Technical Bulletin, Instructions for Installing New Hardware OMNI 6000

Similar documents
EMBEDDED ACCESS CONTROL Hardware Installation Guide

8 Channel Status Input Panel model SIP-8

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Troubleshooting and Diagnostics

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Comfort Control Relay Panel (CCRP)

JDSU PathTrak. HCU200 Install User s Guide

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

HM-W536 Install Guide

BACnet Automation Interface Module (Network Version)

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SYSTEM 4C. C R H Electronics Design

WD-AMX Water Detection Controllers

INSTALLATION & SERVICE MANUAL. Display Panel

S2A6620 Technical Service Bulletin. Cache Protect Battery Replacement

IO-DIM6 6-Channel, Digital to Analogue Converters

PowerLogic Sub Meter Display (SMD and SMDOPN)

HP UPS R1500 Generation 3

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

USB PC Adapter V4 Configuration

Bristol ControlWave Redundant Control

Dash 8Xe / Dash 8X Data Acquisition Recorder

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

NC-12 Modbus Application

Configuration Instructions

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

ENCODER TEST MODULE APPLICATION GUIDE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

EDI Distributor Control Interface Wiring and Setup Instructions

Universal Serial Bus (USB) to DH-485 Interface Converter

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Allen-Bradley/Rockwell

Troubleshooting and Diagnostics

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Application/Connection Examples

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Transmitter Interface Program

RIGtalk. Revision 5. Owner s Manual 2012.

INSTALLATION INSTRUCTIONS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

1 Serial RS232 to Ethernet Adapter Installation Guide

Electrical Safety Tester Verification

Installation manual. Version

SYSTEM 45. C R H Electronics Design

Current Monitoring Kit QUICK START GUIDE

CITY OF LOS ANGELES CALIFORNIA

BroadBand PowerShield. User Manual

Innovative Electronics for a Changing World INDEX

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

210E - 210ECL ECL ECL RMS Signal Monitor. Operations Manual

PRO PLM Installation Instructions

In-Sight Hardware specifications

AXIS 205 Network Camera Quick Installation Guide

Current Monitoring Kit

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

SECTION LOW VOLTAGE LIGHTING CONTROLS

Chapter 1 Installing the Gateway

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

INSTRUCTION MANUAL MODEL PCD-88

Digital and Analog I/O

Advantium 2 Plus Alarm

Zebra Ethernet. Frequently Asked Questions

HP Advanced Wireless Docking Station. User Guide

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

=============================== WARNING

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Grounding Demystified

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

Daikin Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Wash Select II to WashPay Integration Field Retrofit Installation Guide

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

ROC800-Series Advanced Pulse Module

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Technical Support Information No. 113 Revision 2.0 March 2005

Current Probes. User Manual

EZ-View Network Communications Guide

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Transcription:

Last Updated: 21-July-2010 TB-070216C Technical Bulletin, Instructions for Installing New Hardware OMNI 6000 OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States of America Phone-281.240.6161 Fax: 281.240.6162 www.omniflow.com 52-0001-0007/Rev C Page 1 of 13

Table of Contents Scope...3 Abstract...3 I/O A/B Combo Module 68-6006...4 I/O E/D and E Combo Module 68-6008...5 SV I/O Module 68-6203...6 SMT Version I/O A/B Combo Module 68-6206...7 HART I/O Module 68-6207...8 SMT Version I/O E/ED Combo Module 68-6208...9 SE Ethernet Module 68-6209...10 Digital I/O Module 68-6211...11 Universal Power Supply Module 68-6218...12 Figures Figure 1. I/O A/B Combo Module 68-6006 Jumper Settings...4 Figure 2. I/O E/D and E Combo Module 68-6008 Jumper Settings...5 Figure 3. SV I/O Module 68-6203 Module Jumper Settings...6 Figure 4. SMT I/O A/B Combo Module 68-6206 Jumper Settings...7 Figure 5. HART I/O Module 68-6207 Jumper Settings...8 Figure 6. SMT I/O E/ED Combo Module 68-6208 Jumper Settings...9 Figure 7. SE Ethernet Module 68-6209 Module Jumper Settings...10 Figure 8. Digital I/O Module 68-6211 Module Jumper Settings...11 Figure 9. Universal Power Supply Module 68-6218...12 52-0001-0007/Rev C Page 2 of 13

