Industrial Controls SIRIUS Controls



Similar documents
Unit 33 Three-Phase Motors

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

EET272 Worksheet Week 8

Lab 8: DC generators: shunt, series, and compounded.

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Module Title: Electrotechnology for Mech L7

Three phase circuits

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Three-phase monitoring relay CM-PFE

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

INDUCTION REGULATOR. Objective:

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Power Quality Paper #3

Single Phase Soft Starter

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

C Standard AC Motors

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS

Three-phase AC circuits

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

PHASE CONVERSION TECHNOLOGY OVERVIEW

Occupational Profile: Electrical & Electronics Engineering Technician

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Welcome to Linear Controls Quarterly Training

Motor Protection Voltage Unbalance and Single-Phasing

Lab 14: 3-phase alternator.

Three Phase Circuits. Three Phase Circuits

All about Motors. Page. Motor protection 8-3. Notes on engineering Circuit documents Power supply Control circuit supply 8-24

Synchronous motor. Type. Non-excited motors

Automatic Voltage Regulator User s Manual

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Earth Fault Detection Basics in Theory

Understanding the Alternator

8 Speed control of Induction Machines

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Prepared By: Sheilani Binti Shaari Department of Electrical Engineering/PKB

How To Balance Three Phase Power In A Balanced System

Line Reactors and AC Drives

Low Voltage Controls & Distribution

SYNCHRONOUS MACHINES

Magnetic Starter - 30A, 120/240V Coils

3-Phase AC Calculations Revisited

Rotary Phase Converters

Electrical Symbols and Line Diagrams

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Number 1 in efficiency

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Rules for Classification and Construction Additional Rules and Guidelines

Principles and Working of DC and AC machines

Three-phase asynchronous motors Generalities and ABB proposals for the coordination of protective devices

Contactor and Starter Ratings

The following table shows approximate percentage wise the

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

How To Select A Solid State Relay For A Three Phase Resistive Load

THREE-PHASE INDUCTION MOTOR March 2007

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Principles of Adjustable Frequency Drives

Motor Fundamentals. DC Motor

IV. Three-Phase Induction Machines. Induction Machines

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

SX460. Generator Automatic Voltage Regulator Operation Manual

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Speed Control Motors. Speed Control Motors. Brushless Motor's Structure and Principle of Operation H-40. Structure of Brushless Motor

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

BALANCED THREE-PHASE AC CIRCUIT

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

AC Generators and Motors

WIND TURBINE TECHNOLOGY

Chapter 12: Three Phase Circuits

Application example and brief instruction 04/2015. LOGO! App V3.0. LOGO! 8 and LOGO! 7

ABR Brake Rectifier Instruction Manual

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

How can a charging station for electric vehicles be set up simply and safely?

7. Reactive energy compensation

, User s Manual

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Chapter 12 Three-Phase Circuit

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

DIRECT CURRENT GENERATORS

Instrument Transformer Wiring Troubleshooting Guide Three Phase Meters Revision 0, Initial Issue, April 26, 1993

How To Understand The Electrical Power Supply Of A Power Supply System

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Addendum to the Operating Instructions

Simulation of Electric Drives using the Machines Library and the SmartElectricDrives Library

Product Guide. Low voltage grounding system. Answers for industry.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

VOLTAGE REGULATOR AND PARALLEL OPERATION

DC Motor control Reversing

AN SMSC Design Guide for Power Over Ethernet Applications. 1 Introduction. 1.1 Power Over Ethernet

Transcription:

Industrial Controls SIRIS Controls Star-delta (Wye-delta) Switching of Three-phase Induction Motors Transient Current Peak Reduction using a Preferred Circuitry Configuration for Clockwise and Counterclockwise Motor Rotation Functional Example No. CD-FE-III-001-V10-EN

