Model 201 Wiegand Touchpad Reader Installation Guide



Similar documents
Model 940 Proximity Reader. Installation Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

Universal Vehicle Power Supply 9007AX01. Installation Instructions

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

EMBEDDED ACCESS CONTROL Hardware Installation Guide

LMU Hardware and Installation Guide

PCS300 Universal IP Reporting Module V1.0

VARIO PROX CARD READER INSTALLATION MANUAL

Control Box Wiring For PRSstandard Tool

Vehicle Power Install Kit

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AXIS T81B22 DC 30W Midspan

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Modular I/O System Analog and Digital Interface Modules

IEI 232e Standalone TM Keypad Installation/ Programming Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Shunt lock function 3066

WIRELESS STATUS MONITOR

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Fire Fighter Phone System Installation Instructions

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

DIY QUAD. Build Manual V.A 2014

MCR1900 Media Converter 19-Slot Chassis

Troubleshooting and Diagnostics

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

±15 V Current-Limited Power Supply

Part Name/Description Part Number Quantity. Power Cable

INSTALLATION INSTRUCTIONS

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

WIRELESS READER INTERFACE - INDOOR

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Digital Keypad Use s Manual

BrightSign Expander Hardware Guide

UniStream CPU-for-Panel

Color Mark Sensor with Red or Green LED E3S-VS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

Advantium 2 Plus Alarm

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

GV- RK1352 Card Reader

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual


CoolWave r 2 Phase Control Board and Cable Replacement Kits

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Hardware Installation Guide

PART 1 - INTRODUCTION...

Your Multimeter. The Arduino Uno 10/1/2012. Using Your Arduino, Breadboard and Multimeter. EAS 199A Fall Work in teams of two!

Name: Bicycle Cellphone Charger Circuit Assembly Manual Device: Nokia/Blackberry List of Components:

Provides one channel for Ethernet over existing

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

LocoNet, the Digitrax Difference

DIY Y6. Build Manual V.A 2014

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

ViZion Installation Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Assembly Instructions: Shortwave Radio Kit

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

AutoRanging Digital MultiMeter

NC-12 Modbus Application

PUSH BUTTON START INSTALLATION MANUAL

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

3M Wrist Strap and Footwear Tester 740. User s Guide

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Mobile Data Power Model: MDP-25

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Single Station Remote Alarm

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

PagePac PAGEPAL V

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Digi-Motor Installation Guide

AR-721U/721K/661U User s Guide

HMI display Installation Guide

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide


SYSTEM 4C. C R H Electronics Design

ATL Fuel Level Sender Probes

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Square D Clipsal C-Bus Network Analyzer

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

Adaptability to Enhanced Security

Lab 3 - DC Circuits and Ohm s Law

INSTALLATION MANUAL XM3 Reader

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Kit Watt Audio Amplifier

UniPi technical documentation REV 1.1

Transcription:

Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11

2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from UTC Fire & Security, except where specifically permitted under US and international copyright law. WARNING: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Content Introduction 3 Product Features 3 Installation Overview 4 Connecting the Reader 5 Pinouts 5 Wiring Diagrams 5 Installing the Amp Card 8 Mounting the Reader 10 Testing the Reader 12 Troubleshooting Guide 13 Technical Specifications 14 Functional Specifications 15 Contacting technical support 16 2 Model 201 Wiegand Touchpad Reader Installation Guide

Introduction This manual is an installation guide for the Model 201 Wiegand Touchpad Reader. It combines a Wiegand reader and a touchpad in the same housing. The Model 201 uses Wiegand technology and features an 8-bit touchpad. It is designed to mount on a standard U.S. gang box. Both card and touchpad data are transmitted over the Wiegand lines, eliminating the need to pull separate wiring for each device. Product Features The UTC Fire & Security Model 201 Wiegand Touchpad Reader offers: Sealed, rugged, weather resistant housing for indoor or outdoor use Ability to read Wiegand badges 5V operation Clear, logical user interface with two LEDs Touchpad for Personal Identification Number (PIN) input Model 201 Wiegand Touchpad Reader Installation Guide 3

Installation Overview The following is a recommended sequence of steps for installing and setting up the reader. 1. Connect the reader as detailed in Connecting the Reader on page 5. 2. If the cabling distance for the reader is greater than 100 feet, install the amp card. See Installing the Amp Card on page 8 for more details. 3. Mount the reader. Refer to Mounting the Reader on page 10. 4. Test the reader. This process is detailed in Testing the Reader on page 12. 5. If necessary, refer to the Troubleshooting Guide on page 13. 4 Model 201 Wiegand Touchpad Reader Installation Guide

