Photovoltaic Solar Energy Modular Trainers

Similar documents
Photovoltaic Solar Energy Unit EESFB

Computer Controlled Photovoltaic Solar Energy Unit, with SCADA EESFC

Audio and Video Door Entry System LIELBA - AD14

Remote Control Station Via Telephone

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Automobile Air Conditioning Trainer, with SCADA TAAUC

Computer Controlled Nozzle Performance Test Unit, with SCADA TFTC

Computer Controlled Axial Fan Teaching Trainer, with SCADA HVAC

Telephony Systems Trainer CODITEL

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

46120-F0 Solar Energy Training System

BB800 Off-Grid Solar System

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Computer Controlled Stirling Motor, with SCADA TMSC

Computer Controlled Teaching Cottage Cheese Maker, with SCADA and PID Control RDC

Computer Controlled Chemical Reactors Trainer, with SCADA and PID Control QRC

Application Note: String sizing Conext CL Series

High Power Programmable DC Power Supplies PVS Series

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

IKS. Profi. Photovoltaic Trainingsystem for vocational and advanced training. Photovoltaik

Multi-Range Programmable DC Power Supplies 9115 Series

SOLAR I-V Rel /07/10

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Experiment 5. Strain Gage Measurements

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

New Energy Lab. Experiment Guide. New Energy Lab - Experiment Guide 1

DC Electronic Loads 8500 series

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Thyristor-controlled power supplies and battery chargers

Photovoltaic System Overcurrent Protection

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Additional Solar System Information and Resources


User s Manual Before using the inverter, you need to read and save the safety instructions.

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

FIREDEX Conventional Fire Panels

TruPower-Portable-500W. Solar Starter kit

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels

SL Series AC and DC Electronic Loads

Current Monitoring Kit

6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL.

ADDENDUM #1(BID PACKAGE # 3)

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

YSmart Technology Co.,Ltd

Your Sharp system will be supplied with one of the following sets of panels:

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Computer Controlled Process Control System (with electronic control valve), with SCADA and PID Control UCP

MAJORSINE Power Inverter

Physical Specifications (Custom design available.)

Multi-Range Programmable DC Power Supplies 9115 Series

MODULAR SYSTEM OF INVERTERS FOR PHOTOVOLTAIC SYSTEM AT THE TECHNOLOGY CENTRE OSTRAVA

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

GROWATT NEW ENERGY CO.,LTD. GR - UM

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

Voltech DC1000. Precision DC Bias Current Source

OUTPUT CABLE CONNECTIONS:

Quick Connect. quick - simple - efficient.

EGSTON Standard E2xFxWx 12W

Current Monitoring Kit QUICK START GUIDE

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Product Information Sheet UH28CS-12kV Hi Pot Tester

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

13 Watt PORTABLE SOLAR POWER KIT

How To Sell A Talan

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

How To Make A Fronius Cl Power Inverter

15 Series - Electronic step relay and dimmer. Features SERIE

SOLAR ELECTRIC SYSTEM KITS

EDIBON SCADA-NET System (ESN) for Chemical Engineering ESN-CHEMICAL ENGINEERING

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Contractors Guide Central Inverter System Installation

Fronius IG Plus. The next generation grid-connected PV inverter

Combi B Alarm box. Mounting instructions

Air conditioning, electrical testing

LN240(30)P-3-xxx ( W poly)

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

Everything you need for protection scheme testing

DIV Series Sine-Wave Inverter System Manual DIV12/220-XXXX L/W DIV24/220-XXXX L/W DIV48/220-XXXX L/W DIV220/220-XXXX L/W DIV220/220-XXXX L/W

3466 Building Energy Management Training Systems

FLOOR INDICATORS CATALOGUE 2007

FREJA 300 Relay Testing System

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications

The Universal DAQ Device. Connect and measure immediately!

