Table of Contents GEN III SYSTEM PARTS...1 REMOTE SYSTEM BOM (Booster)...1 (Conventional)...3 Hardware and Controls...4 Harnesses and Sensors...5 Hydraulics...6 Miscellaneous...7 TRANSFER PARTS (GEN II TO GEN III)...7 Contact Information: Mixer & Plant Parts PO Box 12219 Rock Hill, SC 29731 Bus: (803) 233-7913 Fax: (586) 601-1904 readymixparts.com
GEN III SMART SYSTEM-BOOSTER Description Quantity Units Part Number PUMP - HYD, CLOCKWISE HYDROIC (EP) 1 EA 30386328 PUMP - HYD, BOOSTER AXLE CLOCKWISE ROT 1 EA 30389205 VALVE - HYD, BLOCK VBL-CLC-01 1 EA 10194869 VALVE - HYD, BLOCK VBL-BCP-01-230 1 EA 10194886 VALVE - HYDRAULIC PRESSURE CONTROL (Q2G0 1 EA 10200209 ENCLOSURE - MIXER, CAB, GEN III 1 EA 30380835 RADIO - TRANS, MIXER GEN III 1 EA 30380836 ENCLOSURE - MIXER D160 GEN III 2 EA 30380837 ENCLOSURE - MIXER GROUND MOD GEN III 1 EA 30380838 OIL, MIXER WITH 160F TEMP. SWITCH AND RE 1 EA 30386360 ANGLE - BRACKET, CABLE MOUNT, DRUM CONTR 1 EA 30356823 PROTECTION - VEC, MIXER, GEN III 1 EA 30380822 PLT - MOUNT OMNEX CONTROL 2 EA 30386545 MOTOR - HYDRAULIC,MODEL 4633-135,W/ QUAD 1 EA 30386500 ENCL - CABINET, 400 X 200 X 80 1 EA 30386883 OPER - SENSOR, PROXIMITY W/6" CABLE 3 EA 30350926 LED - INDICATOR LIGHT STRIP 1 EA 30386786 HRNSS - MIXER, VEC, REMOTE GEN III 1 EA 30380810 HARNESS - MIXER MAIN GEN III 1 EA 30380809 HARNESS - ICC MIXER STAND, CPL 1 EA 30380811 WMT - MOUNT POST IN CB OMNEX 1 EA 30386547 BOOSTER LIGHTING TRUCK MIXER 1 EA 30389128 PROTECTION - FUSE, 5A/32V, MINI 1 EA 30369488 KIT - FLANGE 1" CODE 61 5151HK-16 2 EA 30307799 FITTING - HYD, ELBOW 45 DEG 1" 61 FLANGE 1 EA 30389371 FITTING - HYD, ELBOW 37 DEG MALE 3/4" 1 EA 30389166 FITTING - HYD, ELB 90 DEG 1" FLANGE 61 1 EA 30389370 FITTING - HYD, ELB 90 #16 SWIVEL X FLARE 1 EA 30389486 FITTING - HYD, #16 ORB TO #16 FLARE 1 EA 30389365 FITTING - HYD, ELBOW #16 ORB X #16 FLARE 1 EA 30389357 FITTING - HYD, ELBOW #16 ORB X #16 FLARE 1 EA 30389357 FITTING - HYD, ELBOW #16ORB X #12 FLARE 1 EA 30389358 FITTING - HYD, MALE #8 SAE X #10 1 EA 30389213 FITTING - HYD, ELBOW 37 DEG MALE 3/4" 2 EA 30389166 FITTING - HYD, MALE 3/8" X 1/2" 37 DEG 2 EA 30389170 FITTING - HYD, ELBOW #10 ORB X #8 FLARE 1 EA 30389390 FITTING - HYD, MALE #12 SAE 2 EA 30389210 FITTING - HYD, TEST PLUG SAE#4 1 EA 30335096 FITTING - HYD, UNION 3/4" SAE 2 EA 30389162 FITTING- HYD, 12 ORB TO #8 FLARE 2 EA 30389465 FITTING - HYD, ELBOW 37 DEG 3/8" 2 EA 30389160 FITTING - HYD, ELB 90 #6 SWIVEL X FLARE 1 EA 30389374 FITTING - HYD, #4 ORB TO #6 FLARE 1 EA 30389466 continued on next page.. 1
Description Quantity Units Part Number FITTING - HYD, ELB 37 DEG MALE 1/4" 1 EA 30389169 FITTING - HYD, MALE #8 SAE X #6 1 EA 30389434 FITTING - ELBOW LNG #8ORB TO #8 FLARE 1 EA 30386265 FITTING - HYD, #4 ORB TO #4 FLARE 1 EA 30389463 FITTING - HYD, ELBOW #6 ORB X #8 FLARE 1 EA 30389435 CARTRIDGE SUN CKCB-XCN 1 EA 30391007 ENCL - TERMINAL BOX, 7-TERMINAL MIDLAND 1 EA 30346562 ANNC - ALARM BACK-UP 12V 1 EA 30337019 HARNESS - BACKUP ALARM, MIXER, (Q3G06) 1 EA 30359462 CARTRIDGE SUN CKCB-XCN 1 EA 30391007 REFLECTOR - DECK EDGE BLACK (Q7C13) 1 FT 30302690 2
GEN III SMART SYSTEM-CONVENTIONAL Description Quantity Units Part Number PUMP - HYD, CLOCKWISE HYDROIC (EP) 1 EA 30386328 VALVE - HYD, BLOCK VBL-CC-01 1 EA 10194874 ENCLOSURE - MIXER, CAB, GEN III 1 EA 30380835 RADIO - TRANS, MIXER GEN III 1 EA 30380836 ENCLOSURE - MIXER D160 GEN III 2 EA 30380837 ENCLOSURE - MIXER GROUND MOD GEN III 1 EA 30380838 OIL, MIXER WITH 160F TEMP. SWITCH AND RE 1 EA 30386360 ANGLE - BRACKET, CABLE MOUNT, DRUM CONTR 1 EA 30356823 PROTECTION - VEC, MIXER, GEN III 1 EA 30380822 PLT - MOUNT OMNEX CONTROL 2 EA 30386545 MOTOR - HYDRAULIC,MODEL 4633-135,W/ QUAD 1 EA 30386500 ENCL - CABINET, 400 X 200 X 80 1 EA 30386883 OPER - SENSOR, PROXIMITY W/6" CABLE 2 EA 30350926 LED - INDICATOR LIGHT STRIP 1 EA 30386786 HRNSS - MIXER, VEC, REMOTE GEN III 1 EA 30380810 HARNESS - MIXER MAIN GEN III 1 EA 30380809 HARNESS - ICC MIXER STAND, CPL 1 EA 30380811 WMT - MOUNT POST IN CB OMNEX 1 EA 30386547 PROTECTION - FUSE, 5A/32V, MINI 1 EA 30369488 FITTING - HYD, TEST PLUG SAE#4 1 EA 30335096 KIT - FLANGE 1" CODE 61 5151HK-16 2 EA 30307799 FITTING - HYD, ELBOW 45 DEG 1" 61 FLANGE 1 EA 30389371 FITTING - HYD, ELBOW 37 DEG MALE 3/4" 1 EA 30389166 FITTING - HYD, ELB 90 DEG 1" FLANGE 61 1 EA 30389370 FITTING - HYD, ELB 90 #16 SWIVEL X FLARE 1 EA 30389486 FITTING - HYD, #16 ORB TO #16 FLARE 1 EA 30389365 PUMP - HYD, GEAR CHUTE CLOCKWISE ROTAT 1 EA 30389206 FITTING - HYD, ELBOW #16 ORB X #16 FLARE 1 EA 30389357 FITTING - HYD, ELBOW #16ORB X #12 FLARE 1 EA 30389358 O-RING - 79 X 2 1 EA 10042863 FITTING - HYD, ELBOW #8 ORB X #8 FLARE 1 EA 30389462 FITTING - HYD, ELB 90 #8 SWIVEL X FLARE 2 EA 30389436 FITTING - HYD, MALE #8 SAE X #10 1 EA 30389213 FITTING - HYD, #6 ORB TO #6 FLARE 2 EA 30389362 FITTING - HYD, MALE #12 SAE 2 EA 30389210 KIT - FLANGE 1" CODE 61 5151HK-16 2 EA 30307799 ENCL - TERMINAL BOX, 7-TERMINAL MIDLAND 1 EA 30346562 FITTING - HYD, ELB 90 DEG 1" FLANGE 61 2 EA 30389370 ANNC - ALARM BACK-UP 12V 1 EA 30337019 FITTING - HYD, MALE #12 SAE 1 EA 30389210 FITTING - HYD, ELB 37 MALE 1/4" X 3/8" 1 EA 30389167 HARNESS - BACKUP ALARM, MIXER, (Q3G06) 1 EA 30359462 CARTRIDGE SUN CKCB-XCN 1 EA 30391007 REFLECTOR - DECK EDGE BLACK (Q7C13) 1 FT 30302690 3
