Low viscosity, solvent free elastic adhesive for wood flooring



Similar documents
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. Trowel Grade Polyurethane Elastic Adhesive for Wood Flooring. Technical Data. Typical Mechanical Properties

2-part Epoxy primer, levelling mortar and intermediate layer

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

WOOD FLOORING ADHESIVES

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

PRODUCT DATA SHEET Sika Cable System

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

High-performance, 2-part epoxy anchoring adhesive

Sikagard -203 W (Steridex)

Mapei systems for radiating floor heating with high thermal efficiency

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

SikaBond Adhesive Systems for Floor Coverings. Innovation & Consistency. since 1910

Retail Price List 2015

LATICRETE 290 Premium Floor and Wall Thin-set Adhesive PRODUCT DESCRIPTION

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

12 POLYURETHANE ADHESIVE (PU 105)

Mineral waterproof coating PCI Dichtschlämme

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

Division 9. SignaFlor Pad and Pour Flooring System

2-part epoxy textured roller and seal coat

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Slate Floor Tiling Installation Guide

Wecryl Waterproofing System under surfacing supplied by others

Polymeric membrane for roof waterproofing

Temperature C Cure time to reach hours LSS > 1MPa minutes

Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation

Tecnoepo Flooring System 185

Herringbone Pattern Flooring

SikaProof A Technology

Crystal Clear Sealant

SC2000 CEMENT BONDING PROCEDURES

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

BENTLEY ELEMENTS COLLECTION LVT

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

Two component epoxy paste adhesive

Engineered Hardwood Flooring Installation Instructions

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Euro Oak Installation

Armstrong Do-It-Yourself Tile Installation System

Vinyl Composition Tile Installation System

CLEAN 1. Cleaning and Degreasing Agents. Universal cleaning and degreasing agent

Epoxy Floor Coating Problem Solving Guide

Thermocem. unicem. Mortar additive. Mortar additive. unicem. Thermocem. Substrate preparation. products. Features: Recommended uses:

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

6.1 Schlüter -DITRA. Application and Function

Black epoxy paste adhesive system

weber.floor 4660 Marine Elastic (EN)

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

CHAPTER 3 MOISTURE TESTING

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Carpet Tile Installation Guidelines

How to Install Hardwood Flooring Over a Sub Floor

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

WATERPROOFING SikaProof -A TECHNOLOGY

ENGINEERED FLOORING INSTALLATION

Construction. Sika -1 Waterproofing System. Waterproofing Above and Below Ground for both New and Refurbishment Works

Installation System. Existing Resilient Sheet Floors

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

Minor Cracks in Horizontal Surfaces

REGGAE 30.3x34 cm./11.9"x13.4" D923. Natural Product that might suffer colour variations 1. PROPER PREPARATION OF SURFACE

Installation for Wood Flooring

Tractor Painting Tips

RTV162. Electronic Grade Silicone Adhesive Sealant

PRODUCT DESCRIPTION 29/08/2014

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

Construction. High Performance polyurethane joint sealant. Description. Specifications Satisfied. Uses. Advantages. Instructions for Use

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

DL CHEMICALS DECO SNJF PARAFILL PARQUET EXTERIOR TRANSPARENT STRUCTURE

GigaCrete Specification PlasterMax

Solvent Cementing Instructions For Plastic Pipe & Fittings

3 Marine Adhesives and Sealants

The bonded waterproof membrane, which can be verified by non destructive means DENSARE /14 IHö/JP/KK

How To Level A Subfloor

Mold Preventing I nterior System

PanelTack HM. for the bonding of SVK Ornimat SKG

Guide Specifications for Maple Flooring Systems

3 Scotch-Weld TM. Epoxy Adhesive DP110 Translucent and Gray. Technical Data December, 2009

RESILIENT TILE FLOORING INCLUDING SOLID VINYL AND LINOLEUM FLOOR TILE

PanelTack. For the bonding of steni Colour type 7 façade panels. steni Colour 7. steni Colour 7

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

BLACK JACK ALL WEATHER ROOF COATING

How To Install Hardwood Flooring

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Transcription:

Product Data Sheet Edition 25/06/2012 Identification no: 01 05 02 01 250 0 000009 SikaBond -54 54 Wood Floor Low viscosity, solvent free elastic adhesive for wood flooring Construction Product Description Uses Characteristics / Advantages Environmental Specific Characteristics is a one component, fast curing, solvent free, elastic adhesive for full surface bonding. With : Solid and engineered wood floors (strips, longstrips, planks, panels, boards), mosaic parquet, industrial parquet, lam parquet, wood paving (residential) as well as chip boards, plywood and OSB can be bonded 1-component, ready to use Fast curing properties Excellent workability Floor can be sanded after 12 hrs (+23 C / 50% r. h. Trowel B3 / B11) Elastic, footfall sound dampening adhesive Suitable for most common types of wood floors Especially suitable for problematic woods such as beech, maple and bamboo Suitable for bonding wood floors directly onto old ceramic tiles Reduces stress to the substrate: the elastic adhesive reduces stress transfer between the wood floor and the substrate Suitable for use with sub floor heating Adhesive can be sanded Solvent free Odourless Recyclable tin pail Specific Approvals/Standards EMICODE EC 1 PLUS R, very low emission Specific Ratings LEED EQc 4.1 SCAQMD, Rule 1168 BAAQMD, Reg. 8, Rule 51 passes passes passes 1/5

Product Data Form Colour Packaging Parquet brown 13 kg metal pails (= 10 litre) / 18 kg (3 x 6 kg) / 700 ml Storage Storage Conditions / Shelf Life 12 months from date of production if stored in undamaged, original sealed containers, in dry conditions and protected from direct sunlight at temperatures between +10 C and +25 C. Technical Data Chemical Base 1-part Polyurethane, moisture curing. Density ~ 1,29 kg/l (DIN 53 479) Skinning- / Laying Time Curing Rate Sag Flow Service Temperature Mechanical / Physical Properties ~ 60 minutes (+23 C / 50% r. h.) > 4.0 mm / 24h (+23 C / 50% r. h.) The floor may be walked on / sanded 12 hours (+23 C / 50% r. h. Trowel B3 / B11) after installation, dependent on climatic conditions and the adhesive layer thickness. Consistency: Spreads very easily, trowel marks stable. -40 C to +70 C Shear Strength ~ 1.5 N/mm 2, 1 mm adhesive thickness, tested with beech wood (DIN EN 14 293) (+23 C / 50% r. h.) Tensile Strength ~ 1.5 N/mm 2 (+23 C / 50% r. h.) (DIN 53 504) Shore A Hardness ~ 34 (after 28 days) (DIN 53 505) Elongation at Break ~ 500% (+23 C / 50% r. h.) (DIN 53 504) System Application Details Consumption / Dosage Substrate Quality Full Surface Bonding: 600-700 g/m 2 with notched trowel B3 (acc. to IVK guidelines) (e. g. lam parquet, mosaic parquet and industrial parquet). 600-800 g/m 2 with notched trowel B6 (= P4) (acc. to IVK guidelines) or 3 / 16" 1 / 8" 1 / 8" (engineered strips / planks, lam parquet, mosaic parquet). 600-900 g/m 2 with notched trowel B11 (= P6) (acc. to IVK guidelines), AP 48 or 3 / 16" 3 / 16" 3 / 16" (solid wood, engineered long-strips / panels, industrial parquet, wood paving (residential), chipboards). For bonding of long or wide boards or with uneven substrates it may be necessary to use a notched trowel with bigger notches (to prevent hollow sections). For substrates primed with SikaBond Rapid DPM or Sika Primer MB, the consumption of is reduced. Clean and dry, homogeneous, even, free from grease, dust and loose particles. Paint, laitance and other poorly adhering particles must be removed. Standard construction rules must be observed. 2/5