4-Channel Thermometer / Datalogger

NetScanner System. Toronto: , Montreal: , Toll Free: ,

WHOLESALE DIRECT INC WEST 65TH STREET

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

COMPALARM AP GENERAL MAIN FEATURES

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Inverter / Charger Installation General Operations and AC and DC Connections

Virtual Laboratory for Study of Renewable Solar Energy

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Handheld portable appliance testers

Transcription:

Photovoltaic Solar Energy Modular Trainers Technical Teaching Equipment Products Products range Units 5.-Energy MINI-EESF. Photovoltaic Solar Energy Modular Trainer (Complete) MINI-EESF/M. Photovoltaic Solar Energy Modular Trainer (Intermediate) MINI-EESF/B. Photovoltaic Solar Energy Modular Trainer (Basic) GENERAL DESCRIPTION Photovoltaic Solar Energy Modular Trainer "MINI-EESF" is a laboratory scaled unit designed to study all the parameters involved in the solar radiation direct conversion into electricity. The trainer is based on some application modules and photovoltaic solar panels assembled in mobile structures. It is specially designed for the theoretical and practical study of the electrical installations with photovoltaic solar energy, the typical configurations used in photovoltaic installations and the operation of the different elements involved in the conversion. The power obtained from the solar energy can be: Regulated to obtain a DC power to charge a battery, studying parameters such as solar module s current output charge level, battery voltage, etc. Delivered to DC loads, studying parameters such as solar module s current output and current consumption by the loads. Converted to AC power to be delivered to AC loads, studying parameters such as current consumption by the loads. Injected to the grid, studying parameters such as simulated solar module s current and voltage outputs, power injected to the grid, mains voltage and frequency, etc. Three different versions are available with different practical possibilities and levels of difficulty: MINI-EESF, MINI-EESF/M and MINI-EESF/B. Worlddidac Member ISO 9000: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) Page 1 Certificates ISO 14000 and ECO-Management and Audit Scheme (environmental management) Worlddidac Quality Charter Certificate (Worlddidac Member)

Photovoltaic Solar Energy Modular Trainer (Complete) MINI-EESF N-ES20. Module N-ES90. Module N-ES30. Module N-ES10. Module N-ES50. Module N-ES40. Module N-ES80. Module Photovoltaic module EE-KIT2. Grid Connection Inverter Kit SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Supply and Consumption in alternating current (AC). Supply to the network (grid). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. N-ES30. DC/AC inverter that outputs a sinewave shaped output of 230V/50Hz ± 2% and the nominal input voltage is 12Vdc. Two different operating modes: continuous mode and ASB mode (Auto Standby) to reduce the power consumption. It is provided with a diagnosis system to indicate the user the status by different flash sequences. continue... Page 2

Specifications (continuation) N-ES40. AC Voltage measurements module until 250V. and DC until 250 V. (digital multimeter). N-ES50. Loads module that incorporates two lamps of 220V., 50 W., with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. EE-KIT2. Grid Connection Inverter Kit. Inverter used for the conversion and injection to the grid of the power generated by a simulated source of renewable energy. The simulated source is a simulator used to obtain a variable power to be injected to the grid. The operation mode is displayed by means of an indicating LED at the front side of the housing. It is equipped with extensive safety measures to ensure that it is immediately switched off as soon as the AC plug is removed from the wall socket or the operation of the public grid fails. The inverter can be connected to a computer (PC) through a RS232/USB communication to display some parameters, such as voltage and current inputs, mains voltage and frequency, maximum AC power, Kwh, etc. - Grid Connection Inverter: Input (DC): Nominal power @ 25ºC: 150 W. Maximum power @ 25ºC: 220 W. MPP voltage: 45-125V DC. Maximum voltage: 155V DC. Nominal current: 3A. Output (AC): Voltage: 230V (207-253 V). Maximum power, fuse: 2A. Frequency: 50 Hz (49.8 ~ 50.2 Hz). This unit is supplied with the Grid Simulator (ESR), which simulates a low power grid to inject the power generated by the inverter. - Grid Simulator (ESR): ESR is designed to create an isolated low power grid. The unit uses a battery as voltage source and generates a sine signal of 220V/50Hz. The main features of the ESR are: Inlet voltage source: battery of 12Vdc. Output: 220V/50Hz. Isolation transformer. Battery charger included. Protection fuses. The user can work with this module safely. The devices included in the EE-KIT2 can be used worldwide. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. EXERCISES AND PRACTICAL POSSIBILITIES Some Practical Possibilities of the Unit: 1.- Determination of the constituent material of the solar cell. 7.- Solar energy measurement. 2.- Determination of the I-V first quadrant curve without illuminating 8.- Measurement of the solar panel voltage with no load. the solar cell. 9.- Determination of the disposition of cells in a solar panel. 3.- Determination of the inverse (or saturation) current of the cell 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 4.- Determination of parallel and series resistance of a solar cell 12.- Loads connection to 220 Volts AC. 5.- Dependency of the open circuit voltage (V oc) with lumens 13.- Study of the grid utility inverter. (luminous flux). 14.- Battery charging. 6.- Determination of the parameters that describe the quality of a solar cell. MINI-EESF: Rack with modules: DIMENSIONS & WEIGHTS Dimensions: 645 x 325 x 925 mm. approx. (25.39 x 12.79 x 36.41 inches approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Grid Connection Inverter Kit: Dimensions: 550 x 410 x 820 mm. approx. (21.65 x 16.14 x 32.28 inches approx.) Weight: 30 Kg. approx. (66.13 pounds approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * Page 3

