MidNite Solar PV Combiners explained (MNPV)



Similar documents
MidNite Solar E-Panels Explained

Odyssey of the Mind Technology Fair. Simple Electronics

Contractors Guide Central Inverter System Installation

Electrical Fundamentals Module 3: Parallel Circuits

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

INSTALLER S INSTRUCTIONS FOR TRI-METRIC Battery system monitor, Models TM-2030-RV and TM-2030-A. Contents

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

3 Slot Payphone Controller

SOLAR ELECTRIC SYSTEM KITS

Doe Residence kw DC Roof Mounted Photovoltaic System

SOLAR PV SYSTEM MAINTENANCE GUIDE

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

SYSTEM 4C. C R H Electronics Design

FW-X240 AUTO TRANSFORMER Installation Manual

YSmart Technology Co.,Ltd

RADIANT PLASMA 4700 Plasma Spark Generator

Inverter / Charger Installation General Operations and AC and DC Connections

City of Riverside Building & Safety Division Phone: (951)

Roy Allen, Technical Training, 17FEB2015 ABB Solar Days Residential Products, Design & Application Rapid Shutdown. ABB Feb 27, 2014 Slide 1

Mini Power-Zone Unit Substation

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Product and functional description

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

Air-cooled Generator Battery Charger Installation Guidelines

Photovoltaic System Overcurrent Protection

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

DLP-PU/E Instruction Manual

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Permanent Magnetic Generator Construction Manual

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Polarity. Electrical Quals

How To Plan Out An Array Of Solar Panels

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Solar Water Heating and Photovoltaic Electrical Systems Installed on One or Two Family Dwellings

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

INSTALLATION & SERVICE MANUAL. Display Panel

TECHNICAL SPECIFICATIONS

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Parallel Circuits. Objectives After studying this chapter, you will be able to answer these questions: 1. How are electrical components connected

TruPower-Portable-500W. Solar Starter kit

County of Riverside Building and Safety Department

TIG INVERTER INSTRUCTION MANUAL

RayClic Connection System Installation Instructions

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Generator Transfer Switch Model # HTS15-AUTO

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

Switchboard system. NorLine 800

INSTALLATION INSTRUCTIONS

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Operating Instructions

ST Series POWER SUPPLIES USER INSTRUCTIONS

Using the Laser Cutter and AutoCAD Template

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

Series and Parallel Circuits

5800 Temperature Sensor Cable Assembly

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Prism Solar Installation Manual

The Simple DC Motor: A Teacher s Guide

Service Guide. Gateway M275

Grounding & Bonding Why it is done And How to Install Properly

Battery Power Inverters

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Electrical Safety Tester Verification

5SV Residual Current Protective Devices

Installation and Operation Guide for PD4000 Series Power Control Center

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME

Mounting instructions

ABB Inc. April 19, 2011 Slide 1

Provides one channel for Ethernet over existing

ENCODER TEST MODULE APPLICATION GUIDE

ECEN 1400, Introduction to Analog and Digital Electronics

Fuse Selection Guide

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Step Voltage Regulators

Manual. Solar Fountain Mobile Phone Charger

Transcription:

MidNite Solar PV Combiners explained (MNPV) The MNPV6 PV combiner is designed to work with 6 150V breakers or 4 touch safe 600VDC fuse holders. Busbars for both configurations are included. Based on sales, this little combiner has become the favorite of the RE industry. It is the first PV combiner to come with a custom deadfront to hide wiring when the metal cover is opened. One comment we have received is that the fuse holder configuration results in a compromise when the plastic dead front is used. It is difficult to make one deadfront that works well for both scenarios. The picture below shows how the touch safe fuse holders look when used with the deadfront as compared to breakers. The breakers are a better match with the deadfront. There is a gap around touch safe fuse holders. This is not a safety issue, but rather a cosmetic one. Not wanting to have a cosmetically challenged combiner, we recently designed a snap in adapter that will be included with all MNPV3 and 6 combiners. (February or March 2009). Check out the CAD pictures here. The fuse adapters and dead fronts are actually black. The left picture has fuse holders installed.

The snap in adapter has notches built in to act as a guide for cutting down for MNPV3 applications. To use for MNPV3 applications, cut the large piece down to 2 or 3 spaces using a Stanley knife. The two pieces will need to be glued or taped together. Material is ABS, so common ABS pipe glue should work nicely. Snap in adapter ready for the MNPV6 combiner Snap in adapter cut down and ready to glue together for installation into the MNPV3 combiner BusBars for the MNPV3: We never thought customers would be using the MNPV3 with touch safe fuse holders. Well, we were wrong big time. These are used all the time for high voltage applications. They are used as a combiner for string inverters as well as a high voltage disconnect. The problem is that they do not come with a fuse holder busbar. Starting sometime in February 2009, the MNPV3 will come with a new internal combining busbar. The new busbar is shown below

