AIR CONDITIONING TECHNOLOGY



Similar documents
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Why and How we Use Capacity Control

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Chapter 3.4: HVAC & Refrigeration System

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Heat Recovery In Retail Refrigeration

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Characteristics of Evaporators

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

UNIT 2 REFRIGERATION CYCLE

Chilled Water HVAC Systems

How To Understand Evaporator

Lesson 36 Selection Of Air Conditioning Systems

Closed Circuit Cooling Towers

New Trends in the Field of Automobile Air Conditioning

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Wet Bulb Temperature and Its Impact on Building Performance

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

5.2. Vaporizers - Types and Usage

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Energy Efficiency Best Practice Guide Industrial Refrigeration

MAC-120HE-01 Air-Cooled Chiller

Refrigeration Basics 101. By: Eric Nelson

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HVAC Systems: Overview

Nirvana. Cycling Refrigerated Dryers

How To Clean Water From An Ammonia Refrigeration System

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

- White Paper - Data Centre Cooling. Best Practice

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

DEFROSTING. Service Engineers Section Technical Bulletin No 3

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Commissioning - Construction Documents (Page 1 of 6)

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

3/29/2012 INTRODUCTION HVAC BASICS

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Desuperheater Online Program Sizing Guidance

Automobile Air Conditioning Primer

We have been working in an ideal climate for thirty years.

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

State of the Art Energy Efficient Data Centre Air Conditioning

Increasing the evaporation temperature with the help of an internal heat exchanger

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

HEATING, VENTILATION & AIR CONDITIONING

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Condensing unit type EPSILON-ECHOS LE Technical information manual

Evaporative Cooling for Residential and Light-Commercial

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

*At the AHRI Standard flow rate of 3 gpm/ton, using today s efficient chillers, the ΔT is 9.3 F rather than the 10 F often assumed.

A Guide to Trouble-Free Cooling Towers

How To Design A Refrigeration System

Fundamentals of Mechanical Refrigeration Systems

The Different Types of Air Conditioning Equipment for IT Environments

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Low GWP Replacements for R404A in Commercial Refrigeration Applications

GAS TURBINE INLET AIR CHILLING FOR LNG

Steam System Best Practices Condensate System Piping

Cooking at the Speed of light!

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

Waste Heat Recovery through Air Conditioning System

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

High Pressure Ammonia Systems New Opportunities

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

News in Data Center Cooling

Heat Rejection Options in HVAC Systems

NSN

Central Air Conditioning Plants

TRAINING, EXAMINATION AND CERTIFICATION

Testing methods applicable to refrigeration components and systems

System Trouble Shooting Fault Location REFRIGERATION AND AIR CONDITIONING. Fitters notes

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Air Conditioning 101. STN Presentation AC101

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Using Portable Spot Air Conditioners in Industrial Applications

P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Transcription:

AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air conditioning system to ambient air. This month we consider alternative means of heat rejection. WATER COOLED Condensers This section deals with the application and use of water-cooled condensers (shell and tube type) in the refrigeration cycle. Earlier in this series we outlined the thermodynamic process by means of a Pressure-Enthalpy diagram, the primary functions performed by the condenser being de-superheating, condensing and sub-cooling. Water-cooled condensers are available as a separate component, for field use, within site built equipment or as a replacement item following a failure. Factory built packages will normally incorporate the condenser fitted within the complete unit. Water piping and associated controls to the vessel are then installed on site. FIGURE 1 The Bitzer shell and tube cleanable water-cooled condenser employs the latest development in high efficiency condenser tubes. Tubes are integral - fin copper, roll expanded into thick tube sheets, are removable and can be replaced in field service. The cast iron heads are also removable. Marine units are available for seawater applications with the appropriate material specifications. FIGURE 2 FIGURE 3 FIGURE 4 Figure 4 shows the general arrangement of connections to a typical watercooled condenser. Selecting and sizing a condenser is usually a straightforward process using manufacturers published data. The following information is required before selection tables can be entered: 1. Total heat rejection. 2. Evaporating temperature. 3. Condensing temperature. 4. Entering water temperature. 5. Fouling factor required. (*)

