ARCHITECTURAL SPECIFICATIONS RHINO ADO 7000

Similar documents
SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Automatic Door Selection Guide

Automatic Door Openers and ADA Devices Rev. 0 Bid # Scope of Work

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

CLEAR-DIVISIONS CENTERFOLD

City of San Diego, CWP Guidelines

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

CLEAR-DIVISIONS VARIOFOLD

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Phoenix-3W Series One-Way Security Revolving Doors

SECTION GUARDA SECURITY WINDOW SCREENS

CLEAR-DIVISIONS APERTO

SECTION 6. Glass Storefront Doors:

Installation Manual Version 7.3 IMPORTANT:

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION STANDING SEAM METAL ROOFING

SECTION 1 GENERAL REQUIREMENTS

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

AUTOMATIC SWINGING DOOR

DESIGN CLARIFICATION (DC)

MODEL HSR-007 Direct Drive Rolling Steel

Automatic Swinging Door Systems

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

280+ Mortise Mounted Series Shear Locks Special Application Solution

SECTION AUTOMATIC SLIDING DOOR SYSTEMS. A. Automatic sliding doors with operator and motion/presence sensor control device.

AD425S Automatic door operator

AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS. Exclusively by:

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

AUTOMATIC SWINGING DOOR

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

ADDENDUM #1(BID PACKAGE # 3)

Roped Hydraulic Residential Elevator Specifications

Exhibit C Design Review Guidelines

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

AUTOMATIC SLIDING DOOR

TS93 EMR T/PT/TDE. Surface applied door closer

SECTION SERIES 1500 VINYL PATIO DOORS

SECTION HEAT PUMPS

SECTION METAL WALL PANELS

Architectural Specifications* MODEL HDE

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

Vinyl Patio Door Systems

EMF/EMR. Holder/Release Devices with Integral Door Closers

2. Division 05 Structural Steel Framing for steel framework requirements

Machine Safety Switch: SI-LM40 Series Limit Switch Style

WHEN IS A PERMIT REQUIRED?

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Water Leak Detection System

Floor-Concealed Door Closers DORMA BTS80

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Vehicle Restraint Installation Manual

P.A.L. S SPECIFICATIONS

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

3-Part Specification Railing Cable Systems

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

GenStore Archive Cabinet

Operation and Installation Manual

SECTION PREFORMED METAL STANDING SEAM ROOFING

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Window Installation Instructions

V1504 Vertical Platform Lift OWNER S MANUAL

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Machine Safety Switches

Contractors Guide Central Inverter System Installation

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

AUTOMATIC SWINGING DOOR

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

A. Shop Drawing submittals shall include, but not be limited to, the following:

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

WE-350 Series ¼ Turn Electric Actuator

Call for Availability

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

9300BC SERIES Light Commercial Door Closer

Sierra Pacific Windows

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Decorative Lever Designs

7200 series Electromechanical Closer/Holder

RACO Interior OfficeFronts. SolutionsII Typical Details. SolutionsII

Walking and Working Surface Checklist:

THIRD LAGUNA HILLS MUTUAL

Approved Document Q: Security

Transcription:

ARCHITECTURAL SPECIFICATIONS RHINO ADO 7000 LOW-ENERGY ELECTRIC SWING DOOR OPERATOR PART I - GENERAL 1.01 SUMMARY A. SECTION INCLUDES: Access Automation s low energy swing door operator. 1.02 REFERENCES A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) B. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D. THE ALUMINUM ASSOCIATION (AA) 1.03 SYSTEM DESCRIPTION Provide an automatic swing door operator which has been manufactured, fabricated and installed to maintain performance criteria stated by manufacturer without defects, damage or failure. 1.04 SUBMITTALS A. PRODUCT DATA: Submit manufacturer's product data and standard details 1.05 QUALITY ASSURANCE A. INSTALLERS QUALIFICATIONS: Installer experienced (as determined by contractor) to perform work of this section who has specialized in the installation of work similar to that required for this project and who is acceptable to product manufacturer. B. MANUFACTURERS QUALIFICATIONS: Manufacturer capable of providing field service representation during installation, approving acceptable installer and approving application method. 1.06 WARRANTY Units to be warranted against defect in material and workmanship for a period of one year from the date of installation.