HARDWARE AND CONTROLS Description Quantity Units Part Number ENCLOSURE - MIXER D160 GEN III 2 EA 30380837 ENCLOSURE - MIXER GROUND MOD GEN III 1 EA 30380838 ENCLOSURE - MIXER, CAB, GEN III 1 EA 30380835 RADIO - TRANS, MIXER GEN III 1 EA 30380836 ENCL - CABINET, 400 X 200 X 80 1 EA 30386883 LED - INDICATOR LIGHT STRIP 1 EA 30386786 WMT - MOUNT POST IN CB OMNEX 1 EA 30386547 PROTECTION - VEC, MIXER, GEN III 1 EA 30380822 ENCL - TERMINAL BOX, 7-TERMINAL MIDLAND 1 EA 30346562 MOUNTED UNDER CAB PROTECTION-VEC, MIXER, GEN III 30380822 MOUNTED IN CAB LED-INDICATOR LIGHT STRIP 30386786 ENCLOSURE-MIXER, CAB, GEN III 30380836 RADIO - TRANS, MIXER GEN III 30380836 WMT-MOUNT POST IN CAB 30386547 4
MOUNTED ON OR NEAR FRONT PEDESTAL Mounted inside cabinet (30386883) Encl - Cabinet, 400 X 200 X 80 30386883 D160 Expansion 30386883 Ground Junction 30380838 HARNESSES AND SENSORS Description Quantity Units Part Number HRNSS - MIXER, VEC, REMOTE GEN III 1 EA 30380810 HARNESS - MIXER MAIN GEN III 1 EA 30380809 HARNESS - ICC MIXER STAND, CPL 1 EA 30380811 HARNESS - BACKUP ALARM, MIXER, (Q3G06) 1 EA 30359462 OPER - SENSOR, PROXIMITY W/6" CABLE 3 EA 30350926 ANGLE - BRACKET, CABLE MOUNT, DRUM CONTR 1 EA 30356823 MOUNTED NEAR DRIVESHAFT OPER-SENSOR, PROX. W/ 6 CABLE 30350926 SENSOR BRACKET FOR DRIVESHAFT AS SHOWN, 30386891 (Part will vary per truck, refer to individual truck BOM for part number) OPER-SENSOR, PROX. W/ 6 CABLE 30350926 ANGLE-BRKT, DRUM CONTR 30356823 5
HYDRAULICS Description Quantity Units Part Number PUMP - HYD, CLOCKWISE HYDROIC (EP) 1 EA 30386328 PUMP - HYD, BOOSTER AXLE CLOCKWISE ROT 1 EA 30389205 VALVE - HYD, BLOCK VBL-CLC-01 1 EA 10194869 VALVE - HYD, BLOCK VBL-BCP-01-230 1 EA 10194886 VALVE - HYDRAULIC PRESSURE CONTROL (Q2G0 1 EA 10200209 OIL, MIXER WITH 160F TEMP. SWITCH AND RE 1 EA 30386360 MOTOR - HYDRAULIC,MODEL 4633-135,W/ QUAD 1 EA 30386500 Hydraulic fittings are particular to Booster and Conventional, refer to BOM section for correct parts PUMP-HYD, BOOSTER CW 30389205 PUMP-HYD, CW HYDROIC (EP) 30386328 OPER-QUAD. SPEED SENSOR 30386642 MOTOR-HYDRAULIC W/ QUAD 30386500 6
MISCELLANEOUS Description Quantity Units Part Number BOOSTER LIGHTING TRUCK MIXER 1 EA 30389128 PROTECTION - FUSE, 5A/32V, MINI 1 EA 30369488 CARTRIDGE SUN CKCB-XCN 1 EA 30391007 ANNC - ALARM BACK-UP 12V 1 EA 30337019 CARTRIDGE SUN CKCB-XCN 1 EA 30391007 REFLECTOR - DECK EDGE BLACK (Q7C13) 1 FT 30302690 TRANSFER PARTS (GEN II TO GEN III) Description Quantity Units Part Number PUMP - HYD, CLOCKWISE HYDROIC (EP) 1 EA 30386328 PUMP - HYD, BOOSTER AXLE CLOCKWISE ROT 1 EA 30389205 VALVE - HYD, BLOCK VBL-CLC-01 1 EA 10194869 VALVE - HYD, BLOCK VBL-BCP-01-230 1 EA 10194886 VALVE - HYDRAULIC PRESSURE CONTROL (Q2G0 1 EA 10200209 OIL, MIXER WITH 160F TEMP. SWITCH AND RE 1 EA 30386360 MOTOR - HYDRAULIC,MODEL 4633-135,W/ QUAD 1 EA 30386500 OPER - SENSOR, PROXIMITY W/6" CABLE 1 EA 30350926 KIT - FLANGE 1" CODE 61 5151HK-16 4 EA 30307799 FITTING - HYD, #16 ORB TO #16 FLARE 1 EA 30389365 FITTING - HYD, ELB 90 #16 SWIVEL X FLARE 1 EA 30389486 FITTING - HYD, MALE 3/8" X 1/2" 37 DEG 2 EA 30389170 FITTING - HYD, ELBOW #10 ORB X #8 FLARE 1 EA 30389390 FITTING - HYD, ELBOW 37 DEG MALE 3/4" 1 EA 30389166 FITTING - HYD, ELBOW #16ORB X #12 FLARE 1 EA 30389358 FITTING - HYD, ELBOW #16 ORB X #16 FLARE 1 EA 30389357 FITTING - HYD, ELBOW 37 DEG MALE 3/4" 1 EA 30389166 7
Schwing Mixer System Gen III Installation / Configuration Manual Transmitter Control Panel I/O Module March 27, 2007 Version 4 DMAN - 3186-01 PO Box 12219 Rock Hill SC 29731 Ph# (803) 233-7913 Fax# (586) 601-1904 Toll Free 1-877-327-2116 DMAN-3186-01 (Rev 1.0) www.omnexcontrols.com call toll free: 1-800-663-8806
DMAN-3186-01 (Rev 1.0) www.omnexcontrols.com call toll free: 1-800-663-8806 2
Table of Contents Safety Precautions... 4 System Overview... 5 Features... 5 T151 Dimensions and Controls... 5 Control Panel Dimensions and Controls... 6 Special Functions... 9 Installation Considerations... 9 Battery Installation and Charging... 9 Power the Transmitter... 11 Test the Transmitter / Control panel Link... 12 Download ID Code... 13 Drum Control... 13 Operating the Control Panel Menu... 14 LCD Contrast Adjustment... 14 Diagnostics T151 Transmitter... 15 Alarms Control Panel... 16 Diagnostics Control Panel... 17 Diagnostics D160 Receiver... 18 Troubleshooting Guide... 19 Parts & Accessories... 23 Specifications... 23 Warranty Information... 23 3
Safety Precautions NOTE: These instructions are intended only for installing and operating the remote control equipment described here. This is not a complete Operator s Manual for the Mixer Truck. For complete operating instructions of the Mixer Truck, please read the Operator s Manual appropriate for your particular model. READ ALL INSTRUCTIONS CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Failure to follow the SAFETY PRECAUTIONS may result in radio equipment failure and serious personal injury Installation PROVIDE A SAFETY CUTOFF SWITCH. If maintenance is required, the radio must be disconnected from power USE PROPER WIRING. Loose or frayed wires can cause system failure, intermittent operation, machine damage, etc. DO NOT INSTALL IN HOT AREAS. This apparatus can be damaged by heat in excess of 158 F (70 C) Personal Safety MAKE SURE MACHINERY AND SURROUNDING AREA IS CLEAR BEFORE OPERATING. Do not activate the remote system unless it is safe to do so. TURN OFF THE RECEIVER POWER BEFORE WORKING ON MACHINERY. Always disconnect the remote system before doing any maintenance to prevent accidental operation of the machine Care KEEP DRY. Do not clean the transmitter / receiver under high pressure. If water or other liquids get inside the transmitter battery or control panel compartment, immediately dry the unit. Remove the case and let the unit air dry CLEAN THE UNIT AFTER OPERATION. Remove any mud, dirt, concrete, etc. from the unit to prevent clogging of buttons, switches, etc. by using a damp cloth. Maintenance / Welding DISCONNECT THE RADIO CONTROL PANEL AND I/O MODULES BEFORE WELDING on the machine the modules are connected to. Failure to disconnect will result in the destruction of the radio control panel and/or modules. 4
