NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For



Similar documents
OBJECTIVE: To measure Chemical Oxygen Demand. BACKGROUND AND PRINCIPLE: SELECTION OF METHODS. Page 1

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Phosphorus, Reactive (Orthophosphate)

1.4 This method is capable of measuring DO in the range of 0.20 to 20 mg/l.

FIVE-DAY BIOCHEMICAL 7.0 OXYGEN DEMAND

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Laboratory 5: Properties of Enzymes

User Guide Dissolved Oxygen Probes

Colorimetric Determination of Iron in Vitamin Tablets

OXIDATION-REDUCTION TITRATIONS-Permanganometry

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Milwaukee USER MANUAL

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Water and Wastewater. Sample Collection and Analysis

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

HS 1003 Part 2 HS 1003 Heavy Metals Test

Development of Advanced Wastewater Treatment and Reclamation System

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Color, True and Apparent

DR/4000 PROCEDURE. CHLORINE, Free

DISSOLVED OXYGEN PROBE

Color, True and Apparent

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

HEXAVALENT CHROMIUM REMOVAL FROM INDUSTRIAL WATSEWATER BY CHEMICAL PRECIPITATION METHOD

Standard methods in water analysis

NITRIC OXIDE and NITROGEN DIOXIDE 6014

6 H2O + 6 CO 2 (g) + energy

Quaternary Ammonium Compounds DOC

The photoionization detector (PID) utilizes ultraviolet

Experiment 8 - Double Displacement Reactions

Solubility Product Constants

ph: Measurement and Uses

Preparation of frequently used solutions

Experiment 12- Classification of Matter Experiment

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Chapter 7 - PHYSICAL AND CHEMICAL ANALYSES

THE ACTIVITY OF LACTASE

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

Santa Monica College Chemistry 11

Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate

Question Bank Electrolysis

Wastewater Nutrient Removal

MOISTURE (Karl Fischer, Buffered)

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia


Solutions and Dilutions

Desalination of Sea Water E7-1

An Introduction to Standards and Quality Control for the Laboratory Barbara Martin

Name: Unit 2- Elements, Compounds and Mixtures and Physical/Chemical Properties and Changes. Elements, Compounds and Mixtures

Enzyme Action: Testing Catalase Activity

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Technologies for Water Pollution Control - Wang Jianlong

WASTEWATER TREATMENT OBJECTIVES

Mixtures and Pure Substances

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Phosphorus Removal. Wastewater Treatment

Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

CHEM 105 HOUR EXAM III 28-OCT-99. = -163 kj/mole determine H f 0 for Ni(CO) 4 (g) = -260 kj/mole determine H f 0 for Cr(CO) 6 (g)

Factors Affecting Enzyme Activity

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

4.2 Bias, Standards and Standardization

Determination of the Mass Percentage of Copper in a Penny. Introduction

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Ion Selective Electrodes

HiPer Ion Exchange Chromatography Teaching Kit

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

Measurement by Ion Selective Electrodes

FT FIELD MEASUREMENT OF RESIDUAL CHLORINE

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Inferred ph in Steam Plant Water Chemistry Monitoring

Welcome to the Understanding Dissolved Oxygen learning module. This section provides information on the following topics:

Classification of Chemical Substances

Cleaning Validation by TOC Analyzer

Physical Changes and Chemical Reactions

WASTEWATER TREATMENT

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

105 Adopted:

Transcription:

NANYANG TECHNOLOGICAL UNIVERSITY School of Civil and Environmental Engineering CV2701: Laboratory 2A Laboratory Manual For Experiment Lab 2A-6(ENV) Wastewater Quality Analysis Location : Environment Laboratory, N1-B3c-49 Session 2004/2005