* This factor allows for the fouling of tube surfaces on the water side, by sediment or deposits and selection is not usually made on a clean basis. Water piping to the vessel should be arranged in order to maintain constant condensing pressure where the condenser supply water temperature varies. For cooling tower applications, a three way-diverting valve is normally used to modulate the amount of water flowing through the condenser. An alternate, but less accurate means of controlling tower water is with a tower fan thermostat. In all instances, it is recommended that a strainer be installed upstream of the water regulating valve to protect the valve from seizure. Vessel connections and positioning varies according to manufacturer and detailed information should be sought at the design stage. Condenser vessels should be mounted horizontally and in a level plane. Adequate space (equal to the vessel length) should be provided at either end of the vessel to permit tube removal should this become necessary. Cleaning access must also be considered. Good refrigeration piping practice must be followed to assure leak free connections. After the refrigeration pipework is installed, the entire system must be pressure tested for leaks. The system must then be evacuated and moisture free before it is charged with refrigerant. The system design and installation must be carried out in accordance with current practice and regulations. Since the long term performance of condensers will be adversely affected by poor water conditions, it is recommended that an analysis of the condenser water be made and a treatment system provided when installing the condenser. Problems to be addressed include scaling of the condenser surfaces corrosion, algae or slime. Those who are qualified and competent to prescribe what is required should only undertake water treatment. Freeze prevention is necessary as severe damage can be caused to the structure of the vessel. If the condenser will be subjected to ambient temperatures below 0ºC, it must be protected from freezing. If the condenser is to be idle during cold weather, it is essential that it be drained of all water. It is possible to freeze tubes, even in warm weather, by improper maintenance procedures. If refrigerant is stored in the condenser, and gas is removed from the condenser, allowing pressure to drop below the saturation value of 0ºC, water in the tubes can freeze. To avoid this, when transferring refrigerant, always have condenser water flowing and / or remove liquid refrigerant before releasing pressure. Only suitably qualified and certified persons should engage in this work. Condenser tubes should be cleaned periodically to assure optimum condenser efficiency. Frequency of cleaning will depend on individual water conditions and the water treatment system employed. A suitable cleaning schedule should be determined and included in the overall maintenance programme.

Selection Procedure This will vary between one manufacturer and another. The following procedure is used to select Dunham Bush Water Cooled Condensers: THR = Total Heat of Rejection (350 000 Btu/hr / 102.6 kw) EWT = Entering Water Temperature (80 Deg F /26.6 Deg C) SDT = Saturated Discharge Temperature (105 Deg F / 40.5 Deg C) LWT = Leaving Water Temperature AT = Approach Temperature 1 Add required fouling factor to total THR For normal cooling tower applications where a fouling factor of 0.000176 W/m 2 K (0.001 Btu/hr ft 2 R) is specified, add 21%. Corrected THR = THR x 1.21 = 350 000 x 1.21 = 423 500 Btu/hr 2 Calculate Approach Temperature: Approach Temperature = SDT - EWT = 105 Deg F - 80 Deg F = 25 R 3 On appropriate capacity graphs, plot corrected THR against Approach Temperature and read required water flow rate and pressure drop. FIGURE 5 4 Calculate the Water Temperature Rise: THR 102.6 kw = = 4.62 K 4.187 x Flow Rate (l/s or kg/s) 4.187 x 5.3 l/s 5 Calculate Leaving Water Temperature: LWT = EWT + Temperature Rise = 26.6 + 4.62 = 31.22 Deg C Note: The un-corrected THR is used when calculating the water flow rate.

