M67 HAND GRENADE HEAT TEST

Similar documents
Simulation of Air Flow Through a Test Chamber

Overview Presented by: Boyd L. Summers

Asset Management- Acquisitions

DEFENSE CONTRACT AUDIT AGENCY

Using the Advancement Degree of Difficulty (AD 2 ) as an input to Risk Management

THE MIMOSA OPEN SOLUTION COLLABORATIVE ENGINEERING AND IT ENVIRONMENTS WORKSHOP

Report Documentation Page

DCAA and the Small Business Innovative Research (SBIR) Program

REPORT DOCUMENTATION PAGE *

EAD Expected Annual Flood Damage Computation

Headquarters U.S. Air Force

PROBLEM STATEMENT: Will reducing the ASD for Kadena AB F-15 C/Ds increase the CPFH for this Mission Design Series (MDS)?

73rd MORSS CD Cover Page UNCLASSIFIED DISCLOSURE FORM CD Presentation

NAVSUP FLC NORFOLK PHILADELPHIA OFFICE

In June 1998 the Joint Military Intelligence. Intelligence Education for Joint Warfighting A. DENIS CLIFT

Advanced Micro Ring Resonator Filter Technology

Military Health System Conference

IISUP-. NAVAL SUPPLY SVSTE:MS COMMAND. Ready. Resourceful. Responsive!

Evaluation of a 10 kv, 400 ka Si SGTO at High di/dt

Pima Community College Planning Grant For Autonomous Intelligent Network of Systems (AINS) Science, Mathematics & Engineering Education Center

OPTICAL IMAGES DUE TO LENSES AND MIRRORS *

John Mathieson US Air Force (WR ALC) Systems & Software Technology Conference Salt Lake City, Utah 19 May 2011

Mr. Steve Mayer, PMP, P.E. McClellan Remediation Program Manger Air Force Real Property Agency. May 11, 2011

Dr. Gary S. E. Lagerloef Earth and Space Research, 1910 Fairview Ave E

Guide to Using DoD PKI Certificates in Outlook 2000

Issue Paper. Wargaming Homeland Security and Army Reserve Component Issues. By Professor Michael Pasquarett

RT 24 - Architecture, Modeling & Simulation, and Software Design

CAPTURE-THE-FLAG: LEARNING COMPUTER SECURITY UNDER FIRE

ACC-NJ Small Business Overview

AFRL-RX-WP-TP

DEFENSE BUSINESS PRACTICE IMPLEMENTATION BOARD

REPORT DOCUMENTATION PAGE

A GPS Digital Phased Array Antenna and Receiver

TITLE: The Impact Of Prostate Cancer Treatment-Related Symptoms On Low-Income Latino Couples

An Implicit Three-Dimensional Meteorological Message for Artillery Trajectory Calculation

E X A D A T A NEW EXPLOSIVES ACCIDENT DATABASE

ELECTRONIC HEALTH RECORDS. Fiscal Year 2013 Expenditure Plan Lacks Key Information Needed to Inform Future Funding Decisions

Determination of Volatile Organic Compounds Content Using Novel Ash and Total Solids Analysis for Chemical Agent Resistant Coating Systems

Non-Autoclave (Prepreg) Manufacturing Technology

Interagency National Security Knowledge and Skills in the Department of Defense

FIRST IMPRESSION EXPERIMENT REPORT (FIER)

Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope

Obsolescence Considerations for Materials in the Lower Sub-Tiers of the Supply Chain

CERT Virtual Flow Collection and Analysis

Army Environmental Policy and ISO 14001

Algorithmic Research and Software Development for an Industrial Strength Sparse Matrix Library for Parallel Computers

Graduate Level Credit for Resident EWS Students. Natasha McEachin CG 1

Ultra-low Sulfur Diesel Classification with Near-Infrared Spectroscopy and Partial Least Squares

An Overview of Romanian Command and Control Systems

Jack of All Trades, Master of None: Combat Engineer Officer Assignments in the Marine Corps. EWS Contemporary Issue Paper

THE NATIONAL SHIPBUILDING RESEARCH PROGRAM

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

Cancellation of Nongroup Health Insurance Policies

Assessment of NASA Dual Microstructure Heat Treatment Method Utilizing Ladish SuperCooler Cooling Technology

Leveraging Open Source Software to Create Technical Animations of Scientific Data

Microstructural Evaluation of KM4 and SR3 Samples Subjected to Various Heat Treatments

