For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.



Similar documents
3873P01. Room controllers. For fan-coil applications FC-10, FC-11, FC12 with Konnex bus communications (S-mode and LTE mode)

Digital input modules

TX OPEN RS232/485 module

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Building Technologies

PCS0100en Persy Control Services B.V. Netherlands

OZW V2.0. Web server. Synco TM, Synco TM living

RRV934. Multi-controller. Synco living

HERZ-Thermal Actuators

Air damper actuators

VAV compact controller KNX / PL-Link

OZS Web server. For LPB/BSB plants

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

OZW V4.0. Web server. For Synco TM, Synco TM living

PXM20-E. Operator unit DESIGO PX

VAV compact controller KNX / PL-Link

ACS-30-EU-EMDR-10-MOD

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

OZW30. Central Unit SYNERGYR

MINI MCR-SL-R-UI(-SP)

ABB i-bus KNX Fan Coil Controller FC/S 1.1

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Electronic Control Devices The European Product Catalogue 2007

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Three-phase monitoring relay CM-PFE

Duct Humidity Transmitter

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Product and functional description

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Heating Controller. Building Technologies HVAC Products

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CompactLogix Power Supplies Specifications

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RM4TG20 three-phase network control relay RM4-T - range V

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic Control Devices The European Product Catalogue 2007

PHOENIX CONTACT Features

SKR - industry relay

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Drayton Digistat +2RF/+3RF

49 Series - Relay interface modules A. Features

Flush-mounted room thermostats

Safety technique. Emergency stop module BO 5988 safemaster

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

HMI display Installation Guide

Proportional pressure regulators VPPE

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Adjustable room thermostat for heating only or cooling only systems

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Modular I/O System Analog and Digital Interface Modules

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

ABB i-bus KNX SA/S Switch Actuators Product Manual

IntesisBox KNX Mitsubishi Heavy Industries AC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation guide H A. HSI hardwired system interface

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

AXIS T81B22 DC 30W Midspan

Redundancy Module QUINT-DIODE/40

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Quick Connect. quick - simple - efficient.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Model: DC-A2IO Advanced HVAC Controller

IntesisBox KNX - LON

Contents. Document information

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

IntesisBox Modbus Server SAMSUNG Air Conditioners

Safety Manual BT50(T) Safety relay / Expansion relay

PNOZsigma - Base units

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Problem / Solution. The problem:

Application/Connection Examples

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Transcription:

s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems, with or without change-over PI control Proprietary bus communication Integration into the DESIGO building automation and control system via PX KNX 0 10 V control of valve actuators, fan, and electric heating coil Volt-free relay contacts for release of the fan and the electric heating coil Commissioning with "HandyTool" or Synco ACS AC 230 V operating voltage Screw terminals CM2N3876en_04 17 Feb 2010 Building Technologies

Use The RX39.1 room controller is optimized for control of fan-coil systems in individual rooms. The application of each controller is determined by the application software. The controllers are delivered with a fixed set of applications. The relevant application is selected and activated during commissioning using one of the following tools: "HandyTool" (the QAX34.3 room unit includes a tool function which allows you to set the parameters of the connected RX controller) Synco ACS Functions The room controller functions are determined by the selected application, its parameters, and by the input/output configuration. For details, refer to the FNC description of functions, document CM110788. When DESIGO RX controllers are integrated into a building automation and control system, or into a Synco system, additional functions become available such as time scheduling, central control of setpoints, etc. Applications The following applications are available for the RX39.1 room controller: Application group (type) Fan-coil applications SP-03 FNC02 2-pipe system with changeover FNC03 FNC04 2-pipe system with changeover and electric re-heater 4-pipe system Note Only one application at a time can be activated with the tool ("HandyTool" or Synco ACS). Ordering Product number Stock number Designation ASN SSN Product designation RX39.1/SP-03 S55373-C100 Room controller Equipment combinations The RX39.1 room controller is compatible with field devices from Siemens Building Technologies. For details, refer to the DESIGO RX hardware overview, CA2N3804 and the valve actuator documentations CA1N4864 / CA1N4891. 2 / 12

