How To Test Laser Power On A Satellite

Similar documents
The Wind Lidar Mission ADM-Aeolus. Recent Science Activities and Status of Instrument Development

h e l p s y o u C O N T R O L

Preface Light Microscopy X-ray Diffraction Methods

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

DIODE PUMPED CRYSTALASER

Qualifying Photonics for the Space Environment

Surface characterization of oxygen deficient SrTiO 3

PROGRESS ON LASER SOURCES FOR DIRCM APPLICATION AT CILAS

STM, LEED and Mass spectrometry

Physics 441/2: Transmission Electron Microscope

Short overview of TEUFEL-project

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

High power picosecond lasers enable higher efficiency solar cells.

Millijoules high master-slave pulse ratio 532 nm picosecond laser

Coating Technology: Evaporation Vs Sputtering

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

8.1 Radio Emission from Solar System objects

Pulsed laser deposition of organic materials

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Experiment 5. Lasers and laser mode structure

Power distribution systems

Designing and Manufacturing Femtoseconds Ultra-broadband Lasers: Proven, Hands-free Reliability

Chapter 4 COATINGS Full Reflective Coatings:

EFFICIENT USE OF SHORT PULSE WIDTH LASER FOR MAXIMUM MATERIAL REMOVAL RATE Paper# M602

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

The CVD diamond booklet

Infrared Viewers. Manual

How To Understand Light And Color

Projects and R&D activities

Fig.1. The DAWN spacecraft

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

ADM-Aeolus pre-launch campaigns with an airborne instrument demonstrator

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Optical Communications

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Exploring the deposition of oxides on silicon for photovoltaic cells by pulsed laser deposition

Micro-Power Generation

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Electromagnetic Radiation (EMR) and Remote Sensing

Single Mode Fiber Lasers

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Lecture 4 Scanning Probe Microscopy (SPM)

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

Amplified High Speed Fiber Photodetectors

- thus, the total number of atoms per second that absorb a photon is

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Large Systems Commissioning

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

UV-NIR LASER BEAM PROFILER

Functionalized optical fiber tips in fused silica and mid-infrared MIR-fibers for spectroscopy and medical application

Photo Modules for PCM Remote Control Systems

Maintenance Management on LMJ H. GRAILLOT, I. GRANET CEA/CESTA/DLP

Solar system studies with the SMA. Arielle MOULLET, Mark GURWELL and the SMA team

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Single Photon Counting Module COUNT -Series

BPW34. Silicon PIN Photodiode VISHAY. Vishay Semiconductors

16th International Toki Conference on Advanced Imaging and Plasma Diagnostics

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Blackbody radiation. Main Laws. Brightness temperature. 1. Concepts of a blackbody and thermodynamical equilibrium.

How to measure absolute pressure using piezoresistive sensing elements

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

DUST EMISSION MONITORING SYSTEM

Chapter 6 Metal Films and Filters

Fiber Optics: Engineering from Global to Nanometer Dimensions

Michalina Góra, Jan Marczak, Antoni Rycyk, Piotr Targowski APPLICATION OF OPTICAL COHERENCE TOMOGRAPHY TO MONITORING OF LASER ABLATION OF VARNISH

ESRF OPTICAL METROLOGY APPLIED TO BENDABLE OPTICAL SURFACES

Introduction to microstructure

INFRARED PARTS MANUAL

Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia

Owner s Manual

Near-field scanning optical microscopy (SNOM)

Advanced Laser Microfabrication in High Volume Manufacturing

Laser Based Micro and Nanoscale Manufacturing and Materials Processing

Residual Gas Analyzers

DIAMOND AVIM Connector

A Study of Haze Generation as Thin Film Materials

Thermal diffusivity and conductivity - an introduction to theory and practice

Beam Energy (GeV) 2 Beam Current (ma) 400 Horizontal Emittance (nm)

UHV Guidelines for X-Ray Beam Transport Systems

Secondary Ion Mass Spectrometry

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Laserbearbeitung von dünnen Schichten auf Rolle-zu-Rolle-Anlagen

