Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)



Similar documents
Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Modular I/O System Analog and Digital Interface Modules

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Thyristor-controlled power supplies and battery chargers

Product and functional description

PD 100A. Printing data system

WD-AMX Water Detection Controllers

AutoRanging Digital MultiMeter

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

GSM HOME SECURITY SYSTEM

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

BLOOD COLLECTION MIXER

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Product Information Sheet UH28CS-12kV Hi Pot Tester

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

IO-DIM6 6-Channel, Digital to Analogue Converters

Product Information Sheet UH36 Hi Pot Tester

HMI display Installation Guide

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Preset Counter signo 721

Drayton Digistat +2RF/+3RF

LC/LCD ranges level controllers

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Applied Electronics. Commercial Dimming System UPDATE NOTICE

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Mobile Data Power Model: MDP-25

T7560A,B,C Digital Wall Module

38 Series - Relay interface modules A

Electronic Pressure Switch EDS 300

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Speed Control Relays SX2

ABB i-bus EIB Logic Module LM/S 1.1

60 Series - General purpose relays 6-10 A. Features

FIREDEX Conventional Fire Panels

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Safety technique. Emergency stop module BO 5988 safemaster

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

is then retained absolutely without interruption.

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Manual Ranging MultiMeter

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

80 Series - Modular timers 16 A. Features

Duct Humidity Transmitter

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Multi-Range Programmable DC Power Supplies 9115 Series

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

13 SERIES. Electronic step relays A

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

EBDSPIR-PRM, EBDSPIR-PRM-IP

I STAR COMPUTER CO., LTD

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Actuator for modulating control AME 435

Voltage Regulator SPAU 341 C. Product Guide

MINI MCR-SL-R-UI(-SP)

instabus KNX / EIB System System E F G H

HERZ-Thermal Actuators

Ground Resistance Clamp On Tester

Multi-Range Programmable DC Power Supplies 9115 Series

Combi B Alarm box. Mounting instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Installation and Operation Back-UPS 1250, 1300, 1500

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Operating instructions. RCD flat 4-fold, 6-fold

SX460. Generator Automatic Voltage Regulator Operation Manual

How To Use A Power Supply On A Powerline 2.2 (Ai)

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

STERILIZERS, LABORATORY DRYING OVENS

User s Manual AURORA 1.2K/2.2K

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

IO-RM3 3-Stage Relay Module

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Inwall Room Temperature Unit

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB i-bus KNX SA/S Switch Actuators Product Manual

38 Series - Relay interface modules A

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

AC3200 INTELLIGENT BROADBAND AMPLIFIER

COMPALARM AP GENERAL MAIN FEATURES

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Transcription:

Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating the operating manual for their appliances. Subject to technical modifications and availability. Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 1 of 12

Operating Manual for the Electronic Built-in Interval Timer Micro II With the electronic built-in interval timer, connected appliances or appliance modules can be switched on and off using second or minute precision. Fig. 1: Version with membrane Fig. 2: Version without membrane Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 2 of 12

Use of this document Before fitting, connecting and using this timer, it is absolutely necessary that you read this operating manual thoroughly. Safety instructions This timer may only be fitted by a qualified electrician. Warning! Shock hazard! This timer uses the specified supply voltage. Fit the timer appropriately before connecting it to the mains supply. Never touch the live contacts or components at the open back of the timer. In the case of 12 or 24 V models, the outputs do not correspond to the conditions for safety driven electrical disconnection. The supply voltage to the appliance should only be at SELV (low safety voltage) when a low safety voltage is applied equally to the output. If that is not the case operation with low safety voltage (SELV) is forbidden. Protection against touch contact must be ensured by a proper mounting. When fitting the timer, make sure that during normal operation of the appliance the timer was fitted in it is impossible to touch the live parts at the open back of the timer. When fitting the timer, make sure that during normal operation it is impossible for the end user of the appliance it was fitted in to remove the timer by pulling it to the front and exposing the live parts. Avoid any contact of the timer with water. Do not use the timer to control appliances which must be attended during operation. Overview of the timeswitch Micro II (countdown timer) Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Accessories: Fastening slider for installation (accessories no. 413271-110) Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 3 of 12

Functionality of the timeswitch The Micro II countdown timer is a timeswitch. Its function is to switch an electrical appliance on during a running time preset by the user and switch it off after this time has elapsed. The Micro II countdown timer is an electronic built-in timeswitch designed for installation in an electrical appliance or an control panel. The timer may only be operated after installation in a protective housing. A large 3-digit LCD display is provided for monitoring the countdown of the timer. Relay version: The Micro II countdown timer uses a relay to switch an electrical appliance on. During the preset running time, the relay energizes and activates the connected appliance or appliance module by closing a circuit. After the time has elapsed, the relay deenergizes and deactivates the connected appliance or appliance module by opening the circuit again. Transistor version: The transistor version works similarly to the relay version, but with a lower current flow. Function overview: Running time setting up to 9 hours and 59 minutes max. Repeat function DIP switches for configuration of: Short half-time alarm Time format setting Maximum setting for running time Continue or reset mode Version setting (basic or full) 3 functional buttons for easy use Input for door contact Connection of external buzzer possible Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 4 of 12