Connecting the Reader Pinouts The table below shows the pinouts for connecting the reader to the microcontroller. Table 1: Pinouts Signal Pigtail wire color +5 VDC Red Ground Black Data 0 Green Data 1 White LED Control Brown Hold Line NOT USED Blue Case Ground Tan Wiring Diagrams See the wiring diagram that follows for details on connecting the reader to the microcontroller. For distances less than 100 feet, see Figure 1 on page 6. For distances greater than 100 feet, you will need to use an amp card. See Installing the Amp Card on page 8 for more information on using an amp card.. Model 201 Wiegand Touchpad Reader Installation Guide 5

Figure 1: Wiring Diagram, Model 201 Wiegand Touchpad 6 Model 201 Wiegand Touchpad Reader Installation Guide

Notes: Unless otherwise specified: 1. For Micro/2/4/5 only: a 470-ohm, 1/2W, pull-up resistor is required between +5V DC, READER DATA 0 and READER DATA 1. The pull-up resistors should be installed at the microcontroller s terminal block. Resistors are supplied with the reader. 2. Shielded cable is recommended in electrically noisy environments. 3. If using shielded cable, connect all shields together at the micro end. Connect to ground stud in the lower left corner of Micro/2/4/5 cabinets using 14-AWG wire. No shield connections at the reader. 4. If using a local power supply, do not connect +5V line from the microcontroller to the reader. However, the negative side of the power supply must be connected to the micro (pin 2 on the reader port). Keep the wiring from power supply to reader less than 50 feet. 5. Switching the external indicator drives to GND activates the indicator. High impedance or +5V de-activates indicators. These drives may also be connected to user supplied, external indicating circuitry. 6. Refer to the appropriate system manual to determine whether this connection is required for door switch operation. 7. Blocking diodes may be 1N4148 or similar, supplied by the installer and located in a secured area. 8. Protection diodes may be 1N4002, 1N4003, or 1N4004 (installer supplied) for the door strike assembly. 9. Fuse, power supply, door strike, and relay are provided by the installer. Model 201 Wiegand Touchpad Reader Installation Guide 7

Installing the Amp Card 1. Decide where you are going to mount the amplifier card. It should be mounted in the ceiling on the secure side of the door or in another secure location within 100 feet of the reader. Observe the maximum cabling distances listed below: Device Micro to Amp Card Amp Card to Reader Distance 1000 feet (305 meters) 100 feet (30.5 meters) 2. Each amp card is shipped with a gray plastic snap track. Carefully slide the amp card from the snap track. Drill one hole to secure the snap track then slide the amp card back onto the snap track. If the customer has supplied a 4 inch x 4 inch (10.2 cm x 10.2 cm) box to be used instead of a snap track, drill the appropriate holes in the wall or above the ceiling materials for mounting on the secure side of the door. 3. Prepare and run the reader and door lock cables. Drill a hole in the wall for threading the reader and door lock cables. Thread both cables through the wall leaving 10-inch (25 cm) leads. 4. Connect the reader cable and door strike cable to the amp card. There is no need to remove the 13-pin connector from the amp card while securing the reader cabling wires in the terminal slots. The connector must remain oriented on the amp card in the same direction as when the card was shipped. The connector fits only one way on the amplifier card. 5. Jumper the amp card to 1 and 4. 6. Connect the wires from the 13-pin connector on the amp card to the connector on the 2RP or the 2SRP board in the micro, as shown in the figure on the following page. 8 Model 201 Wiegand Touchpad Reader Installation Guide

Figure 2: Wiring Diagram, Model 201 Wiegand Touchpad with Amp Card Model 201 Wiegand Touchpad Reader Installation Guide 9

Mounting the Reader The reader comes with a backplate suitable for mounting directly onto standard U.S. electrical gang boxes. The reader may also be mounted directly onto a hollow wall. Refer to the appropriate figure for the type of mounting you are using. Figure 3: Mounting Template. Figure 4: Model 201 Reader - Gang Box Mounting. Figure 3: Mounting Template 10 Model 201 Wiegand Touchpad Reader Installation Guide

Figure 4: Model 201 Reader - Gang Box Mounting Model 201 Wiegand Touchpad Reader Installation Guide 11

Testing the Reader Follow the steps below to verify that the reader is working correctly. 1. Check all cabling and electrical connections from the reader to the microcontroller. Refer to the wiring diagram on page 4. 2. Verify that the microcontroller is properly configured. Refer to the appropriate UTC Fire & Security microcontroller manual. 3. Apply power to the reader, and verify that the red LED is on. You may want to use a multimeter to test the voltage at the reader s pigtail, using ground (black) as a reference. The power pin (red), data lines (green and white), and door DO (brown) should all read approximately 5V. 4. Select a known good test badge. Be sure the badge is properly entered in the host system, and the micro badge data format matches the reader. If the reader is used with the touchpad, assign a proper PIN. 5. Check that the door is secure. Present the badge to the reader. 6. If the reader is used with the touchpad, enter a PIN. Refer to the host manual for instructions on entering the PIN. Observe that the green LED turns on indicating a valid access has been granted by the host. 7. Open the door. This verifies that the door strike operates correctly. 12 Model 201 Wiegand Touchpad Reader Installation Guide

