2- and 3-port valves with flanged connections, PN 10



Similar documents
Butterfly Valves PN 6/10/16 for flanged connection

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

RRV934. Multi-controller. Synco living

Thermostatic Actuators

QLM and QLD Series Three-port Control Valves

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Type overview. Technical data

SISTO-16TWA/HWA/DLU. Type Series Booklet

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

VAD Variable Area Desuperheaters

Overview of types. Technical data

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Self-operated Temperature Regulators Temperature Regulator Type 1u

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

VAD. Variable Area Desuperheaters

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Air damper actuators

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Valve and Valve Actuator Selection Guide

Series description: Wilo-Yonos MAXO-D

Type 3353 Angle Seat Valve

Series description: Wilo-Yonos MAXO

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

3/2- and 2/2-way cartridge valve type BVE

Thermostatic valve Type AVTA

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

HVAC Valves and Actuators Catalogue

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Operating Instructions for Plastic Flow Meter. Model: KSK

Automatic control equipment for HVAC systems

MFP14, MFP14S and MFP14SS Automatic Pumps

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Digital inductive conductivity transmitter

Electric Rotary Actuator - On/Off or programmable control actuator

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

V47 Series Temperature Actuated Modulating Water Valves

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Kämmer Series Laboratory Valves

Materials : Cast iron body

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Assisted lift operated 2/2-way solenoid valves Type EV250B

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Direct steam injection humidifiers

Instruction Manual Differential Pressure Transmitter

2/2 and 3/2 Way Size 6 Seat Valves

CSF16 and CSF16T Stainless Steel Steam Filters

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Heating, air-conditioning, cooling

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Solenoid valves Type EVU

FlowPak TM General Application Valve 1/2-4, Class 150

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

Series description: Wilo-Drain TC 40

Data sheet ECC 12 and 22

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

Stainless Steel Valves For the Sanitary Industries

VALVES FOR REFRIGERATING SYSTEMS

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

3/2-way Solenoid Valve, direct-acting, NC or NO

4 Posiflow Proportional Solenoid Valves

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Backflush filter R8-30W

RUBBER SLEEVE KNIFE GATE VALVE

Actuator for modulating control AME 435

HVAC Valves and Actuators Catalogue

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

Duplex Filters 40 FLDK 0008(C)-0120(C)

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Retrofit with Siemens

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Transcription:

4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey cast iron ENGJL250 DN 15 150 k vs 1.6 400 m 3 /h Flange type 21, flange design B Equipable with electromotoric actuators SAX.. or electrohydraulic actuators SKD.., SKB.., SKC.. Use In boiler, district heating and refrigeration plants, heating groups, ventilation and airhandling units as control or shutoff valves. For use in closed circuits. CE1N4402en 20151126 Building Technologies

