1 Engineering for all HMI-Systems Engineering Edition WinCC Professional 512, 4k, max. PowerTags WinCC Advanced WinCC Comfort WinCC Basic Basic Panels Comfort Panels, Mobile Panels Panel PC, Standard PC Panel Page 1 2012-10-29 Visualization with WinCC V12 Single Station based on WinCC flexible RT System based on WinCC V7 Runtime Supported hardware WinCC Professional WinCC Advanced WinCC Comfort WinCC Basic SIMATIC HMI Basic Panels KP300 Basic KP400 Basic New KTP 400 Basic, KTP 600 Basic, KTP 1000 Basic, TP 1500 Basic SIMATIC HMI Panels / Multi Panels OP73, OP77, TP177, OP177, TP277, OP277, MP177, MP277, MP377 SIMATIC HMI Mobile Panels Mobile Panel 177, Mobile Panel 277 Mobile Panel 277 IWLAN V2 SIMATIC HMI Comfort Panels KTP 400 Comfort, KP 400 Comfort, TP 700 Comfort, KP 700 Comfort, TP 900 Comfort, KP 900 Comfort TP 1200 Comfort, KP1200 Comfort TP 1500 Comfort, KP1500 Comfort New TP 1900 Comfort, TP2200 Comfort Page 2 2012-10-29 Visualization with WinCC V12
2 Supported hardware WinCC Professional WinCC Advanced SIMATIC WinCC Runtime Advanced (PC-based single station) with 128, 512, 2k, 4k PowerTags IPC227D, IPC277D IPC427C/D, IPC477C/D IPC577C IPC627C, IPC827C IPC677C IPC647C, IPC847C IPC547D Standard PC Page 3 2012-10-29 Visualization with WinCC V12 SIMATIC WinCC Runtime Professional (PC-based ) with 128, 512, 2k, 4k, 8k, 64k PowerTags IPC427C/D, IPC477C/D (Client) IPC577C (Client) IPC627C, IPC827C IPC677C IPC647C, IPC847C IPC547C/D Standard PC Comfort Panels New New New 4''W 7''W 9''W 12''W 15''W 19''W 22''W Display size 4,3'' 7,0'' 9,0'' 12,1'' 15,4'' 18,5'' 21,5'' Resolution 480x272 800x480 1280x800 1366x768 1920x1080 Prozessor ARM 532 MHz x86 500 MHz x86 1GHz Project memory 4 MB 12 MB 24 MB Tags 1024 2048 4096 Messages 2000 4000 6000 Recipes 100 / 200 / 200 * 300/ 500 / 1000 * 500 / 1000 / 2000 Images 500 500 750 Archives 10 / 10.000 ** 50 / 50.000 ** Scripts 50 100 200 Viewer / multimedia Internet Explorer, PDF, Word- and Excelviewer, Multimedia Player Sm@rtServer yes *) recipes / data sets per recipe / entries per data set **) Archive / entries per archive Page 4 2012-10-29 Visualization with WinCC V12
3 Industrial Thin Client SIMATIC ITC New SIMATIC ITC ITC1200 ITC1500 ITC1900 ITC2200 12" Touch Widescreen Page 5 2012-10-29 Visualization with WinCC V12 15" Touch Widescreen 19 Touch Widescreen 22" Touch Widescreen Resolution 1280 x 800 1280 x 800 1366x768 1920 x 1080 Display CPU Interfaces Webbrowser Protocols high resolution, 16 Mio. colors, 100% dimmable Intel Celeron 1,2 GHz 1 x GBit LAN, 2 x USB 2.0 (backside) HTML5, XML, CSS, JavaScript Sm@rtServer, RDP, VNC Active connections 5 Power supply Certificates 24V DC CE, culus, C-Tick, ATEX Zone 2/22 (planned) Produkt link: 60521782 FAQ: 63258317 Produktvideo 1 Compatibility mode TIA Portal V12 support for the Service use case Exception: Compile of Runtime Professional V11 WinCC ES V11 SP2 RT V11 SP2 V11 Proj. WinCC ES V12 (compatibility mode) RT V11 SP2 Upgrade V12 Proj. WinCC ES V12 RT V11 SP2 RT V12 RT V11 SP2 RT V12 Panel / 1 Panel / 2 Page 6 2012-10-29 Visualization with WinCC V12
4 1 Compatibility mode Work on V11 projects with V12 V11 project can be modified with different versions of the engineering system Saved projects can be opened with TIA Portal V11 SP2 again Functionality and features of TIA Portal V11 SP2 products are supported Engineering system WinCC V11 SP2 Engineering system WinCC V12 (V11 compatibility mode) *Compile and download not supported for Runtime Professional V11 V11 Proj. Open project supported Edit/compile/download devices supported* Page 7 2012-10-29 Visualization with WinCC V12 2 Upgrade to V12 Use of new functionality coming with WinCC V12 Exception: Compile As Runtime Professional V11 WinCC ES V11 SP2 RT V11 SP2 V11 Proj. WinCC ES V12 (compatibility mode) RT V11 SP2 Upgrade V12 Proj. WinCC ES V12 RT V11 SP2 RT V12 RT V11 SP2 RT V12 Panel / 1 Panel / 2 Page 8 2012-10-29 Visualization with WinCC V12