Description of the functional parts Abb. 3: Die Funktionsteile (1), (2) Contacts for connection to the mains supply (3), (4), (5) Contacts for connecting an appliance to be switched on/off (6), (7) Contacts for connecting an external buzzer (8), (9) Contacts for connecting a door contact These contacts and their designations are also featured on the type plate of the timer. (10) DIP switches 1 through 6 (11) LCD display (12) - button for setting the switching time (counting down) (13) MODE button for starting and stopping the timer (14) + button for setting the switching time (counting up) Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 5 of 12

Configuration using the DIP switches Use the DIP switches (10) for customizing the Micro II timeswitch. You can set each of the DIP switches 1 through 6 to OFF or ON. Leaving these switches unchanged means that the switches 2 and 4 remain in position ON, every other switch is in position OFF, and the timer operates using the ex-works settings described below. Warning! Shock hazard! Before changing any DIP switch settings, always disconnect the timer from the mains supply. Caution! Change DIP switch settings using a small screwdriver and proceed carefully in order to avoid any slipping of the screwdriver which might damage the components of the timer. DIP switch 1: Half-time alarm Use this switch to determine if a short beep will sound after the first half of the preset running time has elapsed. OFF ON Half-time alarm off (default setting) Half-time alarm on DIP switch 2: Time format Use this switch to determine if the timer will operate in a minutes:seconds or hours:minutes time format. OFF ON Minutes:seconds Hours:minutes (default setting) DIP switches 3 and 4: Maximum setting for running time Use these switches to select the maximum value for the running time setting. This value depends on the position of DIP switch 2 (selected time format). 1. DIP switch 2 set to OFF: You can set a running time of up to 9 minutes and 59 seconds. Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 6 of 12

2. DIP switch 2 set to ON: You can set a running time of up to 9 hours and 59 minutes. Switch 3: OFF Switch 4: OFF Running times up to 0 : 15 Switch 3: OFF Switch 4: ON Running times up to 0 : 30(def.setting) Switch 3: ON Switch 4: OFF Running times up to 1 : 00 Switch 3: ON Switch 4: ON Running times up to 9 : 59 DIP switch 5: Stop Mode Use this switch to determine how the timer behaves after a stop: Continue Mode means that it resumes counting the remaining time, Reset Mode means that it restarts counting down from the beginning. OFF ON Continue Mode (default setting) Reset Mode DIP switch 6: Basic version or full version Use this switch to determine if you want to utilize the full functionality of the timer (default setting) or if you only need a limited functionality (basic version). For the basic version, the following functions are available: 3 fixed intervals: 15, 30, 60 seconds (DIP switch 2 set to OFF) 15, 30, 60 minutes (DIP switch 2 set to ON [default setting]) 2-digit LCD display While the time elapses, the digits flash instead of the colon OFF ON Full version (default setting) Basic version Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 7 of 12

Fitting and connecting the timer Important! When fitting the timer, see the dimensioned drawing in the product data sheet. 1. Installation of the timer (console cutout 66 x 66 mm): Fit the timer by pushing it from the front into the cutout provided on your appliance. It can then be easily attached by means of the supplied fastening sliders (accessories no. 413271-110): Insert the two fastening sliders into the dovetail-type guide notches on the left and right hand sides of the timer housing so that their two arms point to the front. Push the fastening sliders forward until the two arms make close contact with the console and hold the timer housing in position. The fastening sliders snap audibly into the guide notches of the timer housing. Fig. 3: Fitting the timer from the front 2. If desired, connect an external buzzer to the timer using contacts (6) and (7). Connected load of the buzzer: 5 V, 15 ma. 3. If desired, connect a door contact to the timer using contacts (8) and (9). For this connection, first remove the jumper between contacts (8) and (9). Connected load: max. 5 V 4. Connect the relay (consumer) using contacts (3) through (5). (For a connection diagram, see the type plate.) 5. Connect the timer to the mains supply using contacts (1) and (2). 6. Remove protective film. Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 8 of 12

