Spool Center Condition * Orifice Closed Open 2-Position Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize



Similar documents
Directional Control Valves

KDG3V-5/7/8, 10 Series

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves

Directional Controls

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

3 Port Solenoid Valve

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Chapter 6: Check Valves

Pressure Relief Valves for Pipe Mounting

Oil Pressure Regulating Valve

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

DIRECTIONAL CONTROL VALVES

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

3/2- and 2/2-way cartridge valve type BVE

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

SOLENOID VALVES 3-4 WAY

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

3 Port Solenoid Valve

Directional seated valves type VP 1

2/2 and 3/2 Way Size 6 Seat Valves

Chapter 5: Flow Valves

Variable Displacement Pump AA10VSO

005 SERIES MODULAR VALVES. Pub. EC General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type

4 Posiflow Proportional Solenoid Valves

3/2 Solenoid Cartridge Valve, Size 6

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Pressure Relief. Pressure Relief Valves. Vickers

Electro-pneumatic control valves

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Single sub-base valve

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

mpm DIN CONNECTORS

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Ref.nr.: Oud-Beijerland Willem Beukelszstraat LV Oud-Beijerland Nederland Telefoon: +31(0)

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Line-Mounted Valves L Series

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

3/2-way Solenoid Valve, direct-acting, NC or NO

Valves. Sub-Base Mounted Valves to ISO 5599/2

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Assisted lift operated 2/2-way solenoid valves Type EV250B

Electro-hydraulic pressure switches type DG

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

Load-sensing control block in mono and sandwich plate design

Series PVP Variable Volume Piston Pumps

5 Port Solenoid Valve

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Centro-Matic Automatic Lubrication Systems System Controls

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2-way flow control valve Type 2FRM 6

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

AZ420 MINIATURE GENERAL PURPOSE RELAY

SystemStak. SystemStak Valves. Vickers

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

ATL Fuel Level Sender Probes

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

Unit 24: Applications of Pneumatics and Hydraulics

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

3/2-way Mini Solenoid Valve

Pressure transmitter For general industrial applications Model A-10

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

System 8. ü ( System 8

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Scraper Passage Indicator. Electrical Indicator. Features

VSO MAX HP High Flow Proportional Valve

Speed Control Relays SX2

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Pressure reducing valve, direct operated, Type ZDR 6 D

Manual motor starter MS116

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Open center control block in monoblock design MO-40

Transcription:

echnical Information General directional control valves are high performance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Features Soft shift available. 21 standard spool styles available. roportional spools. DC surge suppression. Nine electrical connection options. C & DC lights available (CS approval for solenoids and lights). Internally ground. Easy access mounting bolts. Waterproof (meets NEM 4, up to I67 on some models). Eplosion proof. CS approvals. Specifications Mounting attern NF D03, CEO 3; NG 6 Mounting DIN 24340-6 Interface ISO 4401--03-4- CEO R35H 4.2-4-03, NF D03 Maimum,, ressure 345 ar (5000 SI) Standard CS 276 ar (4000 SI) ank: 103 ar (1500 SI) C only 207 ar (3000 SI) DC/C Rectified Standard C Optional CS 103 ar (1500 SI) U.L. recognized available - Contact Division. No tools required for coil removal. C rectified coils. Leakage Rates* Maimum llowable: 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @ 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per Minute/Land @ 207 ar (3000 SI)* *#008 and #009 ypical: Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @ eceed these rates. 69 ar (1000 SI)* Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @ 345 ar (5000 SI) Response ime Response time (milliseconds) at 345 ar (5000 SI) is 32 LM (8.5 GM). Solenoid ype ull-in Drop-Out C 13 20 DC 8 Watt 61 22 or 10 Watt DC 30 Watt 51 21 2502-1.p65, dd 15 Spool Center Condition * Orifice Closed Open 2-osition Soft Shift Size Voltage Energize De-Energize Energize De-Energize Energize De-Energize S2 0.020 S3 0.030 S4 0.040 S5 0.050 C 175 ms 700 ms 600 ms 800 ms 150 ms 200 ms DC 200 ms 650 ms 700ms 650 ms 175 ms 225 ms C 150 ms 400 ms 500 ms 600 ms 100 ms 150 ms DC 125 ms 325 ms 550 ms 550 ms 100 ms 100 ms C 125 ms 300 ms 450 ms 500 ms 100 ms 100 ms DC 100 ms 250 ms 500 ms 450 ms 75 ms 60 ms C 100 ms 250 ms 400 ms 450 ms 50 ms 100 ms DC 50 ms 225 ms 400 ms 400 ms 50 ms 40 ms * Step response times were obtained under the following conditions: 100 SSU fluid @ 120 F with the valve operating at nominal pressure and flow. ublished response times are nominal and may vary with spool, flow, pressure and temperature. arker Hannifin Corporation Elyria, Ohio, US