Integrated Force Method Solution to Indeterminate Structural Mechanics Problems

Small PV Systems Performance Evaluation at NREL's Outdoor Test Facility Using the PVUSA Power Rating Method

I N S T I T U T E F O R D E FE N S E A N A L Y S E S NSD-5216

AD-A DODPOPHM/USA/DOD/NADTR9 1107

An Oil-Free Thrust Foil Bearing Facility Design, Calibration, and Operation

PREPARED FOR: U.S. Army Medical Research and Materiel CommandFort Detrick, Maryland

UMass at TREC 2008 Blog Distillation Task

Aircraft Cleanability and Corrosion Issues 26 February Craig Matzdorf NAVAIR

Shaped Charge Jet Characterization and Initiation Test Configuration for IM Threat Testing

Figure 1 EMTAP 42 Tube Test - Electrically Heated

Award Number: W81XWH

SHOALS Toolbox: Software to Support Visualization and Analysis of Large, High-Density Data Sets

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

DEPARTMENT OF DEFENSE TEST METHOD STANDARD

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

An Application of an Iterative Approach to DoD Software Migration Planning

Human Body Mesh With Maya

High Power Density Capacitor Charging Power Supply Development for Repetitive Pulsed Power

K-Type Thermocouple Sensor User s Guide

Metamaterials and Transformation Optics

Mobile Robot Knowledge Base

Multiple Network Marketing coordination Model

ALCOHOL-TO-JET (ATJ) FUEL BLENDING STUDY

CONTRACTING ORGANIZATION: University of Alabama at Birmingham Birmingham, AL 35294

Elastomer Compatibility Testing of Renewable Diesel Fuels

The Acid Digestion Process (ADP) for Disposal of Sea Dumped Munitions

MINDS: A NEW APPROACH TO THE INFORMATION SECURITY PROCESS

TESTING AND ANALYSIS OF SURVIVABILITY OF SHAPED-CHARGES IN BULLET IMPACT CONDITIONS

Hydrologic Engineering Techniques for Regional Water Resources Planning

Monthly Status Briefing. July 2014

UNCLASSIFIED LOW-COST MINIATURE INTERFACE AND CONTROL SYSTEMS FOR SMART SENSORS, TACTICAL RADIOS, AND COMPUTER NETWORKS

FIRE PREVENTION PLAN

A Manager's Checklist for Validating Software Cost and Schedule Estimates

Transcription:

AD AD-E403 289 Technical Report ARMET-TR-09048 M67 HAND GRENADE HEAT TEST Eugene Homentowski Neha Mehta Gartung Cheng Carl Hu July 2010 U.S. ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER Munitions Engineering Technology Center Picatinny Arsenal, New Jersey Approved for public release; distribution is unlimited. 20100820113

The views, opinions, and/or findings contained in this report are those of the author(s) and should not be construed as an official Department of the Army position, policy, or decision, unless so designated by other documentation. The citation in this report of the names of commercial firms or commercially available products or services does not constitute official endorsement by or approval of the U.S. Government. Destroy this report when no longer needed by any method that will prevent disclosure of its contents or reconstruction of the document. Do not return to the originator.

REPORT DOCUMENTATION PAGE Form Approved OMBNo. 0704-01-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden to Department of Defense, Washington Headquarters Services Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law. no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) July 2010 4. TITLE AND SUBTITLE 2. REPORT TYPE Technical 3. DATES COVERED {From June 2009 5a. CONTRACT NUMBER To) M67 HAND GRENADE HEAT TEST 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS 5d. PROJECT NUMBER Eugene Homentowski, Neha Mehta, Gartung Cheng, and Carl Hu 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army ARDEC, METC Energetics, Warheads & Manufacturing Technology Directorate (RDAR-MEE) Picatinny Arsenal, NJ 07806-5000 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) U.S. Army ARDEC, ESIC Knowledge & Process Management (RDAR-EIK) Picatinny Arsenal, NJ 07806-5000 12. DISTRIBUTION/AVAILABILITY STATEMENT 8. PERFORMING ORGANIZATION REPORT NUMBER 10. SPONSOR/MONITOR'S ACRONYM(S) 11. SPONSOR/MONITOR'S REPORT NUMBER(S) Technical Report ARMET-TR-09048 Approved for public release; distribution is unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT The M67 hand grenade is a traditional pull-pin grenade widely used by the U.S. Army and Marine Corps. Pulling the pin in the grenade's fuze (the M213) releases the spoon and the hammer, which hits the primer at the top of the fuze body initiating the firing train. This fuze train is simple and has functioned well and reliably in grenades for decades. Unfortunately, it also has major safety issues. Any unwanted stimulus that causes the primer to function, like fire, initiates the entire fuze train. The large quantities of primary explosive in the detonator can also be detonated by external stimulus with enough energy to function the entire grenade. These problems are exacerbated when many grenades are in the same location, through sympathetic detonation. With the new design of grenade the body, heating tests were conducted on inert wax-filled M67 hand grenades and empty M67 hand grenades to see if grenade halves would separate when heated. 15. SUBJECT TERMS M67 grenade M213 fuze Slow cook-off 16. SECURITY CLASSIFICATION OF: a. REPORT U b. ABSTRACT U c. THIS PAGE u 17. LIMITATION OF ABSTRACT SAR 18. NUMBER OF PAGES 15 19a. NAME OF RESPONSIBLE PERSON Neha Mehta 19b. TELEPHONE NUMBER (Include area code) (973) 724-9212 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18

