Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)



Similar documents
OJ L 191, , p. 26. OJ L 2, , p. 1.

Power transformers. Special transformers Railway

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Distribution transformers. Green distribution transformer program Partnership for a sustainable environment

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe

Brochure. Electric generators to power the world

ECODESIGN by FLÄKT WOODS EU REGULATION 1253 AND 1254/2014 FOR RESIDENTIAL AND NON-RESIDENTIAL VENTILATION UNITS

Medium-voltage Transformers

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

A New Framework for the EU EMC Directive

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

The electrical energy produced at the gen

Uninterruptible Power Supply Product Regulations and Standardization in the European Union. By Matteo Tricarico Patents and Regulatory Engineer

Presentation of the France Transfo factories

Estimation of electrical losses in Network Rail Electrification Systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Secondary Unit Substations

DNVGL-CP-0393 Edition December 2015

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

Performance Rating of Room Fan- Coils

Guideline for Energy Efficient Electrical systems for building. Presentation by TERI

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

CE Marking and Technical Standardisation

WINDING RESISTANCE TESTING

Transformers. Special transformers Reactors products

Intertek Testing Services 70 Codman Hill Road Boxborough, MA WORLD LAB

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Brochure Introducing HVDC

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

DS1 Diode-based transient-free capacitor switch

DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit Ann Arbor Mt. Clemens Port Huron

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Earth Fault Detection Basics in Theory

Medium voltage product. Instrument transformers for indoor applications Product overview

A project to optimise quality and energy efficiency must include metering

ABB PSPS Erich Steinmann; Generator control-2013

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Offshore Platform Powered With New Electrical Motor Drive System

Product Data Bulletin

EssPro Energy Storage Grid Substation The power to control energy

Ellipse The Enterprise Asset Management (EAM) solution for asset intensive industries

Standard Recovery Diodes (Hockey PUK), 2100 A

United Arab Emirates Helping to build the future

Power transformers. Phase shifting transformers Reliable and efficient power flow control

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels

Hybrid shunter locomotive

SECTION DVD01: VOLTAGE DROP/VOLTAGE FLICKER AND TRANSFORMER SIZING GUIDELINES

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

WE-LF SMD Common Mode Power Line Choke

INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Alternative data center power

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Transformer Calculations

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SECTION DRY-TYPE TRANSFORMERS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Using Current Transformers with the 78M661x

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

ABB central inverters PVS to 1000 kw

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

Type SA-1 Generator Differential Relay

Voltage Regulator SPAU 341 C. Product Guide

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Unified requirements for systems with voltages above 1 kv up to 15 kv

COMMISSION REGULATION (EU)

EEL303: Power Engineering I - Tutorial 4

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Electrical Predictive and Preventative Maintenance

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

INTERNATIONAL STANDARD

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

AC Electric Motors best practice

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

How the efficiency of induction motor is measured?

Transcription:

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

2 European MEPS for transformers

The EU MEPS (European Minimum Energy Performance Standard) Transformers have been identified as one of the ERP priority groups with considerable energy saving potential. Within 28 member states of the European Union the total losses originating from an existing fleet of transformers amounts to approximately 100 TWh annually. This corresponds 40 Mt of CO 2 emissions. Introduction The EU MEPS (European Minimum Energy Performance Standard) sets a mandatory minimum efficiency level for transformers introduced into European market. The EcoDesign Directive 2009/125/EC of the European Parliament establishes a framework to set Ecodesign requirements for energy-related products (ERPs). Transformers have been identified as one of the ERP priority groups with considerable energy saving potential. Within EU28 the total losses originating from an existing fleet of transformers amounts to approximately 100 TWh annually. This corresponds 40 Mt of CO 2 emissions. For implementing the directive with regard to transformers, the European Commission has set as a legal framework the regulation No 548/2014 which states the minimum efficiency levels of transformers. The aim of the regulation is to prevent non-efficient products from being placed into the European market. The regulation is binding in it s entirety and directly applicable in all EU28 1. 1 Countries of the European Economic Area (Norway, Iceland, Liechtenstein) have committed to implement the same or very similar minimum efficiency standards set by EU Ecodesign regulations through national legislation. Other closely associated countries like Switzerland have in the past also transposed EU Ecodesign requirements. European MEPS for transformers 3

