Etap Safety Manager. Your emergency lighting under control: anywhere, anytime



Similar documents
Etap Safety Manager. Your emergency lighting under control: anywhere, anytime

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

AXIS 262+ Network Video Recorder

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

BabyWare Imperial PC Software

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Network Projector Operation Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

CMS Central Monitoring System

Targus USB Port Adapter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Wired / Wireless / PoE. CMOS Internet Camera ICA-107 / ICA-107W / ICA-107P. Quick Installation Guide

PM1122 INT DIGITAL INTERFACE REMOTE

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

F453. TiF453. User guide 10/11-01 PC

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Infinity C Reference Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

DIGICLIENT 8.0 Remote Agent Software

QUICK INSTALLATION GUIDE. VEBAR Battman Monitoring Software

SA-9600 Surface Area Software Manual

SNC-VL10P Video Network Camera

smart-house Web-Server Manual smart-house Web-Server Manual Version 1.03

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

User Guide for Windows 10

Access control designed simply for you

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

Setting Up Novell Small Business Suite

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

P-660HW-Tx v g Wireless ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v3.70 Edition 1, 2/2009

Current Monitoring Kit

User guide for NANOSTATION 2

User Manual V1.0. Remote Software

IXP120 Alarm Monitor Utility

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

EasyMP Monitor Operation Guide Ver.4.40

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

TYLER JUNIOR COLLEGE School of Continuing Studies 1530 SSW Loop 323 Tyler, TX

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Ethernet Radio Configuration Guide

P-660HNU-Tx. Wireless N ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.02 Edition 1, 11/2011. IP Address:

WUA Mbps Wireless USB Network Adapter

Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW

SecureLinx Spider Duo Quick Start Guide

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

EasyMP Monitor Operation Guide Ver.4.50

EasyMP Monitor Operation Guide Ver.4.53

Current Monitoring Kit QUICK START GUIDE

LOREX CLIENT 2.2 Integrated Remote Agent Software

Westell VERSALINK GATEWAY (MODEL 327W) Quick Start Guide Rev. A May 2004

SOFTWARE INSTALLATION INSTRUCTIONS

VENTIsupport Version 1

Fiery E100 Color Server. Welcome

Version User Manual. USB 3.0 to Gigabit Ethernet Adapter DUB-1312

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

User Guide HUAWEI UML397. Welcome to HUAWEI

Quick Installation Guide DSL-2640U. Wireless N 150 ADSL2+ Modem Router

R60 USB to CAN interface Manual (1.5 EN)

EW7031/EW7032-2,5 SATA/eSATA Hard Disk Enclosure

TrueAlarm Fire Alarm Systems

TMA Management Suite. For EAD and TDM products. ABOUT OneAccess. Value-Adding Software Licenses TMA

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini

Cisco 831 Router and Cisco SOHO 91 Router Cabling and Setup Quick Start Guide

Substation Monitoring System SMS 510. Product Guide

AXIS 211A Network Camera

Wireless Internet Camera

2100 POS System User Guide

RS-232/422/485, Power over Ethernet

VTO6xxx. IP door stations. User manual

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

Temperature & Humidity SMS Alert Controller

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

Network Camera. Quick Operation Guide V4.0.1

Guide for wireless environments

Chapter 5 Cubix XP4 Blade Server

Emerson Smart Firewall

Setup guide. point to point wall plate extenders

1 DVR 670 Series firmware version (date )

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Installing an Omnicast System Omnicast version 3.5

Connecting to the Internet

Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Amcrest 960H DVR Quick Start Guide

Wireless LAN g USB Adapter

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Disturbance Recoder SPCR 8C27. Product Guide

User manual Compact Web PLC WP240 series IEC-line

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

P-660HWP-Dx. Quick Start Guide g HomePlug AV ADSL2+ Gateway. Version /2007 Edition 1. Copyright All rights reserved.

