Installation Instructions



Similar documents
GB/DAS User Instruction

Article: Version:

Installation Guide. DEVIreg 530. Electronic Thermostat.

DEVIreg 330 (+5 to +45 C)

The original heating cable just got better

ACS-30-EU-EMDR-10-MOD

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

User Manual THR840DUK Digital Thermostat

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Drayton Digistat +2RF/+3RF

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Operating Instructions

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

Single Channel Loop Detector

PD 100A. Printing data system

Infrarot-Bewegungsmelder IP44

2013 Wireless Video Intercom INSTALLATION GUIDE

Operating instructions IV / 2007

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

GSM Alarm System User Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

DLP-PU/E Instruction Manual

HERZ-Thermal Actuators

Stove Guard Kit User Manual

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Inwall Room Temperature Unit

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

ABB i-bus KNX Fan Coil Controller FC/S 1.1

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Operation and Installation Manual

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Operating Instructions

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

LED Security Spotlight User Manual

Niko Home Control. Installation Manual

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

TC-9102 Series Surface Mount Temperature Controllers

Product and Application Description

Wireless 7 Day Programmable Room Thermostat

Installation and maintenance instructions. Danfoss Vent

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

LK Electric Boiler - 4,5

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Dual Laser InfraRed (IR) Thermometer with Color Alert

MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Operating instructions II / 2004

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

INFRARED QUARTZ WALL HEATER

B/S/H/ Error codes and service programmes PH

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Power Socket (2 Gang)

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

SOLAR POWER - THE NEW WAY TO RV!

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

TIG INVERTER INSTRUCTION MANUAL

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Assisted lift operated 2/2-way solenoid valves Type EV250B

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Portable Air Conditioner

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

MP-4000 Alarm List (Software version or later)

PAC1 Door Access Controller

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

DALI RC BASIC SO. Control unit Operating instructions

Transcription:

GB-DAS Installation Instructions devireg 850 ground or roof systems (1-4 sensors) 1

Contents: 1. Installation instructions - ground systems................... 1.a. Placing the ground sensor(s)........................... 1.b. Installing feeder cable(s)............................... 1.c. Installing sensor(s)/sensor tube(s)........................ 1.d. System description.................................. 2. Installation instructions - roof systems...................... 2.a. Placing the roof sensor(s).............................. 2.b. Installing feeder cable(s)............................... 2.c. Installing sensor(s)................................... 2.d. System description.................................. 3. Connection diagrams & setup of devireg 850................ 4. User guidelines & navigation structure...................... 5. Technical specifications & factory settings................... 6. Warranty conditions & warranty certificate................... NB! The installation must only be carried out by an authorised electrician. A disconnection must be incorporated in the fixed wiring to ensure all-pole disconnection from the supply mains. Appendix A: System configuration - PSU & feeder cable Appendix B: Output per m 2 3

1. Installation instructions (ground) The devireg 850 system is used to keep outdoor areas free of ice and snow, e.g. parking areas, paths, garage entrances, steps, ramps, roadways, bridges. The devireg 850 is fully automatic and operated digitally by means of the intelligent sensors located in the heated terrain. Every sensor measures both temperature and moisture, and the system turns the heating elements on and off on the basis of these readings. By combining moisture and temperature readings, the system is able to save around 75% energy compared with systems which only measure temperature readings. The digital sensors used for the devireg 850 also provide the most exact readings when compared with corresponding analogue systems. The result is optimum functionality and low energy consumption. 1.a. Placing the ground sensor(s) Correct placing of the sensor(s) is important for the system to work as intended. Some basic guidelines: The number of ground sensors: 1) The more sensors you add to your system the better the performance. 2) The basic principle is to place one sensor where the snow/ice will appear first (for fast detection) and one sensor where the snow/ice will disappear last (for complete melting). If it is not obvious just place the sensors as far apart from each other as possible. 3) With only one sensor you will have to decide what is most important: a) fast detection and activation of the system or b) securing a complete melting of all snow/ice. Sensor Sensor 4