PART ll - PRODUCTS 2.01 MANUFACTURER Automatic swing door operator(s) furnished and installed shall be of type(s) and size(s) specified and as indicated on plans and door schedule. 2.02 EQUIPMENT A. MANUFACTURED DOOR UNITS: 1. Style A700: Surface Applied Operator with Connecting Arms: The operator header shall be mounted to the surface of the existing door frame or wall. Connecting hardware shall be a double arm arrangement that can either push the door or pull the door open to suit the job condition. When the operator mounting is on the pull side and adjacent wall is within 4" (101.6 mm) of the door frame, specify a parallel arm. B. OPERATOR: The Electric Operating Mechanism shall be Style A700 Swing E-Z. The operator shall be shock mounted and concealed in an extruded aluminum 4" x 6" (102 mm x 152.4 mm) side access header extending the full width of door or a minimum 22" (558.8 mm) in length. The operator shall be readily convertible to any hand required. Opening force shall be accomplished by a 1/15 HP D.C. permanent magnet motor working through reduction gears to the output shaft. Closing force shall be supplied by a field replaceable spring. When the door is in the closing mode or fully closed, motor voltage shall not be required and will be off. The door can be manually operated with power on or off without damage to the operator. The master control unit shall incorporate an adjustable time delay of 1 to 99 seconds (ANSI A156.19 requirement is 5 second minimum time delay). It shall provide infinite adjustment to opening and back check speeds including adjusting the opening force without affecting the opening speed. The master control unit shall provide for immediate reversal of door motion without undue strain on the drive train by supplying stepped voltage to the motor. The door shall reverse when closing if an object stops the door. A locked door motor protection circuit will be supplied that will limit current to the motor if it is applied when the door is inadvertently locked or otherwise prevented from opening. C. OPERATION: Automatic and/or Manual: 1. Automatic: Pushbutton switch actuates door open; door closes after time delay expires. Operator to include the following variable adjustments so as to comply with ANSI Standard A156.19: Opening speed - 4 to 6 seconds; Closing speed - 4 to 6 seconds. Opening and closing force, measured 1" (25.4 mm) out from the lock stile of the door, not to exceed 15 pounds (67 N) of force to stop the door when operating in either direction.

2. Manual: Push-To-Open: Manually pushing door activates automatic opening cycle; door closes after time delay expires. Time delay for manual push-to-open operation to be independetly adjustable from 1-99 seconds. 2.03 RELATED EQUIPMENT A. ACTIVATING DEVICE: Shall be marked Press to Open and located on each side of the opening as per ANSI Safety Standard A117. 1. Option: Push plate: 4-1/2 Diameter (114.3 mm) round, stainless steel switch. 2.04 RELATED WORK REQUIREMENTS A. ELECTRICAL: 120 VAC, 60 cycle, 1 phase, 15 amp. Two low-voltage wires shall be furnished to connect push button/plate switch to the operator. 2.5 MATERIALS, FINISHES AND FABRICATION A. EXTRUDED ALUMINUM: ASTM B221, 6063-T5 alloy and temper, anodized: 1. Structural Header Sections: Minimum 1/8" (3 mm) thickness; capable of self-support of transom glass above. B. FINISHES (for all exposed aluminum surfaces): 1. 204-R1 Clear: Arch. Class ll Clear Anodized Coating, AA-MI2C22A31. 2. 313-R1 Dark Bronze: Arch. Class ll Anodized Coating, AA-MI2C22A32. 3. Special Paint Coating: Color as selected. C. OPERATOR CONSTRUCTION: Electromechanical. PART III - EXECUTION 3.01 EXAMINATION Site Verification of Conditions: Installer must verify that base conditions previously installed under other sections are acceptable for product installation according to with manufacturer's instructions. Notify the Contractor in writing of conditions detrimental to the proper and timely completion of work. Do not start work until all negative conditions are corrected in a manner acceptable to the installer and manufacturer. 3.02 INSTALLATION A. GENERAL: Install door units plumb, level and true to line with manufacturer's prescribed tolerances. Provide support and anchor in place. B. DISSIMILAR MATERIALS: Comply with AAMA 101, Appendix Dissimilar Materials ls separating aluminum materials and other corrodible surfaces from sources of corrosion or electrolytic action contact points.