Troubleshooting Guide If the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against wiring diagrams before powering up the system. None of the LEDs are on: Check the power supply. It should read between 4.5 and 5.5V DC. The green LED is always on: The green LED indicates that the door strike is open. It is controlled by the input on the brown wire. 1. Disconnect the brown wire. If the green LED stays on, the reader is faulty and should be replaced. If the green LED goes off, then the problem is most likely not in the reader. 2. Reconnect the brown wire and measure its voltage. Low voltage turns on the green LED. If the voltage is low, check to see if the host system is turning on the door strike. The door does not open and the green LED does not turn on when a badge is presented: 1. Verify the badge and reader are properly entered into the system. 2. Verify that the door strike and the green LED are wired correctly. Since the green LED and the door strike are separate indicators, this problem is not an indication of a defective reader. The green LED does not turn on, but the door strike unlocks the door when a valid badge is presented: 1. Verify that the door DO is wired correctly. Refer to the appropriate wiring diagram. 2. Disconnect the brown wire (green LED) and connect it to the black wire (ground). If the green LED is now on, the reader is good and the connection to the reader is defective. If the green LED does not turn on, replace the reader. Model 201 Wiegand Touchpad Reader Installation Guide 13

Green LED turns on but the door does not open: Verify correct door strike wiring and operation. The reader is functioning properly. Technical Specifications Operating Temperature Range: -40 C to +70 C (-40 F to 160 F) Operating Humidity: 10 to 95% Index of Protection: IP52 Physical Dimensions: 5.64 inches (H) x 4.27 inches (W) x 2.25 inches (D) 143 mm (H) x 109 mm (W) x 57 mm (D) Slot Width: 0.0624 inches to 0.069 inches 1.6 mm to1.75 mm Maximum Cabling Distance: A six-conductor shielded 18AWG cable is recommended. The maximum cable distance between the reader and the microcontroller should not exceed 100 feet. Distances over 100 feet require amplifier P/N 110044001. Power Supply: 5V DC, 120mA typical, 150mA maximum Color: Black Pinouts: The reader is supplied with a seven wire pigtail. 14 Model 201 Wiegand Touchpad Reader Installation Guide

Functional Specifications Application: Intended for areas requiring a moderately high level of security for controlled access. The touchpad can be used for low security applications, the Wiegand reader for high security applications, and both for maximum security. Compatibility: Interfaces to Entry Perfect, Picture Perfect and Secure Perfect software systems. Only the Micro/5-E, Micro/5-PX and Micro/5- PXN running either a 2RP or a 2SRP supports this reader. The Micro/5-E firmware version must be at the following levels for these packages: Entry Perfect must be at 2.14 or higher Secure Perfect 1.2 must be at 1.2.3 or higher Secure Perfect 2.0 must be at 2.0.1 or higher Reader Technology Type: Wiegand technology Badge Formats: Wiegand data format For Use With Code Strip Layout Options: A long edge/right side A1 long edge/left side D short edge PIN Format: The maximum allowed PIN entry is 65,534. PIN Entry: The * key is used to clear the touchpad for entry of a PIN. For the touchpad to accept the PIN, press the # key after entering the 5-digit PIN. (For example, if entering the PIN 12345, enter the following: *12345#) Mounting: The reader can be mounted directly onto a standard U.S. electrical single gang box. The reader can also be mounted directly onto a hollow wall. See Mounting the Reader on page 8 for additional details. Indicators: Red and green LEDs are incorporated into the reader. Red LED: Normally on when power is applied to the reader. Green LED: Indicates microcontroller has activated the door strike. Touchpad Operation: The reader sends each new keypress to the microcontroller. Model 201 Wiegand Touchpad Reader Installation Guide 15

Contacting technical support For assistance installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, you may contact technical support during normal business hours (Monday through Friday, excluding holidays, between 8 a.m. and 7 p.m. Eastern Time). Note: Be ready at the equipment before calling for technical support. North America T 888 437 3287 F 561 998 6224 Asia T 65 639 19314 F 65 639 19306 Australia T 61 3 9239 1200 F 61 3 9239 1299 Canada T 800 267 6317 F 613 737 5517 EMEA T 48 58 326 22 40 F 48 58 326 22 41 Latin America T 503 691 7294 F 561 994 6572 Email: rs-bctsupport@fs.utc.com Web site: www.utcfireandsecurity.com 16 Model 201 Wiegand Touchpad Reader Installation Guide