How To Use An Easymp Network Projection Software On A Projector On A Computer Or Computer

Transcription:

Etap Safety Manager Your emergency lighting under control: anywhere, anytime

Efficiently manage your emergency lighting Safety Manager () is a management system that assists you with the monitoring, configuration and maintenance of your emergency lighting. For this purpose, each device connected to your network is allocated a unique code. This allows to easily identify each luminaire and to automatically report if each luminaire is functioning properly. You can choose a wired or a wireless network, or a combination of both. With you manage not only your self-contained and central battery emergency lighting luminaires, but also any emergency units or K9 LED emergency modules that are integrated with the luminaires. You can connect your network to the internet, to have complete access from anywhere on the world wide web at any time. 2 Dashboard - Lighting - Microsoft Internet Explorer File Edit View Favorites Tools Help Back Search Favorites Standby mode Sign off James Smith Go to Links Go to Links can manage all different sorts of emergency lighting: - self-contained emergency lighting luminaires - central battery emergency lighting luminaires - lighting luminaires with K9 LED emergency module - lighting luminaires with emergency unit Notifications (1) Go to Links Confirmed notifications (0) Running duration tests (0) Go to Done Go to Done Go to Done The window colours give you immediate recognition of the status of the luminaire s functionality.

Internet network Central emergency supply web controller 3 EBS Advantageous in all respects You get extra safety. You save money and time by efficiently managing your emergency lighting, anywhere, anytime in line with the EN50172. You have a multitude of options: a versatile solution for any building or system configuration. is a user friendly system. grows flexibly along with your needs. You are in good company: has for years proved its quality and stability at hundreds of companies throughout Europe.

You get extra safety first of all guarantees superior safety. You can see in a glance if all of your emergency luminaires are functioning properly. The software will warn you as soon as safety is no longer ensured. You can not only monitor but also actively manage your emergency lighting system from any location. You can yourself easily set the test moment, switch a maintained luminaire or start a interim test or set luminaires in rest mode. That way, you: - comply with the IEC62034 standard, which stipulates that luminaires in a single room should not be tested simultaneously. - prevent tests from being conducted at inconvenient moments - prevent all luminaires from malfunctioning simultaneously during a planned power outage, simply by setting your luminaires in rest mode. In the event that communication with the network fails, you also receive a fault message. In the meantime your emergency luminaires continue to work fully independently, including the built-in self-test. Show Logbook Code Serial number Descripton Mode Type Lamp K1_HSL004 K1_HSL005 K1_HSL006 000122 001234 000002 Showroom 1, auditorium door Showroom 2, staircase Lobby, outside door Logbook according to EN50172. You save time and money 4 According to European standard EN50172, you are required to regularly check all your emergency lighting systems to ensure safety in the event of a power failure. All these checks must be entered in a log book: a time-consuming activity, especially in the case of a large installation. does all this work for you by storing all required data. For each luminaire you can at all times call up the history and the current status, or print out a log with all necessary information on checks and maintenance activities. Fault messages contain all the information you need to remedy them immediately: location on a map or picture, type of luminaire, description of the defect, required spare parts. This enables you to intervene quickly and effectively at all times. Another time-saving feature. Maintenance report with detailed location information. For preventive maintenance purposes, you can retrieve detailed information about the self-contained luminaires on the number of burning hours of the lamp and the duration of the battery. Lamp Lamp code: OLFT006/011 Battery Battery code: Far-off buildings can be easily controlled and managed from any PC on the internet. You no longer need to designate an emergency lighting manager for each building. Based on the service report, you collect the necessary replacement parts for the maintenance work in advance. The complete emergency lighting system can be serviced in a single visit. Lamp: Switch off Switch settings Battery duration: 20 minutes Lamp function time: 5658 hours Last replacement: Last replacement: 2009-04-15 Register battery replacement Register lamp replacement Mode: Detailed luminaire information for efficient preventive maintenance.