5 2 - Upgrade to V12 Use of new functionality coming with WinCC V12 Use of new functions (e.g. S7-1500) V11 project must be upgraded to V12 Project upgrade includes upgrade of RT Professional Panels and RT Advanced remain in version 11 for service use cases Engineering system WinCC V12 Upgraded V11 project or newly created V12 project can only be opened with TIA Portal V12 products V11 Proj. V12 Proj. Save (V12) project supported Edit/compile/download devices supported Page 9 2012-10-29 Visualization with WinCC V12 2 How to Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named..._v12 No downgrade afterwards, no more use in TIA Portal V11 23 1 Upgrade to V12 Page 10 2012-10-29 Visualization with WinCC V12
6 3 V11 devices in TIA Portal V12 Create, modify and compile V11 devices in V12 project Exception: Compile As Runtime Professional V11 WinCC ES V11 SP2 RT V11 SP2 V11 Proj. WinCC ES V12 (compatibility mode) RT V11 SP2 Upgrade V12 Proj. WinCC ES V12 RT V11 SP2 RT V12 RT V11 RT V12 Panel / 1 Panel / 2 Page 11 2012-10-29 Visualization with WinCC V12 3 V11 devices in TIA Portal V12 No upgrade of Panels FW forced by new version of engineering system WinCC V12 can configure devices with RT versions V11 and V12 Configured RT version decides about supported functionality in editors Version change (V11 V12) is handled similar to Device type change Engineering system WinCC V12 Compile and download not supported for Runtime Professional V11 V12 Proj. V11 device V12 device Page 12 2012-10-29 Visualization with WinCC V12
7 Upgrade process Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named..._v12 No downgrade afterwards, no more use in TIA Portal V11 23 1 Upgrade to V12 Page 13 2012-10-29 Visualization with WinCC V12 V11 devices in TIA Portal V12 No upgrade of Panels FW forced by new version of engineering system WinCC V12 can configure devices with RT versions V11 and V12 Configured RT version decides about supported functionality in editors Version change (V11 V12) is handled similar to Device type change Engineering system WinCC V12 Compile and download not supported for Runtime Professional V11 V12 Proj. V11 device V12 device Page 14 2012-10-29 Visualization with WinCC V12
8 Select RT version Configurable RT version in Add new device dialog Configurable RT version in catalog Page 15 2012-10-29 Visualization with WinCC V12 Configured RT version in Catalog information of configured device (Editor For Devices internal & use networks) only / Siemens AG 2012. All Rights Reserved. Change RT version Change device type / version for selected device Page 16 2012-10-29 Visualization with WinCC V12
9 drivers WinCC Basic offers drivers for: SIMATIC S7-1500 SIMATIC S7-1200 SIMATIC S7-300/400 SIMATIC S7-200 LOGO! New New Allen-Bradley DF1, EtherNet/IP Mitsubishi MC TCP/IP Modicon Modbus TCP/IP No support for SIMATIC S5 Page 17 2012-10-29 Visualization with WinCC V12 drivers WinCC Comfort / Advanced offers drivers for: SIMATIC S7-1500 SIMATIC S7-1200 SIMATIC S7-300/400 SIMATIC S7-200 LOGO! New New Allen-Bradley DF1, EtherNet/IP Mitsubishi FX, MC TCP/IP Modicon Modbus RTU, TCP/IP Omron Host Link driver OPC (DA, XML DA, UA) No support for SIMATIC S5 Page 18 2012-10-29 Visualization with WinCC V12 * SINUMERIK Integrate Create MyHMI / WinCC option has to be installed
10 Process Driver What s new: LOGO! driver for LOGO! interface Ethernet Available in HMI devices Basic PN Panels Mobile Panels 177PN, 277 Multi Panels Comfort Panels Runtime Advanced Data Type and address range Page 19 2012-10-29 Visualization with WinCC V12 drivers WinCC Professional offers drivers for: SIMATIC S7-1500 SIMATIC S7-1200 New SIMATIC S7-300/400 Allen-Bradley EtherNet/IP Mitsubishi MC TCP/IP Modicon Modbus TCP/IP OPC (DA / XML DA) No support for SIMATIC S5 driver Page 20 2012-10-29 Visualization with WinCC V12