WASTEWATER QUALITY ANALYSIS - DO, BOD, COD & TOC ANALYSIS 1. OBJECTIVES (i) To correctly perform DO measurements and BOD 5, COD, and TOC analyses for a given set of wastewater samples. To evaluate the BOD 5 /COD, TOC/COD, and TOC/BOD 5 ratios for a given set of wastewater samples. 2. THEORY 2.1 Dissolved Oxygen (DO) All gases of the atmosphere are soluble in water to some degree. Oxygen is classified as poorly soluble, and its solubility is affected both by atmospheric pressure, and physical and chemical properties of water such as temperature, salinity, pollutants, etc. The solubility of atmospheric oxygen in fresh waters ranges from 14.6 mg/l at 0 o C to about 7 mg/l at 35 o C under 1 atm. of pressure. Most of the critical conditions related to dissolved-oxygen deficiency, both in natural waters and biological wastewater treatment, occur during the warmer months when temperatures are high and solubility of oxygen is at a minimum. The low solubility of oxygen is a major factor limiting the purification capacity of natural waters. In aerobic biological treatment processes, the limited solubility of oxygen is also of great importance, because it governs the rate at which oxygen will be absorbed by the medium and therefore the cost of aeration. Hence, DO analysis is a key test both in natural waters and water pollution control practice. 2.2 Biochemical Oxygen Demand (BOD) Biochemical oxygen demand (BOD) is defined as the amount of oxygen required by bacteria while stabilizing decomposable organic matter under aerobic conditions. The BOD test is widely used to determine the pollutional strength of domestic and industrial wastewaters in terms of the oxygen that they will require if discharged into natural watercourses in which aerobic conditions exist. The test is one of the most important both in regulatory work and in studies designed to evaluate the purification capacity of receiving water bodies. Its disadvantage is the long time required by the test, generally taking 5 days. 2.3 Chemical Oxygen Demand (COD) Chemical oxygen demand (COD) is another parameter used widely to measure the pollutional strength of domestic and industrial wastewaters. COD is defined as the amount of oxygen required to oxidize organic matter chemically. Potassium dichromate (K 2 Cr 2 O 7 ) is generally chosen for this purpose due to its strong chemical oxidizing capability. Almost all organic compounds (except for ammonia, aromatic hydrocarbons, pyridine and their related compounds) can be oxidized by dichromate under heated acidic and AgSO 4 -catalysed conditions, equivalent to 95 100% of the theoretical values. 1

One of the main limitations of the COD test is its inability to differentiate between biologically oxidizable and biologically inert organic matter. Nor can it provide any evidence of the biological decomposition rate that proceeds either in natural or man-made conditions. The major advantage of COD test is the short time required for evaluation. The determination can be made in about 3 hr rather than the usual 5 days required for the measurement of BOD. 2.4 Total Organic Carbon (TOC) TOC measures the organic carbon concentration in the water and wastewater. The test can be performed very rapidly (only several minutes) and conveniently (by TOC instrument) and is becoming more popular. For a given wastewater, if a repeatable empirical relationship is established between its TOC and BOD or COD, then measurements in TOC can be used to estimate the accompanying BOD or COD. However, this relationship must be established independently for each set of conditions, such as at various points in a treatment process. 3. EQUIPMENT 3.1 Dissolved Oxygen Probe The use of DO probes or electrodes which allow in-situ measurements to be made has become standard practice in recent years. They are especially useful for taking DO profiles of reservoirs and streams, for monitoring DO levels in aerobic biological wastewater treatment processes, and for conducting BOD analyses. An inert metal such as gold or platinum serves as the cathode, and silver is used for the anode. These are electrically connected with a potassium chloride solution, and the cell is separated from the sample by means of a gas-permeable membrane, usually polyethylene. The membrane shields the cathode and anode from contamination by interfering liquids and solids. When a potential of about 0.5 to 0.8 volt is applied across the anode and cathode, any oxygen which passes through the membrane will be reduced at the cathode, causing a current to flow. The magnitude of the current produced is proportional to the amount of oxygen in the sample. Dissolved-oxygen electrodes are very sensitive to temperature, and thus either temperature measurements must be made along with dissolved-oxygen measurements so that a correction can be applied, or else instruments which are equipped with a thermistor or other device to compensate automatically for temperature changes must be used. 3.2 Biochemical Oxygen Demand The BOD test is essentially a bioassay procedure involving the measurement of oxygen consumed by living organisms (mainly bacteria) while utilizing the organic matter present in a waste, under conditions as similar as possible to those that occur in nature. The requirements of the environmental conditions for the test can be summarized as follows: 2