A one sensor ground system will be less fast regarding detection and activation than a two sensor ground system, where one sensor measures the ground temperature and the other sensor measures the moist. 4) With more than two sensors it is possible to cover problem spots where snow usually is not detected or where snow is not completely melted when the system stops. Sensor Sensor min.1 m Sensor Placing the individual ground sensor: 1) The sensor must be placed within the heated area and at least 1 m from the edge of the area, if possible. 2) The sensor must be placed in between the heating cables - a distance of minimum 1 cm should be maintained between the sensor tube and the heating cable. 3) There must be a distance of minimum 1 m between the two sensors. min. 1 cm min. 1 m Assembly box Feeder cable 5

1.b. Installing a feeder cable(s) A feeder cable for a sensor may be needed. A 15-meter cable is supplied with each sensor. Approx. 0.5 m of this cable should be coiled inside the bottom of the sensor tube. The remaining cable may be lengthened in accordance with the following table. The feeder cable must be a four wire cable. See appendix A: system configuration - PSU & feeder cable. 1.c. Installing a sensor and a tube The sensor and the tube may be installed in connection with the actual construction work and connected at a later date. The following applies for all types of installations: 1: Please ensure that the tube is sealed when the concrete is poured. 2: The tube must be positioned so that it is flush with the surrounding terrain. The sensor must be placed so that the upper brass surface is horizontal. 3: The base below the tube must be hard, e.g. a concrete plate or similar, in order to ensure that the sensor is not pushed into the ground if e.g. a lorry runs over it. The tube is designed to be mounted on a plate using the two screw holes inside the tube. 6

4: A metal/plastic pipe, through which the sensor cable may be passed, should be run as far as the sensor tube. installation pipe 5: Coil approx. 0.5 m of the sensor cable inside the tube. 6: Place the sensor inside the tube until it is horizontally flush with the edge of the tube and "resting" on the internal collar inside the tube. The sensor may be extracted at a later date using the two holes found around the edge of the sensor tube. The grooves on the outside of the sensor should correspond with the holes in the tube. installation pipe with sensor cable Installation in asphalt: The temperature must not exceed 80 C around the sensor/ tube. A wooden block or similar may be placed in the area where the tube/sensor can be placed subsequently. The installation pipe used for the sensor cable should, in that case, be a metal tube that can withstand the high temperatures. 7

1.d. System description The devireg 850 functions on the basis of a combination of temperature and moisture. The temperature and the moisture are registered by the sensor(s) placed in the area. You must be aware of the following conditions if you choose to adjust the factory settings. Melting temperature Changing the melting temperature will affect when the system is activated in case of moisture and low temperatures. The factory setting is 4 C. This means that the heating system will be activated if the temperature falls below 4 C and moisture is detected. Standby temperature (maintained ground temperature) The higher the standby temperature the faster the system will be able to melt ice and snow. On the other hand the higher the standby temperature the higher the running costs. So, determining the standby temperature is a trade-off between fast melting or low running costs. The factory setting is -3 C. Moisture level The "moisture level" decides when the system detects moist. The lower the setting, the more sensitive the system is to moisture. The factory setting is 50. Post-heat It is possible to modify the post-heat period, i.e. the period during which the heating system continues to be active once it has detected that the area is dry. The factory setting is 1 hour. 8

High security higher energy consumption If a high degree of security against ice and snow is wanted, adjust the settings of the parameters: the standby temperature and the melting temperature should be higher and the moisture level lower (close to setting 5). Finally, you should prolong the post-heat period. This will give a high degree of security in even dry areas. Low security lower energy consumption Conversely, low energy consumption and a moderate level of security against ice and snow could be prioritised. In this case the standby temperature and the melting temperature should be lower and the moisture level higher. Finally, you should shorten the post-heat period. This will give a relatively low energy consumption, but the area may remain wet and icy in short periods. The factory settings are average values providing a relatively high degree of security and a moderate energy consumption. See appendix B: Output pr. m 2 9

