NIAGARA Niagara Blower Heat Transfer Solutions



Similar documents
A Comprehensive Laboratory Test to Analyze the Compatability of Leading Cleaners and Sanitizers on Today's Industrial Refrigeration Evaporator Coils.

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

How To Understand Evaporator

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Thermochemical Storage for Air-Conditioning using Open Cycle Liquid Desiccant Technology

Why is my air conditioner dripping on my customers?

Automobile Air Conditioning Primer

164,491 SF Food Production Facility Situated on 10 Acres Available in

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Chilled Water HVAC Systems

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

CONDENSATION IN REFRIDGERATED BUILDINGS

Innovent LASER Packaged Fresh Air Conditioning Units

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

By Tom Brooke PE, CEM

DEFROSTING. Service Engineers Section Technical Bulletin No 3

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Troubleshooting Your Refrigerator

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA

Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!

The Different Types of Air Conditioning Equipment for IT Environments

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

solarplus solar systems general features

Contents and Nomenclature

Dehumidification Frequently Asked Questions

SECTION MORTUARY REFRIGERATORS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Glossary of Heating, Ventilation and Air Conditioning Terms

Sondex Welded heat exchangers:

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Local Dealer:

Defining Quality. Building Comfort. Heating and Cooling Coils

Answers to Your Questions from the Webinar

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

DECISION-MAKING TREE FOR DISASTER RECOVERY SOLINET Preservation Services

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

FLASH TANK ECONOMIZER PRODUCT GUIDE

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

Failure code manual. content

Evaporative Cooling. Terminology. Date: February 28, Concepts

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Mechanical Rooftop Custom Capabilities

MAC-120HE-01 Air-Cooled Chiller

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

Frost. On Air-Cooling Evaporators. refrigeration applications at temperatures below freezing. These heat exchangers


engineering quality Heat Transfer Specialists Since 1928 service delivery

Pool Dehumidification Basics

Calculating System Flow Requirements

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Air Conditioner Maintenance

ThermoSorb Desiccant Dryers

ASME Packaged Indirect Fired Water Heater

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

SWIMMING POOL HEAT PUMP

How does solar air conditioning work?

Slim Contour Unit Cooler

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

AIR CONDITIONING TECHNOLOGY

How Ground/Water Source Heat Pumps Work

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

How air conditioning works

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

AustCold INDUSTRIAL REFRIGERATION AND GAS COMPRESSION PLANT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Why Daikin? 2015 Houston, Texas USA

Nordic Heat Pump Product Guide

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

The HVAC Process: Changing the Properties of Air

The information provided below is intended for emergency recovery and response, not general treatment recommendations.

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

New Trends in the Field of Automobile Air Conditioning

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

Lesson 36 Selection Of Air Conditioning Systems

REFRIGERATED COMPRESSED AIR DRYERS

Solar Desiccant Air Conditioner

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

Transcription:

NIAGARA Niagara Blower Heat Transfer Solutions No-Frost No-Frost refrigeration and liquid desiccant dehumidification specializes in the food, beverage, laboratory testing, and cold storage industries. www.niagarablower.com

Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil

Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil

Industries Served General Specifications What is No-Frost? Desiccant concentration determines moisture removal capacity. Three different No-Frost liquid formulas are available: LV 50 through 40 F Ethylene glycol based Low viscosity No-Frost refrigeration applications KV 5 through 55 F -grade Propylene glycol based No-Frost refrigeration and dehumidification applications No-Frost technology is ideal for processing, packaging, and storage applications where consistent, frost free conditions are required. Hygrol 30 through 75 F Water treatment plant Triethylene glycol based Dehumidification applications No-Frost systems are comprised of sprayed coil or structured packing conditioner(s) and liquid concentrator(s). Laboratories Baking Dairy Meat & Poultry Distillation Column Concentrator (DCC) All units are custom fabricated to withstand the toughest environments Applications Freezers Frozen Glycol based refrigeration defrost Glycol based liquid desiccant dehumidification Maintains a sanitary, frost-free coil Permanently inhibits 99.9% of airborne pathogens Liquid desiccant absorbs moisture from air stream Heavy duty bolted construction Casing panel options: carbon steel, stainless steel, or fiberglass ASME/ANSI code design Interior parts readily accessible for inspection and cleaning Packaged and field-erected units available Spiral freezer Control panel Niagara can provide: Meat processing Field surveys Engineering design New components Retrofit manufacturing Piping layouts Wiring diagrams Contractor management Complete controls Piping & instrumentation diagrams Commissioning Finned cooling coil Refrigerant flows through finned evaporator coil tubes Desiccant mixture drenches tubes Air is induced over sprayed evaporator coil

Rooftop installation No-Frost Advantages Consistent temperature Consistent dew point Low energy usage Low operating & maintenance costs Asset protection Noncorrosive desiccant liquid Eliminates mold and bacteria Quick recovery from wash down Ensures uninterrupted production Air stream is sanitized/deodorized No-Frost desiccant spray arrangement

How Does No-Frost Work? Niagara local representative: About Niagara Blower Heat Transfer Solutions Headquartered in Buffalo, NY, Niagara has proudly provided engineered solutions for heat transfer applications at process, power, refining, and food & beverage facilities worldwide since 1904. Niagara boasts a fully equipped laboratory, test facility, ASME code certified factory, custom manufacturing capabilities, and over 100 years of proven success. Niagara product lines include Wet Surface Air Coolers, "No-Frost" refrigeration/dehumidification systems, and Kathabar salt based dehumidification systems. NIAGARA Niagara Blower Heat Transfer Solutions 673 Ontario St., Buffalo, NY 14207 Phone: (716) 875-2000 ~ Fax: (716) 875-1077 sales@niagarablower.com / www.niagarablower.com