- Sufficient nutrients, e. g. N, P, S, K, Na, and certain trace elements. - Free from toxins. - Presence of a mixed culture of microorganisms (seed). - Dissolved oxygen must be available in the sample throughout the period of the test. - No interference due to re-aeration. - 20 o C incubation. It is possible to interpret BOD data in terms of organic matter, as well as the amount of oxygen used during its oxidation. This concept is fundamental to an understanding of the rate at which BOD is exerted. Typical BOD 5 values in mg/l for various wastewaters and sewage are given below: Raw Sewage - weak 110 - medium 220 - strong 440 - typical in Singapore 300 350 Primary effluent 150 200 Secondary effluent 20 50 Tertiary effluent 5 10 Raw reservoir water - Kranji 5 15 - Upper Pierce 3 7 3.3 Chemical Oxygen Demand In this test, potassium dichromate is used to oxidize the organic matter. In order for the potassium dichromate to oxidize organic matter completely, the solution must be strongly acidic and is refluxed with a silver catalyst at an elevated temperature. 3.4 Total Organic Carbon TOC analyser is used for measuring the TOC concentration of water and wastewater samples. The analysis actually measures the total carbon (TC) and inorganic carbon (IC) of the sample separately, and the TOC concentration is obtained by difference, i.e. TOC = TC IC. To measure the TC content, the sample for analysis is homogenized (for total TC) or filtered (for soluble TC) and diluted as necessary and a micro-portion of known quantity is injected into a heated reaction chamber packed with an oxidative catalyst such as cobalt oxide. The water is vaporized and the organic carbon is oxidized to CO 2 and H 2 O. The CO 2 is measured by means of a non-dispersive infrared analyzer. The IC content is measured by injecting another micro-portion of the sample into a separate reaction chamber packed with phosphoric acid-coated quartz beads which releases inorganic carbon as CO 2. 4. EXPERIMENT 3

Four wastewater samples are to be analysed in this laboratory session. Each batch of students is required to carry out either total BOD 5 and COD or soluble BOD 5 and COD tests on a particular sample. TOC test will not be conducted but the procedures will be demonstrated to the students. The allocation of samples to each batch is given in Table 1: Wastewater sample Table 1 Sample allocations Total BOD 5 & COD Batch number Soluble BOD 5 & COD Raw sewage 1 2 Combined water 3 4 Primary effluent 5 6 Secondary effluent 7 8 4.1 Dissolved oxygen measurements using DO probe (i) (iii) Remove glass stopper of the BOD bottle, and place DO probe into the sample. Switch on the stirrer of the DO probe. Read the DO value in mg/l when the meter reading has stabilized. 4.2 BOD measurements The following procedure applies to both total BOD 5 and soluble BOD 5 determinations. No dilution is required for samples whose 5-day BOD is less than 6 mg/l. Standard dilution technique should be applied to samples with DO depletion greater than 6 mg/l. The analyst has to decide what dilution should be set for determination of BOD. In most instances, three dilutions will be sufficient to cover the possible range of a sample with unknown strength. The BOD value is not affected by oxygen concentrations greater than 0.5 mg/l. Dilutions that produce a depletion of oxygen less than 2 mg/l should not be used. Hence, it is customary to base calculations of BOD on samples that produce a depletion of at least 2 mg/l and have at least 0.5mg/L of dissolved oxygen remaining at the end of the incubation period. This restriction usually means a DO range of 2 to 6 mg/l. Table 2 presents suitable dilutions prepared by direct pipetting into bottles of about 300 ml capacity. It is customary to estimate the BOD of a sample and set one dilution based upon the estimate. Two other dilutions, one higher and one lower, are also set up. For example, a sample is estimated to have a BOD of 1000 mg/l. From Table 2, a 0.5% mixture should be used. If a 0.2 and a 1.0% mixture are included, the range of measurable BOD is extended from 200 to 3000 mg/l and should compensate for any errors in the original estimate. 4

