Drives

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Single Phase Soft Starter

User s Information Guide R1A

*The above steps do not program an address into the decoder/loco, it allows you to acquire an already known address.

Combi B Alarm box. Mounting instructions

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

GLOLAB Two Wire Stepper Motor Positioner

AP-1 Application Note on Remote Control of UltraVolt HVPS

TEK 1 Applications V TEKVOX, Inc San Antonio, TX 78232

Electrical Symbols and Line Diagrams

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Building the AMP Amplifier

Odyssey of the Mind Technology Fair. Simple Electronics

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

SYSTEM 45. C R H Electronics Design

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Number 1 in efficiency

Digital display DA 48

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

PUSH BUTTON START INSTALLATION MANUAL

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

OPERATING INSTRUCTIONS

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

User Manual CABLE TESTER CT100. Professional 6-in-1 Cable Tester

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

Contents. Document information

Physics 221 Experiment 5: Magnetic Fields

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

PAC1 Door Access Controller

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

A-178 Theremin Volt. Source

Points Position Indicator (PPI1) for Points Motors with Common Ground

DC Motor control Reversing

Load Cell Amplifier Module. Instruction Manual LCA

Transcription:

LK100 Automatic Reversing Unit 1 Developed to simplify the wiring of reversing loops on two-rail layouts using NMRA Digital Command Control by allowing you to operate your trains through a reversing section/loop without manually changing locomotive direction or track polarity. Maximum current draw in the reversing loop: 5 A Functions when the first wheel on either rail crosses the gap Designed for safe use on both common rail and two rail wired layouts For digital operation only. LK100 Reverse Loop Module Art. No. 12100 Revised 7/03

LK100 Automatic Reversing Unit 2 The problem with reversing loops: Every user of 2-rail DC knows the 'reversing loop' blues: Including a reversing loop in a 2-rail DC layout leads to a short where the reversing loop ties into the main line. Short circuit when locomotive passes Figure 1: Basic Reversing Loop The only way to prevent this short circuit is to insulate both sides of the track. A single two-rail gap is not enough, since a passing engine will short the rail through the electrical pick-up on both sides of the gap. Therefore, the track has to be gapped on both sides of the reversing loop. Once gapped, you still must ensure that the rails are not short circuited upon entry or exit of the reverse loop. Usually, the polarity is selected such that there is no short circuit upon entry into the loop. While the train is in the loop, the polarity is changed, so that there is no short circuit at the exit of the loop. On conventional layouts, this leads to a problem: Changing the polarity in the reversing loop will change the direction of the train, since the train's direction is dependent on the track polarity. Therefore, the direction also has to be changed at the power pack, so that the train keeps moving in the same direction on exit from the loop. In any case, the train has to be stopped while traversing the loop. On NMRA DCC operated layouts, the direction of the train is independent from the polarity on the track, therefore, the polarity of the reversing loop can be changed without stopping the train or changing it's direction. 2

LK100 Automatic Reversing Unit 3 Function of the LK100: The LK100 adjusts the polarity in the reversing section automatically for the passing train. This happens in a simple way: If the polarity is not correct when the train enters the reversing loop, the LK100 detects the short generated by the wheels of the locomotive and changes the polarity instantly. (see figure 2) This happens so fast, that it is undetectable during the movement of the train. The short is removed, and the train can enter the reversing loop. This short can be detected even if only a single wheel of the locomotive bridges the gap. When the train leaves the reversing loop at the other end, the ensuing short is detected by the LK100 and the polarity is adjusted accordingly. (see figure 2) IMPORTANT: The LK100 does not function for two-rail DC layouts powered by conventional 12 volt DC! Figure 2: Locomotive enters and exits the reversing loop section Installing the LK100: The wiring of the LK100 is very simple and shown in figure 3. The easiest source for the LK100 track inputs is the track near the reversing loop. Connect the "J" and "K" terminals on the input ("EIN") side of the LK100 to the track before the reversing loop. The "J" and "K" terminals on the output ("AUS") side of the LK100 is connected to the reversing loop track both rails insulated from the rest of the layout on both ends of the reversing loop).