COOLING TOWERS Many years ago, numerous air conditioning and refrigeration systems rejected heat to a continuous stream of water, either from a natural body of water or purchased from a water utility supplier, which was then discharged back into its source. Increased water supply costs and problems with higher temperature discharge water severely affected these methods. To overcome these problems, a continually recirculating mass of water absorbs heat from the Water Cooled Condenser and is then passed through a cooling tower in order for the heat energy to be removed thus allowing the water to return to the condenser at the correct temperature. Process heat exchangers can also be connected to cooling towers to facilitate the removal of heat energy from a process plant installation. The water consumption rate of a cooling tower system is only approximately 5% of a once-through method, making it the least expensive system to operate compared with purchased water supplies. The factors to be considered in sizing a cooling tower are the heat load, approach temperature and wet bulb temperature. The heat load in determined by the process duty, the local climate determines the wet bulb temperature and the remaining factor, approach temperature, is determined by how low the water has to be. The driving force for heat transfer is the difference in enthalpy between the air contacting the water surface and the bulk air stream. The enthalpy content of moist air is the summation of the sensible heat content of both the water and air present, the latent heat of the water vapour, plus (for non-saturated mixtures) the superheat of the water vapour. At a given temperature, air is capable of co-existing with only a limited quantity of water vapour, the amount being determined by the partial vapour pressure of the water vapour in the mixture. If the pressure of the vapour in the air is lower than the atmospheric pressure then evaporation can take place. The quantity of water vapour present in the air is small, typically 5.0 and 20.0 grams of vapour/kg of dry air (g/kg). Wet Bulb Temperature: The temperature to which the air would have to be cooled in order to reach 100% saturation with moisture. Approach Temperature: The difference between the required cooled water temperature and the wet bulb temperature; determines how difficult the duty is. A small approach means a larger cooling tower. FIGURE 6

Heat load: A function of the quantity of water to be cooled and cooling range. For a fixed heat load, various combinations of range and approach will be possible; the graph in Figure. 7 shows the effect on tower size. A large range and small flow results in a smaller cooling tower. FIGURE 7 A cooling tower cools the water by using a combination of heat and mass transfer. The entering water is distributed through the tower via spray nozzles over plastic fill packing, which provides a large water surface area to be exposed to ambient air. The ambient air can be circulated naturally using available wind currents, or using mechanical fans (a mechanical draught tower is far more dependable as it uses a known volume of air, as opposed to natural draught which is generally used on large hyperbolic towers for electricity generation). Most of the heat is transferred to the air through evaporation of a portion of the circulating water (approximately 1% for every 8 C range), the remainder through sensible heat transfer. The difference in temperature between the water entering and leaving the cooling tower is known as the cooling range. Accordingly, the range is determined by the cooling tower heat load imposed by process and water flow rate, not by the size or capability of the cooling tower. Mechanical draught towers are classified as either forced draught, where the fan is located in the incoming ambient air stream, or induced draught which has the fan situated at the tower exit position to draw the air stream through the tower. Forced draught towers are characterised by high air entrance velocities and low exit velocities, which can make them susceptible to recirculation, giving instability in performance. Induced draught towers have an air discharge velocity of from 3-4 times higher than their air entrance velocity, and the location of the fan in the warm air exit stream provides excellent protection against the formulation of ice on the mechanical components. Induced draught towers can be used on installations as small as 5 m 3 /hr and as large as 150 000 m 3 /hr. Tower types are also classified by airflow. In a counter-flow tower, air flows vertically upwards through the heat transfer medium (plastic fill packing), counter to the downward flow of the water. In a cross flow tower the movement of the air through the fill is across the direction of the waterfall. Each type of tower has distinctly different fan power and pump head energy consuming characteristics. Figure 8 - Crossflow Cooling Tower with propeller fan - Induced Draught configuration Figure 9 - Counter-flow Cooling Tower with centrifugal fan - Forced Draught configuration