Table 2 BOD measurable with various dilutions of samples. Using percent mixtures By direct pipetting into 300 ml bottles % mixture Range of BOD (mg/l) 0.01 0.02 0.05 0.1 0.2 0.5 1.0 2.0 5.0 10.0 20.0 50.0 100.0 20,000-60,000 10,000-30,000 4,000-12,000 2,000-6,000 1,000-3,000 400-1,200 200-600 100-300 40-120 20-60 10-30 4-12 0-6 ml 0.02 0.05 0.10 0.20 0.50 1.0 2.0 5.0 10.0 20.0 50.0 100 300 Range of BOD (mg/l) 30,000-90,000 12,000-36,000 6,000-18,000 3,000-9,000 1,200-3,600 600-1,800 300-900 120-360 60-180 30-90 12-36 6-18 0-6 In the direct-pipetting technique, preliminary dilutions should be made of all samples that require less than 0.5 ml of the sample, so that amounts added to the bottles can be measured without serious error. The volumes of all bottles must be known in order to allow calculation of the BOD when this method is used. 4.2.1 Procedure for Standard Dilution Technique (i) Prepare dilution water by adding the following per litre of required dilution water, then aerate to oxygen saturation (approx. 1 hour), - 1 ml phosphate buffer, - 1 ml magnesium sulfate solution, - 1 ml calcium chloride solution, - 1 ml ferric chloride solution, - 2 ml of settled raw sewage seed. Set up three seeded dilution water blanks. Always siphon dilution water into BOD bottles to avoid entrapping air bubbles. Note, BOD 5 of seeded dilution water should range between 0.6~1.0 mg/l. (iii) (iv) (v) Prepare three dilutions for each sample. Measure the initial DO of each diluted sample and blank using a calibrated DO probe. Incubate blanks, the remaining samples at 20 o C for five days. 5

(vi) After five days incubation, measure DO in each bottle by DO probe, and calculate BOD 5 as follows: BOD 5 as mgo 2 (D /L = 1 D 2 ) (B P 1 B where: D 1 = initial DO of sample, mg/l D 2 = Final DO of incubated sample after 5 days, mg/l B 1 = DO of seed control before incubation, mg/l B 2 = DO of seed control after incubation, mg/l P = Decimal volumetric fraction of sample used % seed in D1 volume of dilution water in sample f = = % seed in B1 volume of BOD bottle 2 )f Note: Only consider dilutions where: (1) depletion is 2.0 mg/l, and (2) final DO 1.0 mg/l. If more than one dilution satisfies (1) and (2) above, selects dilution with greatest DO depletion. 4.2.2 Calculation Worksheet Typical examples of worksheet for calculating BOD concentration are shown in Table 3. Enter all your results in the BOD calculation worksheets provided, and attach them with your batch report. 4.3 Chemical Oxygen Demand (using the closed reflux colorimetric method) 4.3.1 Preparation of Samples (i) Turn on the COD reactor. Preheat to 150 o C. (iii) (iv) (v) Remove the cap of a COD digestion reagent vial (Vial type 0-1500 mg/l). Hold the vial at a 45 o angle. Pipette 2 ml of sample into the vial. For greater accuracy, a minimum of three replicates per sample should be analyzed and the results averaged. Close the vial cap tightly. Hold the vial by the cap and invert gently several times to mix the contents. Place the blank and sample vials in the preheated COD reactor. Heat the vials for 1 hour. After 1 hour, turn the reactor off. Invert each vial several times while still warm. Place the vials into a rack and cool for 1 hour at the room temperature. 6

4.3.2 Preparation of Calibration Curve (i) (iii) (iv) Preparation of Potassium hydrogen phthalate (KHP) standard solution: Lightly crush and dry Potassium hydrogen phthalate (KHP) powder to constant weight at 110 o C. Dissolve 425mg of dry KHP in distilled water and dilute to 500mL. The solution has a theoretical COD of 1000 mg/l. Prepare at least five standards from this standard solution with COD equivalents to cover each concentration range (50, 100, 250, 500 and 1000 mg/l). Use distilled water for the calibration blank. Repeat procedure as in Section 4.3.1 for preparation of samples. 4.3.3 Sample measurement (i) (iii) Switch on visible spectrophotometer and set wavelength to 600nm. Enter the value for K factor to 2941. The constant K factor is derived from the standard calibration curve. Pour blank into the glass cell and place it in the sample compartment. Press Autozero key to set the zero absorbance. Discard blank and place the cell containing the digested sample in the measuring position. Close sample compartment lid and press Start key to measure the absorbance. The result will show the direct COD concentration reading of sample measured as mg/l or ppm. 4.4 Total Organic Carbon (This will be demonstration only) (i) (iii) (iv) If a sample contains gross solids or insoluble matter, homogenize until satisfactory replication is obtained. Prepare standard organic and inorganic carbon series by diluting stock solutions to cover the expected range in samples. Inject these standards into analyser. Withdraw a portion of prepared sample using a syringe. Inject samples into analyzer and determine sample carbon concentration. Subtract the inorganic carbon from the total carbon and TOC is determined by the difference. Apply the appropriate dilution factor when necessary. 5 REPORT 7