Internet network Corporate network building management system 5 You have a multitude of options With you manage not only your self-contained and central battery luminaires, but also the emergency units that you want us to integrate with your luminaires. Self-contained emergency lighting luminaries: wireless or wired For self-contained emergency lighting within a single building, you can choose a wired or wireless solution, or a combination of both. An existing network can easily be extended with a wired or wireless network. Remote management Is your system spread over a number of buildings? In that case too, you can fully manage it from any PC. You can manage sites on all locations by the internet. You can use the local network to remotely manage your emergency lighting. The luminaires are connected via the corporate network with a com.server to the web controller. This reduces the bus wiring to a minimum. You can also connect to your building management system. Through an open interface you can give instructions to or gather information from the web controller. For a detailed representation of the status of your luminaires, you can integrate a detailed daily updated export file or make a direct connection with the web controller. Or you integrate by having a volt-free contact directly report any problems with one of your luminaires. All details are shown on your PC.

is a user friendly system Safety Manager is easy to install and to use. It adapts easily to the structure of your building(s), also if it is changed later. Search Sign off James Smith Easy start-up All you have to do is logically structure the luminaires in a list that reflects the structure of your building. Once your network has been set up, your software automatically detects all luminaires. An expert will help you successfully complete the start-up process. Search location Search Malle Main Building Ground Floor Auditorium 1 User friendly interface For searching a luminaire you directly navigate through the images and maps of your building. only shows the relevant information and actions that are possible in a specific context. In 2 clicks gives you the necessary information to solve a failure. The system can send a mail to preset e-mail addresses, daily or in the event of an error report. Because of the layered interface, the user friendly approach and the clear visual feedback, is easy to learn and to use. Overview - Malle, Main Building, Ground Floor, Auditorium 1 Code Serial number Description Type Mode Lamp Tests 1MB GF A1 1 017AOC Auditorium1, front door 1MB GF A1 2 017AOD Luminairies can easily be located on images or maps of your building. Auditorium 1, showroom door 6 grows along with your needs Flexibility in your network With your emergency lighting system can be quickly adapted or extended. In a wired network, you can interconnect the luminaires at random. To extend your installation with wireless luminaires, you can connect the interface for wireless communication (a coordinator ) anywhere in your wired network. The perfect solution when renovating buildings In the case of new buildings, you choose a wired or wireless network, depending on the acquisition and installation costs and the desired flexibility. For renovations, the installation of the communication wiring is often less feasible from a financial or aesthetic point of view. Wireless then provides the ideal solution.

You are in good company Our many years of experience in emergency lighting and in Safety Manager is your best guarantee for quality and stability. Over Europe, several hundred systems daily prove their worth and effectiveness. The list of companies that have chosen is too long to publish here. The following list will, however, give you an idea. As you can see, you are in good company. 7 Belgium Eurostation (Antwerp) Justitiepaleis (Brussels) Procter & Gamble (Brussels) St Jan Hospital (Bruges) France AXA (Paris) Banque de France (Paris) Hotel Auserlitz (Paris) Radio France (Paris) Portugal Autoeuropa (Lisbon) Norfin Office Park - Campus de Justiça de Lisboa (Lisbon) Túnel do Rossio (Lisbon) Laboratório Regional Veterinária e Qualidade Alimentar (Funchal) Germany Bayer AG (Leverkusen) MAN (Augsburg) Deutsche Rentenversicherung (Berlin) Continental Teves (Theinböllen) Spain Ahorro Corporación (Madrid) Coca-Cola (Madrid) TYPSA (Madrid) CESCE (Madrid) Luxembourg Luxairport (Luxembourg) Bil Dexia (Luxembourg) Ecole de Bacharage (Bacharage) the Netherlands Carré (Amsterdam) ING (Amsterdam) Schiphol (Amsterdam) TU Delft (Delft) Sweden Gränby Centrum (Uppsala) Äldreboende Ljung (Värmdö) Mobilia köpcenter (Malmö) UK Langley School (Langley) Sainsbury (London) Renfew Council (Paisley)