4 European MEPS for transformers

Scope EU MEPS covers both, dry-type and liquid-filled distribution transformers as well as power transformers with a minimum power rating of 1 kva used in electricity transmission and distribution networks or in industrial applications. There are some special installations and applications of transformers that are exempted from the regulation. Transformers specifically designed and used in applications such as the following are excluded: instrument transformers, specifically designed to supply measuring instruments, meters, relays and other similar apparatus, transformers with low-voltage windings specifically designed for use with rectifiers to provide a DC supply, transformers specifically designed to be directly connected to a furnace, transformers specifically designed for offshore applications and floating offshore applications, transformers specially designed for emergency installations, transformers and auto-transformers specifically designed for railway feeding systems, earthing or grounding transformers, this is, three-phase transformers intended to provide a neutral point for system grounding purposes, traction transformers mounted on rolling stock, this is, transformers connected to an AC or DC contact line, directly or through a converter, used in fixed installations of railway applications, starting transformers, specifically designed for starting three-phase induction motors so as to eliminate supply voltage dips, testing transformers, specifically designed to be used in a circuit to produce a specific voltage or current for theźpurpose of testing electrical equipment, welding transformers, specifically designed for use in arc welding equipment or resistance welding equipment, transformers specifically designed for explosion-proof and underground mining applications, transformers specifically designed for deep water (submerged) applications, medium voltage (MV) to medium voltage (MV) interface transformers up to 5 MVA, large power transformers where it is demonstrated that for a particular application, technically feasible alternatives are not available to meet the minimum efficiency requirements set out by this Regulation, large power transformers which are like for like replacements in the same physical location/installation for existing large power transformers, where this replacement cannot be achieved without entailing disproportionate costs associated to their transportation and/or installation. European MEPS for transformers 5

Frequently asked questions Are manufacturers allowed to produce transformers with lower efficiency than required in the regulation? Transformers not compliant with the regulation may no longer be placed in the European market (EU28-countries and Iceland, Liechtenstein, Norway) as of July 1, 2015. Switzerland is expected to adopt the same requirements. By then all new transformers need to meet the Tier 1 minimum efficiency requirements of the regulation (except the specific special transformers / installations which are exempted from the regulation). However, the regulations do not apply outside Europe. Therefore, it will be possible for manufacturers in Europe to produce low efficiency transformers with high energy losses for markets that do not have minimum efficiency requirements. Do I, as a customer, have to specify in my inquiry documents that the transformer needs to meet the minimum efficiency requirements? No, this is not necessary. It is primarily the manufacturer s responsibility to ensure that the transformers are compliant with the regulation. Producing or importing a non-compliant transformer into European market is illegal beginning July 1, 2015. However, especially during the transition period, it may be recommended to make reference to the regulation as the minimum required efficiency level. Is there a tolerance for exceeding the MEPS values? No, there is no tolerance. If the loss values exceed the requirements of the regulation, the transformer is considered to be non-compliant and thus cannot be delivered to the European market. For the verification measurements conducted by the surveillance authorities, there is a 5 percent tolerance. However, this tolerance shall not be used by the manufacturer of importer as an allowed tolerance. How can I be sure that a transformer is compliant? All the transformers will have to bear a CE-marking as a sign of compliancy with the prevailing directives. An easy way to verify the compliancy is by checking whether the transformer has the appropriate marking on the main rating plate. The manufacturers will also have a responsibility of making a duly signed EC Declaration of Conformity document available. As a customer, I have been utilizing capitalization values for the transformer losses in my inquiry and tender evaluations. Should I continue to do so despite the regulation? Yes, you should continue to do so. The regulation is only for setting a minimum floor level for the transformer efficiency. Total Cost of Ownership method (TCO) is used to minimize the investment required to obtain the greatest energy savings for the least cost. This results in the selection of transformers whose losses are economically optimal for the given need / case. The regulation will only define a constraint for the losses. The manufacturer should provide an offer with optimized loss 6 European MEPS for transformers