System Overview The Schwing Mixer System is a portable, long range, programmable radio remote control system. Designed as a compact and easy-to-use product, this system puts complete control of your mixer where it s needed most, with the operator. It s robust, easy to install and has complete self-diagnostics. The system consists of a portable transmitter, a Contactless Charging control panel, two I/O modules and a ground junction. The Schwing Mixer System uses Frequency Hopping Spread Spectrum (FHSS) technology. FHSS devices concentrate their full power into a very narrow signal that randomly hops from frequency to frequency within a designated band. This transmission pattern, along with CRC-16 error-checking techniques, enables signals to overcome interference that commonly affects licensed radios. The Control Panel and Modules are designed to be powered from a 12VDC or 24VDC system. Each module features up to 19 solid state, high-side driver input / output controls and a reliable E-Stop control. The T151 transmitter comes with 14 digital controls. A unique ID code is used by each T151 to ensure that no two systems will conflict on a job site. Features FCC, ISC, CE approved License free Hand held / weatherproof / ergonomic Contactless Battery Charging Auto Battery Type Detect Transmitter Missing Detection 1200 foot range @ 900 MHz Simple wire-and-use installation Resilient to impact and shock Tether cable included Diagnostic Indicators T151 Transmitter D160 Expansion Control Panel Ground Junction T151 Dimensions and Controls 4.92 Battery / Tether LED Throttle UP / DOWN Active LED Remote ON / OFF 3.75 Hopper UP / DOWN 4.75 Drum START / STOP Drum / DIS Chute LOCK / UNLOCK Chute UP / DOWN 5
Control Panel Dimension and Controls 5.75 Display Constant Speed (Hold for Setup) Charge Status LED 3.75 7.5 Link LED Error LED Status LED RS-485 Mode Control LED Function Select 1. Selecting Functions A. Each Function Select button selects A. the column content directly above it. A highlight box will appear around the function that is currently selected. B. B. Once a column is selected, press the Function Select button a second time to move the highlight to the desired function (Except for Drum Control, see NOTE below). Each press of the button will toggle the highlighted area between the functions. Press once and CHUTE LOCK / UNLOCK is highlighted Press again and CHUTE UP / DOWN is highlighted NOTE: Drum Control functionality operates differently. Please refer to the Drum Control section for precise control operation directions. 2. Turning ON / OFF (Modifying) Functions A. The Mode (Speed) Control buttons selects the top or bottom function within the highlighted group. A. B. B. To change a setting, press the top Mode Control button to select the top function in the highlighted box and press the bottom Mode Control button to select the bottom function in the highlighted box. Press to change from CHUTE UNLOCK to CHUTE LOCK Press to change from CHUTE LOCK to CHUTE UNLOCK 6
Special Functions Installation Considerations NOTE: The FCC and ISC require that the antenna be restricted to that supplied by the manufacturer and approved for use with this product. An optional 0dB coax wire antenna may be supplied. For other antenna options, please contact OMNEX Control Systems ULC Mounting and Installation The I/O Module can be mounted by fastening two ¼ bolts through the two mounting holes in the unit s enclosure. When mounting, ensure that the I/O Module is oriented so that the text is reading right and the connectors are pointing down. When selecting a mounting point for the I/O Module, it is recommended that the location require only a minimal length of wiring to connect it to the control panel, that it will be in a visible area where it has good exposure to the operator and that it is mounted on a surface that is protected from the weather and sustains minimal vibration. It is also recommended that the control panel have the best possible line of sight with the transmitter Power Connections and Wiring Whenever a power connection is made to an electronic device, it is a good practice to make both the Power (+) and Ground (-) connections directly to the Battery and avoid connecting the power from the charging side of existing wiring or making use of existing "ACC" or other peripheral connection points. Make sure that wire of sufficient gauge and insulator type is used when connecting the outputs of the receiver to the control panel. Observe any component manufacturer's instructions and recommendations for proper integration of their product. This includes the power ratings and requirements of such components as relays, valves, solenoids, etc. Be sure to test each of the outputs with a multi-meter prior to connecting the outputs to your end devices. This will ensure that each output has been programmed to operate in the manner required by each end device. Filtering and Noise Suppression Whenever a solenoid or electromagnetic switch is controlled by the receiver, it is a good practice to install a Diode across its terminals to ensure that surges and spikes do not continue back into the circuit. Appropriate 36V Bi-directional Diodes kits can be ordered under the OMNEX part number AKIT-2492-01. 9