Safety Manager Efficient management over the internet Extra safety You save time and money Perfect tool to comply with EN50172 Suitable for any building configuration or system configuration Easy to expand and adjust - Easy to start up - User friendly interface - Flexibility in your network - For renovation projects and new buildings Quality and stability 09/09 8024948-008E/0 The information is provided for guidances only and we reserve the right to change details, as the result of technical development, without prior notice. Lighting, U.K. Branch Unit 6 Windsor Business Centre Vansittart Estate Windsor Berkshire SL4 1SE Tel. +44 (0)1753 829970 Fax +44 (0)1753 859208 e-mail: enquiries@etaplighting.com www.etaplighting.com

(2 luminaires to repair) (1 luminaire to repair) or message Action ery error Change the battery VK1S125 and register the battery replacement via the Command menu. Send the luminaire to if the problem lasts. Date: Signature: r Change the lamp - and register the lamp replacement via the Command menu Date: Signature: Send the luminaire to E D t Application Components Advantages Safety Manager Central managing and control systems Application Program for monitoring, control, reporting and maintenance of self-contained emergency lighting systems with: - self-contained emergency lighting luminaires - Luminaires with K9 LED module - Luminaires with emergency unit* - centrally supplied luminaires connected to EBS ( Battery System) - Emergency lighting with wired or wireless communication - EBS systems and luminaires - web controller (for web TM ) or a PC with software (for windows based)** - Wired network - Optional: - Emergency Unit Gateway (EUG) for communication with lighting luminaries fitted with an emergency unit - coordinator for communication with emergency lighting luminaires equipped for wireless communication - COM server for multi-building systems connected to the local network (LAN) - Remote Access for access to the software of each PC connected to the company network - possibility of connecting an RS 232 driver (line driver) with cable for multibuilding systems not connected to a local network - volt-free contact module for transmission of errors to central control panel or building management system - - EBS coupling module for the communication with EBS via LAN or USB - Follow-up of combined systems (self-contained and centrally supplied emergency lighting systems) - Automatic logging test results and maintenance of log book in accordance with EN 50172 - Low-cost precautionary maintenance through visualisation of lamp burning hours and battery duration - Field-proven system: several hundred systems installed - Control of self-contained emergency lighting luminaires via internet * for an overview of suitable types, consult ** see system function comparison, p. 9 3

SYSTEM FEATURES Piazza, Eindhoven - The Netherlands Luminaire - messages Software commands (individual/group/installation) Software - overview System External connections Luminaire errors: lamp, battery, electronics Network problem: communication or radio communication problem Luminaire: identification data of self-contained luminaires Remote switching of the maintained lamp (manual/periodic automatic) Adjustable test moment Search function Activate/deactivate rest mode (only for wired) Manual test function System status current operating mode (standby/test/rest/emergency), lamp status, test settings (moment/cycle), lamp burning hours (only self-contained luminaries), battery duration (luminaires via Emergency Unit Gateway and EBS systems only indicate whether the specified duration has been met) Error messages: lamp, battery, electronics, network communication error Maintenance: maintenance orders and information on luminaire, lamp and battery Statistics: status report, history System reports: installation report, test settings, status report, maintenance report (in accordance with EN 50172) Automatic export of status information (ASCII) Alarm signalling via potential free contact module Automatic fault signalling via e-mail Access via a PC with an internet or network connection web TM SYSTEM 1. emergency luminaires K1, K2, K3, K5*, K6, K7, K9*, KB, KL self-contained luminaires luminaires with K9 LED module* luminaires with emergency unit* * recessed luminaires not wireless see productpages consult 2. web controller (maximum 1 BUS per web controller) web controller Material Dimensions B x D x H Mounting Hardware aluminium 170 x 120 x 35 DIN rail 'solid state' memory / power supply: 230V, 0,7A max / Possible connections: Ethernet connector 10/100 LAN (RJ45), BUS-adapter connection web controller Licence extra luminaires Amount of luminaires: up to 100 up to 200 up to 300 up to 400 up to 500 per 50 KH16-100 KH16-200 KH16-300 KH16-400 KH16-500 KH-50 3. Network a. Wired network with emergency lighting luminaires (maximum 500 luminaires per BUS) BUS-power supply BUS-adapter BUS network dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting reach: maximum distance between furthest points: 0.66 km with 0.5 mm 2 wire; 1.8 km with 1.5 mm 2 wire; 2.7 km with 2.5 mm 2 wire / resistance BUS power supply to utmost terminals: 50 Ohm / power: 3 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / reach: in accordance with RS232 specifications / PC connection: RS232 COM port / power: 1 W type: 2-core twisted pair (0.5 2.5 mm 2 ) / total length: maximum 6 km (maximum capacity: 1 µf) / topology: free K4H12 K4H16 4 WWW.LIGHTING.COM