The new 1/8 thick copper busbar is rated for 83 amps and is reversible for use with fuses or breakers. In the past, customers would use the MNPV6 fuse busbar ($13.00 list) and cut it down for use in the MNPV3. Notice how the new MNPV3 busbar is set up for three breakers or three fuses. Each breaker is ½ wide where as the fuse holders are almost ¾ wide, thus separate finger arrangement for each application. The fact that we are putting three fuse holder fingers on the new busbar presents another problem. The MNPV3 Deadfront has three ½ knockouts. Three circuit breaker knockouts is the same width as two fuse holders. Take a close look at the back of the deadfront above. There have always been notches that would allow up to two more breakers. Now the numbers don t exactly work out perfectly for three fuse holders, but they do fit (3/4 x 3 = 2 ¼ vs. ½ x 5 = 2 ½ ). There will be a 1/8 gap on either side. The new adapter helps cover this gap somewhat though. All the MNPV3 combiners now come with a din rail that will accept up to 5 breakers, so three fuse holders is not a problem. We do not supply a busbar for more than three breakers, but the MNPV6 breaker busbar is available for $15.00. At this point you may just want to consider the MNPV6 as it has sufficient room for more than three breakers. PV minus and ground busbars inside the MNPV6 accommodate up to 14 wires while the MNPV3 accommodate 6. By the way, don t ever open a touch safe fuse holder under load!!! The following pictures are the result of a 250 volt array that had only 5 amps flowing through it when the fuse holder was opened. This fuse holder is UL listed to 1000VDC and 30 amps. It does say Do not open under load. It s a good thing we build our combiners out of metal. The arc and fire lasted for about two full minutes until it burned out. The upcoming 250VDC MidNite Classic controller presents some problems. There will be consumers installing this high voltage controller. We highly recommend professional installation. The pictures above show a very real issue. MidNite has addressed this potential problem by creating high voltage circuit breakers and new combiners to house the new breakers. The high voltage breakers are UL listed at 250VDC. MidNite has employed ETL to conduct tests to bring the listing up to 300VDC.

Notice the copper plate at the bottom of the high voltage breaker. The input and output of this breaker is from the top surface. The breaker is essentially two of our 150VDC breakers in series. They are internally ganged so when one pole trips, the other also trips at the same time. It is not sufficient to handle tie two 150VDC breakers externally. They would not withstand the high voltage. High voltage arcing tends to weld internal contacts together so when you need the breaker to trip, it would in fact fuse itself in the on position. That could ruin your entire day or worse, so use the breakers that are designed for this extreme high voltage DC. The following picture shows six 300VDC breakers installed in the MNPV12 250. The large reliefs in the busbars allow PV wiring to easily enter the upper left pole of each breaker. These 168 amp busbars may be combined as shown or set up as two separate systems with three each high voltage breakers. The high voltage breakers currently stocked are 10A, 15A and 50A. Additional values are on order so check with us for available current ratings. These are very custom breakers with long lead times, so be aware not all values may be available for a while. These breakers are only available from MidNite Solar. List price for a 300VDC breaker is $34.00. This is the regular MNPV12 combiner with the dead front and metal cover removed. In this picture the reversible busbar is combining ten touch safe fuse holders. The 200 amp busbars can be configured for up to 12 150VDC breakers or 10 fuses either separated into two systems or combined as shown. The MNPV12 and MNPV12 250 has recently passed ETL testing. Notice the picture of the MNPV12 deadfront to the right. You will notice a snap in adapter for use with fuse holders. Each combiner comes with the main large deadfront and two fuse holder adapters. This combiner with its 200 amp busbar is well equipped to handle the newer more powerful PV modules. Most existing combiners can t handle a bunch of 20 amp breakers or fuse holders. MNPV16: This new combiner has also passed ETL testing (December 08). It is intended for use with up to 16 touch safe fuse holders. The current rating is 240 amps. It can accommodate up to 250MCM output wires. There is plenty of room for PV and ground wiring. The input knockouts are concentric ½ / 7/8

knockouts. The ½ inner knockout can be used to install bulkhead mounted MC connectors for ease of installation at the jobsite. See pictures below. MNPV12 chassis showing concentric knockouts MNPV16 with bulkhead mount MC connectors The MNPV16 can be used with up to twenty four 150VDC circuit breakers or 12 300VDC breakers. Each version requires a different busbar arrangement, so different model numbers apply MNPV16 is for 16 600VDC fuse holders MNPV16 150 is for 24 150VDC circuit breakers MNPV16 250 is for 12 300 volt breakers Go to www.midnitesolar.com to get wiring diagrams for each specific application. Midnite Solar 17722 67 th Ave NE unit C Arlington, WA. 98223 USA PH: 425 374 9060 The arc here is from only 165 VDC. This arc is quenched inside the circuit breaker. A 300 VDC arc is only going to be worse. Any volunteers to run the ETL test?

MNPV12 250 MNPV16 WITH FUSE HOLDERS MNPV12 250 MNPV12 WITH 150VDC BREAKERS

MNPV6 MNPV6 MNPV6 WITH 250 BUSBARS MNPV3