Battery Installation and Charging When the control panel has been installed, install batteries into the transmitter. 1. Install Batteries Remove the battery cover on the back of the transmitter using a slotted screwdriver and insert the 4 "AA" rechargeable batteries. Orientation of the batteries is embossed inside the battery housing. No batteries are required when the transmitter is connected to the control panel by a tether cable. NOTE: For operation at temperatures below 10 C, lithium batteries are recommended. Low temperatures reduce battery performance for both alkaline and lithium types. Refer to the battery manufacturer s specifications for detailed information on low temperature performance. T151 Battery WARNING: do not install batteries backwards, charge, put in fire, or mix with other battery types. May explode or leak causing injury. Replace all batteries at the same time as a complete set and do not mix and match battery types. 2. Charge Batteries Place the transmitter in the Charge Cradle. The cradle will detect the transmitter and start charging. The (Charge Status) light on the transmitter will slow flash YELLOW. Fully charge the batteries for 8 hours or until the (Charge Status) light on the transmitter turns solid YELLOW. The charging time may be longer in hot or cold temperature extremes. The (Status) light will be solid GREEN when charging is complete. A. Cradle detects the transmitter and the batteries are charging B. Batteries are fully charged A. B. NOTE: should the batteries need charging during a job, 15 minutes of charging will provide about 3-4 hours of operation, 1 hour of charging should provide approximately 12-16 hours of operation. Tips for best performance: 1. The system was designed to work best with NiMH batteries. Regular alkaline batteries and NiCad batteries will work, however, system performance may not meet all specifications. 2. Charge the batteries at the end of every shift. Temperature extremes (freezing and hot temperatures) will diminish battery performance, therefore, keep the batteries as fully charged as possible at all times to maximize operation time. 3. Charging will not occur when vehicle is shut off. Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 10
Power the Transmitter 1. Turn the Transmitter ON or OFF Refer to the Legend below for diagram details. A. Turn Transmitter ON Press [Remote] UP B. Turn Transmitter OFF Press [Remote] DOWN If the transmitter's (Active) light does not flash, check the battery orientation. Test the Transmitter / Control panel Link Follow these steps to ensure that there is a radio link between the transmitter and control panel. Refer to the Legend below for diagram details 1. Ensure the Transmitter is OFF 2. Power the Control Panel With T151 out of Cradle With T151 in Cradle 3. Power the T151 If the (Active) light on the transmitter is flashing and the (Link) light on the control panel is flashing GREEN, a link between the two exists. If the control panel s (Link) light does not flash GREEN, follow the steps under Download ID Code. The ORIGA system is now ready for use. Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 11
Download ID Code (Use in case of Link Test failure) Follow these steps to download the transmitter s unique ID Code into the control panel. This will allow the control panel to establish a radio link with that transmitter. Refer to the Legend below for diagram details. Refer to Troubleshooting Chart #4 for Tips and Considerations NOTE: It is necessary to download the ID Code when replacing either the transmitter or the control panel. 1. Prepare the Control Panel for Download A. Press & hold [Setup] for 4 seconds until System Control screen appears B. Highlight Link with Remote using [Mode] buttons A. DRUM SPEED 0.0RPM 0 PW M BP 0 PSI DRUM CHUTE THROTTLE BOOSTER ST LK UP UP SP UN DN DN CH UP HOPPER LIGHTS B. USER SETUP BOOSTER ENABLED: YES DRUM TOTAL REVS: 000 RESET WITH REMOTE DISPLAY FIRMWARE VERSION 2. Put Control Panel into Setup Mode A. Press the [Select] button to place the control panel into Setup Mode B. The display should now indicate that the control panel is ready for the download A. B. USER SETUP BOOSTER ENABLED: YES DRUM TOTAL REVS: 000 RESET WITH REMOTE DOWNLOAD FIRMWARE W IT H RE MOT E TO REMOTE RF ID UPLOADING... C. W IT H RE MOT E TO REMOTE RF ID UPLOADING... FAILED NOTE: If left idle in Setup Mode for over 30 seconds, the control panel will time out. The (Link) light and (Status) light will flash RED rapidly and the display will read RF ID UPLOADING FAILED. To return to Setup Mode, Press [ESC] to go back to the main screen and repeat steps 1 and 3. If you do not re-enter Setup Mode, you will need to turn off then turn on the control panel to remove the flashing () and () light condition. 3. Power T151 into Configuration Mode A. Hold [Hopper] switch UP B. Press [Remote] switch DOWN C. Release [Remote] switch D. Release [Hopper] switch. The (Active) light should be flashing. A. B. C. D. 4. Download ID Code NOTE: When downloading a new ID to a receiver, a safety feature requires that the transmitter be in close proximity to the receiver. This will prevent a transmitter from accidentally reprogramming a different receiver in the area. A. Press [Hopper] switch UP and Release B. (Link) light goes to GREEN A. B. TO REMOTE W IT H RE MOT E RF ID UPLOADING... 5. Download Complete A. Once complete, (Link) light goes to RED as the transmitter turns off A. W IT H RE MOT E TO REMOTE B. The display will now indicate that downloading is complete RF ID UPLOADING... COMPLETE Legend Solid Slow Flash Fast Flash Red Green Yellow Alternating Red & Green 12