Scope Users are requested to verify the jumper settings on modules before installing into a current system. This will prevent miss match I/O address and possible computer systems resetting because of address conflicts. Particular attention is required when installing an SV module into an existing system that does not contain an SV module per Figure 3 (Applications 23/27 and 21/25 only). This Technical Bulletin is applicable to all spare part modules. The information is targeted to qualified professionals only and compliments the OMNI User Manual Volume 1, System Architecture and Installation (50-0000-0001) for detailed instructions. NOTE: SMT is Surface Mount Technology which is the manufacturing method on circuit board assembly. Abstract This Technical Bulletin contains information on the I/O modules and the standard factory jumper settings on these modules when they are purchased as spare parts to add to existing system or to replace a damaged module. WARNING: DANGER ELECTRICAL SHOCK HAZARD Dangerous AC voltages are present on the power supply module and ribbon cable when the unit is AC powered. To avoid electrical shock, that could be fatal; it is imperative that you remove all power before opening and disassembling the flow computer and take all necessary precautions. Only qualified Technicians should work on internal circuitry and perform flow computer upgrades. OMNI Flow Computers, Inc. is not responsible for personal injuries or accidents that may occur when working on flow computer circuitry. Static electricity can damage flow computer circuitry. Use approved static device handling precautions. When removing the CPU Module, take extreme care not to bend or fold the keypad membrane ribbon cable, as this could damage the metallic traces. Before installing your new or repaired module you will need to verify certain jumper settings for the module you are using. This is due to the fact that these modules have a selectable type address. Normally this is preset at the factory; however it is up to the user to verify/change the address simply by selecting the correct type of card and address on the selection jumpers located on the module. Failure to do so, will cause the unit not to recognize the newly installed module, lose existing data, or in some cases a system failure. Within this document we have addressed the various jumper settings required to properly install the module. 52-0001-0007/Rev C Page 3 of 13

I/O A/B Combo Module 68-6006 When installing a new or repaired Combo Module (68-6006) note that the modules will also require the inputs and outputs to be calibrated (Figure 1). Under Password Maintenance scroll down to entries, Input Cal Default and D/A Cali Default, enter Y or the required I/O Point number on both entries to reset to the factory calibration defaults. New combo modules added will require that the Check Modules entry is executed. Then proceed with the calibration procedure as described in User Manual, Volume 1, System Architecture and Installation Chapter 8 (50-0000-0001). JP11 Chan 4 Threshold JP11 In = 3.5 VDC Select P (Pulse Type Input - Channel 3 or 4) 4-20mA Jumper Out (Pulse Type Input) JP11 Select Module Type JPB Out = A Type Address Select (Address #2 Shown) Module A0 A1 A2 #1 Out Out Out #2 In Out Out #3 Out In Out #4 In In Out #5 Out Out In #6 In Out In RTD2 JP12 D/A2 JP12 In D/A2 Position JP13 In DC Coupled Position Figure 1. I/O A/B Combo Module 68-6006 Jumper Settings 52-0001-0007/Rev C Page 4 of 13

I/O E/D and E Combo Module 68-6008 When installing a new or repaired Combo Module (68-6008) note the modules will also require the inputs and outputs to be calibrated (Figure 2). Under Password Maintenance scroll down to entries, Input Cal Default and D/A Cali Default, enter Y or the required I/O Point number on both entries to reset to the factory calibration defaults. New combo modules added will require that the Check Modules entry is executed. Then proceed with the calibration procedure as described in User Manual, Volume 1, System Architecture and Installation Chapter 8 (50-0000-0001). For I/O E/D and E Combo Modules 68-6008 settings refer to Figure 2. Input Threshold Select JP8&JP1 In = +3.5 Volt DC Out=1.2Volt DC Select Module Type JPD In = E/D Module JP8 THRES JP3 JP4 RTD 4-20 INPUT 1 RTD Selected JP3 JP5 JP4 RTD 4-20 INPUT 1 JP6 JP8 THRES JP1 THRES RTD 4-20 INPUT 2 JP2 JP7 Address Select (Address #2 Shown) Module A0 A1 A2 #1 Out Out Out #2 In Out Out #3 Out In Out #4 In In Out #5 Out Out In #6 In Out In JP2 AC DC AC INPUT 4 AC Coupling Select AC DC AC INPUT 4 JP7 AC DC AC INPUT 3 AC DC AC INPUT 3 JP5 RTD 4-20 INPUT 2 DC Coupling Select JP6 4-20 ma Selected Figure 2. I/O E/D and E Combo Module 68-6008 Jumper Settings 52-0001-0007/Rev C Page 5 of 13

SV I/O Module 68-6203 Spare SV 68-6203 modules ordered from the factory are set up as address SV1 with BRD SEL jumper in, and IRQ set to 2. If you are installing a SV module into a new system where existing serial modules are installed, you MUST change the IRQ setting on all serial cards to IRQ 3 (Figure 3). Failure to do this will cause a system failure. Calibration on all analog outputs will need to be performed. Jumper In = 1 st SV Module Jumper Out = 2 nd SV Module SV Address Selection Jumpers IRQ 2 Always Selected LED Indicators PORT 1 (3) PORT 2 (4) RTS Always Selected Both Jumpers In = Port Terminated Both Jumpers Out = Port Unterminated Transmitting (TX)/Ready-to- Send (RTS) LEDs Red Receiving LEDs Green SV RS-485 Termination Jumpers Figure 3. SV I/O Module 68-6203 Module Jumper Settings 52-0001-0007/Rev C Page 6 of 13