Technical design The RX39.1 controller consists of a housing base, a housing cover and the printed circuit board with connection terminals. The controller also has a tool socket, a programming ED and a programming button. 80048 Cable restraints Connection terminals Plug-in connection terminals for bus Cover Housing base Connection terminals Programming ED Programming button Tool socket Programming ED The Programming ED shows the operational status of the room controller as follows: Green, flashing Red, ON Orange / green, flashing OFF Other patterns Normal operation. Programming mode for address assignment (ACS). Fault Startup phase. No application selected. oading. Download from ACS. Room unit QAX34.3 in HandyTool mode. No supply voltage Fault After switching on the operating voltage, the controller flashes in different patterns for 3 to 5 seconds. If other patterns appear during normal operation, this indicates an error. Programming button The programming button is used to identify the controller in the commissioning phase. Pressing this button causes the red programming ED to light up and remain on until identification of the controller is complete. Once the programming button has been pressed, the tool overwrites the hardware address in the room controller. If there are no terminal covers fitted, the programming button may be operated only by a qualified electrician. The adjacent terminal may be a live mains voltage conductor. 3 / 12

Terminal cover Terminal covers (RXZ30.1) are available as an option, to protect the connection terminals from physical contact and dirt. The programming ED remains visible when the terminal covers are in place, and the programming button can be operated with a pointed implement. The cable is connected to the room controller by breaking out the perforated cable entry guide. 80049 Removing the terminal cover abel Bar code, Code 39 (ID number) Test date, series (Z, A, B, C ) Serial No. 3876Z06 Observe the warning notes in this data sheet Temperature range (0 50 C) Protection standard Neuron ID Definitively loaded application ocation 091112A 33725 T50 IP20(30) 001086169900 Note Options for use of the labeling fields Appl. and oc. : Handwritten identification of the location and the activated application group. Connection terminals The connection terminals for the bus are detachable plug-in screw-terminals. All other terminals are fixed. To avoid incorrect wiring, terminals which can be connected to AC 230 V (relay outputs) are physically separated from the other terminals. The cable restraints on the housing base must be used for the connections to terminals 19... 27 (AC 230 V). The conductors must be secured with cable ties (see diagram). 3876Z04 4 / 12

Communication The RX39.1 controller communicates with other devices via the following interfaces: interface (proprietary) for the exchange of data with the room units (terminals CE+ and CE-) for communication with: PX/KNX interface (to DESIGO INSIGHT) Interface OCI700 (to Synco) Other DESIGO RX controllers Connecting the tool To facilitate commissioning, the tool Synco ACS can be connected at three different points (marked (A) in the diagram) in the plant: to the bus cable at any point to the RX39.1 controller (RJ45 tool socket) to the room unit (RJ45 tool socket) A RX39.1 CE+ CE CP CP+ CE+ CE Tool A Siemens connecting cable CP CP+ C+ C QAX3... RXZ90.1 B HandyTool QAX34.3 Tool B A HandyTool QAX34.3 Siemens connecting cable A USB Siemens OCI700 3876A05en ACS Notes Caution! The tool socket is a proprietary socket. A Siemens connecting cable must be used (e.g. PXA-C1). When connected to Ethernet, the device on the other end may be damaged! The ACS tool, even if connected to a tool socket, requires an interface (OCI700). The "HandyTool" is connected to the tool socket of the room controller or to the tool socket of the room unit (QAX, RXZ90.1) (B). If you use OCI700 as an interface, it is connected to the service plug of the controller or of the room unit. As long as the OCI700 is connected to the service plug, it must be supplied by the computer via the USB interface. Otherwise the CD display of the room unit will turn dark and the controller will switch to addressing mode. 5 / 12

Disposal The device is classified as waste electronic equipment in terms of the European Directive 2002/96/EC (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Engineering notes Topology Cable length Cable type Number of RX Controllers per Network supply terminator Tree, line, or star NO closed loops Max. 1000 m (sum of all cables of a line (for details refer to document CM110381) E.g. YCYM 2 x 2 x 0.8 mm Max. 45 Up to 45 RX-controllers: ACX95.320/AG or 5WG1 125-1AB11 Not required AC 230 V supply cables The RX39.1 room controller operates with a mains supply voltage of AC 230 V. The sizing and fuse protection of the power supply cables depend on the total load and on local regulations. Connection terminals for the supply voltage are duplicated, so that the supply cables can be looped on the controller. The cables must be secured with cable restraints. Different phases may be connected to the terminals 21 (), 23 (Q13) and 26 (Q33). All AC 230 V conductors must be secured with cable ties. Volt-free relay outputs AC 230 V The volt-free releasing relay output for the fan allows the switching of a load up to AC 250 V, 5(4) A. The volt-free releasing relay output for the heating coil switches a resistive load up to 1.8 kw, max. 10 A. The circuits must be externally fused ( 10 A) as there are no internal fuses. The cables connected to the room controller must be secured with cable ties. DC 0...10 V outputs Valve actuators Fan control The DC 0 10 V control outputs YC1, YC2 deliver max 1.5 ma. The AC 24 V supply output G (next to YC2) delivers max. 6 VA. The DC 0 10 V control output YC3 delivers max 1.5 ma. AC 24 V supply for field devices (G) The controlled devices (valve and damper actuators) receive their power directly from the room controller. This means that a separate AC 24 V supply is only necessary for the field devices require more than a total of 6 VA. 6 / 12