Drum Control A. Press the [Function Select] button to highlight the Drum control column B. Pressing this button toggles the START and STOP function of the drum A. B. A. Press the top and bottom [Mode] buttons to adjust the drum rotation speed and direction B. Observe the PWM value in the top right corner of the screen to determine increase and decrease direction. A. B. Note: To select DC (Discharge) or CH (Charge), you must toggle between the settings by reducing the PWM value to minimum value. Once this min. value is reached, the controller will toggle directions. Continue pressing the same button to increase the drum speed. Press the opposite button to reduce speed and once min. is reached, the controller will switch directions and now the button will increase the value. A. From the transmitter use the Start/Stop switch to toggle the start/stop function of the drum B. The Charge/Discharge switch works in exactly the same fashion as the [Mode] button on the Control Panel. Once the switch is toggled and the PWM speed hits minimum, the drum will switch direction and the switch will act as a speed control switch A. B. A. Press the [Constant Speed] button to set the drum rotation s RPM to the default setting Note: Constant Speed engages automatically when vehicle speed exceeds 15 mph. A. Note: You can press the [Constant Speed] button from the start position as a quick start function to set the system in motion. Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 13
Operating the Control Panel Menu To access the Control Panel menu, press and hold the [Constant Speed] button for about 4 seconds until the System Menu screen appears Use the [Mode] buttons to move the highlighted area up and down to select the desired Menu item. Press the button under the SEL [Select] to select that menu item Menu Item Descriptions Booster Enable Enables and Disables the booster axle control system Drum Total Revs Monitors and counts the total number of drum revolutions Link with Remote Used to place the Control Panel into Download ID mode. Display Firmware Version Display the software version currently installed in the Control Panel. LCD Contrast View and adjust current contrast setting LCD Contrast Adjustment A. To increase or decrease the LCD Contrast, select the LCD menu item and press the [SEL] button. B. Press the buttons under [-] or [+] to increase or decrease the contrast. Once completed press the [ESC] button to return back to the main screen Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 14
Diagnostics T151 Transmitter Tether connection detected Low battery. Unit will run approximately 10 hours after Battery light starts flashing. Flashing rapidly for 10 seconds indicates a transmitter failure. Normal Operation The Active light will flash several times per second, indicating that the transmitter is sending signals to the control panel. The Active light will remain on momentarily whenever a function changes Normal Operation The transmitter is in Download Mode. Stuck switch detected. Ensure that all switches are in a centered position. The transmitter will not power up when a function is ON. On Power Down Unit is still powered. Check for stuck switches, as the transmitter will not power down when a function is ON. Alternating flash means that the transmitter is in Calibration Mode. The transmitter is in the Control Panel charge cradle and the batteries are charging. The batteries in the transmitter are fully charged. Transmitter is in the powered cradle and attempting to charge but the temperature of the batteries is either above 60 C or below 0 C. Either cool or heat the batteries to bring them within charging temperature A problem with the batteries has been detected. (No batteries, no contact to batteries, nonrechargeable batteries, backward batteries, dead batteries) This is a common error if using alkaline batteries or other non-rechargeable batteries. Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 15