CONTENTS Page Introduction Test Descriptions Test Results Conclusions Recommendations Distribution List 1 2 2 9 9 11 FIGURES 1 M67 hand grenade 2 M213 fuze 3 Modified M67 grenade w/ inert M213 fuze 4 Sterno can heater 5 Sterno heater with can oven 6 Temperature data, Sterno heater 7 M67 temperature data, Sterno heater with can oven 8 Mesh pad heater 9 M67 temperature data, mesh pad heater 10 M67 with coiled wire heater 11 M67 temperature data, 2 nd test, coiled wire heater, 120 V w/r 12 M67 temperature data, 3 rd test, coiled wire heater, 120 V w/r 13 M67 temperature data, 4 th test, coiled wire heater, 120 V w/r 14 Variac heater control circuit 15 M67 temperature data, 1 st test, coiled wire heater, 120 V w/r 1 1 2 3 3 4 4 5 5 5 6 6 7 7 7

FIGURES (continued) Page 16 M67 temperature data, 2 nd test, coiled wire heater, 120 V w/r 8 17 M67 temperature data, 3 rd test, coiled wire heater, 120 V w/r 8 18 M67 temperature data, 4 th test, coiled wire heater, 120 V w/r 8 19 M67 temperature data, 5 th test, coiled wire heater, 120 V w/r 9

INTRODUCTION The M67 hand grenade (fig. 1) is a traditional pull-pin grenade, widely used by the U.S. Army and Marine Corps. Pulling the pin in the grenade's fuze (the M213) releases the spoon and the hammer, which hits the primer at the top of the fuze body (fig. 2), initiating the firing train. The delay mix is ignited by the primer and burns several seconds before initiating the attached C70 detonator. This detonator is massive, containing approximately 10 times more lead styphnate, lead azide, and RDX than other detonators such as M55, M61, etc. This size is not simply a case of over engineering; the length is required to properly initiate the grenade's explosive fill for good fragmentation, while its diameter is dictated by the dimensions of the fuze body. Figure 1 M67 hand grenade PRIMER FUZE BODY DELAY MIX LEAD STYPHNATE LEAD AZIDE RDX DETONATOR CASE Figure 2 M213 grenade fuze (spoon and hammer not pictured)