The transition period from the regulation coming into force (June 2014) until July 1, 2015 is effectively acting as a grace period allowing the industry and the market to adapt. values that may be lower than the maximum value defined by the regulation. Is it possible to procure transformers now that meet the Tier 2 requirements scheduled to become mandatory July 1, 2021? Yes it is. A customer may make reference to the Tier 2 -level of the regulation in his inquiry. ABB can produce products today that meet Tier 2 requirements as well as products with efficiencies beyond future minimum levels. However, when talking about the Tier-2 -levels, it should be noted that the European Commission will conduct a midterm assessment for the regulation latest during the year 2017 where Tier-2 requirement levels will be reviewed and may be amended. Is there a grace period after July 1, 2015? No. In fact the transition period from the regulation coming into force (June 2014) until July 1, 2015 is effectively acting as a grace period allowing until the industry and the market to adapt. European MEPS for transformers 7

ABB transformer solutions available today Timeline October 21, 2009 EU adopted revised Ecodesign Directive (2009/125/EC) for Energy-related products establishing a framework to be complemented by implementing measures (E.Q. regulations on individual products and systems) June 11, 2014 EU commission adopted a regulation to apply the defined Ecodesign requirements on transformers and the regulation 548/2014 entered into force July 1, 2015 Transformers need to be compliant with the efficiency requirements of Tier 1 level of the regulation 2017 Mid-term assessment of the regulation by the European Commission July 1, 2021 Transformers need to be compliant with the efficiency requirements of Tier 2 level of the regulation Efficiency requirements and classes Main structure Oil distribution transformers (up to 3.15MVA, HV 24KV, LV 1.1KV) maximum losses level defined Pole-mounted oil distribution transformers (160-315KVA) maximum losses level defined Oil distribution transformers (3.15 40MVA up to 36KV) minimum PEI value defined Dry transformers (up to 3.15MVA, HV 24KV, LV 1.1KV) maximum losses level defined Dry transformers (3.15 40MVA up to 36KV) minimum PEI value defined Power transformers minimum PEI value defined Transformers with rating up to 3150 kva and nominal voltage up to and including 36 kv The maximum allowed loss levels for transformers with ratings up to and including 3150 kva are based on the classification of the EN standards 50464-1:2007 and 50541-1:2011. Note: These EN standards are currently being united and revised to support the regulation more directly. Lower efficiency classes than in the EU MEPS will disappear completely. Liquid-filled distribution transformers with one winding with Um<=24 kv and other one with U 1,1 kv, Tier 1 Tier 2 25 1000 kva Ck, A0 Ak, A0-10% 1001 3150 kva Bk, A0 Ak, A0-10% Pole-mounted transformers (note: must bear a sign For pole-mounted operations only ) Tier 1 Tier 2 25 159 kva Ck, A0 Bk, A0 160 kva Ck+32%,C0 Ck+32%,C0-10% 161 315 kva Ck, A0 Bk, A0 Dry-type transformers with one winding with Um 24 kv and other one with U 1,1 kv, Tier 1 Tier 2 25 630 kva Bk, A0 Ak, A0-10% 631 3150 kva Ak, A0 Ak, A0 Timeline October 21, 2009 June 11, 2014 July 1, 2015 2017 July 1, 2021 EU adopted revised Ecodesign Directive (2009/125/EC) for Energy-related products establishing a framework to be complemented by implementing measures (E.Q. regulations on individual products and systems) EU commission adopted a regulation to apply the defined ecodesing requirements on transformers and the regulation 548/2014 entered into force Transformers need to be compliant with the efficiency requirements of Tier 1 level of the regulation Mid-term assessment of the regulation by the European Commission Transformers need to be compliant with the efficiency requirements of Tier 2 level of the regulation 8 European MEPS for transformers