Alarms Control Panel Sensors located throughout the machine provide feedback to the Control Panel. When a parameter is not within acceptable operating range an alarm will sound and the appropriate warning label will appear on the Control Panel screen. The following are the list of alarms in the mixer system. No Signal This is indicated by a NO SIG symbol replacing the Drum Speed RPM indicator. The alarm is activated when the Pulse Counter input from the drum is lost. BP This is indicated by a blinking BP symbol. This alarm sounds when the Booster is being driven down and the Booster pressure has fallen by at least 500 psi. REM This is indicated by a REM symbol located next to the BP indicator. The Control Panel has indicated that the remote control is not in the Charge Cradle and the vehicle is traveling over 15 mph. This is to prevent the driver from leaving the work site and forgetting the remote control outside or on the truck. OIL This is indicated by a OIL symbol located directly under the Drum Speed RPM indicator. This alarm indicates that the oil cooler fan has turned on. BIM Booster in Motion is indicated by a BIM symbol located under the Drum Speed indicator. This alarm alerts the driver that the Booster is either up or down. This lets the driver know not to drive the truck while it is in transition between the up and down position. CHUTE This is indicated by a CHUTE symbol located under the Drum Speed indicator. This occurs when the chute is not in the center and up position. This will let you know if it is safe to move the booster up or not. 16
Diagnostics Control Panel Normal Operation Transmitter is OFF The Transmitter is recognized by the Control Panel cradle and being in the cradle. Output status is correct and the E-Stop relay is open and working properly. Transmitter is OFF The Transmitter is not recognized by the Control Panel cradle as the Transmitter is not in the cradle. Output status is correct and the E-Stop relay is open and working properly. Transmitter is ON The Transmitter is recognized by the Control Panel cradle and being in the cradle. Output status is correct and the E-Stop relay is open and working properly. Transmitter and Control Panel have a radio link. Transmitter is ON The Transmitter is not recognized by the Control Panel cradle as the Transmitter is not in the cradle. Output status is correct and the E-Stop relay is open and working properly. Transmitter and Control Panel have a radio link. Trouble Indicators Note: In some cases, the indicator lights will be different depending on whether the transmitter is on or off. These will be reflected in the () light and () light. Please note the these status lights in the Normal Operation section. Indicator s Description Solution Transmitter - ON When the () light activates, text will appear on the display to indicate the error type. Read the error code to determine what the issue is. Refer to the Alarm Control Panel on page 15 for alarm descriptions. Once determined, correct the issue or refer to Vehicle s Operators Manual to determine the appropriate steps. Transmitter - ON The Control Panel has lost communication with the I/O Modules. Refer to the I/O Module diagnostic indicators to determine module status and refer to the D160 diagnostic page for a solution. If the D160 modules appear to be in working order, check the Control Panel to Module connections. Transmitter - ON Irrecoverable internal fault. Call for service. Transmitter - ON The internal temperature of the cradle is above +60 C (140 F). If possible cool down the cradle to within operating temperature range Transmitter - ON No remote control unit has been linked with the Charge Cradle control panel Download ID code of the remote control to the control panel Transmitter - ON The voltage to the Charge Cradle is not within 9 29 VDC Bring the power supply to within operating parameters Legend Solid Slow Flash 1x / sec Double Flash Fast Flash Red Green Yellow 17
Diagnostics - D160 I/O Module Normal Operation ESTOP FAULT US If the control panel is off, the module is operating properly. ESTOP FAULT US When the control panel is turned on, the Link light (fast flashing) and E-Stop (GREEN) indicates the module is operating properly. ESTOP FAULT US When a function is activated on the transmitter or the control panel, the Fault light will turn on GREEN. This indicates the module is operating properly. ESTOP FAULT US When a latched function is activated then the transmitter is turned off, the Fault light will stay on GREEN. The system was intentionally designed this way, the module is operating properly. Trouble Indicators Note: In some cases, the indicator lights will be different depending on whether the transmitter is on or off. Please note the transmitter status in the Description column for each case. Indicator s Description Solution ESTOP FAULT US The reason is the control panel is not communicating with the module. Refer to Troubleshooting Chart #3 for solutions. ESTOP FAULT US A low battery condition has been detected. To detect intermittent conditions caused by poor or corroded ground or power circuits, the GREEN light will continue to flash for 30 seconds after the condition has been removed. ESTOP FAULT US An internal fault with the E-Stop has been detected. Inspect E-Stop wiring for short circuit. Disconnect E-Stop wire as close to the control panel output as possible. If the Status light changes to: GREEN, a short occurs after disconnection point. Stays flashing RED, send it in for service. ESTOP FAULT US A short to ground or excessive current draw on an output. It is most likely caused by a wiring fault. Ensure transmitter is functioning properly, check status of each output connection: Press each function button and observe Fault. If GREEN, everything is OK. If RED, there is a short in that connection. ESTOP FAULT US The E-Stop output has been connected with one of the other outputs. Follow the wire and check for connections with other wires, disconnect to see if condition clears. If not, call for service. ESTOP FAULT US A wiring short to the battery has been detected. Refer to Troubleshooting Chart #1 for solutions. ESTOP FAULT US The module has detected an internal fault. Refer to Troubleshooting Chart #1 for solutions. ESTOP FAULT US Blown fuse detected. Refer to Page 8 for instructions on how to open the I/O module case to access fuse. Check wiring for shorts or bare spots. If fuses continue to blow, call for service. ESTOP FAULT US The module is powered incorrectly. Most likely cause of this condition is that an output wire or the E-Stop wire has been connected to the power supply while the power wire is disconnected from the power supply. Legend Solid Slow Flash Fast Flash Red Green Yellow Alternating Red & Green 18
