Facility Operations Physical Safety Guidance Document



Similar documents
IDENTIFICATION FOR PIPING AND EQUIPMENT

MECHANICAL PIPING PAINTING & IDENTIFICATION REQUIREMENTS

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

Some Criteria for Choosing a Steam Boiler for a Microbrewery

How to Prevent Liquid Damage Property Losses

When Should Examination Preparation Begin?

Copper and Copper Alloy Tube, Pipe and Fittings

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

EACH CLASS of fire A, B, C, or D has a different source. Some

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

PRODUCT IDENTIFICATION SYSTEM FOR TERMINALS / DEPOTS IN SOUTH AFRICA

Compressed Gas Cylinder Safety

Element D Services Plumbing

Facilities Maintenance Standards rev

Plumbing Code in Commercial Kitchens

01 - Plastic Pipe Cements and Primers

WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER. Dear: Human Resources

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

A placard provides the viewer with a variety of information through several different methods. First is the color of the placard.

Energy Efficiency HOSPITALITY.

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Refrigeration Installation 101

Routine and Emergency Boiler Operation

UCLA - Compressed Gas Cylinder Storage and Handling

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Building and Grounds Maintenance Checklist

Standard Operating Procedure

Medical Gas Installation Handbook A-Z. A guide to installing Medical Gas equipment from alarm panels to zone valves.

Fire Pump Plan Review March 2010

AMIPOX GRE Pipe systems. Glass Reinforced Epoxy Pipe Solutions for various Applications

Guide to good leak testing

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Chapter 7 Plumbing Connections

Pipe Marker Co. Catalog fax

Most agencies think about cleaning because of debris in the line.

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

COATINGS MANUAL HRSD 6.0 EQUIPMENT AND PIPING COLOR IDENTIFICATION CODE

Dry Ice Color Show Dry Ice Demonstrations

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

PLBG/GAS SAFETY Information Bulletin

UNDERSTANDING CENTRAL HEATING SYSTEMS

PBX Series Quick Fit Connector Bimetallic Steam Traps

Ethanol Vehicle and Infrastructure Codes and Standards Citations

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

TABLE OF CONTENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Notes. Material 1. Appropriate Flammable Liquids

TABLE OF CONTENT

How To Make A High Co 2 Gas Blend

FLASH TANK ECONOMIZER PRODUCT GUIDE

Hygiene Standards for all Food Businesses

Boiler & Pressure Vessel Inspection discrepancies and failures

PLUMBING, HEATING & AIR CONDITIONING, REFRIGERATION & BOILER INSTALLATION CONTRACTORS QUESTIONNAIRE

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

Compressed Gas Cylinder Storage and Handling Guide

NEW JERSEY CENTER OF EXCELLENCE

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Energy Saving Fact Sheet Boilers

Steam System Best Practices Condensate System Piping

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Element D Services Plumbing

User's Instructions. Alpha HE CB25/33 and HE SY25

PLANT MAINTENANCE - PLUMBER & STEAMFITTER APPENDIX A D.O.T. CODE O*NET CODE WORK PROCESSES

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

The Basics of Natural Gas

Quik Lining Systems Heater Owners Guide

Energy Efficient Operations and Maintenance Strategies for Boilers

Homeowners Air Conditioning Troubleshoot Checklist

B. Types of mechanical insulation specified in this section include the following:

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

WHY A FATS, OILS AND GREASE PROGRAM. Employee Food Service Establishment Information Sheet INTRODUCTION

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

DRYER VENTING SPECIFICATIONS DRYER SAFETY

JOB ANNOUNCEMENT Houston Housing Authority

Certain specific properties of compressed gases make them highly useful in various research activities.

THE HUMIDITY/MOISTURE HANDBOOK

Project Building Permit No. One complete set of Record or as-built drawings (electronic) One complete set of Record or as-built drawings (hard copy)

Nitrogen Blanketing for Methanol Storage and Transportation

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Steam Generation Efficiency Module Blowdown Losses Section

FIRING RANGE PHASE 1 DESIGN

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Transcription:

Facility Operations Physical Safety Guidance Document Title: Guide on Pipe Identification Standards (ASME A13.1-1996) Original Date: December 18, 2000 Section: 4.0 Facility Operations Revised Date: Number: A4.1 This document provides guidance for The University of Texas Houston Health Science Center's Visually Instructive Labeling Program. The program follows the requirements outlined in the ASME A13.1-1996 Scheme for the Identification of Piping Systems. This document is specifically for facility utility piping. The program is aimed at reducing errors and accidents while at the same time increasing training and housekeeping effectiveness, employee morale, safety and productivity. This is accomplished through using labels and tags, which have color-coding, key words, and /or symbols which are standardized through ASME, ANSI and OSHA. Consistent application of the same sign to the same hazard will familiarize existing, new, and contract employees with the facility and reduce the possibility of errors and accidents while producing a quicker, surer response in emergency situations. Included in this document are tables of specifications, which are to be used to ensure labeling consistency. The Visually Instructive Labeling Program is a continual process. All Facility Operations personnel are responsible for monitoring the University facilities for proper markings, signs and labels. If a label should be missing or illegible, Facility Operations personnel shall ensure the sign is replaced as soon as possible. Everyone must be involved in the process including knowing what the program is and why it is important to the University. Furthermore, personnel are encouraged to give suggestions and recommendations to ensure labeling is as effective as possible. Page 1 of 5

