ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW



Similar documents
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

PSR The compact range Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Manual motor starter MS116

Products and solutions for lifting systems

Aluminium Standard. Technical Data. Included in delivery

R.C.C.B. s two-pole LEXIC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Certificate of Compliance

Technicaldata General

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

Low Voltage Switchgear MNS is with MSpeed

Problem / Solution. The problem:

Control. Overview. Contents

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Terminal Boxes Series 8146

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Electronic, Digital and Mechanical Vibration Switches

Installation Guide. DEVIreg 530. Electronic Thermostat.

Plug and Socket Devices CES 63 A Series 8579

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Linear Luminaire with LED Series EXLUX 6402/2

Emergency voice communications Product Name

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Drayton Digistat +2RF/+3RF

Series 8146/5-V37 and Series 8150/5-V37

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Plug and Socket Devices SolConeX 16 A Series 8570

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

GUIDE TO THE AM2 EXAM

LIEBERT VNSA Installation Sheet

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ACS-30-EU-EMDR-10-MOD

Control Box Wiring For PRSstandard Tool

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

THERMAL RELAYS, MOTORSTARTERS

HERZ-Thermal Actuators

Contractors Guide Central Inverter System Installation

SECTION LOW VOLTAGE LIGHTING CONTROLS

A good connection. International approvals.

HMI display Installation Guide

Oil and Coolant Circulating Heating System. Model - OCSM

GRX-PWM Pulse Width Modulation Interface

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Number 1 in efficiency

Triac Printed Circuit Board Replacement

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

High Power Connectors for Power Supply and Power Circuits

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Installation & User Instructions

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Product Guide. Low voltage grounding system. Answers for industry.

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ATS - Automatic Changeover

FAQs-Main switchboard design criteria

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Air damper actuators

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

FIREDEX Conventional Fire Panels

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Operating Instructions

SMS 4 / SMS 5 safety mat Product information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IEC gg & am STANDARD LOW VOLTAGE FUSE

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Maximum Demand Control

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

GeekDesk Max Instructions for Assembly & Use

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Compact pressure switch Flameproof enclosure Ex d Model PCA

CO2 Alarm. Operation. Application

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Changing industry standards: friend or foe?

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

T7079A,B Solid State Remote Temperature Controllers

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

The solution for Europe: Type 2 charging socket with or without shutter

Switches and Indicators. Swisstac

SELECTION, APPLICATION AND MAINTENANCE

Transcription:

ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW

New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years ago. ADS8 builds upon the strengths of its predecessor and offers even easier installation, excellent performance and full compliance with the latest international standards. Among the enhanced features, the new range is available for direct-on-line applications up to 9kW and is fully rated for AC3 duty. Separate overload relays offer flexibility and optimise stockists shelf space Robust IP54 steel enclosure offers excellent earth continuity Fixing centres and gland entry positions identical to ADS7 Part numbers based on ADS7 numbers for easy transition Easy six-stage assembly cuts installation time Captive cover screws and quick-release contactor mounting All internal screws have dual flat-slot/cross-slot heads 220-240V or 380-415V versions available Fully compliant with IEC 60947-4-1 and BS EN 60947-4-1 Materials meet RoHS criteria New Catalogue Number Selection With the introduction of the new range, we have adapted the existing ADS7 catalogue numbering system and where feasible replaced the 7 with an 8, or alternatively inserted the number 8 before the catalogue number. This new range supersedes the old ADS7 metal clad enclosure and will be available from July 2005. Available in 220-240V and 380-415V versions. Starters DOL Surface Mounting Starter without Thermal Overload Relay (Fitted with Start and Stop/Reset Push buttons). ADS7 Old Catalogue No. ADS8 New Catalogue No. 220-240V Full Load Current (415V MAX, 3ph, AC-3) kw HP Amps 27ADS1X 28ADS1X 9 12.5 18 Old Catalogue No. New Catalogue No. 380-415V Full Load Current (415V MAX, 3ph, AC-3) kw HP Amps 47ADS1X 48ADS1X 9 12.5 18 * See alternative coil voltages from the coil selection table. 1