Laser-induced modification of metal nanoparticles formed by laser ablation technique in liquids

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm

Lasers Design and Laser Systems

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Corso di Fisica Te T cnica Ambientale Solar Radiation

Raman spectroscopy Lecture

Realization of a UV fisheye hyperspectral camera

Space product assurance

Transcription:

UV LASER-INDUCED HYDROCARBON CONTAMINATION ON SPACE OPTICS Wolfgang Riede, Helmut Schröder German Aerospace Center (DLR e.v.), Institute of Technical Physics, Stuttgart, Germany E-Mail: Wolfgang.Riede@dlr.de Denny Wernham, Adrian Tighe ESA / ESTEC, Noordwijk, The Netherlands SRI Satellite Workshop: Carbon Contamination of Optics July 16 2012

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

DLR Test Center for Space-Based Laser Optics (Vacuum) Laser-Induced Damage Threshold (LIDT) Conversion Efficiency of NLO Crystals Laser-Induced (Molecular) Contamination (LIC) Vibration Tests on Mounted Samples High Energy Proton & Gamma Radiation (External Tests) Thermal Vacuum (External Tests)

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary

Upcoming ESA Earth Observation Missions: ADM / EarthCARE LEO orbit (400 km) LEO orbit (450km) ADM Aeolus satellite* Global measurement of 3-dim. wind (speed) fields Predicted launch: Nov. 2013 Projected lifetime: 36 months, 3 10 9 shots Laser Instrument: ALADIN (Atmospheric Laser Doppler Instrument) Specs:50 Hz, ~100 mj @ 355 nm, XHG LBO, osc. / amp design EarthCARE satellite* Global measurement of vertical profiles of water & aerosols Predicted launch: 2016 Projected lifetime: 36 months, 10 10 shots Laser Instrument: ATLID (Atmospheric LIDAR) Specs: 74 Hz, 30 mj @ 355 nm, XHG LBO, osc. / amp design *Durand et al.; LIDAR technology developments in support of ESA Earth Observer Missions, ICSO 2008

Laser-Induced (Surface) Contamination: General Definition of LIC: Formation of a deposit on the surface of an optical component due to the interaction between the laser beam, the surface of the optic and outgassing species from nearby materials. Affected applications (market): Vacuum operated laser systems (space applications) Pressurized sealed laser systems (military applications) UV lithography Synchrotrons Involved risks: Decrease of optical transmission Reduction of system lifetime System failure (permanent damage)

LIC-Related Standards ECSS-Q-70-01A: Cleanliness and contamination control (2008) Selection based upon low outgassing criteria, RML < 1 % and CVCM < 0,10 % CVCM: Collected Volatile Condensable Material RML: Recovered Mass Loss..for applications around sensitive items (e.g. optics and detectors) more stringent values should be used (bakes on the relevant hardware) ECSS-Q-70-02A: Thermal vacuum outgassing test for the screening of space materials NASA-STD-(I)-6016: Standard materials and processes requirements for spacecraft Materials that are line of sight to contamination sensitive surfaces.. shall have a 0.01 percent CVCM (windows, lenses,.. and other surfaces with highly controlled optical properties)

LIC-Related Standards (2) -> Currently no standard test method for measuring and quantifying laser-induced contamination! -> Recommended CVCM limit is to high! -> Agreed-on test benches & test procedures with ESA / ESTEC

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

LIC Test Bench Principal optical set-up

Multibeam LIC test bench DLR Multibeam ultrahigh vacuum test chamber

Contamination test procedure 1. Vacuum bake-out: Bake-out: 24 hours, 180 C (UHV chamber), dynamic pu mping 2. Blank test: Laser operation (>24 h) under identical conditions as subsequent LIC test (temperature, duration, pressure), but without contaminant inside chamber Success criteria: no deposit on test optic / no transmission loss 3. LIC test: Insertion of weighted test specimen in chamber & system pump down to < 10-5 mbar Laser operation with online monitoring of fluorescence (LIF) Inspection of test optics Determination of mass loss of test specimen