11 Diagnostic services STEP 7 HMI WebServer CPU-Display Page 21 2012-10-29 Visualization with WinCC V12 Diagnostic services Display at Panels / RT Advanced System diagnostics viewer Displays the overview of accessible devices and the system state of the plant Switch between device and detail view Same concept at Comfort Panels, RT Advanced, CPU display and CPU webserver There is also a buffer viewer available for Basic Panels Page 22 2012-10-29 Visualization with WinCC V12
12 Diagnostic services Display at Panels / RT Advanced System diagnostics viewer detect errors in plant Click forward through structure to find out the source of an error Autofocus on faulty device Page 23 2012-10-29 Visualization with WinCC V12 New service concept Basic Panels New panel service concept - Basic Panels Runtime project stored on S7-1500 New In the case of a device replacement the HMI backup can be uploaded from the PLC directly into the new panel Usual way HMI Backup Restore HMI PLC Page 24 2012-10-29 Visualization with WinCC V12
13 How to Basic Panels Backup & restore via Basic Panel New item Service & Commission available Select Backup or Restore Scan for an accessible device or insert IP & connect afterwards Create a backup or select & restore an existing one Backup will be placed at or restored from PLCs SIMATIC memory card Page 25 2012-10-29 Visualization with WinCC V12 New service concept Comfort Panels New panel service concept - Comfort Panels Image transfer via USB-Stick or SD-Card (FAT32) Replacement of Comfort Panel without engineering system possible TIA Portal / ProSave is still possible Page 26 2012-10-29 Visualization with WinCC V12
14 How to Comfort Panels Create a HMI OS image Page 27 2012-10-29 Visualization with WinCC V12 How to Comfort Panels Create a HMI OS image Select destination device & create HMI OS image on memory card 1 2 Choose matching display if necessary adapt restore settings It is also possible to download various images on device Page 28 2012-10-29 Visualization with WinCC V12
15 How to Comfort Panels Update OS from SD card or USB stick 1 Page 29 2012-10-29 Visualization with WinCC V12 How to Comfort Panels Update OS from SD card or USB stick 1 2 Page 30 2012-10-29 Visualization with WinCC V12
16 How to Comfort Panels Update OS from SD card or USB stick 1 2 3 Page 31 2012-10-29 Visualization with WinCC V12 How to Comfort Panels Update OS from SD card or USB stick 1 2 3 4 Page 32 2012-10-29 Visualization with WinCC V12
17 Integrated connections Addressing with integrated connections Absolute addressing: connected to address, tag name not necessary searches automatically (reconnect to PLC) for tag name Symbolic addressing: connected to symbolic name, no relation to absolute address supported by S7-1200 and S7-1500 PLCs Page 33 2012-10-29 Visualization with WinCC V12 Integrated connections Addressing PLC tags symbolically Insert tags from standard DBs, optimized DBs or tag tables Page 34 2012-10-29 Visualization with WinCC V12 NO absolute address in this access mode
18 Integrated connections Default settings for addressing PLC tags Change default access method in TIA Portal settings Defines whether PLC tags are automatically addressed absolutely or symbolically Access method can also be changed by hand afterwards Page 35 2012-10-29 Visualization with WinCC V12 Integrated connections Use cases Benefits of symbolic addressing: PLC: changes HMI: not necessary PLC tags: DB (standard or optimized) elements: Change address & Add a row above & PLC PLC Page 36 2012-10-29 Visualization with WinCC V12