Mounting The room controllers can be mounted in any orientation, and fixed as follows: 80060 80061 Rail mounting The housing base is designed for snapmounting on DIN rails, type EN50022-35x7.5 (can be released with a screwdriver) Surface mounting There are four drill holes for screwmounting (see Dimensions for drilling template). The housing base is fitted with raised supports. When mounting note the following: The controller should not be freely accessible after mounting. It must be mounted in a cabinet or behind a cover that can only be opened / removed with a key or a tool. Ensure adequate air circulation to dissipate heat generated during operation. Easy access is required for service personnel ocal installation regulations must be observed. Mounting instructions and a drilling template are printed on the controller packaging. Commissioning The RX39.1 room controller is commissioned with one of the following tools: Synco ACS via the OCI700 interface "HandyTool" via abeling Function test The definitive application and the controller's location are handwritten in the labeling fields "Appl." and "oc" in the commissioning stage. A special test mode (HandyTool) is available for operation of the outputs and interrogation of the inputs. 7 / 12

Technical data Power supply Operating voltage AC 230 V +/-10 % Rated voltage AC 230 V Frequency 50/60 Hz Power consumption with connected field devices Max. 12 VA Internal fuse Thermal, non-resetting Operating data Control algorithm PI Inputs (SEV) Signal inputs D1 D4 Quantity 4 (for volt-free contacts) Contact voltage DC 16 V Contact current DC 5 ma Contact transfer resistance Max. 100 Contact insulation resistance Min. 50 k Switch time: min. 20ms ON, min. 20ms OFF Measured value input B1 Compatible temperature sensors G-Ni 1000 Quantity 2 Measuring range 0 50 C Sensor current 0.5 ma Resolution 0.1 K Measuring error at 25 C sensor temp. (without cable) max. 0.5 K Outputs (SEV) DC 0 10 V YC1, YC2, YC3 Quantity 3 Resolution 3 mv Accuracy 100 mv Output current Max. 1.5 ma Supply output G (SEV) Voltage / Max. load AC 24 V / Max. 6 VA Relay outputs Q34 (fan release) Quantity 1 (N/O contact) Relay type Monostable Contact rating with AC voltage Switching voltage Max. AC 250 V, min. AC 19 V Nominal current, resistive/inductive Max. AC 5(4) A (cos = 0.6) Making current 200 ms half-time Max. 20 A Switching current at AC 19 V Min. AC 10 ma Contact rating with DC voltage Switching voltage Max. DC 250 V, min. DC 5 V Switching current at DC 5 V Min. DC 100 ma Switching capacity Max. 20 W Inductive load /R Max. 7 ms External fuse (essential!) Max. 10 A Q14 (heater release) Quantity 1 (N/O contact) Relay type Monostable Contact rating with AC voltage Max. admissible load (resistive only) Max. 1.8 kw External fuse (essential) Max. 10 A Ports/interfaces Interface to room unit Number of room units connectable 1 Interface type for room unit for ACS baud rate 4.8 kbit/s Baud rate on the bus 9.6 kbit/s Interface type Electrically isolated current 5 ma Baud rate bus 9.6 kbit/s topology Refer to Engineering, page 6 8 / 12

Cable connections Connection terminals for signals and power supply Solid or stranded conductors 0.25 2.5 mm 2 or 2 x 1.5 mm 2 connection terminals (plug-in screw terminals) Solid or stranded conductors 2 x max. 1.0 mm 2 e.g. YCYM 2x2x0.8 Single cable lengths For field devices, see also the RXB / RX installation guide, CA110381 Signal inputs D1 D4 Max. 100 m with diameters 0.6 mm Measured value input B1, B2 Max. 100 m 0 10 V outputs YC1, YC2 (valve actuators) Max. 100 m where A 1.5 mm 2 0 10 V outputs YC3 (fan) Max. 100 m where A 1.5 mm 2 Relay outputs Q14, Q34 Depends on load and local regulations Interface to room unit Max. 115 m where A= 0.75 mm 2 (including connecting cable for tool) Cable type 4-core, twisted pair, unscreened Max. 1000 m (see Engineering, page 6) Tool connecting cable Max. 3 m Housing protection standard Protection standard to EN 60529 IP30 with terminal cover fitted and wall mounted without DIN rail IP20 for all other mounting arrangements Suitable for use in systems with protection class I or II Protection class Ambient conditions Normal operation Class 3K5 to IEC 60721-3-3 Temperature 0 50 C Humidity < 85 % r.h. Transport Class 2K3 to IEC 60721-3-2 Temperature 25 65 C Humidity < 95 % r.h. Industry standards Product standards Automatic electronic controls for household and similar use EN 60730-1 Electromagnetic compatibility Immunity (industrial & residential) EN 60730-1 Emission (residential) EN 60730-1 CE marking: Environmental compatibility EMC Directive 2004/108/EC ow Voltage Directive 2006/95/EC N474 C-Tick conformity (EMC) AS/NZS 61000-6-3 The product environmental declaration CM1E3841 contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) Dimensions See dimension diagrams Weight excluding packaging 0.560 kg including packaging 0.600 kg ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS) 9 / 12