C. ELECTRICAL: General or electrical contractor to install all wiring to operator on a separate circuit breaker routed into header. 3.03 CLEANING, ADJUSTMENT AND PROTECTION A. CLEANING: After installation, installer to take following steps: 1. Remove temporary coverings and protection of adjacent work areas. 2. Remove construction debris from construction site and legally dispose of debris. 3. Repair or replace damaged installed products. 4. Clean product surfaces and lubricate operating equipment for optimum condition and safety. B. ADJUSTMENT: Installer to adjust operator and controls for optimum condition and safety. C. ADVISE CONTRACTOR: of precautions required through the remainder of the construction period, to ensure that doors will be without damage or deterioration (other than normal weathering) at the time of acceptance. RHINO ADO 7000 Power Consumption The measured currents and power consumptions for the RHINO ADO 7000 operator are as follows: -Idle, door closed: 0.066 amperes, 8 watts -Opening, operator only (no door attached), peak measurement: 0.46 amperes, 56 watts -Holding open: 0.265 amperes, 32 watts The opening power will be somewhat higher with a door attached to the operator. A conservative estimate would be a factor of roughly two times the given figure (0.82 amperes or 112 watts) for any reasonable door weight (up to 100-125 pounds). The control has a 3.15 ampere fuse, so in no case will the prolonged current draw be more than this figure, as the fuse would blow. Another question which seems to be asked frequently regards cost of operation. It is estimated that the cost of operation is well below $0.01 per door cycle. It was also determined that if the door is held open all day long, 24 hours a day, the total cost per month is $2.84. The dollar figures given are based on energy cost of $0.12 per kilowatt hour.

367 Bering Ave. Toronto, Ontario, M8Z 3B1 Toll Free: 1-866-407-9325 www.rhinoteksolutions.com ARCHITECTURAL DETAILS POWER SWING DOOR OPERATORS RHINO ADO 7000 Series Surface Applied Single & Pair with Inswing or Outswing Arm 2015 Standard Packages Single Units Types: LH, RH, LHR, RHR Door Width 3'-0" (914) 3'-6" (1067) 3'-3" (991) 3'-9" (1143) Pair Units Types: LH-RH, LHR-RHR Door Pair Width 5'-0" (1524) 6'-0" (1829)6'-3" (1905) 7'-0" (2133)7'-3" (2210) 5'-3" (1600) Door Width 1 Power Supply Anodized Finish: Clear or Dark Bronze Installation and Operation Swing door header is surface mounted onto frame and connecting arm assembly is mounted to face of door panel. Frame and door panel to be provided by others. Electrical: Provide 120VAC, 60cycle, singlephase, 15 amp service (in conduit) to each swing door unit on a dedicated 20 amp circuit breaker routed into header. Maximum current draw is 3.15 amps. For 1-way traffic: Unit to be actuated by Sensor System For 2-way traffic, Low Energy: Unit to be actuated by push button or push plate Outswing Outswing 4 5/8" (102) Exterior Door panel and frame byothers Rhino ADO 7000 Electric Operator Access Panel 6" (152) Single Units Floor Plans with Elevations LHR & RHR shown. LH & RH are Inswing Door Pair Width Power Supply 1 5/8" (41) 3/4"(19) Outswing Power Arm Mounting Foot Connecting Arm Assembly Vertical Section 1 2 4 5/8" (102) Exterior 3/4"(19) Rhino ADO 7000 Electric Operator Access Panel 6" (152) Inswing Power Arm Inswing Door panel and frame by others Connecting Arm Assembly Mounting Foot Vertical Section 2 Pair Unit Floor Plan with Elevation LH-RH shown. LHR-RHR is Outswing RHINOTEK reserves the right to alter its product specifications without notice. Dimensions given in inches followed by millimeters in parenthesis.