This fuze train is simple and has functioned well and reliably in grenades for decades. Unfortunately, it also has major safety issues. Any unwanted stimulus that causes the primer to function, like fire, initiates the entire fuze train. The large quantities of primary explosive in the detonator can also be detonated by external stimulus with enough energy to function the entire grenade. These problems are exacerbated when many grenades are in the same location, through sympathetic detonation. This report is a description of heating tests made on inert wax-filled M67 hand grenades and empty M67 hand grenades. The tests were conducted in order to see if grenade halves would separate when heated. Fourteen tests were conducted in all with consistent results. TEST DESCRIPTION The M67 hand grenade was modified to meet requirements of the insensitive munitions program. Instead of making the grenade body in one piece it was made in two pieces as shown in figure 3. The modified body was designed to separate when heated, as in a fire, by internal pressures that would rotate the pieces apart. The Detonator and Sensitivity Laboratory Group of Munitions Engineering Technology Center's Explosives Development Branch, U.S. Army Armament Research, Development and Engineering Center (ARDEC), Picatinny Arsenal, New Jersey was funded to conduct heating tests to see if performance met design goals. Numerous decisions had to be made before the tests could be started. For example: how to heat the item and how fast to heat it, how to collect temperature data, and then how to hold the item while it was being heated. It was decided to collect data using a LabVIEW data acquisition program. The decision was also made to put thermocouples on four spots to get the proper temperature reading of the whole body. Thermocouples were placed on the bottom of the grenade, top of the grenade, middle of the body, and the housing. Figure 3 Modified M67 grenade w/inert M213 fuze Several heating methods were considered: propane torch, electric wire, and Sterno flame. The propane torch method was eliminated because it would require an elaborate test set up and also would be a safety hazard. The flame from a Sterno can was used initially because it was relatively easy to set up the heating arrangement (fig. 4). Two tests were made with the Sterno flame. For these tests, thermocouples were placed on the bottom of the grenade (T1), top of the grenade (T2), fuze top (T3), and Sterno flame (T4).

Figure 4 Sterno can heater TEST RESULTS In the first test, the grenade was suspended over the Sterno can, which was ignited and the grenade was observed to see if it separated while temperature data was logged into the LabVIEW excel spreadsheet. The grenade temperature reached 300 F with an erratic flame temperature, which was probably caused by flame flicker. The grenade did not separate. The second test (fig. 5) used a tin can oven to reduce flame flicker. For this test, a tin can was used to hold the grenade to reduce the flame flicker. Thermocouple locations were changed to the middle, top, fuze top, and then on the Sterno flame. There wasn't much improvement in flame stability with the oven. Data from this test is shown in figures 6 and 7. This method was not chosen as a stable heating method was needed. Figure 5 Sterno heater with can oven

MC7 Grenade Fa*t Hut Sttno 12/1/08 Gr»n«to Bottom Gmda Top fun Top SWmo F)am«560: 160029 160156 160333 160448 160614 160741 160907 161034 161200 1613:26 Figure 6 M67 temperature data, Sterno heater - Gmn*o* IMOto Gr*n»d*Top FuwTop 93307 93600 93853 941 46 944 36 9 47 31 Figure 7 M67 temperature data, Sterno heater w/can oven Insulated AWG 20 nichrome heating wire was on hand and it was decided to use the wire to heat the grenade for the remaining tests. It was a challenge to devise a way to heat the grenade with the wire because of the grenade shape. A mesh pad was first woven to hold and heat the bottom of the grenade (fig. 8). Full power at 120 V was applied to the heater wire, which glowed red and then broke when it reached a temperature of 1300 F. Data from this test is shown in figure 9. Four series represents the thermocouple readings at different locations. Series 4 trace was at the bottom of the grenade, series 3 on the fuze housing, series 2 at the middle of the grenade, and series 1 at the top half of the grenade. Later, a better system was devised by placing the heater wire coiled around the top half of the grenade as shown in figure 10. In the first of these tests, 120 V was applied to the heater. Thermocouples were placed at the fuze housing, heater wire, and two locations on the lower grenade body. Shortly after the test was started, the heater wire emitted sparks and then burned out. The voltage was too high for that size heater. The test did not last long enough to acquire sufficient data.

Figure 8 Mesh pad heater 15 1 5 55 19 2722 15 214a 15 30 14 153141 15 33 0? 15 34 34 15 MOO Figure 9 M67 temperature data, mesh pad heater Figure 10 M67 w/coiled wire heater

For further testing, a resistor was placed in series with the heater wire to reduce power to the wire. Three tests were performed with this method. Temperature data for these tests are shown in figures 11 through 13. Test results were about the same for these tests. The wire insulation first starts to smoke, then the wire glows red and then white, and then starts to burn. Then the wire opens, sometimes accompanied by sparks. The last five tests were controlled with a variable transformer (variac), which gave greater control of the power applied to the heater wire. Figure 14 shows the circuit that was used for these tests. The variac controlled tests lasted longer, but results were similar. The insulation would start to smoke, then the wire would glow red and white, then wax would leak from the grenade seams, and then wax/insulation would burn. Three out of five (first, fourth, and fifth) tests resulted in the fuze threads melting and the grenade separating from the fuze. Temperature data for these tests are shown in figures 15 through 18. M67 Faat Heal Tut 12/12/0» -fe-fcs==^ o;ne 1&27M HMMD ioaee IOM-S IO26«wTtto ia»i7 IO»J«w».si «t KS Figure 11 M67 temperature data, 2 nd test, coiled wire heater, 120 V w/r 1*7 Fail Heat Teal 3, 12/11106 Figure 12 M67 temperature data, 3 rd test, coiled wire heater, 120 V w/r