Connection terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 CP CP + CE + CE 3876A08 B1 M D1 GND D2 T AC 230 V 24... 230 V 10 A 5(4) A QAX... 2 1 4 3 N N Q13 Q14 Q33 B2 D3 GND D4 N.C. YC1 G YC2 YC3 CE + CE Ni1000 0... 10 V N.C. AC 24 V Q34 0... 10 V 0... 10 V 19 19 21 21 23 24 25 26 27 29 30 31 32 Measured value input B1 1 Measured value input for G-Ni 1000 sensors M 2 Measured value input ground B2 3 Measured value input for G-Ni 1000 sensors Signal inputs D1 4 Signal input GND 5 Signal ground D2 6 Signal input D3 7 Signal input GND 8 Signal ground D4 9 Signal input N.C. 10 Do not use this terminal as an auxiliary terminal! 0 10 V outputs YC1 11 0 10 V Heating control signal 12 Signal ground G 13 AC 24 V max. 6 VA YC2 14 0 10 V Cooling control signal (heating / cooling in case of changeover) 15 Signal ground YC3 16 0 10 V Fan control signal (plug-in connection) CE+ 17 CE 18 Power supply N 19 Neutral conductor 21 Phase conductor AC 230 V +/- 10 % Relay outputs Q13 23 Feed for Q14 Q14 24 Normally-open contact, max. AC 250 V, 1.8 kw, max. 10 A (Electric heating) Q33 26 Feed for Q34 Q34 27 Normally-open contact, max. AC 250 V, 5(4) A (controlled fan) Room unit CP 29 ground CP+ 30 data CE+ 31 CE 32 Caution Tool socket Observe the technical data for the relay outputs: max. AC 250 V, 5 (4) A External fuse (essential!): max. 10 A ocal installation regulations must be observed. Proprietary RJ45-type tool socket 1 2345678 1 (CE+) 2 (CE ) 3 Not used 4 Not used 3206Z01 5 +12VDC 6 RxD 7 (CP+) / TxD 8 (CP ) 10 / 12

Connection diagrams N1 Connection of field devices, room unit, bus and power supply B1 M B2 D1 GND D2 1 2 3 4 5 6 T T B1 B2 D1 D2 D3 GND D4 N.C. YC1 G YC2 7 8 9 10 11 12 13 14 Y G G Y M M D3 D4 Y1 Y2 Y 0 N Q2 YC3 15 16 0 Y N Q1 CE + CE 17 18 19 G G 19 21 21 N AC 230 V Q13 23 Q14 24 N.C 25 Q33 26 Q34 27 CP CP + CE + CE 29 30 31 32 2 1 4 3 B3 3876A11 N1 RX39.1 B1, B2 G-Ni 1000 temperature sensor D1 D4 Volt-free contacts (window contact, occupancy sensor, etc.) Y1 0 10 V valve actuator heating Y2 0 10 V valve actuator cooling (heating / cooling in case of changeover) Q1 Controlled fan Q2 Electric heating (solid state relay) B3 QAX room unit Twisted pair For Q2 (1.8 kw max. resistive load), use additional external fuses of max. 10 A to protect the PCB tracks. Note For information on the compatibility of field devices with the RX39.1 room controller, refer to the various application descriptions (see the FNC description of functions, document CM110788). 11 / 12

Dimensions Dimensions in mm Without terminal covers 3876M01 35,3 90 110 62 3,9 1 With terminal covers 50 6 35,3 3,9 62 1 161 152 3876M02 120 Drilling diagram 80056 100 135 12 / 12 2009-2010 Siemens Switzerland td Subject to change