Ordering Information Series D1V Standard Valves D Directional Control Valve 1V asic Valve ctuator Spool Style Seal Solenoid Voltage 2502-1.p65, dd NF D03 CEO 3 DIN NG6 Symbol Symbol 001 014 002 015 003 016 004 020* 005 021 006 022 007 026* 008*, 030** 009** 010 081 011 082 W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spool have open crossover. See Universal Spool Chart for other spool options. old: Designates ier I products and options. N Nitrile V Fluorocarbon E* ER Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D Double solenoid, 2 position, detent. E Single solenoid, 2 position, spring centered. to and to when energized. F Single solenoid, 2 position. Spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K * Contact HVD for availability. Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * 020, 026 and 030 spools only. 020 and 030 spools only. High Watt only. Non-old: Designates ier II products and options. hese products will have longer lead times. ** D G J K L N*** *** Q** QD R U Y Z b 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC 220/50 VC 110/50 VC 100/60 VC 100/60-100/50 VC 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC ** High Watt only *** Eplosion roof only. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a springcentered valve eists when both coils are deenergized, or during a complete shift, as the spool passes through center. b b b b a a a a a 16 arker Hannifin Corporation Elyria, Ohio, US

Ordering Information Series D1V Standard Valves C Solenoid Connection Conduit o D Metric lug (M12X1), DESIN E* Eplosion roof G J * lug-in Conduit o Deutsch (D06-2S) M * Metri-ack (150) S * DIN with lug Double Spade W* DIN w/o lug * Not available with lights. DC only. Coil Options ube Options Options Electrical Options Omit Shift Response and Indication Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice I7** I8** Monitor Switch Direct Op. End Stroke Monitor Switch Direct Op. Start Stroke * Not available with 8 watt, must have DC tube. **, E, H & K styles only. Spools 8,9,21,26,81,82 not available. Not CE or CS approved. pprovals Valve Design Variations Series NOE: Not required when ordering. Omit D E F** High Watt Eplosion roof, EEXD EX Eplosion roof, EEXME EX Low Watt C CS Hazardous Location L*** O U Valve Weight: Single Solenoid Double Solenoid Standard olt Kit: Metric olt Kit: 8 Watt Eplosion roof, MSH Eplosion roof, UL/CS X* No Coils * See solenoid voltage code to specify proper tube. ** C only. *** DC and C Rectified only. pplicable to conduit bo and plug-in style only. 1.36 kg (3.0 lbs.) 1.6 kg (3.5 lbs.) K209 KM209 Omit Omit Standard * Etended with oot * No W* Waterproof rotection * override options not available on eplosion proof or soft shift. Low ressure, C only 103.5 ar (1500 SI) H* High ressure, C only 207 ar (3000 SI) G Omit J** Standard ressure, DC/C Rectified 207 ar (3000 SI) * Not available with CS. No Options Diode Surge Suppressor Rectified Coil DC tube standard. ** Not applicable with DIN plug with lights. Omit Standard Valve 3* CS US (UL429) 4* CS Canada * Not available with C high pressure tube., C, H styles only. J, K, Y, U voltages only. C, G, W sol. connections only. 5 Signal Lights 6 Manaplug - rad Harrison Mini 7 Manaplug - rad Harrison (121) Micro 56 Manaplug (Mini) with Lights 7 1 1 1C 1D 1M Manaplug (Micro) with Lights Manaplug (Mini) Single Sol. 5-pin Manaplug (Micro) Single Sol. 5-pin Manaplug (Mini) Single Sol. 5-pin, with Lights Manplug (Micro) Single Sol. 5-pin, with Lights Manaplug Opposite of Normal 4D wist & Lock (Old 5426) 4E ush (Old 5450) 4F 1 Heavy Duty Detent ainted ody DC/C Rectified only. Not available with soft shift. 2502-1.p65, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 17 arker Hannifin Corporation Elyria, Ohio, US