Enter the test results in the relevant worksheets as in Tables 4 to 6. Submit these results together with the batch report, which includes completion of the following discussion, on the specified submission day. 6. DISCUSSION (1) Using results of the entire group (not batch), calculate the BOD 5, COD, and TOC removal efficiencies of: (a) the primary treatment process based on raw sewage (input) and on primary effluent (output). (b) the secondary treatment process based on primary effluent (input) and on secondary effluent (output). (c) the sewage plant's overall treatment efficiency. (d) comment on the results obtained. Cinput Coutput Note: assess the treatment efficiency as 100% C input (2) Compute the BOD 5 /COD, TOC/COD, and TOC/BOD 5 ratios for the different wastewater samples and comment on the results. July 19, 2004 LAB 2A-6(ENV).doc 8

Table 3 Examples of Worksheet for Calculating BOD Concentration Project: Mass Balance - BOD BOD, as mgo /L = D 1 - D 2 - (B 1 - B) 2 f 5 2 Initial Blanks Final Blanks f = B1-1 : 7.4 B2-1 : 6.6 B2-2 : 7.8 B2-2 : 6.7 B3-3 : 7.7 B3-3 : 6.7 Ave B1 : 7.7 Ave B2 : 6.7 Vol of dilution water in sample Vol of BOD bottle Sample Raw Sewage Secondary Effluent Combined Sewage P Sample No. 1 2 3 4 5 6 7 8 9 Sample Vol (ml) 2 5 10 20 50 100 2 5 10 Bottle Vol (ml) 300 300 300 7.3 300 300 300 300 300 D 1 7.8 D 2 5.0 7.9 7.7 5.8 7.3 6.9 7.0 7.0 6.9 2.3 <1.0 1.5 3.9 1.5 5.0 3.0 1.0 Sample Deplet. (D 1 -D 2 ) 2.8 5.6 3.4 5.4 2.0 4.0 5.9 Average B 1 7.7 Average B 2 6.7 7.7 7.7 7.7 7.7 7.7 7.7 6.7 6.7 6.7 6.7 6.7 6.7 Blank Deplet, (B 1 -B 2 ) (D 1 -D 2 )-(B 1 -B 2 )f 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.8 4.6 2.6 4.73 1.0 3.0 4.9 BOD, mg/l (1.8)(300) 2 (4.6)(300) 5 (2.6)(300) 50 (473)(300) 100 (1.0)(300) 2 (3.0)(300) 5 (4.9)(300) 10 BOD, mg/l 270 276 15.4 14.2 150 180 147 Reported BOD 5, mg/l 276 14.2 147 9

Table 4 Worksheet for Calculation of BOD 5 Concentration Group: Date: (D D ) (B B )f BOD as mgo /L 1 2 1 2 5 2 = P f = % seed in D % seed in B 1 volume of dilution water in sample = 1 volume of BOD bottle Blank/Sample Blank Sample Blank/Sample No. 1 2 3 1 2 3 Sample Vol (ml) Bottle Vol (ml) D 1 D 2 Sample depletion (D 1 D 2 ) Average B 1 Average B 2 Average blank depletion (B 1 B 2 ) (D 1 D 2 ) (B 1 B 2 )f BOD 5, mg/l Reported BOD 5, mg/l 10

Table 5 Combined test results of BOD 5, COD, and TOC of samples from a water reclamation plant Group: Date: Sample Total (mg/l) Soluble (mg/l) Raw Waste Combined Water Primary Effluent Secondary Effluent BOD 5 COD BOD 5 COD TOC Table 6(a) Percent removal efficiencies for total samples Process Total BOD 5 removal (%) Total COD removal (%) Primary treatment process based on raw sewage and primary effluent Secondary treatment process based on primary and secondary effluent Overall treatment plant Discussion on percent removal efficiency of total BOD 5 and COD: 11

Table 6(b) Percent removal efficiencies for soluble samples. Process Soluble BOD 5 removal (%) Primary treatment process based on raw sewage and primary effluent Secondary treatment process based on primary and secondary effluent Soluble COD removal (%) Soluble TOC removal (%) Discussion on percent removal efficiency of soluble BOD 5, COD, and TOC: Table 7 BOD 5, COD, and TOC ratios of wastewater samples Sample Total BOD 5 to COD ratio Soluble BOD 5 to COD ratio Soluble TOC to COD ratio Raw Waste Combined Water Primary Effluent Secondary Effluent Discussion on BOD 5, COD, and TOC ratios: 12