b. Wired network for lighting luminaires with emergency units (maximum 64 luminaires per segment) EUG-power supply Emergency Unit Gateway (EUG) Wiring Emergency unit dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / maximum reach: 200 m / power: 6 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / power: 3 W type: 2-core (0.5-1.5 mm 2 ) / total length: maximum 300 m with 1.5 mm 2 ; maximum resistance 8 Ohm luminaires with emergency unit KH7 KH6 consult BUS-segment with interior lighting with emergency unit c. Wireless network with emergency lighting luminaires Coordinator dimensions (w x h x d in mm): 160 x 130 x 60 / 2.4 GHz / 16 channels / communication based on IEEE 802.15.4 / transmission power: 1 mw / to connect to the BUS 4. Connection with web controller KH12 wireless network with emergency lighting luminaires PC with network connection and web browser a. Direct aan de PC Network cable crossed network cable network cable b. Via corporate network CORPORATE NETWORK Corporate Network Connection to web controller via network cable c. Via Internet World Wide Web Connection to web controller via network cable WORLD WIDE WEB 5

windows based SYSTEM 1. self-contained emergency luminaires K1, K2, K3, K5*, K6, K9, KB K1, K2, K3, K5*, K6, K9, KB self-contained luminaires with EBS-systems: Static Dynamic Light Group luminaires with LED module luminaires with emergency unit * not wireless see productpages see productpages consult Centralised monitoring and remote control with 2. Safety Manager software Delivered on CD-ROM / assistance with set-up and start-up of the installation / protection on several password levels / integrated manual in English PC processor: minimum Pentium II - 266 MHz / OS: Windows 2000 or more recent / RAM: minimum 64 MB / HD: minimum 400 MB / video RAM: S-VGA - 1 MB / screen: VGA 640x480 / mouse / CD reader / RS232 COM port (minimum 1 ) Windows XP and 2000: login as administrator required for installation; login as main user sufficient for use 3. Network (maximum 8000 luminaires, maximum 12 COM ports per system) KH3-E a. Wired BUS network with emergency lighting luminaries (maximum 500 luminaires per BUS) BUS-power supply dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting reach: maximum distance between furthest points: 0.66 km with 0.5 mm 2 wire; 1.8 km with 1.5 mm 2 wire; 2.7 km with 2.5 mm 2 wire / resistance BUS power supply to utmost terminals: 50 Ohm / power: 3 W K4H12 BUS-adapter incl. RS232 cable 8 m dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / reach: in accordance with RS232 specifications / PC connection: RS232 COM port / power: 1 W K4H16 BUS network -EBS coupling module via USB type: 2-core twisted pair (0.5 2.5 mm 2 ) / total length: maximum 6 km (maximum capacity: 1 µf) / topology: free for coupling an EBS ( Battery Systems) centralised system via USB (hardware, software, user-id) KH14 -EBS coupling module via LAN for coupling an EBS centralised system via LAN (hardware, software, user-id) KH15 b. BUS segment for interior lighting with emergency units (maximum 64 luminaires per segment) BUS-segment with interior lighting with emergency unit BUS power supply Emergency Unit Gateway (EUG) Wiring Emergency unit dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / maximum reach: 200 m / power: 6 W dimensions (w x h x d in mm): 90 x 60 x 75 / DIN-rail mounting / power: 3 W type: 2-core (0.5-1.5 mm 2 ) / total length: maximum 300 m with 1.5 mm 2 ; maximum resistance 8 Ohm luminaires with emergency unit KH7 KH6 consult Wireless network with emergency lighting luminaires c. Wireless network with emergency lighting luminaires Coordinator dimensions (w x h x d in mm): 160 x 130 x 60 / 2.4 GHz / 16 channels / communication based on IEEE 802.15.4 / transmission power: 1 mw / to connect to the BUS KH12 6 WWW.LIGHTING.COM