Typical contamination test parameters Wavelength: λ = 1064 nm, 355 nm Pulse width: t = 3 ns / 10 ns Max. rep. Rate: ν = 100 Hz / 1 khz* Beam diameter: d = 300 µm - 3 mm Pulse energy: E = 0.4 3 mj Peak fluence: F = 0.008.2.5 J/cm 2 # shots: N = 10 6 4 10 8 Contaminant pressure: 10-5 mbar Temperature T = 20 100 C Contamination sample & optic * accelerated ageing

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

Monitoring of Molecular Contamination Laser-induced fluorescence (LIF) Imaging Laser Transmission Measurement Residual Gas Analysis (RGA) - Mass Spectrometry Quartz Crystal Micro Balance (QCM) Nomarski Microscopy White Light Interference Microscopy Atomic Force Microscopy Time-of-flight SIMS Cavity Ring Down Spectroscopy In-situ / ex-situ

In-Situ LIF Imaging: Typical Test Set-Up Edge filter Silicone based glue 160 nm Spectral distribution of LIF of deposit

In-Situ LIF Imaging: Dynamic development 1 min 1 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-Situ LIF Imaging: Dynamic development 5 min 5 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-Situ LIF Imaging: Dynamic development 10 min 10 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-Situ LIF Imaging: Dynamic development 25 min 25 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-Situ LIF Imaging: Dynamic development 50 min 50 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-Situ LIF Imaging: Dynamic development 60 min 60 min Doughnut growth Pancake growth Pulsed UV irradiation cw UV irradiation (375 nm UV diode) 2.5 Jcm -2 1.3 x 10 2 Wcm -2

In-situ Transmittance -> Evolution of the ratio between the transmitted and incident energy UV beam splitter Test optics Feed-through with micrometric stage UV beam splitter Dump lens VACUUM CHAMBER Energy meter OUT Energy meter IN 111 Vdc Multimeters 111 Vdc Computer for continuous monitoring

In-Situ LIF Imaging / ex-situ Interferometry Test parameters*: Temperature: 100 C Contaminant: A12 epoxy Pressure: HV Wavelength: 355 nm Zygo height scan Fluorescence distribution Line scan overlay Good spatial correlation (thickness estimation by LIF) Detection sensitivity few nm! Test performed at ESA/ESTEC labs

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

Fluence Effects 0.08 J/cm² 0.5 J/cm² 1 J/cm² 200 µm 200 µm 200 µm White light interference micrographs attained from different fluence values Existence of ablation thresholds 0.12 J/cm² for CV 2566 (silicone based glue) 355 nm, 40 C, 10 Mio. pulses

Substrate Effects Deposit height profiles for MgF 2 and SiO 2 substrates Deposit height profiles for differnent surface roughness values Deposit height is dependent on underlying surface

Environmental Effects Deposit height profile with and without water Deposit height profile for different surface temperatures of target optic Water & heating of target optic is mitigating (but not preventing) LIC

Wavelength Effects 1064 nm 355 nm CV 1152 (Silicone) T = 40 C T = 100 C Solithane 113 (Polyurethane) T = 40 C A12 (Epoxy) T = 100 C no deposit no deposit no deposit no deposit 30 nm > 1000 nm 10 nm > 50 nm Wavelength effects for identical test conditions (1 J/cm², 5 Mio. shots) Deposition in the UV much more severe

Deposition from cw UV laser sources Influence of surface temperature of target optic on deposit growth Sample preparation: Solithane 113 375 nm 220 W/cm² 40 C, 24 hours p < 10-5 mbar cw UV lasers induce deposits

Laser induced contamination under ambient atmosphere Deposit growth / laser fluence 2-dim contour plot of deposit Irradiation parameters: Wavelength: 355 nm Pulse width: 10 ns Peak fluence: 3.1 J/cm² # Shots: 230 Mio. Contamination in air under the presence of silicones