Type summary Valves Actuators SAX.. SKD.. SKB.. SKC.. Stroke 20 mm 40 mm PN 10 Positioning force 800 N 1000 N 2800 N 2800 N Data sheet N4501 N4561 N4564 N4566 DN k vs S V p s p max p s p max p s p max p s p max 10 150 C Stock number [m 3 /h] [kpa] VVF32.151.6 S55202V100 15 1.6 VVF32.152.5 S55202V101 15 2.5 VVF32.154 S55202V102 15 4 >50 1000 1000 VVF32.256.3 S55202V103 25 6.3 400 400 1000 VVF32.2510 S55202V104 25 10 VVF32.4016 S55202V105 40 16 550 750 VVF32.4025 S55202V106 40 25 400 VVF32.5040 S55202V107 50 40 350 300 450 VVF32.6563 S55202V108 65 63 200 150 250 200 700 >100 VVF32.80100 2) S55202V109 80 100 125 75 175 125 450 VVF32.100160 2) S55202V110 100 160 300 250 VVF32.125250 S55202V111 125 250 190 160 VVF32.150400 2) S55202V112 150 400 125 100 2) Suitable for medium temperatures up to 130 C Valve characteristic for k vs value 100 m 3 /h from 70% stroke, k vs value 160 m 3 /h from 85% stroke and k vs value 400 m 3 /h from 90% stroke is optimized for maximum volumetric flow Valves Actuators SAX.. SKD.. SKB.. SKC.. Stroke 20 mm 40 mm PN 10 Positioning force 800 N 1000 N 2800 N 2800 N Data sheet N4501 N4561 N4564 N4566 DN k vs S V p max [kpa] 10 150 C Stock number [m 3 /h] VXF32.151.6 S55202V113 15 1.6 VXF32.152.5 S55202V114 15 2.5 VXF32.154 S55202V115 15 4 >50 VXF32.256.3 S55202V116 25 6.3 400 100 400 100 VXF32.2510 S55202V117 25 10 400 100 VXF32.4016 S55202V118 40 16 VXF32.4025 S55202V119 40 25 VXF32.5040 S55202V120 50 40 300 VXF32.6563 S55202V121 65 63 150 200 80 >100 50 VXF32.80100 2) S55202V122 80 100 75 125 50 VXF32.100160 2) S55202V123 100 160 250 VXF32.125250 S55202V124 125 250 160 50 VXF32.150400 2) S55202V125 150 400 100 2) Suitable for medium temperatures up to 130 C Valve characteristic for k vs value 100 m 3 /h from 70% stroke, k vs value 160 m 3 /h from 85% stroke and k vs value 400 m 3 /h from 90% stroke is optimized for maximum volumetric flow DN = Nominal size k vs = Flow nominal value of cold water (5...30 C) through the fully opened valve (H 100) at a differential pressure of 100 kpa (1 bar) S v = Rangeability p s = Maximum permissible differential pressure at which the motorized valve still closes securely against the pressure p max = Maximum permissible differential pressure across the valve s throughport for the entire positioning range of the motorized valve 2 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Ordering Example Product number Stock number Description VXF32.151.6 S55202V113 3port valve with flange, PN 10 SKD32.50 SKD32.50 Electrohydraulic actuator Delivery Note Spare parts, Rev.No. Valves, actuators and accessories are packed and delivered as separate items. Counterflanges, bolts and gaskets must be provided on site. See page 13 Equipment combinations Product number SAX31.00 SAX31.03 SAX61.03 SAX61.03U SAX81.00 SAX81.03 SAX81.03U SKD32.21 Description S55150A105 S55150A106 S55150A100 S55150A100A100 S55150A102 S55150A103 S55150A103A100 SKD32.21 Stroke Positioning force 20 mm 800 N 20 mm 1000 N Operating voltage AC 230 V AC 24 V DC 24 V Positioning signal 3position 0 10 V 4 20 ma 0 1000 Spring return time 3position AC 230 V 3position SKD32.50 SKD32.50 SKD32.51 SKD32.51 8 s SKD60 SKD62 SKD62U SKD62UA SKD82.50 SKD82.50U SKD82.51 SKD82.51U SKD60 SKD62 SKD62U SKD62UA SKD82.50 SKD82.50U SKD82.51 SKD82.51U AC 24 V 0 10 V 4 20 ma 0 1000 3position SKB32.50 SKB32.50 AC 230 V 3position SKB32.51 SKB32.51 10 s SKB60 SKB62 SKB62U SKB62UA SKB82.50 SKB82.50U SKB82.51 SKB82.51U SKB60 SKB62 SKB62U SKB62UA SKB82.50 SKB82.50U SKB82.51 SKB82.51U 20 mm 2800 N AC 24 V 0 10 V 4 20 ma 0 1000 3position SKC32.60 SKC32.60 AC 230 V 3position SKC32.61 SKC32.61 18 s SKC60 SKC62 SKC62U SKC62UA SKC82.60 SKC82.60U SKC82.61 SKC82.61U SKC60 SKC62 SKC62U SKC62UA SKC82.60 SKC82.60U SKC82.61 SKC82.61U 40 mm 2800 N 2) 3) 4) AC 24 V 0 10 V 4 20 ma 0 1000 3position 8 s 15 s 8 s 10 s 10 s 20 s 18 s Positioning time LED 120 s 30 s 120 s 30 s Opening: 30 s Closing: 10 s 120 s Opening: 30 s Closing: 15 s 120 s 120 s Opening: 120 s Closing:10 s 120 s 120 s Opening: 120 s Closing: 20 s 120 s Auxiliary switch, potentiometer Position feedback, forced control, selection of valve characteristic Optional: sequence control, selection of acting direction Plus sequence control, stroke limitation, and selection of acting direction Manual adjuster Press and fix Turn, Position is maintained Turn, Position is maintained Turn, Position is maintained Auxiliary functions 2). 3) 2) 4) 2) 4) 2) 4) 3 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Product documentation Mounting Instructions M4030 74 319 0749 0 Basic documentation P4030 Contains background information and technical basic knowledge of valves Technical and mechanical design The illustrations below show the basic design of the valves. Constructional features, such as the shape of plugs, may differ. 2port valves Fluids Closing against the pressure For use with all actuators Note 2port valves do not become 3port valves by removing the blank flange! 3port valves Fluids Mixing valve (preferred use) Diverting valve 4 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Accessories Product number Stock number Description Note Example ASZ6.6 S55845Z108 Stem heating element Required for medium temperatures < 0 C Sizing Flow chart 1000 800 600 500 400 300 200 150 100 80 60 50 40 30 20 10 8 6 5 4 3 2 1 0,8 0,6 0,5 0,4 0,3 0,2 0,1 0,08 0,06 0,05 0,04 0,03 0,02 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 200 300 400 500 600 800 1000 1500 2000 0,01 0,02 0,03 0,04 0,05 0,06 0,08 0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 5 6 8 10 15 20 3000 2000 1500 0,06 0,05 0,04 0,03 0,025 0,02 0,015 0,01 0,008 0,006 3000 1,5 2 3 4 30 k VS 400 1.6 250 40 25 16 10 6.3 4 160 100 63 2.5 800 600 500 400 300 250 200 150 100 80 60 50 40 30 25 20 15 10 8 6 5 4 3 2,5 2 1,5 1 0,8 0,6 0,5 0,4 0,3 0,25 0,2 0,15 0,1 0,08 p max values apply for the mixing function. p max values for the diverting function see table Type summary, page 2 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126 5 / 14

