SECTION 08810 GLASS AND GLAZING

Similar documents
Spandrel Glass Types and Recommendations

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

City of San Diego, CWP Guidelines

Garden Windows Builders Vinyl

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

SECTION STANDING SEAM METAL ROOFING

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

FIRE RATED GLAZING System Guide

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

SECTION GUARDA SECURITY WINDOW SCREENS

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

Pilkington Reflite Handling and Processing Guidelines Solar Control

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Quality Windows And Doors. Great Service. Exceptional Value.

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

MANCHESTER SERIES(SGD-R35) SLIDING GLASS DOOR 5 5/8 FRAME DEPTH

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

PART 1 GENERAL 1.1 SECTION INCLUDES

Glass Technical Document

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

SCHOTT PYRANOVA Planline System

Fire-Rated Glass and Glazing START

Window Installation Instructions

Section EXTERIOR STONE VENEER Full Mortar

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Preformed Metal Roofing and Siding

Building Code Clarifications - 7. Fire Resistance

SECTION METAL WALL PANELS

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

SECTION SERIES 1500 VINYL PATIO DOORS

Technical Data Honeycomb Door Leaf

Stiles. Basic Glass Guide. Steel Door + Window Systems CONTENTS

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours

How To Test For An Architectural Test

Unbeatable energy efficient glass curtain wall system

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Specifications for Programs: 737, 747, 757, 767, 777, 787

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Basement Window Installation Guide Hopper and Sliding

PART 1 PROJECT DESCRIPTION 1.01 GENERAL INFORMATION

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection.

Assessing Curtain Walls

FIRESTOPPING & SMOKE SEALS

GreenGuard Housewrap Installation Guide

Tundra Series Windows January 2016

A Complete Solution CREATING WALLS THAT DEFINE SPACE

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Pyroguard Wired Glass

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

glass & Glazing Products

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

SALES (800) FAX

CLEAR-DIVISIONS CENTERFOLD

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Pintura is a color coated glass product manufactured. by Pulp Studio, Inc, and is ideally suited for commercial

Handling, Inspecting, Fabricating & Glazing Pilkington Solar-E on Tinted Glass

Fiberglas, Exterior Wall Thermal Insulation

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Triarch Products Over Various Interior Substrates

Thermal Breakage Prediction

SECTION [ ] [08973] GLASS CANOPIES

vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and

CHAPTER 24 GLASS AND GLAZING

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

RAM Industries 8600 Commerce Park Dr Houston, TX Tel: Fax:

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

Sun Windows General Information Sun New Construction Window Installation Instructions

Quality Windows And Doors. Great Service. Exceptional Value.

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

ALUMINUM Guide Spec: Standard Aluminum Windows & Doors

Impact-Resistant Windows and Sliding Glass Doors

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

A. Work on this project shall consist of, but is not limited to, the following:

GARDEN WINDOW GLAZING AND DE-GLAZING INSTRUCTIONS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Optimum Windows Reliant Installation Manual

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Tuscany Series Vinyl Replacement Windows 3-Part Specification

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Section Aluminum Windows (4600 Series Specifications)

Important Information for Installer & Homeowner

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Transcription:

SECTION 08810 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Glass and Glazing as shown and detailed on the Drawings and specified herein. 1.02 QUALITY ASSURANCE A. References: 1.03 SUBMITTALS 1. American National Standards Institute (ANSI): a. ANSI/ASTM E330: Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. b. ANSI Z97.1: Safety Performance Specifications and Methods of Test for Safety Glazing Used in Buildings. 2. Flat Glass Marketing Association (FGMA): Glazing and Sealant Manuals. 3. Laminators Safety Glass Association (LSGA): Standards Manual. 4. Sealed Insulated Glass Manufacturers Association (SIGMA): Standards. A. Shop Drawings: Submit list of materials proposed for use; identify each glazing condition. B. Samples: Manufacturer's standard color range. C. Product Data: None required for specified products; required for alternate products. 1.04 PRODUCT HANDLING A. Delivery: Deliver with manufacturer's labels intact; do not remove until completion of final inspection. 1.05 SITE CONDITIONS A. Environmental Requirements: Glaze in dry conditions; minimum temperature 40ºF during and 48 hours after installation of glazing compounds. B. Protection: Protect glass from damage until occupancy of building; replace glass damaged or broken before final acceptance. 08810-1

1.06 MAINTENANCE A. Guarantee: PART II - PRODUCTS 2.01 MATERIALS 1. General: Provide in required form for stated period from date of final acceptance by Owner. 2. Float Glass: Per requirements of ASTM C1036 and ASTM C1048. 3. Reflective Glass: Reflective coating; ten (10) years. 4. Transparent (Two-way) Mirrors: Reflective coating; ten (10) years. 5. Insulating Glass: Five (5) years. A. Manufacture: 1. PPG Industries, Inc. Glass Group, unless otherwise indicated, Southwall Technologies, or equal. 2. Tempered Glass and Safety Glazing: Comply with United States Consumer Product Safety Commission's "Safety Standards for Owner's Architectural Glazing Materials" (16 CFR part 1201) category I or II, as applicable; UBC Standard 54-2 and Section 5406 (c) of CBC. B. Flat Glass: 1. General: Size and thickness as shown. 2. Float Glass: ASTM C1036, Type 1 transparent flat, Class 1 clear, quality q3 glazing select. 3. Tempered Glass: ASTM C1048, fully tempered with horizontal tempering. 4. Low E Glass: "Sungate 100" clear [gray] [bronze] [Solagreen] [Azurlite] [Solex]; thickness as shown, or equal, no known equal. 5. Wire Glass: a. "Baroque" manufactured by Libby-Owens-Ford Co., ¼ thick clear glass, reinforced with welded wire mesh 24 gage or heavier, with square openings not larger than ½, PPG Industries, Inc., or equal. 6. Obscure Glass: a. "Burlap" manufactured by Hordis Brothers, Inc.;.200 patterned glass, PPG Industries, Inc., or equal. 7. Very Low Transmission Glass (V.L.T.) "Solargray"; 7 / 32 thick; tempered where required. 08810-2