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

Shielding of Optics Shielding will not prevent deposition! Test with Shield Test without Shield Test performed at ESA/ESTEC labs

Material Bake-out Unbaked 7 nm thick deposit No Bake out Baked 1-2 nm thick deposit Bake out 18 h @150ºC Vacuum bake out reduces the outgassing flux and consequently the contamination, but does not prevent LIC Test performed at ESA/ESTEC labs

Prevention of LIC in low pressure O 2 atmosphere 5 Pa O 2 5 Pa 10 Pa O 2 10 Pa 20 Pa O 2 20 Pa LIC test with varying O 2 pressures LIC decreases with increasing O 2 pressure until LIC not detectable >20 Pa O 2 25 Pa Test performed at ESA/ESTEC labs

Prevention of LIC in low pressure O 2 atmosphere But: Oxygen pressure must match the amount of outgassing contaminant flux! (materials bake-out necessary) Test performed at ESA/ESTEC labs

Contents of talk Introduction / Motivation LIC Test Bench / Test Procedure Monitoring / Phenomena Mitigation Summary / Outlook

Summary (General) LIC is a significant risk to the performance of UV lasers (LIDARS) operating on space Available in-situ LIC monitoring techniques have nanometer resolution LIC fluence levels ~ 2 orders of magnitude lower than damage threshold Existence of deposition & ablation thresholds Deposits grow under UV cw laser irradiation Deposits built-up under ambient atmosphere under the presence of silicone based contaminants

Summary (Mitigation & Prevention) Screening of applied outgassing materials (for low deposit formation) Vacuum bake-out of materials used (space conditioning) Operation at low fluence values (~ mj/cm 2 ) Shielding & cold traps Operation under low pressure oxygen (artificial atmosphere) pressure threshold (20 25 Pa O 2 )

Thank you for your attention! Acknowledgements: ESA / ESTEC for continuing project support LZH for cooperation G. Taube / F. Hadinger for technical support

ATLID EarthCare test bench Pressure: < 10-8 mbar Volume: 25 liters Sealing: Copper flanges DLR Ultrahigh vacuum test chamber for long term contamination tests

Motivation: Past / Present Space Laser Missions Instrument (Mission) LITE (Space shuttle STS-64) MOLA 2 (Mars Global Surveyor) GLAS (ICESat) CALIOP (CALIPSO) LALT (SELENE) Wavelengths [nm] / laser specs 1064, (532, 355) 10 Hz / 400 mj Total pulses [Mio] 1.16 / 0.77 Launch Notes Agency 1994 In space performance loss (epoxy contamination) 1064 671 1996 50% decline per year (MOLA 1: on ground silicone contamination) 1064 (532) 40 Hz / 75 mj 1064, 532 20 Hz / 100 mj 1064 1 Hz / 100 mj > 1000 2003 Laser 1: 30% decline per month (In solder contamination) Laser 2: degradation due to photo darkening on SHG Laser 1: 1600 2006 Pressurized, switch to laser 2 after 3 years (leak) (still operating)? 2007 Mission end 2009 (20 Mio. data points) NASA NASA NASA NASA / CNES JAXA

Residual Gas Analysis - Mass Spectrometry Clean chamber

Residual Gas Analysis - Mass Spectrometry Cleanliness control Chamber exposed to Naphtalene

ToF-SIMS MgF 2 Silicone C x H y Mg 3 O 2 F Mg 3 O 3 H Deposition process radially selective 500 µm 10 nm Sample preparation: Silicone based glue 355 nm, 100 Hz, 3 ns 1.5 J/cm² 100 C, 5x10 6 shots AR coated MgF 2 top layers

Periodic Surface Ripples 5.5 µm polarization AFM micrograph 10 7 shots, 355 nm, DP490 (epoxy), 10-4 mbar 2.5 J/cm 2, Quartz window Ripple period: 280 nm Nomarski micrograph 5 000 shots, 1064 nm, Toluene 0.1 mbar 0.22 J/cm 2, BK7 Ripple period: 550 nm Omnipresence of periodic surface ripples in deposit