Thru-Beam 80 to 320 mm 0.05 to 0.08 mm



Similar documents
Cross-beam scanning system to detect slim objects. 100 mm in

Fiber-Optic Photoelectric Sensor

Color Mark Sensor with Red or Green LED E3S-VS

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

How To Read A Pipe From A Sensor

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Optical Fiber Photoelectric Sensor

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Capacitive Prox E2K-X

BOS 73K... BOS 74K...

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Universal Voltage Terminal Photoelectric E3JM

W150: Miniature photoelectric switch series with completely integrated electronics

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

W 36: Mastering complex tasks reliably

W 160: Miniature series for optimum solutions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

U-shaped Micro Photoelectric Sensor

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Absolute Rotary Encoder E6CP

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

Smart Sensing Solutions Since 1954

Adjustment functions for both span and shift have been incorporated

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

LCD Readout Digital Pressure Switch

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Digital display DA 48

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

CZ-K1(P) Series. RGB Digital Fiberoptic Sensor. Instruction Manual SAFETY PRECAUTIONS ACCESSORIES SPECIFICATIONS

CMOS Laser Sensor with Built-in Amplifier

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

intelligent solutions

LUT Luminescence scanners: Seeing what no-one else can

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

photoelectric highlights

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Electrical connection

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Incremental Rotary Encoder E6B2

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Series 8146/5-V37 and Series 8150/5-V37

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Liquid Leakage Sensor Amplifier

USB-500/600 Series Low-Cost Data Loggers and Accessories

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

MULTI-BEAM LS10 Light Screen System

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

Speed Control Relays SX2

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Digital input modules

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

New XUY roller sensors

Photoelectric Sensors/Controls Fiber Optic Miniature Sensors

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Inductive Proximity Sensors

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

HERZ-Thermal Actuators

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Safety technique. Emergency stop module BO 5988 safemaster

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Type Supply voltage Output Connection Sensing range Standard target Timer function Part number Polarized VDC NPN/PNP Pre-leaded 500 mm to 10 m

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Tube Liquid Sensor OPB350 / OCB350 Series

SPECTRO Series SPECTRO-3-FIO-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (cf. p )

USB-500/600 Series Low-Cost Data Loggers and Accessories

Series BOS 5K. ... simply good

Proximity Sensor with All-stainless Housing

Turbine Flow Sensor Series VTR

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Inductive sensor NI10-M18-Y1X-H1141

E3T Miniature Photoelectric Sensors

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1

Transcription:

Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of different colors. The optimum sensitivity setting and other functions are achieved automatically through push buttons. FIBER OPTICS Self Teach Setup Detection of objects as small as.01 mm dia. Off Delay Timer Function 500ms response time Operating & stability indicators Amplifier Specifications * 140 7069AFR4D4NLX ThruBeam 80 to 320 mm 0.05 to 0.08 mm Reflective 30 to 130 mm 0.01 mm Sensing* Maximum Distance Minimum Target Size Input Voltage Current 12 to 24 V DC ± 10% Ripple PP Max. 10% Maximum 30 ma Sensing Output Type Capacity Output Operation NPN open collector Transistor Short circuit protection Maximum 100 ma @ 30V DC Selectable ON Off mode set by the buttons Selfdiagnostic Output Type Capacity Output Operation (Refer to SelfDiagnostic Function) NPN open collector transistor Maximum 50 ma @ 30V DC ON state (pulse) at unstable detection or when output is shortcircuited (OFF when short removed) Response Time Maximum 0.5 ms (Max. 0.7 ms with Crosstalk Prevention) Features Operation Indicator Stable Operation Indicator Sensitivity Shift Function Crosstalk Prevention Function Timer Function Red LED Green LED Shifts the sensitivity for optimum condition Allows close installation of two fiber optic cables Selectable 40ms fixed offdelay timer Environmental Ambient Temperature Ambient Humidity 10 to +50 C Degrees (minimal condensation) 35 to 85% RH Physical Housing Light Emitting Element Weight Wiring Enclosure: Heatresistant ABC, Cover: Polycarbonate, Lock lever: PPS Red LED (modulated) 65g Prewired four conductor 2M cabtyre cable See Fiber Optic Specifications

Dimensions Amplifier Mounting Bracket Units mm Control Locations Dimensions Typical Wiring Diagrams Standard NPN output Connection with fiber optic cable 141

Sensitivity Setting Setting Functions 142

Setting Functions 143

Precautions For Proper Use 144 Fiber Optic Specifications Optical fiber w/o sleeve Optical fiber w/90mm sleeve Optical fiber w/40mm sleeve Max. Sensing Distance (3) Min. Detectable Object Hysterisis Cable Length Allowable Bend Radius Operation Temp/Humidity Fiber Core Sheath Accessories ThruBeam 70622710100 70622710200 70622710300 320mm Standard Cable 0.08mm dia. opaque object (2) General Detection 7069A InflectionResistant Cable Small Diameter Cable Curled Cable Small Diameter High Precision 1 The sensing range (reflective) is determined by using an object of nonglossy white paper (50 x 50mm for standard range, 30 x 30mm for small diameter). 2 Minimum Sensing object (opaque object) is the value under the best conditions. 3 Note that the sensing range may be reduced up to 20% depending on the condition of the cut. Coaxial Reflective ThruBeam Reflective ThruBeam Reflective ThruBeam Reflective 70622711100 70622711200 70622711300 130mm (1) 0.01mm dia. gold wire less than 15% Minimum Radius 25mm 4M4 Nuts 2Lock Washers 2M6 Nuts 1Lock Washer 70692720100 320mm 0.08mm dia. opaque object (2) 70692721100 80mm (1) 0.01mm dia. gold wire less than 15% Freely cuttable 2M Minimum Radius 4mm 70692730100 70692730200 70692730300 80mm 0.05mm dia. opaque object (2) Minimum Radius 5mm 70692731100 70692731200 70692731300 30mm (1) 0.01mm dia. gold wire less than 15% Minimum Radius 25mm 40 to + 70 Degree C / 35 to 85% RH (condition must be avoided) Acrylic Polyethene 4M4 Nuts 2M6 Nuts 4M3 Nuts 4M4 Nuts 2Lock 1Lock 2Lock 2Lock Washers Washer Washers Washers 70692722100 90mm 0.05mm dia. opaque object (2) 2M 4M4 Nuts 2Lock Washers 70622740100 40mm (1) 0.01mm dia. gold wire less than 15% 500mm Minimum Radius 25mm 2M4 Nuts 1Lock Washer

Cables and Accessories 145

Typical Sensing Curves 146

Ordering Code 7069A F R 4 D 4 N L X BASIC MODEL TYPE F Fiber Optic SOURCE R Red modulatedbeam LED OPERATION 4 Light/Dark operate DELAY D Switch selectable no delay off delay (45ms fixed) NUMBER OF WIRES 4 Four wires POWER REQUIREMENT N 24V DC OUTPUT L Logic (NPN) FEATURES X Standard Note: Fiber optic cables must be chosen when buying 7069. ACCESSORIES 70623200500 Long Range Lens Attachment 70623200400 SideView Lens Attachment 70693200600 Bracket FIBER OPTIC CABLES (Required for operation) 70622710100 70622711100 70622710200 70622711200 70622710300 70622711300 70692720100 70692721100 70692730100 70692731100 70692730200 70692731200 70692730300 70692731300 70692722100 70622740100 Before starting your design, read the safety statement on the inside back cover of the ATC catalog. 147