MC7 Fast Heal Teal 4.12711/06 Fw 4 '07 141*14 14:1M2 141H0 IstMl *1tfle il 141*24 U 1*41 t41ttt 1*30:10 14»» 1*J 3 50 Figure 13 M67 temperature data, 4 test, coiled wire heater, 120 V w/r no./ gq^q o V/4KI«C -a- Hcjret CD Figure 14 Variac heater control circuit MC7 Fast Haat Taat 1.1/5/09 Grtnaoe Bottom e.t QrtraKM Bottom, ail I Fw Body wt ^^> SEt5: 134S07 1»«*9t 134600 114ft2» Figure 15 M67 temperature data, 1 st test w/coiled heater and Variac control

j 1 MS7 FMt Heat Tnt 2. t/w»... </s^ r i \ \ v^ _^ K^ ""* 15 2302 13 24.29 15 25 55 15 27 22 15 28 48 15 30 14 15 31 41 Fuw Botfy. art - Grwrnto Bottom, ait Figure 16 M67 temperature data, 2 test w/coiled heater & Variac control MA7 Fast Heat Test 3,1/5709 18:1328 181410 18 14 53 1815 36 16 1818 1817:02 161748 1618:29 161912 Figure 17 M67 temperature data, 3 rd test w/coiled heater & Variac control M«7 Grenade Faat Heatl. 1/W» \^ Fis«8wfy,«Kt I Gren»de Bottom, e.l I GfWwde Bottom e-i 9? HA 9:2138 8 22 19 92302 92348 924 29 92512 82*56 928:38 9:2722»M» Figure 18 M67 temperature data, 4 th test w/coiled heater and Variac control

One test was conducted using an empty grenade body (no wax or any other inert) to see at what temperature the body separates from the fuze. Figure 19 shows data from the last test. The grenade temperature was slowly heated until the grenade body separated from the fuze. The grenade separated around 690 F. PW7 Slow M T»tt. 1/19/M FunBotfy, «t HNtK Gf«n»d«Bottom «.i - G*vw4i Bottom in( S.OMWXX1 S>«n» Figure 19 M67 temperature data, 5 th test w/coiled heater and Variac control CONCLUSIONS None of the tests resulted in the grenade halves rotating and separating from each other although the grenade separates from the fuze in three of the tests. The first thing that happens after applying power is the heater wire insulation starts to smoke, then the insulation glows, first red then white, then at about 180 F the wax filler melts and starts to leak from the seam in the middle of the grenade, then the insulation and wax starts to burn, and if the power is left on long enough the fuze threads melt at about 690 F and the grenade drops away from the fuze. If too much power is applied, the heater wire opens before the grenade separates from the fuze. The grenade separates from the fuze at approximately 690 F. No recommendations. RECOMMENDATIONS 9

U.S. Army ARDEC ATTN: RDAR-EIK RDAR-AAR-GC RDAR-MEE-W, N. Mehta (7) Picatinny Arsenal, NJ 07806-5000 Defense Technical Information Center (DTIC ATTN: Accessions Division 8725 John J. Kingman Road, Ste 0944 Fort Belvoir, VA 22060-6218 Commander Soldier and Biological/Chemical Command ATTN: AMSSB-CII, Library Aberdeen Proving Ground, MD 21010-5423 Director U.S. Army Research Laboratory ATTN: AMSRL-CI-LP, Technical Library Bldg. 4600 Aberdeen Proving Ground, MD 21005-5066 DISTRIBUTION LIST Chief Benet Weapons Laboratory, WSEC U.S. Army Research, Development and Engineering Command Armament Research, Development and Engineering Center ATTN: RDAR-WSB Watervliet, NY 12189-5000 Director U.S. Army TRADOC Analysis Center-WSMR ATTN: ATRC-WSS-R White Sands Missile Range, NM 88002 Chemical Propulsion Information Agency ATTN: Accessions 10630 Little Patuxent Parkway, Suite 202 Columbia, MD 21044-3204 GIDEP Operations Center P.O. Box 8000 Corona, CA 91718-8000 11