Comments Sirius Functional Examples are functional, tested automation configurations based on A&D standard products intended for simple, quick and economic implementation of automation tasks in low-voltage controls. Each of these Functional Examples covers a frequently occurring subtask of a typical customer problem within low-voltage controls. 1 Introduction... 3 2 Function... 4 1.1 Description of the Functionality for Clockwise Motor Rotation...4 2.1.1 The Preferred Circuitry Configuration is Implemented...4 2.1.2 The Preferred Circuitry Configuration is not Implemented...5 2.2 Changing the Direction of Rotation from Clockwise to Counterclockwise...6 2.3 Device Rating for Standard Start-up...6 2.4 Favorable and nfavorable Circuitry Configurations...7 3 Assembly and Wiring... 9 3.1 Main Circuit Overview...9 1.1 Control Circuit Overview...9 4 Siemens The Solution for Complete Contactor Assemblies for Star-delta Starting (Wye-delta Starting) up to 75 kw for one Direction of Rotation... 10 5 Contact Partner... 11 6 Guarantee, Liability and Support... 11 7 Bibliography... 11 Sirius Controls Page 2/11 CD-FE-III-001-V10-EN

1 Introduction Star-delta (wye-delta) starting continues to be used for switching on 3-phase induction motors. When this type of connection method is used, the starting current is reduced to 1/3 of the current required for direct switching. When switching from a star (wye) circuit to a delta circuit, transients can occur in the motor, which, further intensified by an unfavorable constellation of line frequency and inductor field, lead to the development of larger current peaks than is the case if the stopped motor is directly switched into a delta connection. In an unfavorable case, the following problems could occur: Short-circuit devices could trip, The delta contactor could become welded or be subject to high contact erosion, The motor could be subject to extreme dynamic overloading. A preferred circuitry configuration for star-delta (wye-delta) starters is described in this Functional Example. When the main circuit is connected in a favorable manner, it is possible to reduce the transient currents and current peaks that develop when the motor is switched over from a star (wye) connection to a delta connection. Sirius Controls Page 3/11 CD-FE-III-001-V10-EN

2 Function Two different types of motor connections are often listed in star-delta (wye-delta) starter circuit diagrams: One for clockwise and one for counterclockwise motor rotation. When installing the motor, care should be taken to ensure that the transient current peaks are as small as possible. Correct wiring of the motor terminal board is essential. 1.1 Description of the Functionality for Clockwise Motor Rotation 2.1.1 The Preferred Circuitry Configuration is Implemented The vector diagram illustrated below shows the voltages that develop in a motor with clockwise rotation when the motor is switched from a star (wye) to a delta connection. In this case, the motor terminals are correctly connected according to the preferred circuitry configuration, meaning that phase L1 is connected to the motor terminals 1 and V2, L2 is connected to V1 and W2, and is connected to W1 and 2: L1 L2 L1 L2 1 V1 W1 1 V1 W1 2 V2 W2 2 V2 W2 Fig. 1: Correct connection of the motor phases for clockwise rotation Phase sequence The rotor lags during the idle pause L1 L 1 N L1 L 1 N L1 N L1 L2 L2 Fig. 2: Vector diagram for switching from a star (wye) connection to a delta connection for clockwise motor rotation when the motor phases are correctly connected During the idle changeover delay, the rotor lags behind the phase sequence. The magnetic field induces a damped residual voltage, which is listed here in the voltage Sirius Controls Page 4/11 CD-FE-III-001-V10-EN