19 Integrated connections Use cases Benefits of symbolic addressing: PLC: changes HMI: not necessary Name of PLC tags: Change name & PLC Tag is updated automatically Page 37 2012-10-29 Visualization with WinCC V12 Data types Support of 64-bit data types in HMI with S7-1200 or S7-1500 64-bit tags Higher resolution with usage of LREAL data types Real Floating-point number 32-bit IEEE 754 +-3.402823e+38 LReal Floating-point number 64-bit IEEE 754 +-1.79769313486231e+308 Page 38 2012-10-29 Visualization with WinCC V12
20 PLC tags restrictions Restricted access to PLC tags Visible in HMI: Shows whether the tag is visible by default Accessible from HMI: Shows whether HMI can access this tag even copy & paste does not insert those tags into tag tables PLC tag table HMI tag table: browse PLC tag Page 39 2012-10-29 Visualization with WinCC V12 PLC tags restrictions Restricted access to PLC tags Visible in HMI: Shows whether the tag is visible by default Accessible from HMI: Shows whether HMI can access this tag even copy & paste does not insert those tags into tag tables PLC tag table HMI tag table: browse PLC tag Page 40 2012-10-29 Visualization with WinCC V12
21 PLC tags restrictions Drag & Drop structured PLC tags to HMI Each element is implemented as an individual HMI tag (not structured) HMI tag automatically connected to PLC tag Existing HMI connection is used or a new one will be created Only tags with accessible flag are copied Page 41 2012-10-29 Visualization with WinCC V12 PLC tags restrictions Drag & Drop structured PLC tags to HMI Copy also of complex structures & paste as single tags in HMI tag table Only accessible elements are copied even if the flag is set deep in the structure Page 42 2012-10-29 Visualization with WinCC V12
22 HMI protection levels PLC and HMI protection levels S7-1500 PLC Protection level 4 affects all HMI devices Access granted with password from level 1, 2 or 3 Password defined at the HMI connection Basic Panels, Mobile Panel 277, Multi Panels x77, Comfort Panel, RT Advanced & Professional support access via password Only in this level a password is needed Page 43 2012-10-29 Visualization with WinCC V12 How to PLC and HMI protection levels Password is needed in case of protection level 4 1 Set password to grant access to PLC 2 Page 44 2012-10-29 Visualization with WinCC V12
23 HMI protection levels HMI No password HMI Level 1-3 password HMI No password HMI wrong password RT S7-1500 S7-1500 S7-1500 S7-1500 Level 1-3 Level 4 Level 4 Level 1-4 Page 45 2012-10-29 Visualization with WinCC V12 Object type displayed behind name Adjust zoom New tab New icons Page 46 2012-10-29 Visualization with WinCC V12
24 Languages & multilingual texts Easier handling of multilingual texts Edit texts of screen, whole groups or multi selections Copy and paste of texts All in one window without changing editing language Languages have to be activated in languages & resources Page 47 2012-10-29 Visualization with WinCC V12 Rewiring Change object references similar to rewiring functionality from WinCC flexible Shows tag references within screens Finds tags with properties or events as point of use Page 48 2012-10-29 Visualization with WinCC V12
25 How to Use cases: Same screens for different DBs Library Screen template Screen_1 I/O field Connect tags DB1_status DB1_min DB1 DB2 DB1_max Configuration Screen_1 DB1_status DB1_min DB1_max Copy screen Screen_2 DB1_status DB1_min DB1_max rewire Change object reference Find & replace string DB1 by DB2 rewire Screen_2 DB2_status DB2_min DB2_max Page 49 2012-10-29 Visualization with WinCC V12 How to Change object references Precondition: well organized tags Open from context menu Find and replace parts of tag names 2 3 1 4 Page 50 2012-10-29 Visualization with WinCC V12
26 Reconnect PLC tags Reconnect PLC tags similar to WinCC flexible based on: Symbolic addresses Absolute addresses Page 51 2012-10-29 Visualization with WinCC V12 Reconnect PLC tags Reconnect if the path / tag name matches The connection is marked red because PLC connection changed Reconnect checks validation in new connection path PLC connection changed & address changed Reconnect checks validation in new connection path & updates the address The path of the PLC tag matches The connection has to be already created Page 52 2012-10-29 Visualization with WinCC V12