LK100 Automatic Reversing Unit 4 Figure 3: Connecting the LK100 The reversing loop section (the section supplied by the output of the LK100) has to be as long as the longest train on the layout, independent from the actual track configuration used! Wiring Dogbones, Wyes, and Turntables: Using the LK100, Wyes, dogbones and turntables can also be wired without any problems. Please remember that the reversing loop (the section controlled by the LK100), shown gray in the figures, has to be as long as the longest train on your layout. The track is shown as a thick line in the figures. Figure 4: Using the LK100 for a dogbone layout. Figure 4 illustrates the wiring and layout for a dogbone. Only one end of the dogbone is shown, the other end has to be wired in the same fashion. 4

LK100 Automatic Reversing Unit 5 Figure 5 illustrates one example for wiring a layout with a wye. An alternative is to have the tail track of the wye controlled by the LK100. Figure 5: Using the LK100 in a wye configuration Figure 6 illustrates the wiring for a turntable. Rotating the turntable by 180 can lead to a short at the turntable tracks. To prevent this, the turntable can be wired through an LK100. The LK100 will promptly reverse the polarity, removing the short on entry and exit to the turntable. Figure 6: Using the LK100 to supply track voltage to a turntable. On a conventional layout, only the track lined up with the turntable is supplied with track voltage. Using Digital Command Control, it is possible to activate lights and smoke generators on locomotives parked in the service area. To use these features, all tracks need to be powered.

LK100 Automatic Reversing Unit 6 The line-up tracks for the turntable pit are often sold as accessories for the turntable and are wired to the turntable track. In this case, insulate both rails on all approaching tracks and supply the track voltage for the turntable from the LK100. The approach and storage tracks can then be wired directly to the DCC track power. Using an Occupancy detector in the Reversing Loop: If you want to use an occupancy detector LB100 within the reversing loop section, connect the LB100 between the output of the LK100 and the track. Figure 7 shows the wiring to the right detector on the LB100. You can also use the left detector on the LB100. Figure 7: Connecting the LB100 to the LK100 Using a conventional locomotive on the DIGITAL layout that uses an LK100: When a conventional non-decoder equipped locomotive is used in conjunction with a DIGITAL system, DC voltage is added to the DCC track bi-polar track signal. Although the locomotive can be controlled by the DCC command control system, its direction still depends on the polarity of the DC track voltage. If you want to run a conventional locomotive through a reversing loop controlled by an LK100, you should wire the reversing section as shown in Figure 8. 6

LK100 Automatic Reversing Unit 7 Figure 8: Using conventional locomotives with the LK100 Insert a reversing toggle switch (DPDT) in between the LK100 and the reversing loop. (see figure 8) This toggle switch allows you to manually change the polarity of the reversing loop. The sequence for a trip through the reversing loop is as follows: 1. The locomotive enters the reversing loop, if necessary, the LK100 adjusts the polarity of the reversing section. Since the polarity does not change for the locomotive, its direction will stay the same. 2. The train powered by the conventional locomotive is stopped once it is completely inside the reversing loop. 3. Now, change the polarity on the track using the toggle switch, and change the direction on the Hand Held. When the locomotive is started up again, it will move in the same direction as before, and it can leave the reversing loop without creating a short. Setting the sensitivity of the LK100: Apart from the terminals "J" and "K" for the input and output, there is a potentiometer on the side of the unit that is used to adjust the sensitivity of the LK100. The sensitivity of the LK100 has a factory setting that is mid way in the range. If the setting is too high (the pot turned towards the EIN side of the LK100) then the LK100 will be unable to detect the short and thus will not automatically reverse. If the setting is too low, (the pot turned towards the AUS side of the LK100) the

LK100 Automatic Reversing Unit 8 LK100 will tend to chatter, because the locomotive load is triggering the LK100 automatic reversing relays. The adjustment needs to be checked for both low current locomotive and high current trains. Figure 9: Setting the sensitivity of the LK100. Note the Power Station and wiring much be sized so that sufficient power is available in the reversing section in order that high loads present in your largest train do not cause a power brownout or an overload condition. Hüttenbergstraße 29 35398 Gießen, Germany Hotline: 06403 900 133 Fax: 06403 900155 info@digital-plus.de http://www.lenz.com http://www.digital-plus.de Lenz Agency of North America PO Box 143 Chelmsford, MA 01824 ph: 978 250 1494 fax: 978 455 LENZ support@lenz.com This equipment complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Please save this manual for future reference! 2003 Lenz GmbH, All Rights Reserved 8