vector diagram for phase L1: L 1 ' N. When switching over to a delta connection (Fig. 1 and Fig. 2), the stator winding carrying this residual voltage is supplied with the line voltage L1. Thanks to the favorable vector position of the residual voltage L 1 ' N and the line voltage L1, which have approximately the same values, the differential voltage is relatively small. Thus, the current peaks resulting from this voltage also remain small. 2.1.2 The Preferred Circuitry Configuration is not Implemented The motor also rotates clockwise when the motor terminals are connected as follows: Phase L1 is connected to motor terminals 1 and W2, L2 is connected to V1 and 2, L1 L2 1 V1 W1 2 V2 W2 and is connected to W1 and V2. Fig. 3: Incorrect connection of the motor phases also resulting in clockwise motor rotation Both the lagging residual voltage and the damped residual voltage are active in the stator. When the motor is switched to a delta connection, the phase winding with the vector L 1 ' N is supplied with the line phase L1 L2. However, each of these voltages has a different vectorial direction. The differential voltage is high, thus causing a correspondingly high transient current peak. Switching from a star (wye) connection to a delta connection therefore results in the following vector diagram: Phase sequence L1 The rotor lags during the idle pause L 1 N L1 L1 L 2 N L 1 N L1 L2 L2 L2 Fig. 4: Vector diagram for connecting the motor phases according to Fig. 3, resulting in a large transient current peak Sirius Controls Page 5/11 CD-FE-III-001-V10-EN

2.2 Changing the Direction of Rotation from Clockwise to Counterclockwise When the motor rotates counterclockwise it is sufficient to exchange two phases in any position. Then the same conditions would prevail as described above for clockwise rotation. In order to also keep the transient current peak as small as possible in this case when switching from a star (wye) connection to a delta connection, the wiring must be carried out as illustrated below: L1 L2 L1 L2 1 V1 W1 1 V1 W1 2 V2 W2 2 V2 W2 Fig. 5: Correct connection of the motor phases for counterclockwise rotation of the motor Refer to Section 3 for information regarding the wiring of the main current and the control current. The circuit diagrams for contact assemblies for star-delta (wye-delta) starting with clockwise and counterclockwise motor rotation are illustrated in the preferred circuitry configuration. 2.3 Device Rating for Standard Start-up Star (wye) contactor: I e Motor x 0.33 Line/delta contactor: I e Motor x 0.58 Overload relay: I e Motor x 0.58 Sirius Controls Page 6/11 CD-FE-III-001-V10-EN

2.4 Favorable and nfavorable Circuitry Configurations The different types of connection combinations are summarized here together with the delta connection wiring. nfavorable versions Rewiring Favorable versions clockwise, unfavorable clockwise, favorable 1: L1 2: L2 1: L1 2: V1: L2 V2: V1: L2 V2: L1 W1: W2: L1 W1: W2: L2 clockwise, unfavorable clockwise, favorable 1: L2 2: 1: L2 2: L1 V1: V2: L1 V1: V2: L2 W1: L1 W2: L2 W1: L1 W2: clockwise, unfavorable clockwise, favorable 1: 2: L1 1: 2: L2 V1: L1 V2: L2 V1: L1 V2: W1: L2 W2: W1: L2 W2: L1 counterclockwise, unfavorable counterclockwise, favorable 1: L1 2: L2 1: L1 2: V1: V2: L1 V1: V2: L2 W1: L2 W2: W1: L2 W2: L1 counterclockwise, unfavorable counterclockwise, favorable 1: 2: L1 1: 2: L2 V1: L2 V2: V1: L2 V2: L1 W1: L1 W2: L2 W1: L1 W2: counterclockwise, unfavorable counterclockwise, favorable 1: L2 2: 1: L2 2: L1 V1: L1 V2: L2 V1: L1 V2: W1: W2: L1 W1: W2: L2 Comment: When two phases in the circuit are exchanged to change the direction of rotation, the connection is automatically switched from the more favorable connection to the less favorable one and vice versa. = Transient current factor = transient current peak/starting current peak In theory, the transient current factor has a maximum value of 2. Sirius Controls Page 7/11 CD-FE-III-001-V10-EN

For example, measured: Favorable connection: = 0.8 nfavorable connection: = 1.37 Sirius Controls Page 8/11 CD-FE-III-001-V10-EN