Troubleshooting Guide Chart #1 Test the D160 I/O Module Start Initial Condition: Turn transmitter off Cycle power to module (turn off and back on) Problem state: Status RED What is the state of the lights on the module? OK state: Status GREEN Link RED Fault OFF E-Stop RED Note: If there is a short to ground on an output, it is not indicated at this stage. To test for short to ground, refer to the *Fault is RED* procedure at the bottom of this page and follow the instructions. Problem state: Status flashing GREEN & RED The system is wired incorrectly. Most likely cause is one of the input/output wires has been connected to the power source. Go to Chart 2 Is the Status light flashing RED? YES Fuse is blown, change fuse 1. Inspect wiring looking for short circuits (e.g. bare wires) 2. If problem re-occurs, call for service. NO What is the state of the E- Stop light? Problem state: E-Stop Flashing RED Inspect E-Stop wiring looking for short circuits (e.g. bare wires) Disconnect the E-Stop output as close to the receiver output as possible. If the Status light changes to: GREEN, there is a short is the wiring after the disconnection point. Stays flashing RED, call for service. OK state: E-Stop RED Fault is OFF Call for service. What is the state of the Fault light? Fault is Flashing RED There is a short to supply. 1. Disconnect A & B connectors from receiver and check all outputs for power (e.g. bare wires, improper connections) make the correct adjustments 2. Call for service. *Fault is RED* There is a short to ground. Note: This should only occur when the transmitter is on and a function button is pressed. In this case the Status light will be GREEN and will turn RED at the same time as the Fault light. Go to Chart 2 to test the transmitter. If the transmitter is functioning properly, proceed to check the status of each of the output connections: Press each of the function buttons and observe the Fault. If the light turn GREEN, everything is OK. If the turns RED, there is a short in that connection. 19
Troubleshooting Guide (con t) Chart #2 Test the Transmitter T151 Turn off the control panel Ensure there are good batteries in the transmitter Turn on the transmitter What is the state of the lights? OK state: Active light steady for about 3 seconds then goes to fast flash. Battery light OFF E-Stop light OFF Activate a function Go to Chart 3 YES Does the Active light go to solid YELLOW? No light comes on at any time Complete the following steps in order: 1. Check battery orientation 2. Clean battery contacts 3. Check or Replace batteries 4. Call for service NO Either the switch is defective or the switch connection to the circuit board is broken. Call for service Both the Active light and the Battery light flash at the same time Stuck switch: 1. Return all switches to neutral (OFF) position 2. Toggle the switch a few times 3. Call for service Active light is flashing rapidly and Battery light flashing slowly Low Battery Change/Charge Batteries Note: Low batteries will last approximately 10 hours once the Low Battery light begins to flash. Replace /Charge batteries by next shift. Battery light and Active light flash alternately. The transmitter is in Calibration mode 1. Turn unit OFF, then turn back ON 2. If condition persists, call for service. Battery light flashes for 10 seconds then all lights are OFF Press and release E-Stop if the condition persists, then either there is a faulty E- Stop or transmitter failure call for service 20
Troubleshooting Guide (con t) Chart #3 Testing the Transmitter / Control Panel Communication Transmitter: Active light is flashing Control Panel: Status GREEN Link RED What is the status of the lights of both the transmitter and receiver? Transmitter: Active light is flashing Control Panel: Status GREEN Link Flashing GREEN There is no link between the transmitter and receiver Transmitter and receiver should be working properly. The problem may rest with the machine instead of the radio system Call for service Do you have a matched set? (i.e. the transmitter and receiver should have identical ID codes YES Call for service. NO Was the transmitter accidentally swapped with another one on the job site? POSSIBLY Search the job site for the correct transmitter. NO NO Was it found? YES Turn on the transmitter to check if the units function correctly. If not, proceed to Chart 1 The transmitter code may need to be re-downloaded to the receiver!!caution!! Note: Before you proceed with the Download ID procedure located on Page 12, great care and caution must be adhered to. Also, refer to Chart #4 for Tips and Considerations. If by accident, the transmitters have been switched with another unit, by downloading the ID code to a new receiver, it is possible for the transmitter to operate 2 units at the same time (if the original receiver unit is still on the job site). Therefore it must be certain that the transmitter / receiver pair are the correct set. Secondly, once the download procedure is completed, ensure all other units on the job site are stopped. Test the operation of the newly configured set to ensure no other machines on the site work with the same transmitter. Once you are certain that the transmitter / receiver pair are a unique set, continue normal operations. 21