Photovoltaic Solar Energy Modular Trainer (Intermediate) MINI-EESF/M N-ES90. Module N-ES30. Module N-ES10. Module N-ES20. Module N-ES40. Module N-ES50. Module N-ES80. Module Photovoltaic module SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Supply and Consumption in alternating current (AC). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. N-ES30. DC/AC inverter that outputs a sinewave shaped output of 230V/50Hz ± 2% and the nominal input voltage is 12Vdc. Two different operating modes: continuous mode and ASB mode (Auto Standby) to reduce the power consumption. It is provided with a diagnosis system to indicate the user the status by different flash sequences. N-ES40. AC Voltage measurements module until 250V. and DC until 250 V. (digital multimeter). N-ES50. Loads module that incorporates two lamps of 220V., 50 W., with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. Page 4

Some Practical Possibilities of the Unit: EXERCISES AND PRACTICAL POSSIBILITIES 1.- Determination of the constituent material of the solar cell. 2.- Determination of the I-V first quadrant curve without illuminating the solar cell. 3.- Determination of the inverse (or saturation) current of the cell 4.- Determination of parallel and series resistance of a solar cell 5.- Dependency of the open circuit voltage (V oc) with lumens (luminous flux). 6.- Determination of the parameters that describe the quality of a solar cell. 7.- Solar energy measurement. 8.- Measurement of the solar panel voltage with no load. 9.- Determination of the disposition of cells in a solar panel. 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 12.- Loads connection to 220 Volts AC. 13.- Battery charging. MINI-EESF/M: Rack with modules: DIMENSIONS & WEIGHTS Dimensions: 645 x 325 x 925 mm. approx. (25.39 x 12.79 x 36.41 inches approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * Page 5

Photovoltaic Solar Energy Modular Trainer (Basic) MINI-EESF/B N-ES10. Module N-ES20. Module N-ES90. Module N-ES80. Module Photovoltaic module SPECIFICATIONS Main features: Supply and Consumption at 12 V (DC). Solar Panel (polycrystalline) mounted on an anodized aluminum structure with wheels for mobility, and with calibrated cell to measure solar irradiation. It consists of 36 high performance photovoltaic cells (35 x 55 mm), with a typical power of 50Wp for a 17Vdc voltage. Both the protections and the used materials give it water proof properties, abrasion protection, hail impact protection and several other adverse environmental factors protection. Technical data: Maximum nominal power: 66W. Voltage at maximum power point (Vmpp): 17.8 V. Current at maximum power point (Impp): 3.70 A. Short-circuit current (Isc): 4.05 A. Open circuit voltage (Voc): 22.25 V. Dimensions: 660 x 35.5 x 780 mm. Weight: 3 Kg. approx. Battery offering optimal performance with low power applications. Set of interconnection cables. Rack for modules allocation: Modules: N-ES10. Solar charge controller with an automatic recognition for operating voltage 12 V or 24 V. It monitors several parameters such as voltage, current and charge level of the battery, load current, status, etc. Additional functions can be activated such as the settings, night light function and auto-test. The regulator is equipped with various devices to protect its electronics, battery and load. N-ES20. Loads module that incorporates two 12 V, 20W lamps, with independent switches. 2 N-ES80. Module for measurements of solar irradiation (W/m ) and measurements of current until 10 A., with digital multimeter. N-ES90. Module for 12Vdc battery charger. Cables and Accessories, for normal operation. Manuals: This unit is supplied with the following manuals: Required Services, Assembly and Installation, Starting-up, Safety, Maintenance & Practices Manuals. Page 6