Valve characteristics 2port valves Flow rate kv / kvs 0 30%: Linear 30 100%: Equal percentage n gl = 3 to VDI / VDE 2173 For high k vs values the valve characteristic is optimized for maximum volumetric flow k V100. Stroke H / H 100 For product lines: VVF32.125250 VVF32.150400 Durchfluss kv / kvs 0 100%: Linear 3port valves Flow rate kv / kvs Throughport AAB 0...30%: Linear 30...100%: Equal percentage n gl = 3 to VDI / VDE 2173 For high k vs values the valve characteristic is optimized for maximum volumetric flow k V100. Bypass BAB 0...100%: Linear Stroke H / H 100 Tor AB = constant flow Tor A = variable flow Tor B = bypass (variable flow) Mixing: Diverting: Flow from port A and port B to port AB Flow from port AB to port A and port B For product lines: VXF32.125250 VXF32.150400 Durchfluss kv / kvs Durchgang AAB 0...100%: Linear Bypass BAB 0...100%: Linear Hub H / H 100 6 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Operating pressure and medium temperature Fluids, PN10 with V..F32.. Operating pressure [bar] Medium temperature [ C] Curve for saturated steam; steam forms below this line Operating pressure according to EN 1092, valid for 2port valves with blank flange Operating pressure and operating temperatures according to ISO 7005, EN 1092 and EN 12284 Notes Medium compatibility and temperature ranges All relevant local directives must be observed Medium Temperature range Valve V..F32.. Note T min [ C] T max [ C] Cold water 1 25 Lowtemperature hot water 1 130 Hightemperature hot water 130 150 Water with antifreeze 5 150 For medium temperatures 10 150 20 150 below 0 C, the stem heating ASZ6.6 has to be installed. Brines 5 150 For medium temperatures 10 150 below 0 C, the stem heating 20 150 ASZ6.6 has to be installed. Demineralized water according to VDI2035 / SWKI_BT10201 1 150 Differentiation due to saturated steam curve Fields of use Fields of use Valves VVF32.. VXF32.. Generation Boiler plants District heating plants Refrigeration plants Distribution Heating groups Ventilation and airhandling units Engineering notes Mounting location Dirt trap Cavitation Preferably mount the valves at the return, as the temperature is lower there and the stem sealing gland is less strained. Mount a dirt filter or dirt trap before the valve to ensure proper functioning, and a long service life of the valve. Remove dirt, welding beads, etc. from the valves and pipes. Cavitation can be avoided by limiting the pressure differential across the valve depending on the medium temperature and prepressure. Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126 7 / 14