2. Installation instructions (roof) The devireg 850 roof system is used for frost protection in roof gutters, valley gutters and down pipes; and to prevent icicles from causing damage. The system also can be used to reduce/ remove the snow weight from the roof. The devireg 850 is fully automatic and operated digitally by means of the intelligent sensor(s). The sensor(s) measures both temperature and moisture, and the system turns the heating elements on and off based on these readings. By combining moisture and temperature readings, the system is able to save around 75% energy compared with systems which only measure temperature readings. The digital sensor used for the devireg 850 also provides the most exact readings when compared with corresponding analogue systems. The result is optimum efficiency and low energy consumption. 2.a. Placing the roof sensor(s) Correct placing of the sensor(s) is important for the system to work as intended. Some basic guidelines: The number of roof sensors: 1) The more sensors you add to your system the better the performance. 2) The basic principle is to place one sensor where the snow/ice will appear first (for fast detection) and one sensor where the snow/ice will disappear last (for complete melting). If it is not obvious just place the sensors as far apart from each other as possible. 3) With more than two sensors it is also possible to cover problem spots where snow usually is not detected or where snow is not completely melted when the system stops. 10 Roof system Roof gutter Down pipe Sensor devireg 850

Placing the individual roof sensor: 1) The sensor should be installed in the heated surroundings most often in the roof gutter, but it could also be installed on the roof in special applications. 2) The sensor should be located where the first water and snow is expected to hit the roof/ gutter. Make sure the sensor is placed in an open environment, and is not covered by trees, other buildings, shadows etc., and preferably where ice and snow usually cause the most problems. 3) There is no general recommendation for placing a sensor with regards to direction (N, S, E, W). Based on experience the most likely position is in the North (North/West) roof gutter. 2.b. Installing a feeder cable A feeder cable for a sensor may be needed. A 15-meter of cable is supplied with the sensor. This may be lengthened in accordance with the following table. (The feeder cable must be a four-wire cable). See appendix A: System configuration - PSU & feeder cable. 2.c. Installing sensor(s) min. 1 cm A sensor should be placed between or next to the heating cables. Note, however, that a distance of minimum 1 cm should be maintained between a sensor and the heating cable. A sensor must be placed so that the upper brass surface is horizontal. To withhold a sensor in the right position there are different ways to mount it. Either use the attachments on the sensor or glue it to the surface or simply place it in the roof gutter. The attachments can be removed when not used. 11

2.d. System description The devireg 850 functions on the basis of a combination of temperature and moisture. Be aware of the following conditions if other basic settings are chosen. Melting temperature Changing the melting temperature will affect when the system is activated in case of moisture and low temperatures. The factory setting is 1.5 C. This means that the heating system will be activated if the temperature falls below 1.5 C and moisture is detected. Moisture level The moisture level decides when the system detects moist or no moist. The lower the setting, the more sensitive the system is to moisture. The factory setting is 50. Post-heat The post-heat period indicates the period during which the heating system continues to be active once the sensor has detected that the roof/gutter is dry and free of ice and snow. The factory setting is 1 hour. High security higher energy consumption If a high degree of security against ice and snow is wanted, adjust the settings of the parameters: the standby temperature and the melting temperature should be higher and the moisture level lower (close to setting 5). Finally, you should prolong the post-heat period. This will give a high degree of security in even dry areas. Low security lower energy consumption Conversely, low energy consumption and a moderate level of security against ice and snow could be prioritised. In this case the standby temperature and the melting temperature should be lower and the moisture level higher. Finally, you should shorten the post-heat period. This will give a relatively low energy consumption, but the area may remain wet and icy in short periods. The factory settings are average values providing a relatively high degree of security and a moderate energy consumption. See appendix B: Output pr. m 2 12

3. Connection diagrams for ground or roof Mount the devireg 850 and the transformer on a DIN rail and connect the transformer as well as the sensor(s) to the devireg 850 (see Fig. A). Next, connect the heating element to the devireg 850 in line with one of the following guidelines (Fig. B-G): A Wiring diagram RS232 (for software upgrades) DC supply - + The devireg 850 has an integral alarm function 24V that monitors the attached sensors and the inbuilt microprocessor. An external alarm may also be connected to the system. Roof Ground 13