Operation of the timer The timer is operational and ready to switch the connected appliance or appliance module on and off as soon as power is applied and the LCD display lights up. If the DIP switches are still in their original positions, the following default settings apply: No alarm sounds after the first half of the set running time has elapsed. The timer counts and displays hours and minutes. The maximum running time is 30 minutes. After a stop, the timer resumes counting the remaining time. The timer operates with unlimited functionality (full version). Setting a running time Using the - (12) and + (14) buttons, you can set the desired running time during which an appliance or appliance module will operate. Proceed as follows: 1. Briefly press the + button. Each time you press the button, the running time setting will be incremented by 1 (second or minute, respectively). 2. Press the + button for more than 3 seconds. The timer will start a continuous and fast count-up. Once the desired time value is shown on the display, simply release the + button. If you use this method, it may happen that you overshoot the desired value for the running time. In this case, correct it by decreasing the value using the - button: 3. Briefly press the - button. Each time you press the button, the running time setting will be decreased by 1 (second or minute, respectively). 4. Press the - button for more than 3 seconds. The timer will start a continuous and fast countdown. When the desired time value is shown on the display, simply release the - button. Important! The maximum value for the running time defined by the positions of the DIP switches 2, 3, and 4 cannot be exceeded by pressing the + button. Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 9 of 12

Starting the timer Press the MODE button (13). The appliance or appliance module connected to the timer is switched on. The displayed running time is counted down while the colon in the center of the time display flashes (full version). Stopping and restarting the timer DIP switch 5 set to OFF Continue Mode (default setting): 1. Press the MODE button. The timer stops, and the connected appliance or appliance module is switched off. The remaining running time is shown on the display. 2. Press the MODE button again. The connected appliance or appliance module is switched on again, and the timer resumes its countdown. DIP switch 5 set to ON Reset Mode: 1. Press the MODE button. The timer stops, and the connected appliance or appliance module is switched off. The timer display shows the preset running time again. 2. Press the MODE button again. The connected appliance or appliance module is switched on again, and the timer restarts counting down the preset running time from the beginning. End of running time After the preset running time has elapsed, the timer switches the connected appliance or appliance module off issuing short beeps (for up to 15 seconds). The value 0:00 is shown on the display, and the colon stops flashing. 1. Press the MODE button to stop the acoustic signal. The previously set short time reappears on the display (repeat function). 2. If you press the MODE button again, the timer restarts counting down the displayed running time. Power failure If a short power failure (<1 second) occurs during the operation of the timer, the timer stops and its relay switches the connected appliance or appliance module off. After the interruption, the connected appliance is switched on again, and the timer resumes counting down the remaining time. Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 10 of 12

In case of a longer power failure, the connected appliance is not switched back on after the interruption, and the value 0:00 is shown on the display. Operation with a door contact A door contact can be connected to contacts (8) and (9). It can be used to stop the countdown of the timer if a door is opened for example. Important! For connecting a door contact, it is necessary to remove the jumper between contacts (8) and (9). Door contact open: 1. You can only start the timer when the contact is closed. Door contact closed: 2. You can program and start the timer. Opening the door contact: 3. If the timer operates normally and you open the door contact, the timer stops. The remaining time is shown on the display, and the connected appliance or appliance module is switched off. 4. Now it is possible to change the remaining time using the + and - buttons. Closing the door contact: 5. Remaining time not changed: The timer automatically resumes counting down the remaining time. 6. Remaining time changed: Press the MODE button to start the countdown. Operation with an external buzzer An external buzzer can be connected to contacts (6) and (7). Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 11 of 12

The Micro II electronic countdown timer Functions Maximum running time: 9 hours 59 minutes Time programs: Depends on the selected time format: Hours:minutes time format: 0:15, 0:30, 1:00, 9:59 Minutes:seconds time format: 0:15, 0:30, 1:00, 9:59 Repeat function: yes Configuration using DIP switches: yes, see pages 6 and 7 Product features Display: 3-digit LCD display Controls: 3 functional buttons ( +, MODE, - ) Power failure carryover: yes, if power failure lasts < 1 second Buzzer: yes Connection of an external buzzer yes, 5 V, 15 ma possible: Connection of a door contact possible: yes, max. 5 V Technical data Nominal voltage (VDE-tested): 12/24 VAC/DC, 230-240 VAC ±10% Nominal voltage (UL-tested): 110-120 VAC ±10% Nominal frequency: 50/60 Hz Switching rate: 1-pole 16(2)A/250 VAC, 10(2)A, 250 VAC Relay output: 1-pole Optional transistor output: <=100 ma/40 VAC Power consumption: Permissible ambient temperature: approx. 1.8 W 0 75 C (version without membrane) 0 55 C (version with membrane) Storing temperature: -25 C 75 C Ambient conditions: Normal contamination (for appliances complying with the EN 60 335-1 standard) Safety class: II after appropriate installation Software class: A Action: Type 1B for relay switching version Type 1Y for transistor switching version Timer precision: ± 2 seconds/day at 25 C Dimensions of control panel housing: 72 x 72 x 38 mm Additional UL-requirements: Rated Impulse Category: Operating time: Enclosure Protection: Construction: Overvoltage category III 120 V model 2500 V 12 V model 800 V 24 V model 800 V and VDE-EMC-sign long period Type I Incorporated Control Diehl AKO Stiftung & Co. KG, Werk Nürnberg, Donaustraße 120, D-90451 Nürnberg Page 12 of 12