T7079A,B Solid State Remote Temperature Controllers



Similar documents
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Y7230A CO 2 Alarm System

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

T775U Series 2000 Electronic Stand-Alone Controller

T775A,B,C,D Remote Temperature Controller

UV100A Ultraviolet Air Treatment System

T6570, T8570 Series Digital Fan-Coil Thermostats

TR21, TR22, TR23, and TR24 Wall Modules

T7560A,B,C Digital Wall Module

T775A/B/M Series 2000 Electronic Stand-Alone Controllers

Solid State Timers Type F

Radiant Temperature Sensor TY7321

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

System 350 A350E Electronic Cooling Control

HMI display Installation Guide

! WARNING. Before using product, read and understand instructions.

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

A99B Series Temperature Sensors

System 350 A350R Electronic Temperature Reset Control (with Relay)

Series 71, 72, and 76 Modutrol IV Motors

Installation Guide. Programmable Thermostat TH6220D

TC-9102 Series Surface Mount Temperature Controllers

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

, User s Manual

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

T822, TS822 Heating/Cooling Thermostats

Electronic Control Devices The European Product Catalogue 2007

INSTALLATION INSTRUCTIONS

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Sanitary Type Electronic Flow Switches

ACS-30-EU-EMDR-10-MOD

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Electronic Control Devices The European Product Catalogue 2007

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Technical Guide. Thermostats Air Conditioning

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

G670 Intermittent Pilot Ignition Controls

PSR The compact range Description

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Duct Humidity Transmitter

This page is subject to proprietary rights statement on last page

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

LIEBERT VNSA Installation Sheet

How To Use A Power Supply With A Powerline 2.2 (Powerline) And Powerline 3.2 Power Supply (Powerplant)

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Problem / Solution. The problem:

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Electronic Flow Switches

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Fire Pump Controllers Remote Alarm Panels

CompactLogix Power Supplies Specifications

Solid-State Timer H3G

WD-AMX Water Detection Controllers

Series 90 Modutrol IV Motors

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Installation Instructions

Electronic, Digital and Mechanical Vibration Switches

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Heating, air-conditioning, cooling

Single Phase Soft Starter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

T5000 T000 LCD Digital Fan Coil Thermostat

Oil and Coolant Circulating Heating System. Model - OCSM

FX07 Field Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Water Leak Detection System

BACnet Automation Interface Module (Network Version)

Telefon (+45) Telefax (+45) Installation and operating manual

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Toroidal Conductivity Sensor

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

AXIS T81B22 DC 30W Midspan

Operator: Save these instructions for future use!

Transcription:

T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature sensor. Wide setpoint temperature range. LED annunciation for both power on and relay state. Dual setpoint scale ( F and C). Isolation transformer for 24 Vac input. Single- or Dual-stage output. Dual-stage output models can be configured as two-heat, two-cool, or one-heat/one-cool. APPLICATION The T7079 Electronic Remote Sensor Temperature Controller is capable of providing on-off temperature control for ducts, tanks, heating and refrigeration units, greenhouses, animal confinement buildings and other applications where electronic accuracy in addition to remote sensing is desired. Contents Application... Features... Specifications...2 Ordering Information...2 Installation...3 Wiring...4 Operation...5 Checkout...6 Put UPC Code Here 63-2572 04