B - 230V, 1-3 P/1-3 loads - ground C -230V, 1-3 P/1-3 loads - roof K1 K1! 230V cables! 230V cables If the sensors are connected before the devireg 850 is turned on they will appear in random order. Setup of devireg 850 The following will be required when turning on the devireg 850: 1. Select language 2. Select system (ground or roof) 3. Connect/add sensor(s) 4. Confirm the number of sensors when ALL sensors (ground or roof) have been connected. In case of irresolvable problems due to a wrong choice of language etc.: Master reset: press & for 8 seconds. 14

D - 400 V, 2-3 Phase/1-3 Loads - ground E - 400 V, 2-3 Phase/1-3 Loads - roof! 400V cables F - Direct connection - ground! 400V cables G - Direct connection - roof! 230V cables! 230V cables 15

4. User guidelines The devireg 850 is controlled by means of three buttons. Info button only active when lit Next menu/next line Enter: Confirm/select Navigation structure 1. Start screen. 2. View and set operation mode: a. Automatic b. Constant on (0-99 hours) c. Constant off 3. View sensor measurements: a. Temp. b. Moist. 4. View system parameters: a. Moisture level b. Standby temperature c. Melting temperature d. Postheat 5. View alarm menu. 16

6. Installer site: a. Set moisture level (5-95) b. Set standby temp. - ground only (-20 C to 0 C) c. Set melting temp. (1.0 C to 9.9 C) d. Set postheat (0 to 9 hours) e. Clogged drain - on/off (an alarm gets activated after 14 days constantly heating) f. View statistics - operating time - running time - relay operations -... g. Change system (ground or roof/number of sensors) h. Set language i. Restore factory settings The devireg has an integral alarm function (flash & sound) which monitors the sensors added and the built in microprocesser. When activated please see the alarm menu. An external alarm can also be added to the system. 17

5. Technical Specifications Technical data Voltage: 230 VAC +10%/-20% Power consumption: devireg 850: Max. 3 W Sensor(s): ground: max. 13W, roof: max. 8W Relays (all incl. alarm): Resistive load: 250V ~ 16A Inductive load: 1A (power factor 0,3) IP class: devireg 850: IP 20 Sensors: IP 67 Ambient temperature: devireg 850: -10 C to +40 C Sensor - ground: -30 C to +70 C Sensor - roof: -50 C to +70 C Sensor type: devibus connected moisture sensor(s) Sensor lead: 15 m of 4x1mm 2 (may be extended in accordance with the table in appendix A) Indication: 2 x 16-character illuminated display. Measurements Depth x Height x Width devireg 850 (DIN rail) 53 mm x 86 mm x 105 mm Sensor - ground D = 87 mm; height = 74 mm Sensor tube - ground D = 93 mm; height = 98 mm Sensor - roof 15 mm x 23,5 mm x 216 mm 18

Factory settings - ground Settings Function Factory settings Options Moisture level 50 5 to 95 (5 being the most sensitive to moisture) Standby temperature -3.0 C -20 C to 0 C Melting temperature 4.0 C 1.0 C to 9.9 C Post-heat 1 hour 0 to 9 hours Clogged drain On On/off System mode Automatic Automatic Constant ON (manual timer) Manually OFF Factory settings - roof Settings Function Factory settings Options Moisture level 50 5 to 95 (5 being the most sensitive to moisture) Melting temperature 1.5 C 0.0 C to 9.9 C Post-heat 1 hour 0 to 9 hours Clogged drain On On/off System mode Automatic Automatic Constant ON (manual timer) Manually OFF 19