27 Reconnect PLC tags Reconnect if the address matches The field PLC tag is empty because... tags have been imported a copied tag table from library Reconnect finds matching tag names The connection is marked red because PLC connection changed Reconnect checks validation in new connection path The address of the PLC tag matches The connection has to be already created Page 53 2012-10-29 Visualization with WinCC V12 Runtime file browser Runtime file browser Useful to transfer a file s path to a tag by selecting the file in the browser The tag can be used to open webpages, PDFs, etc. Available for Comfort Panels and Runtime Advanced Page 54 2012-10-29 Visualization with WinCC V12
28 How to Configuration Use new system function OpenFileBrowser, e.g. click event at a button Use Initial directory for browsing location Select a tag (Wstring) to configure the output path: Path (Out) Page 55 2012-10-29 Visualization with WinCC V12 Offline download Download to device New: Download single stations to a local path or an external device Usual way: Download to network path Engineering Station WinCC Client RT Page 56 2012-10-29 Visualization with WinCC V12
29 Run as service WinCC as service: WinCC servers as service, Clients interactively WinCC server is located in a separate room, no user needs to be logged in WinCC Runtime starts automatically with Windows Monitoring and control of the WinCC project from the clients / Web clients Dedicated Web Navigator or Data Monitor server as service separated room Page 57 2012-10-29 Visualization with WinCC V12 How to Configuration Open WinCC RT Start Select a project Switch to tab Operation mode Insert Windows user and password Activate service Page 58 2012-10-29 Visualization with WinCC V12
30 Vertical fonts Vertical fonts Define a font in vertical reading direction @ in front of the name signals a vertical font Set text orientation vertical 1 2 Page 59 2012-10-29 Visualization with WinCC V12 Engineer working together Slides will be available for S7-300, S7-1200 & S7-1500 Slides are currently in work Published as newsletter (HMI- and TIA- Promotors) Published as FAQ Page 60 2012-10-29 Visualization with WinCC V12
31 Comfort Panel migration Integrated Classic project available Switch to STEP 7 and WinCC V11 New project Use of STEP 7 and WinCC V11 WinCC flexible STEP 7 classic WinCC (TIA Portal) STEP 7 (TIA Portal) Migration of project Device change Use of TIA Portal Benefits WinCC (TIA Portal) STEP 7 (TIA Portal) Use of TIA Portal Benefits Integrated Classic project available Switch to WinCC V11 New project Use of STEP 7 classic and WinCC V11 WinCC flexible STEP 7 classic WinCC (TIA Portal) STEP 7 classic Deintegration Migration of WinCC flexible Device change WinCC (TIA Portal) STEP 7 classic Export of STEP 7 Tags Convert tags with TagConverter Import in WinCC V11 Page 61 2012-10-29 Visualization with WinCC V12 Working with STEP 7 classic & WinCC V12 together WinCC (TIA Portal) and STEP 7 classic Existing STEP 7 with new WinCC (TIA Portal) project 1. Create the HMI in WinCC (TIA Portal) 2. Export the needed tags from STEP 7 3. Convert the export file with WinCC Tag Converter (Link) 4. Import the converted file in WinCC (TIA Portal) All tags are converted with absolute address Changes on some single tags in STEP 7 project can be updated manually big changes can be updated with the help of Tag Converter No support of reporting system errors (RSE) & controller alarms Page 62 2012-10-29 Visualization with WinCC V12