Mounting notes Mounting position Indoors Outdoors Commissioning notes Mounting positions apply to both 2 and 3port valves. Note Function check The valve may be put into operation only if actuator and valve are correctly assembled. Ensure that actuator stem and valve stem are rigidly connected in all positions. Valve Throughport A AB Bypass B AB Valve stem extends Closes Opens Valve stem retracts Opens Closes Maintenance notes Valves are equipped with maintenancefree, continuously lubricated stem sealing glands. See page 13 for replacement stem sealing glands. When servicing valves or actuators: Deactivate the pump and turn off the power supply Close the shutoff valves Fully reduce the pressure in the piping system and allow pipes to completely cool down Disposal If necessary, disconnect the electrical wires. Due to the different types of material used, the valve must be disassembled prior to disposal. Special handling of certain valve components may be required by law or may be sensible from an ecological point of view. Local and currently valid legislation must be observed. Warranty Applicationrelated technical data are guaranteed only when the valves are used in connection with the Siemens actuators listed under Equipment combinations, page 3. When used with actuators of other manufacture, any warranty by Siemens becomes void. 8 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Technical data Functional data PN class PN 10 Connection Operating pressure Flange See Section "Operating pressure and medium temperatures", page 7 Valve characteristics See section "Valve characteristics", page 6 Leakage rate Throughport 0 0.02% of k vs value Bypass 0.5 2% of k vs value (k vs 6.3) 0.5 3% of k vs value (k vs 1.6; 2.5; 4) Permissible media See table " Medium compatibility and temperature ranges", page 7 Medium temperature 10 150 C 2) Rangeability To DN 25: > 50 From DN 40: >100 Nominal stroke To DN 80: 20 mm From DN 100: 40 mm Materials Valve body ENGJL250 Blank flange Valve stem Seat Plug Stem sealing gland VVF.. S235JRG2 Stainless steel Machined Brass/ Bronze Brass EPDM Orings PTFE sleeve siliconfree Standards Pressure Equipment Directive PED 97/23/EC Pressurecarrying accessories According to article 1, section 2.1.4 Fluid group 2 PN 10 Without CE certification as per article 3, section 3 (sound engineering practice) DN 80 Category I, with CE certification DN 100 150 Category II, with CE certification, notified body identification number 0036 PN class ISO 7268 Operating pressure ISO 7005, DIN EN 12284 Flanges ISO 7005 Length of flanged valves DIN EN 5581, line 1 Valve characteristic VDI 2173 Leakage rate Water treatment VDI 2035 Throughport, bypass according to EN 605344 / EN 1349 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126 9 / 14

