MSS Sensor with Quickon Connector 171V62AQ

Similar documents
HARAX circular connector

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Cable Plug acc. to DIN EN , Form A

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Flexible and safe solutions, for decades. Cables for alarmand safety systems

Inductive Proximity Sensors

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HARTING Ethernet Cabling 8-poles Overview

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Operating Instructions

Conductive Level Switch FK 2 Technical Data:

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

ADACSNET USB Control Module

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Modular I/O System Analog and Digital Interface Modules

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Addendum to the Operating Instructions

KNX R. Rain Sensor. Installation and Adjustment

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Charge Regulator SCR 12 Marine

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

400 Series - Mini USB Buccaneer

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141

ROLINE THE Difference

HMI display Installation Guide

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Digital input modules

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

08. SEK IDC CONNECTORS

Cable Testing with the Huntron Tracker Model 30 and Scanners

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Standard Buccaneer - USB

Contact expansion modules

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Electronic Pressure Switch EDS 300

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Combi B Alarm box. Mounting instructions

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Product and functional description

Now Available in Black Zinc Nickel

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Technical Note Series

MechoNet TM Network Interface (MNI) Specification Submittal

KNX Interface. User Manual PM00A00IRI

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Current Monitoring Kit QUICK START GUIDE

SOURIAU s discrete wire sealing

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

FIREDEX Conventional Fire Panels

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

NELSON HEAT TRACING SYSTEMS

Color Mark Sensor with Red or Green LED E3S-VS

Safety Relays ESM/ESM-F

Current Monitoring Kit

How To Read A Pipe From A Sensor

Contents. Safety Warnings... 1

Hand-held thermometer Model CTH7000

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

PNOZsigma - Base units

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Mini USB and USB 2.0-IP67 Connector System

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

FASTON Terminals and Connectors

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Explosion proof enclosures

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

LIEBERT VNSA Installation Sheet

PCS0100en Persy Control Services B.V. Netherlands

Test equipment for temperature and its reduction

BNI EIP Z009 IP67 Module, Unmanaged Switch

Technical Data. Dimensions

MOUNTING AND OPERATING INSTRUCTIONS

Cat7/Class F New Installation Concept New infrastructure. Handbook

Product Information. HMC 6 Hybrid Motor Cable

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Subminiature Load Cell Model 8417

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

FAQ s on Siemens Magmeters

Transcription:

Product Information MSS Sensor with Quickon Connector 171V62AQ Contents: 1. Specification... 2 2. Product description... 3 3. General Information... 4 4. Application... 4 5. Product Advantage of the MSS- Sensors with Quickon 171V62AQ... 4 6. Availability... 4 7. Connection example... 5 Produktinformation MSS-Sensor mit Quickon Anschluss_e.doc - 1 -

1. Specification Protection class : IP67 (IEC529) Temerature range : -25...+75 C Current limiting resistor: 22 Ohm Material housing: PBT black Operating magnet: 30420000 Air gaps for reliable switching function at 20 C: switch on: max. 4 mm switch off: min. 16 mm minimum air gap: 0,5 mm For other suitable magnets, please consult the factory We reserve the right to change the specification. Circuit shown without power applied. Sensor shown not operated. Produktinformation MSS-Sensor mit Quickon Anschluss_e.doc - 2 -

2. Product description Principle function of the MSS- Sensors 171V62AQ New in the elobau machine safety product group is the sensor 171V62AQ. This is an M30 sensor in PBT material with a 2 normally open contact system and a Quickon connector. The seal on this Quickon connector plug is modified by elobau so that 2 cables can be inserted, enabling these sensors to be daisy- chained (similar to a bus- system). Several sensors can be interconnected (see connection example in section 7). The Quickon plug has the big advantage that you no longer need a defined cable length or a mating connector. On these Quickon connectors the individual wires are inserted directly into the clamp contacts (direct at the sensor) without the need to strip the insulation. By closing the connector cover the wires are fixed into the clamp contacts. Only the cable needs cutting to the prescribed length. This sensor you can operate with all elobau MSS central control units which have a 2 normally open contact system. You can reach up to category 4 according to the machine safety standard EN 954-1depending on the central control unit specified. This new sensor can be operated with the following elobau MSS central control units. The numbers of sensors per sensor input is dependent of the cable length and the cross section of the wire. The lower numbers refer to a maximum- cable length of approx. 500m with a cross section of 0,4mm² per wire: 471M41H31 CAT. 4 max. 25 sensors connected per sensor input 462M51H11 CAT. 4 max. 25 sensors connected per sensor input 462M41H31 CAT. 4 max. 25 sensors connected per sensor input 462M51H21 CAT. 4 max. 25 sensors connected per sensor input 462M41H34 CAT. 4 max. 25 sensors connected per sensor input 462151H1 CAT. 4 max. 3 sensors connected per sensor input 462141H1 CAT. 4 max. 3 sensors connected per sensor input 462151E1 CAT. 3 max. 3 sensors connected per sensor input 462141E1 CAT. 3 max. 3 sensors connected per sensor input Produktinformation MSS-Sensor mit Quickon Anschluss_e.doc - 3 -

3. General Information The MSS- sensor 171V62AQ and a 2 normally open contact system central control unit can reach up to category 4 according to the machine safety standard EN 954-11 (in depending on the central control- unit specified). Ensure that all applicable European directives and national statutory requirements/directives are followed. The product must be used in the original state without any unauthorised changes or modifications. 4. Application The equipment is only to be used for the protection against safety hazards depending upon the safety assessment of individual machines. Potential customers include all general mechanical and electrical engineering industries. 5. Product Advantage of the MSS- Sensors with Quickon 171V62AQ Fulfils the requirements of EN 954-1 / Category 4 (depending on the central control- unit specified) High protection class (IP67) Simplified wiring Installation only requires a non shielded 2-wire cable between the sensors. Economical solution 6. Availability Q I / 2005 (provisional) Produktinformation MSS-Sensor mit Quickon Anschluss_e.doc - 4 -

7. Connection example Produktinformation MSS-Sensor mit Quickon Anschluss_e.doc - 5 -