The DEVI Warranty: You have purchased a DEVI heating system which we are sure will serve to improve the comfort and economy of your home. DEVI provides a complete heating solution with deviflex heating cables or devimat heating mats, devireg thermostats and devifast fixing strips. Should you, against all expectations, experience a problem with your DEVI heating system, you will find that DEVI, whose products are manufactured in Denmark and sold throughout the European Union, is subject to the standard regulations pertaining to product liability as specified in EU directive 85/374/CEE as well as all applicable legislation in the individual countries on the following conditions: DEVI offers a 10-year guarantee on all deviflex heating cables and devimat heating mats, and a 2-year guarantee against material defects and production defects in connection with any other DEVI products. The guarantee shall be valid only if the GUARANTEE CERTIFICATE is completed correctly and in accordance with the instructions, and provided the fault is inspected by or submitted to DEVI or an authorised DEVI dealer. DEVI shall undertake any repair free of charge or supply the customer with a new unit. Repairs shall be carried out at no further cost to the customer. In the case of faulty devireg thermostats, DEVI reserves the right to repair the unit free of charge and without any unreasonable delays for the customer. The DEVI Guarantee shall not cover installations that have been carried out by non-authorised electricians, faults which arise as a result of misuse by other suppliers, damage caused by third parties, incorrect installations or consequential damage. All work will be invoiced in full if DEVI is required to inspect or repair faults that have arisen as a result of any of the above. The DEVI Guarantee shall not extend to equipment which has not been paid in full. DEVI will, at all times, provide a rapid, effective and honest response to all queries and reasonable demands from our customers. The above guarantee covers product liability only, while purchases are subject to national legislation. Please note that the GUARANTEE CERTIFICATE must be completed in english or local language. 20

Name: Warranty Certificate The DEVI Warranty is granted to: Address: Postal code: Phone: Please Observe! In order to obtain the DEVI Warranty, the following must be carefully filled in. See other conditions on the overleaf Electrical installation by: Installation date: Type of thermostat: Production code: Supplier s stamp DEVI A/S Ulvehavevej 61 DK-7100 Vejle Tel. +45 76 42 47 00 Fax +45 76 42 47 03 www.devi.com 21 08095245-01.01

Appendix A: System configuration - PSU & feeder cable 1 pcs. PSU 18V dc, 16W Ground system Roof system Number of sensors: 1 or 2* 1 Cable type Max. length (m) Max. length (m) 1 mm 2 65 100 1.5 mm 2 100 150 2.5 mm 2 165 250 4 mm 2 265 400 Ground system 1 pcs. PSU 24V dc, 24W 2 pcs. PSU 24V, 24W in parallel Number of sensors: 1 or 2* 3 4 Cable type Max. length (m) Max. length (m) Max. length (m) 1 mm 2 300 150 80 1.5 mm 2 450 225 120 2.5 mm 2 750 380 200 4 mm 2 1200 600 310 Roof system 1 pcs. PSU 24V dc, 24W 2 pcs. PSU 24V, 24W in parallel Number of sensors: 1 2 3 4 Cable type Max. length (m) Max. length (m) Max. length (m) Max. length (m) 1 mm 2 400 100 130 75 1.5 mm 2 600 150 200 110 2.5 mm 2 1000 250 330 190 4 mm 2 1600 400 525 300 22

Appendix B: Output per m 2 Typical installed ratings for ground and floor applications are shown in the table below. Area of use Choice of rating Normal Maximum (Denmark) (Russia) Car parks 250-300 W/m 2 300 W/m 2 Driveways 250-300 W/m 2 300 W/m 2 Pavements 250-300 W/m 2 300 W/m 2 Stairs 300-375 W/m 2 400 W/m 2 Loading platforms 300-375 W/m 2 400 W/m 2 Bridges 300-375 W/m 2 400 W/m 2 Roof, tiles, metal 250-300 W/m 2 300 W/m 2 Roof, tar paper 150-300 W/m 2 300 W/m 2 Cold roof Roof gutter/down pipe Metal 30-40 W/m 50 W/m Plastic 30-40 W/m 50 W/m Wood 30-40 W/m 40 W/m Hot roof Roof gutter/down pipe Metal 40-50 W/m 50 W/m Plastic 40-50 W/m 50 W/m Wood 40 W/m 40 W/m See the compendium for further information. (www.devi.com). 23