Digester Gas Safety Equipment



Similar documents
Tank Level Gauging, Safety Equipment & Inventory Management for Alcohol and Beverage Applications

Morrison Bros. Co. General Product Specifications

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Semi-Instantaneous Water Heaters

Commercial Gas Water Heaters

Commercial Gas Water Heater

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

LANDFILL GAS ENCLOSED FLARE SYSTEM

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

2010 Residential Water Heater Replacement Check List

Gas-Fired, Residential Storage Type Water Heaters

Electronic Flow Switches

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

NAVIEN AMERICA INC FITCH AVENUE

BERMAD Fire Protection

CARING FOR YOUR WATER HEATER

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Your safety and the safety of others are very important.

Boiler Preparation, Start-Up and Shutdown

Float and Thermostatic Traps Series H, C and X

Munchkin Heat Exchanger Maintenance

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

BERMAD Fire Protection

Some Criteria for Choosing a Steam Boiler for a Microbrewery

AUTOMATIC CHANGEOVER MANIFOLD Series 915

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Medical Air Systems: Scroll

REGULATORS 175/153 Series

Sanitary Type Electronic Flow Switches

In-Line Electronic Flow Switches

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Originators of the Flexible Water Tube design

VOYAGER 570G. 744A Sprayer Control

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Commercial Electric Water Heater

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

KNC Model 3666 Automatic Pressure Calibration System

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

COMBIMASS. Technical Data COMBIMASS eco-bio +

Air Conditioner Water Heater Model ACWH18

Heating Water by Direct Steam Injection

Commercial & Industrial Propane Regulators and Meters

Arapahoe County Residential Water Heater Installation and Inspection Guide

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Fire Pump Plan Review March 2010

WHOLESALE DIRECT INC WEST 65TH STREET

ASME Packaged Indirect Fired Water Heater

High efficiency, cast-iron gas boiler

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Element D Services Plumbing

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

IGEMA BOILER LEVEL & TDS CONTROLS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Model DE-3 Air Release Head

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Indirect-fired Steam & Boiler Water Heaters

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Electric & Gas Water Heaters

Mechanical Seal Piping Plans

Used Fluid Handling Portable Used-Oil Gravity Drains

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

The Concept of Condensing Boilers

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Pressure and Temperature Controls

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Fundamentals of Mass Flow Control

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Commercial Gas Water Heaters

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Energy Efficient Operations and Maintenance Strategies for Boilers

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

Transcription:

Digester Gas Safety Equipment Waste Gas Burners/Flares Anaerobic Digester Cover Equipment Digester Gas Stream Equipment Serving Municipal Sewage Treatment Plants, Landfills, Breweries, Dairies and Food-Processing Plants an L&J Technologies company 1

Typical Digester Cover Equipment System A B C D E A. 94020 Pressure & Vacuum Conservation Vent with 94306/94309 Flame Arrester and 97190 3-Way Safety Selector Valve B. 95021 Gauge Hatch C. 94225 Emergency Vent & Manhole Cover (Pressure & Vacuum) D. 95220 Clamping Manhole Cover E. 97187 View Port Inspection Cover F. 92021/ 92500 Cover Position Indicator with MCG 2000MAX Transmitter F This diagram is for general guidance only and does not represent a specific design. Digester Cover Equipment S&J 94020 Pressure/Vacuum Relief Vent Open or Closed Options Available Pallet Reaction Lip for Smooth Lift & Reseating Vertical Lift Pallets Assure Reliable Operation and Maximum Flow Innovative Expanda-Seal Optional: CE & ATEX Approved, All Weather, Proximity Switch S&J 94306/94406* Vertical Flame Arrester Serves as a Barrier Between External Flame and Internal Vapors Protects Digesters Containing Flammable Gases Easy Inspection and Maintenance due to Simple Removal of Tube Bank FM Approved * ATEX Approved S&J 97190 3-Way Safety Selector Valve Sizes 2, 3, 4, 6, 8 and 10 Permits Switchover Function High Flow Capacity with Minimal Pressure Drop Positive Shutoff of Isolated Branch Low Torque Operation During Switchover Provided with Red Position Indicator and Lockout Position S&J 94309 Flame Arrester (Plate Element) Easy to Access Element/Frame Inspect in Place Vertical or Horizontal Configuration FM Approval Available S&J 94307/94407* Horizontal Flame Arrester Inhibits Flame Propagation in Gas Piping Systems Protects Digesters Containing Flammable Gases Offset Design Prevents Condensate from Accumulating Easy Inspection & Maintenance due to Simple Removal of Tube Bank Optional: Sensor Ports * ATEX Approved S&J 97570/97571 Combination Conservation Vent and Flame Arrester Serves as a Barrier Between External Flame and Internal Gases Provides Protection Against Flame Propagation Open or Closed Vent Configurations Available with 94309 Flame Arrester (97571) 2