Catalog HY14-2502/US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -10% to +15% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Eplosion roof Solenoid Ratings* UL & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the NEC MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Ed, Group II; EN50014: 1999+ mds. 1 & 2, EN50018: 2000 CS Hazardous Location Class II, Div 1 & 2, Groups E, F & G * llowable Voltage Deviation ±10%. Note that Eplosion roof C coils are single frequency only. Voltage ower Voltage In Rush mps mperage In Rush mps D1VW V @ 3MM Holding mps D1VW Watts D1VW Resistance D1VW 24/50 VC, High Watt 7.00 mps 168 V 2.65 mps 28 W 1.67 ohms D L 120 VDC N/ N/ 0.09 mps 10 W 1584.00 ohms N/ N/ 0.26 mps 30 W 528.00 ohms G L 198 VDC N/ N/ 0.05 mps 10 W 3920.40 ohms N/ N/ 0.15 mps 30 W 1306.80 ohms J L 24 VDC N/ N/ 0.44 mps 10 W 51.89 ohms N/ N/ 1.32 mps 30 W 17.27 ohms K L 12 VDC N/ N/ 0.88 mps 10 W 12.97 ohms N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms N/ N/ 5.00 mps 30 W 1.20 ohms Q 100 VC / 60 Hz 1.7 pms 170 V 0.56 mps 24 W 26.0 ohms QD 100 VC / 60 Hz 0.41 mps 135 V 0.41 mps 18 W 31.2 ohms QD 100 VC / 50 Hz 0.57 mps 150 V 0.57 mps 24 W 31.2 ohms R 24/60 VC, High Watt 8.00 mps 192 V 2.70 mps 27 W 1.40 ohms F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms 240/60 VC, High Watt 0.77 mps 185 V 0.26 mps 25 W 134.50 ohms 220/50 VC, High Watt 0.82 mps 180 V 0.31 mps 27 W 134.50 ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W 145.00 ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W 145.00 ohms U L 98 VDC N/ N/ 0.10 mps 10 W 960.00 ohms Y 120/60 VC, High Watt 1.55 mps 186 V 0.49 mps 25 W 33.70 ohms 110/50 VC, High Watt 1.65 mps 182 V 0.58 mps 27 W 33.70 ohms F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W 36.50 ohms F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W 36.50 ohms Z L 250 VDC N/ N/ 0.04 mps 10 W 6875.00 ohms N/ N/ 0.13 mps 30 W 1889.64 ohms Eplosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W 33.50 ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W 34.70 ohms Q 100/60 VC 1.90 mps 192 V 0.70 mps 27 W 38.60 ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W 17.33 ohms D 120 VDC N/ N/ 0.28 mps 33 W 420.92 ohms Z 250 VDC N/ N/ 0.13 mps 33 W 1952.66 ohms 2502-1.p65, dd 18 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in o, Double DC Solenoid 44.9 (1.77) 87.8 (3.46) 143.7 (5.66) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a springcentered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. 54.3 Min. Coil (2.14) Removal 1/2 NF hd. oth Ends 49.6 (1.95) 24.8 (0.98) 66.0 (2.60) 93.2 (3.67) 244.4 (9.62) lug-in o, Single DC Solenoid 44.9 (1.77) 87.8 (3.46) 1/2 NF hd. oth Ends 49.6 (1.95) 24.8 (0.98) 54.3 (2.14) Min. Coil Removal 188.5 (7.42) 66.0 (2.60) 93.2 (3.67) 2502-1.p65, dd 19 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double DC Solenoid 12.0 (0.47) Min. Connector Removal 72.6 (2.86) 115.4 (4.54) 142.1 (5.59) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. 