8. Very Low Transmission Glass (V.L.T.) at Butt-joint Glazing: "Solargray"; ½ thick; tempered where required, or equal, no known equal. 9. Spandrel Glass: "Spandrelite"; ¼ thick, heat strengthened with permanent, colored ceramic frit fused to interior face; color as selected by Owner's Representative. 10. Reflective Glass: "Solarcool Gray"; ¼ thick, annealed with permanent gray color, light and heat reflective metallic oxide coating, fired on exterior face, tempered where required. 11. Reflective Spandrel Glass: "Solarcool Gray Spandrelite"; ¼ thick, heat strengthened with permanent gray color, light and heat reflective metallic oxide coating fired on exterior face, and opaque, colored ceramic frit fused permanently to interior face. Interior color as selected by Owner's Representative. 12. Insulated Glass Units: ASTM E774 and E773; double pane with glass elastomer edge seal; outer pane 7 / 32 clear glass, innerpane of 3 / 16 clear glass; inter pane space purged by dry air; total unit thickness of 29 / 32. IGCC class CBA rating. 13. Laminated Safety Glass: ¼ thick, tinted 14% light transmittance, consisting of two ⅛ inch thick lites laminated with special plastic interlayer between. 14. Acoustic Insulated Glass: Two (2) laminated ¼ glass panes with special acoustic edge seal; ½ total thickness; STC rating of 38. 15. One-way Vision Glass: a. "Mirropane" manufactured by Libby-Owens-Ford Co.; ¼ thick glazing quality, tempered clear glass with scratch-proof evaporated chromium alloy reflective coating one side, PPG Industries, Inc., or equal. 16. Leaded Glass: C. Acrylic Plastic Glazing: a. Manufactured by Ameray Corp; thickness as required to provide X-ray absorption equal to that provided by 1 / 16 thick sheet lead, Nuclear Associates Division of Victoreen, Inc., or equal. 1. Lexan Products Division of the General Electric Co.; ¼ thick gray, 14% visible light transmission, AtoHaas North America, Inc., or equal. D. Glazing Materials: 1. General: Factory mixed materials recommended by glass manufacturer for each glazing condition. Provide glazing and bedding putties to match color of frame, sealants, tapes, and other materials necessary to perform glazing work. Provide setting blocks, shims, compression seals, felt and neoprene or vinyl glazing channels as required. 2. Butyl Glazing Tape: a. General: 1202T as manufactured by 3M Construction Markets, the Pecora Corp., or equal. 08810-3

E. Accessories: PART III - EXECUTION 3.01 PREPARATION 1. General: Materials recommended by glass or glazing material manufacturer. 2. Setting Blocks and Spacers: Neoprene chemically compatible with specified sealants. 3. Glazing Points and Spring Wire Clips: Corrosion resistant. 4. Filler Rod: Compressible synthetic rubber or foam. 5. Primer-Sealers and Cleaners: As recommended by glass manufacturer. A. Surface Preparation: Clean contact surfaces with solvent and wipe dry. Seal porous glazing channels or recesses with material compatible with sealer. Prime surfaces scheduled to receive sealant. 3.02 INSTALLATION A. General: Install in conformance with referenced standards, manufacturer's written directions, as shown, and as specified. B. Glass: 1. Dimensions: As shown; tolerances as recommended by manufacturer. 2. Edges: Per referenced standards; nipped edges, or edges treated with abrasives are not acceptable. C. Glazing: 08810-4 1. General: Use glass as shown; glaze with glazing compound or glazing gaskets as required. 2. Float Glass: Type and thickness, as shown. 3. Tempered Glass: a. General: Type and thickness, as shown. b. Tinted: Install at exterior, as shown. c. Heat Absorbing: Install at exterior, as shown. d. Reflective: Install at exterior, as shown. e. Spandrel: Install at exterior, as shown. 4. Wire Glass: Install where shown; set with wire square to opening. 5. Obscure Glass: Install where shown; set with pattern on interior side.

6. Insulated Glass Units: a. General: Install on exterior, where shown. b. Low-E Glass: Install coated surface on inside of insulated glazed units. 7. Laminated Safety Glass: Install where shown. 8. Acoustic Insulated Glass: Install in acoustic rated frames, where shown. 9. One-way Vision Glass: Set with preformed glazing strips, with reflective surface on observation side. 10. Leaded Glass: Install in lead lined frames, where shown. 11. Plastic Glazing: Cut to size; unmask sheets and clean edges; set sheets with glazing tape, per manufacturer's directions. Protect plastic glazing from damage with paper or cloth covering. 12. All individual panes of safety glazing shall have a permanent seal (mark) indicating type of glaze. D. Special Conditions: 1. Glass Shelves: ¼ thick, tempered, with all edges rounded. 2. Display Case Glass: ¼ thick, tempered, with ground edges and finger pulls. E. Wood Stops: Do not glaze openings in wood doors or openings with wood stops until rebates and stops have been prime-coated as specified in Division 9, Section 09900 Painting. 3.03 CLEANING A. General: Upon completion, thoroughly clean glass and frames of labels, smears, spots and other markings or defacement. Do not use alkaline or abrasive agents to clean glass. END OF SECTION 08810 08810-5