Digester Cover Equipment S&J 92021/92500 Cover Position Indicator Standard Aluminum Materials, Other Materials Available Gauges for Floating or Spirally Guided Covers Optional: Switches for Alarm and Transmitter for Remote Monitoring S&J 94210 Emergency Vent & Manhole Cover 10, 16, 20, 24, 30 & 36 Base Materials of Construction Include Aluminum, Steel & 316SS Designed for Emergency Pressure Relief Designed to Fit ANSI/API Flange (Other Flanges Available) Easy Installation and Handling for Inspection Optional: Limit Switches S&J 95021 Gauge Hatch Sizes 4, 6, 8, 10 and 12 Standard Aluminum, Steel, 316SS and Bronze Easy Access Teflon Diaphragm Ensures Safe Tight Seal Quik-Clamp Option Allows for Hands-Free Operation S&J 95220 Clamping Manhole Cover 42, 48, 54 and 60 ANSI Sizes Easy Access to Digester for Maintenance and Inspection Lightweight Dome Gas-Tight and Watertight Seal Self-Locking Pedal Maximum Working Pressure of 1 PSIG Materials of Construction Include Aluminum, Base & Cover with Brass, Bronze or Stainless Steel Clamps Optional: API, DIN and Other Connection Types UL/ULC Listed, ATEX Approved MCG 2000MAX Transmitter Magnetic Absolute Xmitter Digital or 4-20 ma Output Couples to Most Mechanical Gauges Easy Maintenance & Calibration Lightning and Surge Protection Not Affected by Power Loss Optional: Wireless S&J 94225 Emergency Pressure & Vacuum Vent/Manhole Cover Sizes 16, 18, 20, 24 ANSI/API Materials of Construction Include Aluminum, Steel and 316SS Design Incorporates Pressure and Adjustable Vacuum Relief Hinged Cover Provides Precise Sealing and Safety No Unbolting of Vent for Seal Replacement or Tank Examination S&J 95210 Clamping Manhole Cover Sizes 12, 16, 18, 20, 24, 30, 36 & 48 ANSI/API/MSS Materials of Construction Include Aluminum, Steel and 316SS Steel, Stainless Steel, Brass or Bronze Clamps Easy Access to Tanks for Maintenance and Inspection Threaded Clamping Handle Provides Gas-Tight & Watertight Seal S&J 97187 View Port Inspection Cover Sizes 8, 10, 12, 16, 20 & 24 ANSI, API, Puddle Flange Connection Easy Viewing of Vessel Contents Gas Tight Light Weight, Hinged Cover for Glass Protection Stainless Steel, Aluminum, or Carbon Steel Construction Maximum Working Pressure 1 PSIG Optional: Illumination and Sprayer Expanda-Seal To reduce emissions, Shand & Jurs designed and patented a high performance valve sealing technology called Expanda- Seal, which has reduced emissions and odors in every process environment imaginable. Expanda-Seal ensures less than 0.5 SCFH air at 95% of the set point. This innovative design actually uses the internal vessel pressure to create a tighter seal the closer the pressure gets to the set point. The end result is a tight seal that greatly helps reduce emissions. Pressure Below Set Point Approaching Set Point Set Point Exceeded 3

Digester Gas Stream Equipment Typical Digester to Boiler Gas System A. 97180 Foam Separator B. 97120 Sediment Trap C. 97100 Manual Drip Trap D. 97400 Well-Type Manometer E. 97127 Gas Purifier F. 97177 Double Port Pressure Regulator or 97150 G. 97220 Check Valve H. 97140 Flame Trap Assembly I. 97100E Electric Actuated Drip Trap J. 94160 Emergency Relief Vent Flow D Digester A B E C J Mounted Outside H G F I Flow Boiler This diagram is for general guidance only and does not represent a specific design. Digester Gas Stream Equipment S&J 97120 Sediment Trap Inlet Sizes 2, 3, 4, 6, 8, 10, 12, 14 & 16 Steel and Stainless Steel Materials Removes Sediment and Condensate Large Capacity Easy Cleanout Low Pressure Drop Design Optional: Sight Glass & Cooling Coil S&J 97125 Condensate Accumulator 13 or 125 Gallon Capacities Efficiently Stores and Evacuates Condensate Through Internal Drip Leg Large Storage Capacity Optional: Alarm Switches, Sight Glass and Solenoid S&J 97127 Gas Purifier Efficient Removal of H 2 S Designed for Low Pressure Biogas Applications Handles Finite Range of Operating Conditions 8 and 12 Diameters Fiberglass Tank Provides Optimum Corrosion Protection Manual or Continuous Regeneration Configuration (97140 shown) S&J 97140/97141 Flame Trap Assembly Aluminum and 316SS Positive Emergency Shutoff Inhibits Flame Propagation 255 F Fusible Link Horizontal or Vertical Mounting Optional: Proximity Switch Combines 97130 Thermal Valve w/ 94307, 94407 or 94309 Flame Arrester 4

