COMPOSITE VIDEO SIGNAL

Similar documents
AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

PCM Encoding and Decoding:

Prepared by: Paul Lee ON Semiconductor

Operational Amplifier as mono stable multi vibrator

Composite Video Separation Techniques

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

Case study: how to use cutoff conditions in a FRA frequency scan?

Timing Errors and Jitter

TV Trouble Shooting Manual

Video Matrix Switches and Bandwidth

Experiment # 9. Clock generator circuits & Counters. Eng. Waleed Y. Mousa

Parameter values for the HDTV standards for production and international programme exchange

MONOCHROME RGB YCbCr VIDEO DIGITIZER

Understanding Video Latency What is video latency and why do we care about it?

Electrical Resonance

ARRL Morse Code Oscillator, How It Works By: Mark Spencer, WA8SME

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

A Lesson on Digital Clocks, One Shots and Counters

8B/10B Coding 64B/66B Coding

FREE TV AUSTRALIA OPERATIONAL PRACTICE OP42

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Frequency Response of Filters

Chapter 5 Fundamental Concepts in Video

RC Circuits and The Oscilloscope Physics Lab X

Light scene push button 8gang comfort flush-mounted xx

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

The D.C Power Supply

Lab 5 Getting started with analog-digital conversion

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Lock - in Amplifier and Applications

Fast and Accurate Test of Mobile Phone Boards

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Synchronization and Timing Issues in the Broadcast Environment. Ralf Herrmann Application Engineer

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

A Simple CCD Based Lane Tracking System

Objectives. Electric Current

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

A Lesson on Digital Clocks, One Shots and Counters

ONBACK. We Offer Full Systems, Monitors, Cameras and Accessories. Call Us Toll Free: Fax: Website:

1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver

Lab 1: The Digital Oscilloscope

Wiki Lab Book. This week is practice for wiki usage during the project.

Low Cost Pure Sine Wave Solar Inverter Circuit

INTERFERENCE OF SOUND WAVES

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Pulse Width Modulation (PWM) LED Dimmer Circuit. Using a 555 Timer Chip

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

Power Supplies. 1.0 Power Supply Basics. Module

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

Analog and Digital Signals, Time and Frequency Representation of Signals

High-speed Photography with a Still Digital Camera

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

Television. This chapter introduces you to the subject of TV technology. It embodies almost. Objectives. chapter

MATERIALS. Multisim screen shots sent to TA.

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)

Alerts & Filters in Power E*TRADE Pro Strategy Scanner

A Multichannel Storage Capacitor System for Processing of Fast Simultaneous Signals. Atsushi Ogata. IPPJ-T-16 Oct. 1973

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

Hands On ECG. Sean Hubber and Crystal Lu

Making Basic Measurements. Publication Number August Training Kit for the Agilent Technologies Series Logic Analysis System

Below is a diagram explaining the data packet and the timing related to the mouse clock while receiving a byte from the PS-2 mouse:

DIGITAL COUNTERS. Q B Q A = 00 initially. Q B Q A = 01 after the first clock pulse.

Fundamentals of Signature Analysis

CCTV System Troubleshooting Guide

Face detection is a process of localizing and extracting the face region from the

RECOMMENDATION ITU-R BO.786 *

Technical Information Short-Circuit Currents Information on short-circuit currents of SMA PV inverters

RECOMMENDED STANDARDS FOR DIGITAL TAPE FORMATS 1

TRADING SECRET NO. 3 How to combine two simple tools to capture big trending moves, especially in currencies

Clock Jitter Definitions and Measurement Methods

Ameritron ATP-102 Tuning Pulser II

Op Amp Circuit Collection

Understanding Power Impedance Supply for Optimum Decoupling

Instruction Manual Service Program ULTRA-PROG-IR

MM74HC4538 Dual Retriggerable Monostable Multivibrator

Accurate Measurement of the Mains Electricity Frequency

HOW TO SELECT VARISTORS

MANUAL FOR RX700 LR and NR

Vi, fi input. Vphi output VCO. Vosc, fosc. voltage-controlled oscillator

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Lip-Sync Measurement (AV Delay) for TV Displays Application Note

FEATURES DESCRIPTION APPLICATIONS BLOCK DIAGRAM. PT2248 Infrared Remote Control Transmitter

IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33.