3 Assembly and Wiring 3.1 Main Circuit Overview In the following graphic, the preferred circuitry configuration for the main circuit is illustrated for a star-delta (wye-delta) connection for clockwise and counterclockwise motor rotation. L1 L2 Line CCW Line CW Delta CCW Delta CW Y CCW rotation L1-V1 / V2- L2-1 / 2-L1 -W1 / W2-L2 W1 V1 1 M 3 ~ W2 V2 2 CW rotation L1-1 / 2- L2-V1 / V2-L1 -W1 / W2-L2 Fig. 6: Main circuit of the contactor assembly for star-delta (wye-delta) starting 1.1 Control Circuit Overview The control circuit for the main circuit shown above is illustrated below. L1/L+ Line CCW Y Line CW T Delta CCW Y Delta CW N/L- Timing relay Star (wye) contactor Delta CCW Delta CCW Line CCW Line CW Fig. 7: Control circuit of the contactor assembly for star-delta (wye-delta) starting Sirius Controls Page 9/11 CD-FE-III-001-V10-EN

4 Siemens The Solution for Complete Contactor Assemblies for Star-delta Starting (Wye-delta Starting) up to 75 kw for one Direction of Rotation Contactor assemblies 3-phase motor AC-3/400 V Size [kw] [A] Order No. Completely wired and tested for AC 230 V, 50/60 Hz 5.5 12 S00-S00-S00 3RA14 15-8XB21-1AP0 7.5 17 S00-S00-S00 3RA14 16-8XB21-1AP0 11 25 S0-S0-S0 3RA14 23-8XC21-1AL2 15/18.5 32/40 S0-S0-S0 3RA14 25-8XC21-1AL2 22/30 50/65 S2-S2-S0 3RA14 34-8XC21-1AL2 37 80 S2-S2-S2 3RA14 35-8XC21-1AL2 45 86 S2-S2-S2 3RA14 36-8XC21-1AL2 55 115 S3-S3-S2 3RA14 44-8XC21-1AL2 75 150 S3-S3-S2 3RA14 45-8XC21-1AL2 For further information, for example, regarding other voltages and/or accessories, please refer to the LV 1 catalog. Sirius Controls Page 10/11 CD-FE-III-001-V10-EN

5 Contact Partner Technical Assistance for Low-voltage Controls and Distribution Personally from Mon. Fri. 8:00 am to 5:00 pm (CET) Telephone: +49 (911)-895-5900 E-mail: technical-assistance@siemens.com Internet: http://www.siemens.de/lowvoltage By fax, around the clock Fax: +49 (911)-895-5907 6 Guarantee, Liability and Support We are not liable for any of the information contained in this document. We are not liable for any damage caused by use of the examples, advice, programs, configuration and performance data, etc. described in this Sirius Function Example, independent of the legal ground this is based upon, unless we are imperatively liable according to the product liability law due to, e.g., cases of premeditation, an act of gross negligence, injury to life, body or health, or unless the quality of a product has been guaranteed, or due to fraudulent concealment of a defect or serious breach of contract. Damages due to serious breach of contract are, however, restricted to prevalent and predictive contractual damages, in as much as premeditation or gross negligence are not existent or there is no imperative liability due to injury to life, body or health. This does not constitute a change in the burden of proof to your disadvantage. 7 Bibliography [1] Schalten, Schützen, Verteilen in Niederspannungsnetzen, Fachbuch Siemens [Switching, Protection and Distribution in Low-Voltage Networks (Siemens reference book)] [2] L.Vercelli, Sprecher&Schuh AG, CH-5000 Aarau: Rechts- und Linkslauf der Motoren bei Y-D-Anlauf in ELEKTRONIK (CH) 2/1978, Seite 53 [ Clockwise and Counterclockwise Rotation in Motors For Star-delta Starting (Wye-delta Starting) in ELEKTRONIK (CH) 2/1978, p. 53] Copyright 2006 Siemens A&D. Propagation or reproduction of these Safety Function Examples or parts there of is not permitted unless expressly allowed by Siemens A&D. Sirius Controls Page 11/11 CD-FE-III-001-V10-EN