SPECIFICATIONS Models: T7079: On-off wall-mount control with one temperature input and one or two relay output stages. Differential range of to 30 F. Includes one sensor. See Table. Table. T7079 models. Voltage (in Vac) Setpoint Range in F ( C) -25 to 05 00 to 240 24 20/230 (-32 to 40) (38 to 6) T7079A004 X X T7079A02 X X T7079A046 X X T7079A053 X X T7079B028 X X T7079B036 X X T7079B044 X X T7079B05 X X Dimensions: See Fig.. 2 (50) (25) 2-7/6 (6) 2 (50) 2-7/6 (6) STAGE STAGE2 POWER Power Consumption: See Table 2. Table 2. Power consumption ratings. Voltage Hz Nominal VA Maximum VA 24 50 5.6 6.2 60 5.5 6. 20 50 7.7 8.5 60 5.6 6.2 230 50 5.0 6. 60 2.9 4.7 Contact Ratings: At 20 Vac: /2 hp, 9.8 FLA, 58.8 LRA. At 230 Vac: /4 hp, 4.9 FLA, 29.4 LRA. At 20/230 Vac: 25 VA pilot duty. At 24 Vac (resistive): 8A. Ambient Ratings: Operating Temperature: -40 to 40 F (-40 to 60 C). Storage Temperature: -40 to 80 F (-40 to 82 C). Operating Humidity: 5% to 95% RH non-condensing. Temperature Accuracy (at nominal voltage): In 77 F (25 C) ambient, nominal sensor value: ±2 F. Accuracy can vary based on deviation from nominal values of input voltage, operating ambient and sensor ambient. Sensor: 0k NTC, 400 ft maximum distance between sensor and electronic controller. See Table 3 for thermistor output. 4-/2 (4) 7-3/6 (83) Approvals: Underwriters Laboratories, Inc. Canadian Underwriters Laboratories. CE. Fig.. Dimensions of T7079 in in. (mm). M7560 Electrical Ratings: Voltage Input: 24 Vac, 50/60 Hz (+0%, -5%), Class 2 only. 20/230 Vac, 50/60 Hz (+0%, -5%). Accessories: 07048 Heat Conduction Compound, 4 once. 07324A Bulb Holder, duct insertion. 237A Copper Immersion Well. 237E Stainless Steel Well. 32004800-00 0K NTC Sensor. T7047C090 Wall Mounted Sensor Case. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario MV 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2572 04 2

Table 3. 0K thermistor output. Resistance C F 97820-20 -4 32740 0 32 9920 0 50 2500 20 68 0000 25 77 8056 30 86 5326 40 04 3604 50 22 249 60 40 756 70 58 26 80 76 920.9 90 94 Sensor Location The sensor can be located up to 400 feet (22 meters) from the T7079 using standard AWG 8/2 unshielded wire. The sensor may be attached to pipes, in an immersion well, in a wall-mounted case or on a bulb holder. NOTES: For cable runs greater than 25 feet, shielded cable is recommended. Multiple sensors can be parallel-series wired to sense average temperatures in large spaces. See Fig. 2. To maintain control accuracy, the number of sensors wired parallel-series must be n 2 (examples: 4, 9, 6). SENSORS INSTALLATION When Installing this Product.... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. IMPORTANT All wiring must agree with applicable codes, ordinances and regulations. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Location and Mounting Mount the controller on a convenient interior location using the three mounting holes provided on the back of the enclosure (mounting screws are not provided and must be obtained separately). Use controller dimensions in Fig. as a guide. Fig. 2. Parallel-series wiring of sensors. Sensor Mounting TO T7079 M329 IMPORTANT The T7079 is an operation control, not a limit or safety control. If used in applications requiring safety or limit controls, use a separate safety or limit control device in conjunction with the T7079. Mount the sensor(s) in one of the following manners: Hot/cold water sensing: Strap sensor to a pipe or insert in a well (see Fig. 3). Space temperature sensing: Mount on a wall or panel (see Fig. 4). Duct air sensing: Tape to a standard cap or bulb holder. COVER SENSOR LEADS WITH HEAT CONDUCTIVE COMPOUND SENSOR PLACED IN WELL /2 NPT IMMERSION WELL M5249 Fig. 3. Sensor inserted in an immersion well. 3 63-2572 04

T7047C090 WALLMOUNT SENSOR CASE (OPTIONAL) STAGE LED STAGE 2 LED POWER LED SCREW TERMINAL SCREW TERMINAL LEADWIRES TO T7079 SENSOR SENSOR TERMINALS STAGE DIFFERENTIAL ADJUSTMENTS SENSOR J LD DIFF2 LD2 PWR INTERSTAGE DIFFERENTIAL COOL HEAT INTER DIFF J2 2 VOLTAGE INPUT 24 VAC OUTPUT STAGE SWITCHING CAUTION: POSITION SENSOR AWAY FROM SCREW TERMINALS. M330 J5 J4 J3 3 WIRING Fig. 4. Wall-mounted sensor. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Refer to Fig. 5 for locating the appropriate power input, remote sensor input and stage output terminals. To access the terminals, remove the four cover screws and lift off the cover. Refer to Fig. 6 and 7 for typical wiring. IMPORTANT Erratic temperature readings from the sensor can be caused by poor wiring practices that must be avoided to ensure proper operation:. Do not route the temperature sensor wiring with building power wiring. 2. Do not locate the temperature sensor wiring next to control contactors. 3. Do not locate the temperature sensor wiring near electrical motors. 4. Do not locate the temperature sensor wiring near welding equipment. 5. Make sure good mechanical connections are made to both the sensor and the control. 6. Use 90 C copper wire. 2 LOW-VOLTAGE MODELS ONLY. NC COM NO NC COM NO 240V 20V COM TWO-STAGE MODELS ONLY. 3 LINE-VOLTAGE MODELS ONLY. Fig. 5. Board layout for T7079. M756 NOTES:. The larger conduit knockout on the enclosure bottom is for line-voltage applications. 2. The smaller knockout on the enclosure bottom is for low-voltage applications. 3. The sensor knockout is at the enclosure top. SENSOR J J5 J4 NC COM NO NC COM NO STAGE 2 LED STAGE LED M7562 Fig. 6. Typical low-voltage (24 Vac) wiring application. J2 24 VAC L L2 (HOT) 63-2572 04 4