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

Cross-beam scanning system to detect slim objects. 100 mm in

25. AM radio receiver

Transcription:

COMPOSITE VIDEO SIGNAL

COMPOSITE VIDEO SIGNAL Consist of : Camera signal - corresponding to the desired picture information Blanking pulses to make the retrace invisible Synchronizing pulses to synchronize the transmitter and receiver scanning -horizontal sync pulse -vertical sync pulse -their amplitudes are kept same -but their duration are different -needed consecutively and not simultaneously with the picture signal so sent on a time division basis

Composite Video Signal contd

Composite video signal contd Video signal varies between certain limits Peak white level: 10 to 12.5% Black level : 72% Blanking level : Sync pulses added - 75% level Pedestal : difference between black level and blanking level tend to merge Pedestal height : distance between the pedestal level and the dc level indicates the average brightness Picture information : 10% - 75% Darker the picture higher will be the voltage within those limits

DC component of the video signal Average value or dc component corresponding to the average brightness of the scene Average brightness can change only from frame to frame and not from line to line Low pedestal height scene darker Larger pedestal height higher average brightness

blanking pulses... Make the retrace lines invisible by raising the signal amplitude slightly above the black level (75%) Repetition rate of horizontal blanking pulse = scanning freq. = 15625Hz Freq of vertical blanking pulse = field scanning freq. = 50 Hz

Sync Pulse and Video Signal Amplitude Ratio P/S RATIO = 10/4 Justification: If the picture signal amplitude is at the expense of sync pulses when S/N ratio at the receiver falls, sync pulse amplitude becomes insufficient to keep the picture locked If the sync pulse amplitude is at the expense of the picture signal, then the raster remains locked but the amplitude of the picture content will be too low P/S ratio of 10/4 represents the most efficient use of TV system

horizontal Sync details...

horizontal sync details contd Total line period = 64µS Line blanking period = 12µS Differential leading edges are used for synchronizing horizontal scanning oscillator Divided into three sections : front porch : 1.5µS - allows the receiver video to settle down line sync : 4.7 µs - for blanking the flyback/retrace - blacker than the black back porch : 5.8µS - time for the horizontal time base circuit to reverse the direction of current for scanning the next line - same amplitude as that of blanking level ; used by AGC circuits at the receiver to develop true AGC voltage

Vertical Sync details

Vertical Sync details contd. Added after each fields Complex in nature Vertical sync period = 2.5 to 3 times the horizontal line period In 625 line system: 2.5 64 = 160µS Commence at the end of first half of 313 th line (end of first field) and terminates at the end of 315 th line Similarly after an exact interval of 20mS (one field period), the next sync pulse occupies the line numbers 1 st, 2 nd and first half of 3 rd.

Vertical sync details contd Horizontal sync information is extracted from the sync pulse train by differentiation i.e. Passing the pulse train through an HPF leading edges are used to synchronize the horizontal scanning oscillator Furthermore, receivers often use monostable multivibrators to generate horizontal scan, and so a pulse is required to initiate each and every cycle of the horizontal oscillator in the receiver.

Shortcomings and its solution 1. Horizontal sync pulses are available both during the active and blanked line periods but there are no sync pulses (leading edges) available during the 2.5 line vertical sync period horizontal sweep oscillator would tend to step out of synchronism during each vertical sync period The situation after an odd field is even worse -since it begins at midway -leading edge of the vertical sync pulse comes at the wrong time to provide synchronism for the horizontal oscillator Therefore five narrow slots (4.7µS width) are cut in the vertical sync pulse at intervals of 32µS rising edges are used to trigger horizontal oscillator. This insertion of short pulses : called notching of serration of the broad field pulses

Shortcomings and its solution.contd notching of serration of the broad field pulses notching of serration of the broad field pulses

Shortcomings and its solution.contd 2. It is seen that the synchronization of the vertical sweep oscillator in the receiver is obtained from vertical sync pulses by integrator (LPF) Voltage built across the capacitor of the LPF corresponding to the sync pulse trains of both the fields is shown in fig.

Shortcomings and its solution.contd Each horizontal pulse cause a slight rise in voltage across the capacitor, but this is reduced to zero by the time the next pulse arrives (charging period=4.7µs and discharging period = 59.3µS) But during broad serrated region, capacitor has more time to charge and only 4.7µS to discharge Situation is different for the beginning of the 2 nd field-here the last horizontal pulse corresponding to the beginning of the 313 th line is separated from the first vertical pulse by only half-a-line. Therefore the voltage developed a/c the vertical filter will not have enough time to reach zero before the arrival of the 1 st vertical pulse Hence the voltage developed a/c the o/p filter is some what higher at each instant as compared to the voltage developed at the beginning of the 1 st field (shown as dotted chain) i.e. Oscillator get triggered a fraction of a second early as compared to the first field - upset the desired interlacing sequence Equalizing pulses are used to solve this problem

Equalizing pulses Solves the shortcomings occurring on account of half line discrepancy Five narrow pulses of 2.5 line period are added on either side of the vertical sync pulses : known as pre-equalizing and post-equalizing pulses The effect of these pulses is to shift the half line discrepancy away from both the beginning and end of the vertical sync pulses

Equalizing pulses... contd Pre-equalizing pulses: - 2.3µS duration - result in the discharge of the capacitor to zero voltage in both the fields Post-equalizing pulses: necessary for a fast discharge of the capacitor to ensure triggering of the vertical oscillator at proper time With the insertion of equalizing pulses: - the voltage rise and fall profile is the same for both the field sequences - the vertical oscillator is triggered at the proper instants. i.e. exactly at an interval of 1/50 th of a second.