Troubleshooting Guide Chart #4 Considerations when Downloading the ID Potential downloading issues If testing of the control panel and transmitter both show the system as working (Chart 2 & 3), then the transmitter and control panel will both go into Download/Configuration mode. Possible issues could arise during Step 4, the download phase of reprogramming. In this case there are 2 symptoms to look for: 1. The Link light on the control panel will not turn GREEN when the power switch is toggled on the transmitter to download 2. The control panel will time out indicating that it didn t receive a signal from the transmitter within the 30 seconds from the time the control panel was put into Setup Mode. If all indications appear normal during the download phase, test the link by turning on the transmitter (note: the transmitter shuts off after transmitting the ID code in Step 4) 1. If the Link light on the control panel doesn t turn GREEN, the control panel didn t receive all of the information that was sent from the transmitter. Possible Solutions 1. Try the Downloading steps again 2. If this doesn t correct the problem, send both the transmitter and control panel in for service. Note: you could try to determine whether the fault lies with the transmitter or control panel by completing the downloading procedure with a different transmitter. If this step works, then the fault lies with the original transmitter. If not, the fault may lie with the control panel.!!caution!! Note: Before attempting downloading with another transmitter, understand that reprogramming the control panel with another transmitter, could result in two control panels on the job site responding to the one transmitter. If the original transmitter was sent in for repair, Disconnect the control panel (disconnect connector A) to continue using the machine without remote capability and without fear of inadvertently operating the machine with the other transmitter. Connector A 22
Parts & Accessories Part Part Number Description Batteries B0010 4 x AA alkaline T151 Tether Cable (8 m. / 25 ft.) ACAB-2455-02 see illustration Toggle Switch AKIT-1504-04 Honeywell 1TL1-7 Magnet Back AKIT-2498-02 see illustration Bipolar Diode Kit AKIT-2492-01 36V, Bi-directional, Motorols P6KE36CA Fuse F0039 Bussman ATC-15 Socket Connectors J0418 Grey, 12-pin, Deutsch DTM06-12SA J0419 Black, 12-pin, Deutsch DTM06-12SB Wedge J0420 12 pos., Deutsch WM12S Pin J0417 Female, Size 20, Deutsch 0462-201-20141 Sealing Plug J0421 Size 20, Deutsch 0413-204-2005 D160 Connector Kit AKIT-2337-01 Includes Deutsch socket connectors, wedges, pins and sealing plugs. Specifications Size D160 I/O Module 5.1 x 4.7 x 1.4 (130mm x 119mm x 36mm) Weight 0.65lbs (0.295kg) 1.8lbs (0.817kg) DMAN-3186-01 (Rev 1.0) www.omnexcontrols.com call toll free: 1-800-663-8806 23 T151 Transmitter 7.9 x 4.2 x 4.1 (200mm x 125mm x 105mm) Construction High impact plastic, weatherproof High impact, low temperature plastic, weatherproof Input Power +9V to 30VDC 4AA alkaline batteries or NiMH rechargeable Battery Life N/A 160 hours (continuous use) Operating Temperature Range Outputs -40F to 158F (-40C to 70C) -40F to 158F (-40C to 70C) 3A (max) each (sourcing), 10A (max) each (combined) Antenna Internal Internal Approvals FCC Rules and Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part 15.247 ISC RSS 210 Issue 6, Sept. 2005 USA- FCC part 15.247 Canada- ISC RSS 210 Issue 6, Sept. Europe- EN 440 Australia- C-Tick Warranty N/A OMNEX Control Systems ULC warrants to the original purchaser that the OM- NEX products are free from defects in materials and workmanship under normal use and service for a period of ONE YEAR, parts (EXCLUDING: SWITCHES, CRYSTALS, OR PARTS SUBJECT TO UNAUTHORIZED REPAIR OR MODIFI- CATION) and labor from the date of delivery as evidenced by a copy of the receipt. OMNEX's entire liability and your exclusive remedy shall be, at OM- NEX's option, either the (a) repair or (b) replacement of the OMNEX product which is returned within the warranty period to OMNEX freight collect by the OMNEX APPROVED carrier with a copy of the purchase receipt and with the return authorization of OMNEX. If failure has resulted from accident, abuse or misapplication, OMNEX shall have no responsibility to repair or replace the product under warranty. In no event shall OMNEX be responsible for incidental or consequential damage caused by defects in its products, whether such damage occurs or is discovered before or after replacement or repair and whether or not such damage is caused by the negligence of OMNEX Control Systems ULC. MPPM PO Box 12219 Rock Hill, SC 29731 Tel: 803-233-7913 Fax: 586-601-1904 Visit us online: www.readymixparts.com
Contact Information: Mixer & Plant Parts PO Box 12219 Bus: (803) 233-7913 Fax: (586) 601-1904 readymixparts.com