Overload Relays Overload relays, supplied separately, provide three-phase protection and phase-failure sensing in accordance with BS EN 60947-4-1. All are ambient temperature compensated between -5 C and 40 C. A changeover trip contact is provided allowing for manual reset. Thermal Overload Relay Selection with ADS7 to ADS8 Comparison ADS7 ADS8 Old Catalogue No. Full Load New Catalogue No. Current (A) Full Load Current (415V MAX, 3ph, AC-3) Amps kw HP TT87 0.74-1.11 8TT87 0.63-1.0 0.37 0.50 TT88 1.11-1.66 8TT88 1.0-1.6 0.55 0.75 TT89 1.66-2.5 8TT89 1.6-2.5 1.10 1.50 TT90 2.5-3.7 8TT90 2.5-4.0 1.50 2.00 TT91 3.7-5.6 8TT91 4.0-6.0 2.20 3.00 TT92 5.6-8.4 8TT92 7.0-10.0 4.00 5.50 TT93 8.4-11.9 8TT93 10-13 5.50 7.50 TT94 11.4-16.0 8TT94 13-18 9.00 12.5 Spares and Accessories Replacement coils and spare contactors are available, including a 110V coil option. Replacement Contactor Coils Coil Voltage 50Hz To Suit Contactor To Suit Starter New Catalogue No. 110V 2818VCO or 4818 VCO 28ADS1X or 48ADS1X 8COIL118 220-240V 2818VCO 28ADS1X 8COIL218 380-415V 4818VCO 48ADS1X 8COIL418 Contactors The new contactor design complies with latest requirements of BS EN 60947-4-1:2001 (Specification for low-voltage switchgear and controlgear. Contactors and motor-starters. Electromechanical contactors and motor-starters) and the international standard IEC 60947-4- 1:2002. Contactors are rated for AC3 duty and tested for 15 million mechanical and 1.5 million electrical operations. Replacement Contactor Coil Voltage 50Hz kw HP Amps (AC3) New Catalogue No. 220-240V 9 12.5 18 2818VCO 380-415V 9 12.5 18 4818VCO

Easy Six Stage Installation Process ADS8 Quick and Easy Installation ADS8 has been designed with the installer in mind. Quick and Easy to install, the improved aesthetics are just one of the attractions of the ADS8 Motor Starter. Step 1 Removal of Contactor Assembly On removal of the enclosure lid, the Contactor / Relay assembly can be withdrawn by loosening the 2 fixing screws located top left and bottom right of the mounting plate. Step 2 Gland Entry Selection Selecting any of the removable gland entry positions, remove the appropriate knockouts suitable for cable entry. Step 3 Cable Preparation Once the empty enclosure is fastened to the wall, feed through cable tails as appropriate ensuring the unit is earthed. Step 4 Internal Wiring Connect the pre-prepared cable tails to the Contactor and Relay as per the wiring diagram illustration and secure connections. Step 5 Fastening of Pre-wired assembly On completion of wiring, the Contactor / Relay assembly can be re-fitted into the enclosure and the 2 fixing screws tightened. Step 6 Fitting of Main Cover Ensure all cables are neatly routed, refit enclosure lid and tighten outer screws.

Overall dimensions Fixing and knockout positions Impact-resistant, rust-protected sheet steel enclosure with two-tone grey powder coated finish. IP54 environmental protection against dust and splashing. Clear green start button and mushroom-headed STOP button. Substantial terminal block and excellent earth continuity. Knockouts in top, bottom, sides and back, in positions identical to ADS7 range. The offset position of the contactor leaves generous space for wiring. Circuit Diagrams A. Three Phase Motors-D.O.L. Starter. Local 3-Wire (Push Button) Control. B. Single Phase Motors-D.O.L. Starter. Local 3-Wire (Push Button) Control. Local & remote 3-Wire (Push Button) Control Connect as above except remove lead X and add connections shown. Note: You cannot and should not, mix and match ADS7 components with the ADS8.

Eaton Electric Limited Reddings Lane Birmingham B11 3EZ www.eatonelectrical.co.uk Customer Support Centre Tel: 08700 545 333 Fax: 08700 540 333 ukcommorders@eaton.com 2005 Eaton Corporation Partial or complete reproduction is granted with written permission of Eaton Electrical. Printed in UK. Publication No. TD03406001U August 2005