Environmental conditions Storage: IEC 6072131 Class Transport: IEC 6072132 Class Operation: IEC 6072133 Class Environmental compatibility 1K3 Temperature 15 +55 C Rel. humidity 5 95% r.h. 2K3, 2M2 Temperature 30 +65 C Rel. humidity < 95% r.h. 3K5, 3Z11 Temperature 15 +55 C Rel. humidity 5 95% r.h. ISO 14001 (environment) ISO 9001 (quality) SN 36350 (environmentally compatible products) RL 2002/95/EG (RoHS) Dimensions / Weight Dimensions See Dimensions, page 11 Weight See Dimensions, page 11 For certain valve lines and high k vs values, the valve characteristic is optimized for maximum volumetric flow k V100. 10 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Dimensions VVF32.. A AB B 4030M10 Product number DN B Ø D Ø D1 Ø D2 L1 L2 X Y Ø K H1 H2 H SAX.. SKD.. SKB.. SKC.. VVF32.. 15 3.7 14 95 46 14 (4x) 130 86 79 76 65 37 133.5 479 537 612 25 5.4 15 115 65 14 (4x) 160 104 94.4 90.1 85 37 133.5 479 537 612 40 9.2 16 150 84 19 (4x) 200 126 123.2 117.8 110 37 133.5 479 537 612 50 12.2 16 165 99 19 (4x) 230 143 135.2 128.4 125 50 146.5 492 550 625 65 17 17 185 118 19 (4x) 290 173 150 142.5 145 75 171.5 517 575 650 80 25 17 200 132 19 (8x) 310 185 160 75 171.5 517 575 650 100 35.9 17 220 156 19 (8x) 350 205 180 110 226.5 685 125 52.5 17 250 184 19 (8x) 400 232 210 123 239.5 698 150 74.9 17 284 211 23 (8x) 480 275 240 150.5 267 726 11 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

VXF32.. A AB B Typ DN B Ø D Ø D1 Ø D2 Ø D3 L1 L2 X Y Ø K H1 H2 H SAX.. SKD.. SKB.. SKC.. VXF32.. 15 2.6 14 95 46 14 (4x) 23 130 65 79 76 65 37 133.5 479 537 612 25 3.8 15 115 65 14 (4x) 36 160 80 94.4 90.1 85 37 133.5 479 537 612 40 6.3 16 150 84 19 (4x) 56 200 100 123.2 117.8 110 37 133.5 479 537 612 50 8.7 16 165 99 19 (4x) 69 230 115 135.2 128.4 125 50 146.5 492 550 625 65 12.9 17 185 118 19 (4x) 85 290 145 150 142.5 145 75 171.5 517 575 650 80 19.2 17 200 132 19 (8x) 102 310 155 160 75 171.5 517 575 650 100 29 17 220 156 19 (8x) 124 350 175 180 110 226.5 685 125 43.2 17 250 184 19 (8x) 149 400 200 210 123 239.5 698 150 62.1 17 284 211 23 (8x) 174 480 240 240 150.5 267 726 12 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Spare parts Stem sealing gland Product number VVF32.. VXF32.. DN Stock number Comments Image DN 15 80 4 284 8806 0 Series A DN 100 150 4 284 8806 0 Series A, B and C until October 2015 DN 100 150 4 679 5629 0 Series D as of October 2015 Revision numbers VVF.. VXF.. Product number Valid from rev. no. Product number Valid from rev. no. VVF32.151.6..A VXF32.151.6..A VVF32.152.5..A VXF32.152.5..A VVF32.154..A VXF32.154..A VVF32.256.3..A VXF32.256.3..A VVF32.2510..A VXF32.2510..A VVF32.4016..A VXF32.4016..A VVF32.4025..A VXF32.4025..A VVF32.5040..A VXF32.5040..A VVF32.6563..A VXF32.6563..A VVF32.80100..A VXF32.80100..A VVF32.100160..D VXF32.100160..D VVF32.125250..D VXF32.125250..D VVF32.150400..D VXF32.150400..D 13 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2011 Technical specifications and availability subject to change without notice. 14 / 14 Siemens 2 and 3port valves with flanged connections, PN 10 CE1N4402en Building Technologies 20151126