SMT Version I/O A/B Combo Module 68-6206 Modules issued as spare parts or replacement modules will be jumpered as A1 Modules When installing a new or repaired Combo Module (68-6206) note the modules will also require the inputs and outputs to be calibrated (Figure 1). Under Password Maintenance scroll down to entries, Input Cal Default and D/A Cali Default, enter Y or the required I/O Point number on both entries to reset to the factory calibration defaults. New combo modules added will require that the Check Modules entry is executed. Then proceed with the calibration procedure as described in User Manual, Volume 1, System Architecture and Installation Chapter 8 (50-0000-0001). Figure 4. SMT I/O A/B Combo Module 68-6206 Jumper Settings 52-0001-0007/Rev C Page 7 of 13

HART I/O Module 68-6207 Spare HART Modules must be specified as either a HT or HM Module (Figure 5). A label marked HT or HM will be applied to the module. Load resistor jumpers are provided and will be installed in the OUT position (Figure 4). Refer to Technical Bulletin 090003 (52-0000-0019) for additional information on the setup of this Module. MODULE ADDRESS AD1 AD2 LOAD RESISTORS NETWORK 1 Figure 5. HART I/O Module 68-6207 Jumper Settings 52-0001-0007/Rev C Page 8 of 13

SMT Version I/O E/ED Combo Module 68-6208 Modules issued as spare parts or replacement modules will be jumpered as E1 or E/D1 modules (Figure 6). When installing a new or repaired Combo Module (68-6208) note the modules will also require the inputs and outputs to be calibrated (Figure 1). Under Password Maintenance scroll down to entries, Input Cal Default and D/A Cali Default, enter Y or the required I/O Point number on both entries to reset to the factory calibration defaults. New combo modules added will require that the Check Modules entry is executed. Refer to OMNI User Manual Volume 1 System Architecture and Installation (50-0000- 0001) for detailed instructions on the jumper settings. SELECT APPROPRATE MODULE ADDRESS JUMPERS INPUT2 A0 A1 A2 RTD 4-20 MOD 1 MOD 2 MOD 3 INPUT2 RTD 4-20 MOD 4 MOD 5 A0 A1 A2 JPD MOD 6 SELECT APPROPRATE MODULE TYPE JUMPER JUMPER JPD TYPE E D E Figure 6. SMT I/O E/ED Combo Module 68-6208 Jumper Settings 52-0001-0007/Rev C Page 9 of 13

SE Ethernet Module 68-6209 Spare SE Ethernet modules from the factory are set up as address S1 with no jumpers in A1 or A2 (Figure 7). If you are installing this module into an existing Flow Computer with installed serial modules make sure you set up the correct address for the SE Ethernet module before you install. NOTE: EPROM/Flash revision for current update of xx.74 and xx.75 will you see the module address SE in the Status Screen, all other revisions below currently indicate S only. Application 21/25 currently does not support Network Printing and will display the SE module as an S module. Refer to Technical Bulletin 980503 (52-0001-0003) for detailed instructions for installation of the Serial module and Technical Bulletin 020101 (52-0001-0006) for the SE Ethernet module. Figure 7. SE Ethernet Module 68-6209 Module Jumper Settings IRQ SELECTION NOTE: A jumper is provided for selecting the interrupt request (IRQ) level of the module, IRQ 2 or 3 can be selected. The Jumper should be configured to use IRQ 2 unless an SV module is installed. IRQ 3 must be used if an SV module is in the flow computer. 52-0001-0007/Rev C Page 10 of 13

Digital I/O Module 68-6211 Spare Digital I/O Modules from the factory are setup as address D1 with JP1 in and JP2 set to channel 1 (Figure 9). If you are installing this module as address D2 set up the address jumper on JP4, IN and JP5, OUT and remove both jumpers on JP 1 and JP2. Interrupt Request (IRQ) Select Jumpers for Pipe Prover Detector (Non-Double Chronometry) Neither Jumper is Required for D2 Module Assign IRQ to I/O Point #1 Assign IRQ to I/O Point #2 JP2 JP2 JP1 In = Rising Edge Trigger JP1 Out = Falling Edge Trigger JP1 JP2 JP4 JP5 Figure 8. Digital I/O Module 68-6211 Module Jumper Settings 52-0001-0007/Rev C Page 11 of 13

Universal Power Supply Module 68-6218 The Universal Power Supply can automatically accept any AC input from 110 to 250 volts at 50/60 Hz. This Universal Power Supply (Figure 10) is backwards compatible with 68-6118 PSU. It can be used in the 3000 and 6000 flow computers with the exception of very early flow computers where the AC was not connected to the power supply using a separate four conductor ribbon. The AC fuse on units previously using the older 68-6118 PSU needs to increase in amperage to handle all voltages and surge currents. Spare fuses are provided when ordering a spare Universal Power Supply. Figure 9. Universal Power Supply Module 68-6218 52-0001-0007/Rev C Page 12 of 13

DOCUMENT REVISION HISTORY DOCUMENT INITIAL RELEASE DATE...N/A-February-2007 REVISION DATE PURPOSE / CHANGE REQUEST A N/A-February-2007 Maintained on the Web - Initial release B 26-March-2009 DCR 090072 C 21-July-2010 DCR 100123 52-0001-0007/Rev C Page 13 of 13