User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300



Similar documents
User Guide. Model Insulation Tester / Megohmmeter

User's Guide. True RMS Industrial Multimeter

Ground Resistance Clamp On Tester

Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

Hygro-Thermometer + InfraRed Thermometer Model RH101

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model UT201/202: OPERATING MANUAL. Table of Contents

Ground Resistance Clamp-On Tester

UT202A Operating Manual. Contents

Model UT33A: OPERATING MANUAL Table of Contents (1)

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

10 Multimeter. Users Manual

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

HVAC Clamp Meter. Users Manual

Model UT713 OPERATING MANUAL

7 FUNCTION DIGITAL MULTIMETER

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User's Guide. Pinless Moisture Meter. Model MO257

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Table of Contents. Page

User's Guide. Digital Sound Level Meter. Model

Multi-Function Ground

Integrating Sound Level Meter and Datalogger

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

USER GUIDE. LED Light Meter. Model LT45

RS DIGITAL THERMOMETER

Model UT58A/B/C: OPERATING MANUAL

4-Channel Thermometer / Datalogger

MEGGER Insulation & Low Resistance Tester

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Mini InfraRed Thermometer with Laser Pointer

1. SAFETY INFORMATION

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Water Leak Detection System

Intelligent Digital Multimeters

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Dual Display Digital Multimeter

INTRODUCTION SAFETY PRECAUTIONS/

Temperature Humidity Meter

DET3 Contractor Series

Dual Laser InfraRed (IR) Thermometer with Color Alert

Handheld portable appliance testers

User s Manual Before using the inverter, you need to read and save the safety instructions.

Pocket Tach 99 (PT99) Non-Contact Tachometer

i410/i1010 AC/DC Current Clamp

PowlVac Vacuum Integrity Tester

Model UT71A/B OPERATING MANUAL

User's Guide Integrating Sound Level Datalogger Model

MOUNTING AND OPERATING INSTRUCTIONS

DC POWER SUPPLY ALIMENTATION C.C.

Drayton Digistat +2RF/+3RF

Dual Laser InfraRed (IR) Thermometer

12 Volt 30 Amp Digital Solar Charge Controller

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

TMS TANK MANAGEMENT SYSTEM

Dual Laser InfraRed (IR) Thermometer

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Multi Media Cable Tester TM-901N/TM-902/TM-903

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

Instructions A Amp AC/DC Current Probe

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

EzFlex Combustible Gas Leak Detector Model EZ40

Owner s Manual

T0118 T2118 T3118. Instruction Manual

323/324/325. Calibration Manual. Clamp Meter

Seven function digital multimeter

User Manual for CH-PFC76810

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Owner s Manual & Safety Instructions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Dual Laser InfraRed (IR) Thermometer

Owner s Manual & Safety Instructions

How To Use A Cdm250 Digital Multimeter

±15 V Current-Limited Power Supply

High Temperature InfraRed Thermometer with Laser Pointer

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

ADM1TE 5/30A DIN rail single phase two wire energy meter

Fluke 1650B Series Multifunction Installation Testers

SOUND LEVEL METER 94405

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Professional Thermohygrometer

Product and functional description

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Transcription:

User Guide 4 wire Earth Resistance Tester Model GRT300

Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according to the IEC Publication 348, safety requirements for Electronic Measuring Apparatus, EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5 and other safety standards. Proper use and care of this meter will provide many years of reliable service. Safety Notes Read the all safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired. Rated environmental conditions : Indoor & outdoor use. Installation Category IV 300V. Pollution Degree 2. Altitude up to 2000m. Relative Humidity 80% max. Ambient temperature 0-40 C. Observe the International Electrical Symbols listed below : Detector is protected throughout by double insulation or reinforced insulation. Warning! Risk of electric shock. Caution! Refer to this manual before using the detector. Earth(ground) terminal. Equipment complies with current EU directives. WARNING To avoid electrical shock, do not touch the terminals during tests Never apply Voltage higher than 300V across P1 and P2 terminals. 2

Features Microprocessor controlled with advanced safety features Two line LCD display Auto-Ranging Earth resistance testing with four ranges: 0-2Ω/0-20Ω/0-200Ω/0-2kΩ Earth voltage measuring range of 0-300Vac Automatic C spike check. Automatic P spike check. 2-wire test 3-wire test 4-wire test Auto power off Data hold Safety standard: EN 61010-1 CATIV 300V, EN 61326-1 Meter Description 1. C1 terminal (Black test lead connection) 2. P1 terminal (Green test lead connection) 3. P2 terminal (Yellow test lead connection) 4. C2 terminal (Red test lead connection) 5 Display 6. Rc LED 7. Rp LED 8. 2 Wire button 9. 3 Wire button 10. 4 Wire button 11. ACV button 12. Power button 13. TEST/STOP button 4 3 2 1 8 9 10 11 12 13 5 6 7 3