54.3 (2.14) Min. Coil Removal 25.3 (1.00) 23.0 (0.91) 66.3 (2.61) 77.6 (3.06) 244.4 (9.62) Hirschmann, Single DC Solenoid 23.0 (0.91) 25.3 (1.00) 54.3 (2.14) Min. Coil Removal 100.8 (3.97) 72.6 (2.86) 12.0 (0.47) Min. Conn. Removal 77.6 (3.06) 66.3 (2.61) 168.3 (6.63) 2502-1.p65, dd 20 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Double C Solenoid 36.8 (1.45) 126.8 (5.00) 79.9 (3.15) 42.75 (1.68) Min. Coil Removal Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. ½ NF hread oth Ends 49.5 (1.95) 24.8 (0.98) 3.0 (0.19) See Note 66.0 (2.60) 94.6 (3.72) 210.7 (8.30) Conduit o, Single C Solenoid 42.75 (1.68) Min. Coil Removal 84.0 (3.31) 36.8 (1.45) ½ NF hread oth Ends 49.5 (1.95) 24.8 (0.98) 3.0 (0.19) 66.0 (2.60) 94.6 (3.72) 163.7 (6.44) 2502-1.p65, dd 21 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Double C Solenoid with Variation 6 (Manaplug) & Variation (Etended ) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. 36.8 (1.45) 126.8 (4.99) 95.7 (3.77) 42.8 (1.69) Min. Coil Removal Connector NF 3.5.29 25.4 (1.00) He 49.5 (1.95) 3.0 (0.19) 24.8 (0.98) Etended 66.0 (2.60) 94.6 (3.72) Solenoid Reverse Sides for # 8 & 9 Spool 61.2 (2.41) Minimum Coil Removal 225.0 (8.86) Solenoid Reverse Sides for # 8 & 9 Spool Conduit o, Double DC & C Rectified Solenoids with Variation 6 (Manaplug) & Variation (Etended ) Etended 36.8 (1.45) 79.9 (3.15) 95.7 (3.77) 142.1 (5.59) 54.3 (2.14) Min. Coil Removal Connector per NF 3.5.29 25.4 (1.00) He 66.0 (2.60) 3.0 (0.19) 49.5 (1.95) 24.8 (0.98) 94.6 (3.72) 2502-1.p65, dd 72.7 (2.86) Min. Coil Removal 255.4 (10.01) 22 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Deutsch Double DC Solenoid Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. 92.7 (3.65) 142.1 (5.59) 54.25 Min. Coil Removal 20.0 (0.79) 5.66 (0.22) 2.83 (0.11) 23.0 (0.91) 54.2 (2.13) 65.5 (2.58) 244.4 (9.62) Deutsch Single DC Solenoid 92.7 (3.65) 142.1 (5.59) 54.25 Min. Coil Removal 20.0 (0.79) 5.66 (0.22) 2.83 (0.11) 23.0 (0.91) 54.2 (2.13) 65.5 (2.58) 168.3 (6.63) 2502-1.p65, dd 23 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DESIN, Double DC Solenoid Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. Light 48.0 (1.89) 90.7 (3.57) 142.1 (5.59) 54.3 (2.14) Min. Coil Removal 70.3 (2.77) 50.8 (2.00) 242.4 (9.54) DESIN, Single DC Solenoid Light 90.7 (3.57) 142.1 (5.59) 543 (2.14) Min. Coil Removal 70.3 (2.77) 50.8 (2.00) 167.3 (6.59) 2502-1.p65, dd 24 arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Eplosion roof U.L. & C.S.., Double Solenoid 60.4 (2.38) 163.7 (6.44) 18 Inch Lead Wires Standard 1/2" N 94.4 (3.72) 130.8 (5.15) 304.4 (11.98) Eplosion roof M.S.H.., Double Solenoid 73.0 (2.87) 15.1 7.5 (0.30) 3/4-20 UNF hd. 60.4 (2.38) 163.7 (6.44) 3/4-20 UNF hd. 38.0 (1.50) 113.0 (4.45) 130.8 (5.15) 304.4 (6.44) Eplosion roof EX, Double Solenoid 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) M20 1.5-6H hd. Ground Stud with Lockwasher 73.0 (2.87) 1 7.5 (0.30) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. 100.9 (3.97) 42.8 (1.69) 131.7 (5.19) 100.6 (3.96) 2502-1.p65, dd 7.5 (0.30) 73.5 (2.89) 141.0 (5.55) 25 324.7 (12.78) arker Hannifin Corporation Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit o, Single DC Solenoid with Variation I7 (Monitor Switch) & Variation (Etended ) 72.7 (2.86) Min.Coil Removal 115.1 (4.53) 12.0 (0.47) Min. Conn. Removal 3.0 (0.12) 49.5 (1.95) 24.8 (0.98) Etended 274.9 (10.82) 81.9 (3.22) 70.6 (2.78) 94.6 (3.72) Monitor Switch (valve variation I7 and I8) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring +18-42 volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. lock Diagram Inductor Regulator (Etended, or Energized osition) in 2 (Input 24VDC) in 1 (Output Normally Open) in 3 (Output Normally Closed) in 4 (Ground erminal) For repetitive switch power-up conditions, please consult factory. 2502-1.p65, dd 26 arker Hannifin Corporation Elyria, Ohio, US

ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid Solenoid (ositive) Wire #1 (Red/White) Solenoid (Negative) Wire #5 (Red/lack) Solenoid (Negative) Wire #2 (Red) Solenoid (ositive) Wire #4 (Red/Yellow) Ground Wire #3 (Green) 5-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid Double Solenoid Valves Installed Over Solenoid ( and Solenoids Reversed for #8 and #9 Spools) ins are as seen on valve (male pin connectors). Conduit o (Standard/lug-In; Option G) Meets Nema 4/I67 Signal Lights (Option 5) LED Interface Hirschmann lug with Lights (Option 5) ISO 4400/DIN 43650 Form 2502-1.p65, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) 27 DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors). 1 4 2 DESIN design in 1 and 2 connected 5 3 arker Hannifin Corporation Elyria, Ohio, US 1 2 3 4 5

ccessories Series D1V Mounting olt Kits olt Kits for use with D1V & Manapaks (D1V*-82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated) Number of Manapaks at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Manapaks/Cartpaks @40mm (1.58") thickness 0 1 2 3 4 K209 1.25 in. K243 2.88 in. K225 4.38 in. K244 6.00 in. K245 7.50 in. KM209 30 mm KM243 70 mm KM225 110 mm KM244 150 mm KM245 190 mm K246 3.00 in. K247 4.62 in. K248 6.12 in. K249 7.75 in. KM246 75 mm KM247 115 mm KM248 155 mm KM249 195 mm K250 4.75 in. K251 6.38 in. K252 7.88 in. KM250 120 mm KM251 160 mm KM252 200 mm K253 6.50 in. K254 8.12 in. KM102 170 mm KM254 205 mm K103 8.25 in. KM103 210 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Eplosion roof Coils & Manapaks (D1V*-82 & 70/75 Design) Number of Manapaks at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Manapaks/Cartpaks @40mm (1.58") thickness 0 1 2 3 4 K50 2.00 in. K211 3.63 in. K101 5.12 in. K102 6.75 in. K103 8.25 in. KM50 50 mm KM101 130 mm KM102 170 mm KM103 210 mm K51 3.75 in. K212 5.37 in. K105 6.87 in. K106 7.75 in. KM51 95 mm KM107 180 mm KM106 195 mm K52 5.50 in. K213 7.13 in. K108 8.62 in. KM52 140 mm KM108 220 mm K53 7.25 in. K214 8.87 in. KM53 185 mm K54 9.00 in. KM54 230 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Manapak valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58") thickness. For additional technical information about Manapak valves, refer to the Manapak Sandwich Valve Section of this Catalog. 7.0 (0.28) 14.5 (0.57) 45.0 (1.77) 2502-1.p65, dd 36 arker Hannifin Corporation Elyria, Ohio, US

Closed Crossover Open Crossover Symmetrical Standard Catalog HY14-2502/US Universal Spool Chart Series D1V 001 002 003 004 005 006 007 008 009 010 011 012 014 015 016 020 020D 020H 021 022 023 026 026H 030 030D 030H 031 032 033 034 035 038 039 042 043 043H 044 047 Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool Symbol D1V* D1V* D3*W D31DW D41 D41*W D61VW D81/D91 D101VW D111 D1V*: Double Double Spool 0 D1VW: /C// D31*DW/ Monitor HCD Monitor HVD HCD HVD HCD Number D1VHW D/G/L D31DW Switch Switch HVD = HCD = Hydraulic Controls Division Gray = available White = not available Spools shown may be nonstandard. lease contact HVD for availability. 2502-1.p65, dd 38 arker Hannifin Corporation Elyria, Ohio, US

Closed Crossover Open Crossover Symmetrical Standard Catalog HY14-2502/US Universal Spool Chart Series D1V Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool: Spool Symbol D1V* D1V* D3*W D31DW D41 D41*W D61VW D81/D91 D101VW D111 D1V*: Double Double Spool 0 D1VW: /C// D31*DW/ Monitor HCD Monitor HVD HCD HVD HCD Number D1VHW D/G/L D31DW Switch Switch 049 049H 051 054 055 056 058 059 061 062 066 067 068 068H 069 069H 070 070H 071 071H 073 076 078 079 080 081 081 081H 082 083 083H 084 085 098 099 100 101 Gray = available White = not available HVD = HCD = Hydraulic Controls Division Spools shown may be nonstandard. lease contact HVD for availability. 2502-1.p65, dd 39 arker Hannifin Corporation Elyria, Ohio, US

Installation Information Series D1V Fluid Recommendations remium quality hydraulic oil with a viscosity range between 32-54 cst. (150-250 SSU) at 38 C (100 F) is recommended. he absolute operation viscosity range is from 16-220 cst. (80-1000 SSU). Oil should have maimum anti-wear properties and rust and oidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, FLUOROCRON seals are required. Waterglycol, (95/5) water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -29 C to +71 C (-20 F to +160 F) Filtration For maimum valve and system component life, the system should be protected at a contamination level not to eceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unepected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are epected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Flow ath Data D1V Operator Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve eists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition eists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approimately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs). 2502-1.p65, dd 40 arker Hannifin Corporation Elyria, Ohio, US