Ordering Labels Labels can be ordered from catalogs or made at UCT 1880. Facility Operations and Physical Safety have label makers that can be used by Facility Operations personnel. Supplies can be order from the catalog located at UCT. Installing Labels It is recommended that self-sticking pipe labels be used. These labels are applied by peeling the paper backing from the label and pressing the label in place on the pipe. The adhesives perform best when place on a smooth, clean, dry surface. Therefore, the pipe should be cleaned with a wet cloth and then allowed to dry. If the surface is rough, it should be smoothed with sandpaper and the residual dirt removed with a wet cloth. It is required to also apply bands of arrows tape at each end of the label, indicating the direction of flow in the pipe. The bans shall be wrapped 360 degrees around the pipe so the direction markers can be seen all the way around the pipe. TABLE 1 SIZE OF LEGEND LETTERS Outside Diameter Length of Color Size of of Pipe Field Letters or Covering A B in. mm in. mm in. mm 3/4 to 1 1/4 19 to 32 8 200 1/2 13 1 1/2 to 2 38 to 51 8 200 3/4 19 2 1/2 to 6 64 to 150 12 300 1 1/4 32 8 to 10 200 to 250 24 600 2 1/2 64 over 10 over 250 32 800 3 1/2 89 The labels shall be located so that they are readily visible to personnel from the point at which they would normally approach the pipe. The pipes shall be marked in the following areas. A) Adjacent to changes in direction. B) Adjacent to all valves and flanges. C) At both sides of floor or wall penetrations. D) At any other point of entry into the line. E) At 50 foot intervals of straight runs. Page 2 of 5

FIGURE 1 LABEL VISIBILITY AND LOCATIONS TABLE 2 MATERIALS AND DESIGNATION OF COLOR Blue Background With White Letters Air Compressed air Oxygen Low Pressure air Supply air Return air Asbestos free insulation Exhaust air Medium pressure air Medical air Instrument air Green Background With White Letters Argon Chilled water Chilled water return City water Cold water supply Condenser water Condenser water return Deionized water Distilled water Brine Tempered water Chilled water supply Circulating water Cold water Cold water return Condenser water supply Cooling water Discharge Domestic water Page 3 of 5

Drain Drain water Green Background With White Letters Filtered water Inert gas Nitrogen Potable water Refrigeration Sanitary drain Storm drain Storm water Vacuum Waste water Freon Make-up water Plumbing vent Rain water Roof drain Sanitary sewer Storm sewer Treated water Vent Red Background With White Letters Fire protection water Sprinkler-water Sprinkler-fire Yellow Background With Black Letters Acetone Ammonia Blow-off water Boiler feed Carbon dioxide Chlorine Condensate Condensate return Domestic hot water Domestic hot water return Dual temp return Exhaust steam Fuel oil Glycol Heating Heating return Heating water return Hi-pressure condensate Hi-pressure steam Hot chilled water supply Hot water Hot water return Lo-pressure condensate Lo-pressure steam Natural gas Acid Backwash Boiler blow down Boiler feed water Caustic City gas Condensate supply Diesel waste oil Domestic hot water supply Dual temp supply Exhaust Fuel gas Gas Heat Heating supply Heating water supply Hi-pressure air Hi-pressure gas Hi-pressure water Hot chilled water return Hot water supply Hydrogen Lo-pressure gas Medium pressure steam Nitrous oxide Page 4 of 5

Non-potable water Yellow Background With Black Letters Oil Propane gas Refrigerated liquid Solvent Steam supply Suction Vapor Plant air Pumped condensate Refrigerated suction Steam Steam return Unsafe water Waste oil *MEDICAL GAS PIPE MARKERS NFPA 99C-Section 4-3.5.4.1 The gas content and operating pressure of medical gas piping systems shall be identifiable by labeling with name and pressure of the gas contained. Labeling shall appear at intervals not more than 20 ft. and at least once in each room and each story traversed by the piping system. LEGEND BACKGROUND COLOR LETTER COLOR Carbon Dioxide Gray White Cyclopropane Orange Black Helium Brown White Medical Air Yellow Black Medical Air 50-55 PSI Yellow Black Medical Vacuum White Black Natural Gas 2 PSI Yellow Black Nitrogen Black White Nitrogen 180-200 PSI Black White Nitrous Oxide Blue White Nitrous Oxide 50-55 PSI Blue White Oxygen Green White Oxygen 50-55 PSI Green White Page 5 of 5