4. Connection with network in other buildings a. Via corporate network EXTRA COMPONENTS MAIN BUILDING Remote Access licence code Corporate Network 1 licence key needed per software package internal computer network KH3-RA-E CORPORATE NETWORK BUS network BUS connected via a local network (LAN) b. Via a local network (LAN) (1 PC port per LAN connection) EXTRA COMPONENTS PER ANNEX BUILDING COM-server PC and COM server driver to be configured by the local network (LAN) administrator Local Area ethernet Network (LAN) KH11 PC BUS network BUS connected via a local network (LAN) c. Via een specifieke Fixed Line over RS232 driver (line driver) (voor gebouwen niet voorzien van een LAN-verbinding) EXTRA COMPONENTS MAIN BUILDING RS232 driver depending on requirements of RS232 driver / 1 per annex building consult EXTRA COMPONENTS PER ANNEX BUILDING RS232 driver depending on requirements Wiring depending on requirements of RS232 driver (line driver) consult PC BUS network BUS connected via RS232 driver (line driver) 7

Technische Universiteit, Delft The Netherlands 8 WWW.LIGHTING.COM

VERSION COMPARISON VERSION COMPARISON: web TM versus windows based Search Sign off James Smith Search location Search Malle Main Building Ground Floor Auditorium 1 web TM windows based Maximum number of luminaires per system 500 8000 Access Local Via company network Via Internet Overview - Malle, Main Building, Ground Floor, Auditorium 1 Code Serial number Description Type Mode Lamp Tests 1MB GF A1 1 017AOC Auditorium1, front door Auditorium 1, showroom door User interface Navigation with images and / or plans Navigation via tree structure Software platform Windows 2000 to Windows Vista Web browser: Explorer, Firefox, Opera or Safari Follow-up - Wired autonomous luminaires - Wireless autonomous luminaires - K9 module - Emergency units - Central battery for luminaires + EBS systems Reporting In accordance with EN50172 With web TM, luminaires can easily be located on images or maps of your building. network Direct connection to the luminaires Connection to a local network (LAN) via a COM server Connection via a landline (RS232 driver) Connection with a building management system Potential-free contact Saved daily as an export file in ASCII-format 9

Safety Manager (): wired / wireless 60 Coordinator KH12 130 230V 50Hz + - 112 overload K4H12 xmt power BUS POWER SUPPLY + - 160 110 L N bus Communication network BUS 230V 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz K4H16 status K4H16 status K4H16 status K4H16 status com xmt com xmt com xmt com xmt bus xmt bus xmt bus xmt bus xmt BUS ADAPTER power BUS ADAPTER power BUS ADAPTER power BUS ADAPTER power Tx Rx B Gnd PC A V+ Tx Gnd Rx V+ Tx Gnd Rx Tx Rx B Gnd PC V+ Tx Gnd Rx V+ Tx Gnd Rx V+ Tx Gnd Rx V+ Tx Gnd Rx A V+ Tx Gnd Rx V+ Tx Gnd Rx FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER FROM COM. PORT OR PREV. ADAPTER SHORT OR TO NEXT- ADAPTER A > B MAX. 8M bus A > B MAX. 8M first bus intermediate bus last bus