Substrate Preparation Concrete / cement screed: Must be ground and thoroughly cleaned with industrial vacuum cleaner. Anhydrite screed / Anhydrite flowable screed: Must be ground and thoroughly cleaned with industrial vacuum cleaner shortly before bonding starts. Broadcast mastic asphalt: Must be primed with SikaBond Rapid DPM or Sika Primer MB. Instructions for use, see Product Data Sheet for Sika Primer MB. Glazed ceramic and old ceramic tiles: Degrease, clean with SikaCleaner or grind the tile surfaces and vacuum thoroughly. Wood- / gypsum boards (e.g. chipboards, plywood): Glue / screw the boards to the substructure. They must be fixed to the substrate. For floating sub floors, please contact our Technical Department. Other substrates: Please contact our Technical Department for advice and assistance. can be used without priming on cementitious floors, anhydrite floors, chipboards, concrete and ceramic tiles. For broadcast mastic asphalt, cementitious floors with excessive moisture content and for use over old adhesive residues or on weak substrates use SikaBond Rapid DPM or Sika Primer MB. For detailed instructions consult the Product Data Sheet of Sika Primer MB or contact our Technical Department. Application Conditions / Limitations Substrate Temperature Ambient Temperature Substrate Moisture Content During laying and until has fully cured the substrate and ambient temperatures should be > +15 C and with flo or heating < +20 C. For substrate temperatures the standard construction rules are relevant. Ambient temperature between +15 C and +35 C. For ambient temperatures the standard construction rules are relevant. Permissible substrate moisture content: - 2.5% CM for cement screed (ca. 4% Tramex / Gravimetric weight percent). - 0.5% CM for anhydrite screed. - 3-12% CM for magnesite flooring (dependent on proportion of organic components). Permissible substrate moisture content for use with under floor heating: - 1.8% CM for cement screed (ca. 3% Tramex / Gravimetric weight percent). - 0.3% CM for anhydrite screed. Relative Air Humidity Between 40% and 70%. - 3-12% CM for magnesite flooring (dependent on the proportion of organic components). For moisture contents and the quality of substrates the guidelines of the wood floor manufacturer as well as standard construction rules must be observed. 3/5

Application Instructions Application Method / Tools is applied to the properly prepared substrate directly from the pail and uniformly distributed by notched trowel. Press the wood floor pieces firmly into the adhesive so that the wood floor underside is fully wetted. The pieces can then be joined together using a hammer and an impact block. Many types of wood floors have to be tapped from the top. A distance of 10-15 mm from the wall to the wood floor must be observed. Fresh, uncured adhesive remaining on the wood floor surface must be removed immediately with a clean cloth and if necessary cleaned with Sika Remover-208 or Sika Wipes. Test wood floor surfaces for compatibility with Sika Remover-208 before use. The laying instructions of the wood floor manufacturer as well as standard construction rules must be observed. Cleaning of Tools Clean all tools and application equipment with Sika Remover-208 / Sika Wipes immediately after use. Hardened / cured material can only be removed mechanically. Notes on Application / Limitations is only suitable for use by experienced applicators. If, according to wood floor suppliers or producers deviation from the standards is permissible, temperatures between +5 C and +35 C mu st still be observed for the adhesive. For better workability the adhesive temperature should be at least +15 C. For the proper curing of the adhesive sufficient ambient moisture is necessary. Wood floors in non insulated areas such as basements, or other areas without a damp proof membrane, must only be installed after the application of Sikafloor EpoCem sealed with Sika Primer MB to control the moisture. For detailed instructions consult the Product Data Sheets or contact our Technical Department. For use with chemically pre-treated types of wood floors (e.g. with ammonia, wood stain, timber preservative) and woods with high oil content SikaBond -54 Wood Floor is only to be used with written agreement from our Technical Department. Do not use on PE, PP, TEFLON, and certain plasticized synthetic materials (carry out pre-trials or contact our Technical Department). Some primers can negatively influence the adhesion of (pre trials recommended). When laying bonded wood flooring, always make sure that any wood surface sealer coatings do not come into contact with the adhesive. However if direct contact with the adhesive is unavoidable, then the compatibility of the sealing coats must always be checked and confirmed before use. For further information or assistance please contact your local Sika Technical Department. 4/5

Value Base All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. Construction Health and Safety Legal Notes For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Limited Watchmead Welwyn Garden City Hertfordshire AL7 1BQ United Kingdom Phone +44 1707 394444 Telefax +44 1707 329129 www.sika.co.uk email: sales@uk.sika.com Certificate No. EMS 4308 Certificate No. FM 12504 5/5