Some Practical Possibilities of the Unit: EXERCISES AND PRACTICAL POSSIBILITIES 1.- Determination of the constituent material of the solar cell. 2.- Determination of the I-V first quadrant curve without illuminating the solar cell. 3.- Determination of the inverse (or saturation) current of the cell 4.- Determination of parallel and series resistance of a solar cell 8.- Measurement of the solar panel voltage with no load. 9.- Determination of the disposition of cells in a solar panel. 10.- Familiarisation with the regulator parameters. 11.- Loads connection to 12 Volts DC. 12.- Battery charging. 5.- Dependency of the open circuit voltage (V oc) with lumens (luminous flux). 6.- Determination of the parameters that describe the quality of a solar cell. 7.- Solar energy measurement. MINI-EESF/B: Rack with modules: DIMENSIONS & WEIGHTS Dimensions: 645 x 325 x 670mm. approx. (25.39 x 12.79 x 26.37 inches approx.) Weight:6 Kg. approx. ( 13.22 pounds approx.) Dimensions: 730 x 510 x 1150 mm. approx. (28.74 x 20.07 x 45.27 inches approx.) Specifications subject to change without previous notice, due to the convenience of improvements of the product. * - PSA/PC. Polycrystalline photovoltaic solar panel. OPTIONAL ELEMENTS - PSA/MC. Monocrystalline photovoltaic solar panel. - PSA/AM. Amorphous photovoltaic solar panel. Page 7

Optional MINI-EESF/CAI. Computer Aided Instruction Software System: Trainer Instructor Software + Student Software With no physical connection between trainer and computer (PC), this complete software package consists of an Instructor Software (INS/SOF) totally integrated with the Student Software (MINI- EESF/SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. INS/SOF. Classroom Management Software (Instructor Software): Example of software screens Instructor Software The instructor can: Organize Students by Classes and Groups. Create easily new entries or delete them. Create data bases with student information. Analyze results and make statistical comparisons. Generate and print reports. Detect student s progress and difficulties....and many other facilities. This software working in network configuration allows controlling all the students in the classroom. MINI-EESF/SOF. Computer Aided Instruction Software (Student Software): Student Software It explains how to use the trainer, run the experiments and what to do at any moment. This Software contains: Theory: gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done with the trainer, showing how to complete exercises and practices. Exams: set of questions to test the obtained knowledge. For more information see CAI catalogue. Click on the following link: /products/catalogues/en/cai.pdf Page 8

Optional MINI-EESF/CAL. Computer Aided Learning Software (Results Calculation and Analysis): This Computer Aided Learning Software (Results Calculation and Analysis) CAL is a Windows based software, simple and very easy to use, specifically developed by EDIBON. CAL is a class assistant that helps in doing the necessary calculations to extract the right conclusions from data obtained during the experimental practices. With a single click, CAL computes the value of all the variables involved and performs the calculations. Also, CAL allows to plot and print the results. Within the plotting options, any variable can be represented against any other. Available different plotting displays. It has a wide range of information, such as constant values, unit conversion factors and integral and derivative tables. On a table, we introduce data obtained during the development of the exercise. Above this table, it is shown Constants theoretically involved with the field of study. The values of these Constants may be modified to our convenience, assigning the appropriate values. Simply, by clicking on "COMPUTE", CAL performs the calculations of the desired variables. We can save and print the data of the experiment or calculations. Also we can load any data file saved previously. With the calculated variables, CAL gives the option of plotting the results. It is possible to represent any variable against any other. It has the option of representing the graph with different layouts. Screens below give an example of the multiple choices. CAL has a wide range of help information. By clicking the button "ADDITIONAL HELP" opens a window where we have information about typical Constants, International System Units, Conversion Factors, and Table of Main Integrals and Derivatives (General), and there is other specific help for the particular unit. For more information see CAL catalogue. Click on the following link: /products/catalogues/en/cal.pdf Specifications subject to change without previous notice, due to the convenience of improvements of the product. * REPRESENTATIVE: C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). SPAIN. Phone: 34-91-6199363 FAX: 34-91-6198647 E-mail: edibon@edibon.com WEB site: Issue: ED02/14 Date: May/2014 Page 9