Energy is absorbed in driving the fan necessary to create proper air movement through a cooling tower. The pump head of a cooling tower also contributes to the expended energy in the operation of the condenser water pump. Therefore, manipulation of one or both of these power consuming aspects as a means for adjusting for changing loads or ambient conditions should have some beneficial effect upon the towers energy requirements. Deciding which of these aspects to control and how to do it will depend primarily upon specific characteristics and restrictions of the condenser / chilled water system. On a cooling tower serving a process, which benefits from colder water temperatures, any attempt at fan manipulation should only be made when the cold water temperature reaches a level that results in optimum system energy use, which can vary with system design. Having determined the level at which control of the tower s cold water temperature will be most conducive to total system power reduction, several energy efficient methods to achieve this control are available. The most commonly used methods follow in general order of increasing effectiveness: Fan Cycling: At any time that the tower is capable of producing a water temperature colder than the control level, the fan can be shut off for the period of time it takes the water to build back up to the control point. A thermostatic device can be used to accomplish this cycling automatically, which works well provided that there is a sufficient spread of temperature available between the make and break levels (differential) to ensure that the fan motor windings insulation does not become overheated by an excessive number of starts per hour. Fan Capacity Variation at Constant Speed: To achieve a balance between the operational requirements of the chiller and the wish to conserve cooling tower fan energy, control of fixed speed fans seems to be limited to a series of speed steps, resulting in either an under or over achievement of the goal being sought. The control effort would be much simpler if the fan capacity could be varied such that the tower would track the load at a constant cold-water temperature. The means to accomplish this result exists in the form of automatic variable pitch propeller fans, designed specifically for cooling tower use. These can be retrofitted to existing installations. Progressive Variation Of Fan Speed: The load of a cooling tower fan can theoretically be made to track the curve indicated in Fig.14 by the use of a frequency modulating device (power inverter). The ability of these controllers to vary frequency results in a capability to infinitely vary the fan speed. Total variability is restricted on cooling tower applications, which is a characteristic of the fan itself. There is an obvious need to restrict over speeding, and most fans do have at least one critical speed so it is wise to predetermine what this critical speed is. Most frequency modulating devices permit avoidance of selected frequencies, so that critical speeds will be passed without risk of extended operation at those speeds.

Fan control is, without doubt, extremely beneficial in varying the thermal performance level of a cooling tower when applied properly. However, misapplication can also have a detrimental effect upon the ultimate energy costs of some air conditioning systems. An induced draught crossflow cooling tower can achieve 10-15% performance at zero fan speed due to natural air movement, while the enclosed nature of a forced draught tower prevents this advantage. Today s wide range of open and closed circuit, factory assembled evaporative cooling towers are designed with a major consideration to ease of access for routine maintenance and servicing. All separate components are easily removable, with some units having detachable panels for added admission to motors etc. Evaporative cooling systems are without doubt the least expensive cooling technique, whether applied to Air Conditioning, Refrigeration or other Process Cooling Applications. Dry air coolers are not only larger, heavier and noisier than evaporative coolers, but they demand much more fan energy and a far higher air intake, plus having a higher initial outlay cost. Evaporative cooling towers are ideal in Air Conditioning systems partly because they can achieve lower temperatures from a given ambient than other evaporative or dry air equipment. User maintenance however, is extremely important; as with any application, to contain bacteriological dangers. The evaporative cooler is an efficient alternative to the cooling tower, which compares quite closely in terms of performance, but both are well ahead of the dry air cooler, as seen below. FIGURE 10 and 11

Comparison for Cooling tower, evaporative cooler / condenser and dry air cooler, applied to the same heat load For Against Tower Lowest temperature Water treatment Lowest capital cost Maintenance Smallest size / weight Water supply / drain Low energy costs Evaporative Cooler and Lower temperatures Higher capital costs than tower Condenser Lower capital cost Higher temperature than tower Smaller size / weight Water supply / drain than dry cooler Lower water treatment costs than tower Low energy costs Dry Cooler Little maintenance Highest capital cost Little water treatment Highest running cost Electro / mechanical Highest temperatures services only Greatest weight Largest area Most noise Most controls Highest energy cost NEXT MONTH: Part 10 - Expansion devices