32 WinCC Tag Converter How to Export of tags from STEP 7 classic Single data blocks Open the data block File Print Generic / Text only printer Input path \ filename.txt in the following dialog Page 63 2012-10-29 Visualization with WinCC V12 WinCC Tag Converter How to Export of tags from STEP 7 classic Single or several data blocks Generic / Text only printer is the windows standard printer Right mouse on the needed data blocks Print Object Content Input path \ filename.txt in the following dialog for each DB Page 64 2012-10-29 Visualization with WinCC V12
33 WinCC Tag Converter How to Export of tags from STEP 7 classic Symbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog Page 65 2012-10-29 Visualization with WinCC V12 WinCC Tag Converter How to Export of tags from STEP 7 classic Symbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog Page 66 2012-10-29 Visualization with WinCC V12
34 WinCC Tag Converter How to Conversion of tags with WinCC Tag Converter Converts the tag export files of SIMATIC Manager, Rockwell (Allen-Bradley) and Schneider/Modicon in the import-format of WinCC (TIA Portal) WinCC Tag Converter export file from PLC programming Tool converted file ready to import in WinCC Page 67 2012-10-29 Visualization with WinCC V12 Industry Online Support: Deutsch English WinCC Tag Converter How to Import of tags to WinCC (TIA Portal) The converted file with the tags can easily be imported. Hint: the PLC connection should be created in WinCC previously Converted file: HMI Tags Show all tags: start tag import Page 68 2012-10-29 Visualization with WinCC V12
35 Advanced color picker Not every color is supported by each Panel Therefore TIA Portal adapts colors & displays the current, the selected and the adapted color in a preview Selected color Adapted color, details see tooltip Page 69 2012-10-29 Visualization with WinCC V12 Cross references Number of locations where the object is used 2 1 Page 70 2012-10-29 Visualization with WinCC V12
36 Move object to the next snap line Use s + arrow key to move object Page 71 2012-10-29 Visualization with WinCC V12 New system function in Set language directly or toggle Page 72 2012-10-29 Visualization with WinCC V12
37 Events with improved look and feel V11 V12 Page 73 2012-10-29 Visualization with WinCC V12 Two new expression templates Expressions AND & OR added Additional space for expressions Enough space for long expression Page 74 2012-10-29 Visualization with WinCC V12
38 Animate property: Support of floating points (range type) Including new elements: Brackets & intervals Bracket Example If the process value (x) is than color is [ - ] [0-0.25] 0 x 0.25 black ] - ] ]0.25-0.5] 0.25 < x 0.50 red ] - [ ]0.5-1[ 0.5 < x < 1 yellow Page 75 2012-10-29 Visualization with WinCC V12 Support of floating points Use case expression: calculations Overlapping areas are invalid and marked red RT V12 Page 76 2012-10-29 Visualization with WinCC V12
39 Screen window Improved handling Select Open screen to switch to displayed screen Page 77 2012-10-29 Visualization with WinCC V12 Faceplates Blue bold colored text indicates the usage of a property Page 78 2012-10-29 Visualization with WinCC V12
40 Feature Panels RT Advanced RT Professional news - - - S7-1500 driver Symbolic addressing 64-bit data types Restricted access to PLC tags Protection levels New tab for multilingual languages Change object reference (rewire) Reconnect tags Offline transfer - - Run as service - - Page 79 2012-10-29 Visualization with WinCC V12 Feature Panels RT Advanced RT Professional System diagnostic viewer - Backup & restore an image at PLC only Basic - - OS Update via external devices only Comfort - - Advanced color picker - - Counting in cross references Move object to snap lines via keyboard Advanced context menu for events New expression templates - - Floating points for property animation - - Vertical fonts - - Improved handling of screen windows - - Faceplates: colored texts - - Page 80 2012-10-29 Visualization with WinCC V12