Operation Battery Voltage check 1. Press the "ON/OFF" button, if "Battery Low" appears on the display, replace the batteries. Earth Voltage measurement 1. Connect the test leads as shown below. E ES MAX. AC 300V S H C 1 P 1 P 2 C 2 1 2 (1) Earth electrode (rod) under test (2) Test spike 2. Press the "ON/OFF" button and wait for Select Function to appear on the display. 3. Press the "ACV" button and then the "TEST/STOP" button. 4. The earth voltage will be displayed on the display. Note: When the earth voltage is more than 10V, errors in earth resistance measurements may occur. Make sure that the indicated value is less than 10V. 4

Earth Resistance measurement Note: The measured results may be influenced by inductive or capacitive coupling if the test leads are twisted or adjacent to each other. When connecting the Probes, keep the leads separated. Setup Insert the Potential spike and the Current spike (if required) as deep as possible into the soil. The distance between spikes must be 5 to 10 meters (16 to 32 feet). Four-terminal earth resistance measurements E ES S H MAX. AC 300V C 1 P 1 P 2 C 2 1 2 3 (1) Earth electrode (rod) under test (2) Potential spike (3) Current spike Three-terminal earth resistance measurements E ES S H MAX. AC 300V C 1 P 1 P 2 C 2 1 2 3 (1) Earth electrode (rod) under test (2) Potential spike (3) Current spike Two-terminal earth resistance measurements E ES S H MAX. AC 300V C 1 P 1 P 2 C 2 1 2 (1) Earth electrode (rod) under test (2) Potential spike 5

Testing 1. Connect the test leads for 2, 3 or 4 terminal testing. 2. Press the ON/OFF button and wait for the Select Function screen to appear. 3. Press the "2P", "3P" or "4P" button that agrees with the setup. 4. Press "TEST/STOP" button to begin the test. 5. The meter will beep while the test is in progress (approximately 10 seconds) and then the reading will appear on the lower line of the display. Notes: "Rc" & "Rp" LED indications: Rc: No test current output. Check connections. Rp: If Rp is on and the display indicates > 2 kω, the earth resistance is greater than 2000Ω. If, in "4P" mode, the display shows "Vp Error", short circuit C1(black) and P1(green). Measurement Considerations 2 terminal testing of earth resistance is appropriate for most general purpose testing in normally conductive soil. But, 2 terminal measurements include test lead and contact resistance in the measurement and the result will be a reading slightly higher than the true earth resistance. When measured results are higher than desired or if measurement directives require multi-terminal techniques, switch to the 3 or 4 terminal techniques as needed. 6

Maintenance 1. Rear cover 2. Battery 3. Fuse 1 2 3 Fuse Replacement 1. Disconnect the test leads from the instrument. 2. Remove the rear cover by removing two screws. 3. Remove and replace the fuse with the new one of the same value and size 0.1A/250V, 5 x 20mm. 4. Replace and secure the rear cover. Battery replacement When "Battery Low" appears on the display, replace the batteries. 1. Disconnect the test leads from the instrument and remove the rear cover and the batteries. 2. The tester's battery is situated under the tester. 3. Replace with eight 1.5V AA light batteries, taking care to observe correct polarity. 4. Reinstall battery holder and the battery cover. Cleaning And Storage WARNING: To avoid electrical shock or damage to the meter, do not get water inside the case. Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents. 7

Specifications Measuring Ranges Earth Resistance: 0-2Ω, 0-20Ω, 0-200Ω, 0-2kΩ Earth Voltage: 0-300V AC (40 to 500Hz) Accuracy Earth Resistance: ±(2%rdg+3dgt) Earth Voltage: ±(2%rdg+3dgt) Earth Resistance Resolution 0-2Ω : 0.01Ω 0-20Ω : 0.1Ω 0-200Ω : 1Ω 0-2kΩ : 0.01kΩ Test Frequency 820Hz Test Current 2mA Temperature & Humidity Operating : 0 to 50 C (32 to 122 F) 80%R.H. Storage : -10 to 60 C (14 to 140 F) 80%R.H. Power Source 1.5V(AA) x 8 Dimensions 250(L) x 190(W) x 110(D)mm (9.84x7.5x4.33 ) Weight Approx. 1430g(battery included) Fuse( 0.1A/250V 5 x 20mm Copyright 2011 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com 8