Digester Gas Stream Equipment S&J 97177 Double Port Pressure Regulator Sizes 2, 3, 4, 6 & 8 Upstream or Downstream Control Balanced Double Port/Plug Design Large Diaphragm for Increased Sensitivity Externally Adjustable Set Point with Visual Indicator Fewer Moving Parts for Longer Service Life No External Power Source Required S&J 97220 Back Pressure Check Valve Eliminates Reverse Flow Replaceable Pallet/Seat Maximum Flow with Minimum Pressure Drop Flanged or Threaded Connections S&J 97180 Foam Separator Continuous Wash Spray System Removes Foam and Particles Large Reservoir with Baffle Steel, 304 SS, 316/316L SS Construction Optional: Visual Drain Flow Indicator, Water Solenoid Valves, and Alarms for High and Low Water Level S&J 97400 Well-Type Manometer Sizes 12, 20, 24 or 30 Aluminum or SS Materials Pressure or Vacuum Measurement Measures Differential or Point Pressure Readings Indoor or Outdoor Use Easily Bank Mounted Optional: Float Check Valve, Vented Petcock and Isolation Valve Optional Mounting Panel Digester Gas Stream Equipment - Drip Traps & Panels S&J 97100 - Manual Drip Trap Positive Gas Shut-off While Draining Operated Manually 5 PSI or 25 PSI 3 or 6 Quart Capacities Internal Parts and Hardware Stainless Steel - Standard Optional: Air Inlet and Insulation Jackets S&J 97100E - Electric Actuated Drip Trap Positive Gas Shut-off While Draining Automatic Operation with an Electronic Timer 5 PSI or 25 PSI 3 or 6 Quart Capacities Optional: Air Inlet, Insulation Jackets and Local Control Panel S&J 97101 - High Pressure Manual Drip Trap Positive Gas Shut-off While Draining 100 PSIG Standard 4 Quart or 6 Quart Capacity Locking Lever Double Seal Ball Plug Valves Carbon Steel or Stainless Steel Construction S&J 97110 - Automatic Drip Trap Positive Gas Shut-off While Draining Automatic Unattended Removal of Condensate 5 PSI or 25 PSI 2 Quart or 4 Quart Capacity Float Operated Inlet Size 1 5

Digester Gas Stream Equipment - Drip Traps & Panels Cont. S&J 97101E - Electric Actuated Drip Trap Carbon Steel or Stainless Steel Construction 4 Quart or 6 Quart Capacity Positive Gas Shut-Off While Draining Double-Seal Ball Plug Valves 100 PSIG Standard Programmable Timer (Internal or in LCP) Optional Local Control Panel (LCP): NEMA 4X Fiberglass, NEMA 4X 304/316 Stainless Steel, or NEMA 7 Aluminum S&J 97100P/97101P - Local Control Panel The 97100P/97101P Local Control Panel can control up to 8-97100E/97101E units maximum. Selectors include Auto/ Local Mode and Local Fill/Drain. Indicators show when the drip trap is filling or draining. Optional fail indicator and status / fail dry contacts. The Local Control Panel is available for manual control only or with automatic timers. Typical enclosures are Nema 4X Fiberglass, 304 Stainless Steel, 316 Stainless Steel or Nema 7 Aluminum. Insulation Jackets Shand & Jurs insulation jackets provide heat retention for equipment in cold weather environments. Construction of the insulating jacket is silicone impregnated woven glass cloth lining with 1 thick fiber glass material. The jacket is easy to install and remove in the field. Insulation jackets are available for most equipment. S&J 94020 Pressure & Vacuum Relief Valve (Open) S&J 94309 Flame Arrester (Plate Element) S&J 97161 Pressure Relief and Flame Trap Assembly S&J 97571 Combination Pipe-Away Conservation Vent and Flame Arrester with 97190 3-Way Safety Selector Valve Waste Gas Flares & Burners - Accessories Typical Waste Gas Burner Diagram G This diagram is for general guidance only and does not represent a specific design. H A. 97400 Well-Type Manometer B. 97160 Pressure Relief and Flame Trap Assembly C. 97100E Electric Actuated Drip Trap D. 94160 Explosion (Pressure) Relief Vent E. 97100 Manual Drip Trap F. 97200 Flame Check G. 97301 Waste Gas Burner H. 97301 Control Panel with Ground Level Pilot A B D F C E 6