Fig. 7. Typical line-voltage (20 Vac) wiring application. OPERATION Control Algorithm On/Off Control When used in heating mode, the relay is: Energized at setpoint minus differential on temperature fall. De-energized at setpoint on temperature rise. When used in cooling mode, the relay is: Energized at setpoint plus differential on temperature rise. De-energized at setpoint on temperature fall. SENSOR J J5 J4 NC COM NO NC COM NO 240V 20V COM STAGE 2 LED STAGE LED L L2 (HOT) M7563 Each stage LED lights when its stage is energized. The power LED lights when the controller is connected to 20/230 or 24 Vac. Differential (Stage and Interstage) Adjustment The stage and interstage differential values are adjusted using the internal potentiometers (see Fig. 8). Values for setting are marked on the inside cover: Minimum stage differential (DIFF or DIFF2): F. Interstage differential: 0 F to 35 F. NOTES: Actual minimum differential is typically between F and 4 F. It is influenced by device tolerances and the rate of temperature change. The setpoint knob setting is the stage setpoint. The stage 2 setpoint is created using the stage setpoint and the interstage differential: When stage 2 is used for heating, the stage 2 setpoint is the stage setpoint minus the interstage differential. When stage 2 is used for cooling, the stage 2 setpoint is the stage setpoint plus the interstage differential. Fig. 8. Adjustments (potentiometers and switches). TWO-STAGE HEAT. Set ST and ST2 switches to HEAT. 2. Set interstage (INTER) and differential (DIFF, DIFF2) to desired settings. 3. Position the setpoint knob at the setting for stage. TWO-STAGE COOL. Set ST and ST2 switches to COOL. 2. Set interstage (INTER) and differential (DIFF, DIFF2) to desired settings. 3. Position the setpoint knob at the setting for stage. ONE-STAGE HEAT/ONE-STAGE COOL. Set ST switch to HEAT and ST2 switch to COOL. 2. Set interstage (INTER) and differential (DIFF, DIFF2) to desired settings. 3. Position the setpoint knob at the setting for stage. ST: HEAT ST2: COOL DIFF: 2 F DIFF 2: 4 F INTER: 6 F See Fig. 9 for an example setup. Fig. 9. Example one-stage heat/one-stage cool setup. COOL HEAT ST2 ST 80 F 76 F SETPOINT KNOB SETTING: 70 F 68 F 0 0 INTER 0 25 35 DIFF2 0 20 30 DIFF COOL ON 20 30 M7573 STAGE 2 DIFFERENTIAL 2 COOL OFF HEAT OFF STAGE HEAT ON INTERSTAGE DIFFERENTIAL SETPOINT M2062 Keep in mind that, based on the terminal board labels, the stage relay is J4; the stage 2 relay is J5. 5 63-2572 04

CHECKOUT CAUTION Compressor Damage Possible. Rapid cycling can damage compressor and overload electrical circuits. When controlling a compressor, allow at least 5 minutes between cycles to equalize internal pressure. NOTES: Checkout will depend on the type of hookup and controlled equipment. Keep in mind that, based on the terminal board labels, the stage relay is J4; the stage 2 relay is J5. With the controller installed and wired, use the following procedure:. Verify all settings. 2. Apply power. 3. Check for proper equipment response. a. Cooling applications: turn the setpoint knob counterclockwise until the stage LED lights. b. Heating applications: turn the setpoint knob clockwise until the stage LED lights. The stage LED indicates a call for cool/heat. When it lights, the equipment should respond. 63-2572 04 6

7 63-2572 04

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario MV 4Z9 customer.honeywell.com U.S. Registered Trademark 2009 Honeywell International Inc. 63-2572 04 K.K. Rev. 07-09