Concessions for transformers with voltages differing from the above defined Ref Insulation level Correction of load lossses and no load losses 1 One winding with U m 24 kv and the other with U m > 1.1 kv Maximum levels of losses indicated in tables can be increased by 10% for no load losses and by 10% for load losses 2 One winding with 24 kv < U m 24 kv and the other with U m > 1.1 kv Maximum levels of losses indicated in tables can be increased by 15% for no load losses and by 10% for load losses 3 One winding with 24 kv < U m 36 kv and the other with U m > 1.1 kv Maximum levels of losses indicated in tables can be increased by 20% for no load losses and by 15% for load losses The regulation defines also concession for transformers with dual voltage windings. Transformers with rating >3150 kva and/or nominal voltage >36 kv For the transformers with higher rating than 3150 kva, an index called Peak Efficiency Index (PEI) is introduced. The methodology for calculating the PEI is based on the ratio of the transmitted apparent power of a transformer minus the electrical losses to the transmitted apparent power of the transformers: PEI = 1 2(P +P ) 0 c0 P 0 +P S c0 r P k P 0 is the no load losses measure at rated voltage and rated frequency, on the rated tap P c0 is the electrical power required by the cooling system for no load operation P k is the measured load loss at rated current and rated frequency on the rated tap corrected to the reference temperature S r is the rated power of the transformer or autotransformer on which Pk is based PEI represents a highest value of efficiency index that can be achieved at the optimum value of loading factor. European MEPS for transformers 9

The regulation lists minimum allowed values of peak efficiency index for dry type transformers up to 10000 kva and for liquid- -filled transformers up to indefinite rating. Example (Liquid-filled transformer): Tier 1 Tier 2 25 MVA 99,657 99.700 Markings and documentation Beginning July 1, 2015, the following product information requirements for transformers not exempted from the scope of the regulation must be shown on the rating plate in addition to the EN 60076-1 requirements: The values and the name of the classes of no load loss and load loss for transformers 3150 kva For transformers > 3150 kva the PEI Information on the weight of all the main components of a transformer (including at least the conductor, the nature of the conductor and the core material) For pole mounted transformers, a visible display plate For pole-mounted operation only In addition EU MEPS lists information that has to be shown in transformers documentation. ABB and EU MEPS ABB has been in the energy business for 130 years and offers a full range of transformer products compliant with the requirements available. Our technologies are used along the entire energy value chain in both the utility and the industrial sectors. ABB enables customers to maximize the value of energy used to improve their competitiveness while reducing environmental impact and enhancing sustainability. Solutions from ABB can help customers achieve: Reduced energy costs Reduced greenhouse gas emissions Reduced need for additional generating capacity Energy efficiency improvements can also provide additional operational benefits, such as improved productivity, improved quality, and reduced maintenance burdens. A sample rating plate compliant with the new requirements As the world market and technology leader in the transformer industry, ABB is committed to support customers with transformer solutions that enhance sustainability. Energy efficiency is one of the major drivers of our research and development activity. Today ABB is able to offer transformers with efficiency levels beyond the second level ( Tier 2 ) of the European regulation scheduled for the year 2021. The regulation list maximum allowed losses or minimum allowed values of peak efficiency index for dry type transformers up to 10000 kva and for liquid-filled transformers up to indefinite rating. 10 European MEPS for transformers

European MEPS for transformers 11

Contact us ABB Ltd. Affolternstrasse, 44 P.O. Box 8131 8050 Zurich, Switzerland www.abb.com/transformers Note The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the information, products, services, or related graphics contained in the document for any purpose. Any reliance placed on such information is therefore strictly at your own risk. ABB reserves the right to discontinue any product or service at any time. 1LAB 000572 Copyright 2014 ABB All rights reserved