Waste Gas Flares & Burners - Accessories (97161 shown) S&J 97150 Single Port Regulator Internal/External Sense Tap Large Diaphragm Operated/Spring Loaded for Sensitivity Maintain Upstream Pressure Simplified Cleaning and Maintenance Optional: 3-Way Solenoid S&J 97160/97161 Pressure Relief/Flame Trap Assembly Internal/External Sense Tap Positive Emergency Shut-off Maintain Upstream Pressure 255 F Fusible Link Optional: 3-Way Solenoid Combines 97150 Pressure Regulator with 94307/94407 or 94309 Flame Arrester S&J 97300 Waste Gas Burner High Performance Stoichiometric Pilot No Flame Front Burn-out of Pilot Gas During Ignition Burns High Flow, Low BTU Wet Methane No Venturi Maintenance State-of-the-Art Digital Control Fully Automated Continuous or Intermittent Pilot Provides Alarm Outputs S&J 97310 Enclosed Waste Gas Burner No Visible Flame Controlled Combustion Environment with Natural Draft Design High Destruction Removal Efficiency High Turn Down Ratios Convenient Sampling Ports Operates with Low Input Pressures Advanced Automatic Ignition System S&J 97200 Flame Check Sizes ¼, ½, ¾, 1, 1 ½ and 2 Standard Aluminum or Stainless Steel Prevents Flame Flashback in Pilot or Small Gas Lines High Flow Capacity 25 PSIG Working Pressure S&J 94160 Emergency Relief Vent Sizes 2, 3, 4, 6, 8, 10, 12, 16, 20 & 24 Maximum Flow Capacity, Minimum Leakage Reduced Number of Components Minimized Maintenance and Replacement Costs Optional: All-Weather S&J 97301 Waste Gas Burner High Performance Stoichiometric Pilot Burns High Flow, Low BTU Wet Methane Stainless Steel Flame Area Superior Pilot Wind Protection Solid State Controls Fully Automated Continuous or Intermittent Pilot Ground Level Venturi Pilot Ignition Provides Alarm Outputs S&J 97311 Enclosed Waste Gas Burner Sizes 3, 4, 6, 8, 10 & 12 No Visible Flame Controlled Combustion Environment with Natural Draft Design High Destruction Removal Efficiency High Turn Down Ratios Ground Level Inspirating Venturi Pilot/ Ignition Lines Operates with Low Input Pressures Advanced Ground Level Automatic Ignition System S&J 973XXT Series Touch Screen Control Panel Designed with the system operator in mind, the new touch screen control panel offers easy, more precise control. The touch screen control panel is designed for complete automatic operation of the entire Flare System and can monitor the flare s temperature, the pilot, spark, etc. S&J s system gives the operator much more flexibility in controlling the system with more parameters easily configured via the touch screen. The Control Panel can also be connected to a local PLC. Shand & Jurs Biogas latest touch screen control panel option is now available as the 97300T, 97301T, 97310T and 97311T Burners and Flares. 7

L&J Technologies offers a complete line of products that provide solutions for hundreds of Industrial and commercial applications. Visit us online at www.ljtechnologies.com Liquid Level Gauging with Temperature Inventory Management Liquid Level Switches Point/Multi-Point Level Controls & Continuous Level Sensors Tank Vents, Flame and Detonation Arresters, Fittings & FRP Equipment Digester Gas Equipment Waste Gas Burners Mold Level & Strip Guiding Measurement & Control Systems for Metals/Steel Industries Locations World Headquarters 5911 Butterfield Road Hillside, IL 60162 Phone: 708-236-6000 Fax: 708-236-6006 Houston Office Phone: 281-821-0322 Fax: 281-821-1796 Singapore Office Phone: 65-6293-1355 Fax: 65-6293-1357 www.ljtechnologies.com 8