Fire Sprinkler Monitoring PRODUCTS. Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof



Similar documents
How To Control Water Flow

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Potter Electric Sprinkler Monitoring Training Manual

Fire Sprinkler Monitoring & Releasing Systems

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Fire Alarm System Monitoring - CAN/ULC-S561-03

Release Control Fire Alarm Systems

Module 5. Fire and Emergency Alarm System Part I- Basics

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Technical Data. Installation

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FIRE ALARM SYSTEM RECORD OF COMPLETION

We look forward to working with you. Worldwide Headquarters 1400 Pennbrook Parkway Lansdale, PA

FIVE YEAR CERTIFICATION REPORT

FIRE ALARM SYSTEM RECORD OF COMPLETION

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Fire & Security DETECTORS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

Centro-Matic Automatic Lubrication Systems System Controls

Fire Alarm System Plans Review Checklist Property location Date of Review

Residential & Commercial Alarm Systems by Gross Security, LLC

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

BERMAD Fire Protection

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Sprinkler and Fire Alarm Systems for the Building Official

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

D287/D288/D292/D293A/D293E

City of Bettendorf Fire Alarm System Requirements

Control/Communicator Installation Manual

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

BASIC FIRE ALARM TRAINING

EXHIBIT A SCOPE OF WORK

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

Security with you in mind. As your needs change, NetworX security systems grow with you.

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

DUCT SMOKE DETECTOR D4120

C. Conform to requirements of Americans with Disabilities Act (ADA).

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Security with you in mind. As your needs change, NetworX security systems grow with you.

Automatic Fire Sprinkler Submittal Requirements

Solution Ultima ICP-CC488 Home security you can rely on

NetworX. Security with you in mind. As your needs change, NetworX security systems grow with you.

How To Install A Carbon Monoxide Detector

rpsa FIRE PROTECTION ENGINEERS

PLAN REVIEW GUIDE FOR FIRE ALARM

BERMAD Fire Protection

Solution Ultima ICP-CC488 Home security you can rely on

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

Sanitary Type Electronic Flow Switches

SECTION DETECTION AND ALARM

The Benefits of ADDRESSABLE Fire Alarm Technology

Bold items are particular to the City of Euless

SECTION FIRE ALARM AND DETECTION SYSTEMS

NetworX. Security with you in mind. As your needs change, NetworX security systems grow with you.

Second Revision No. 106-NFPA [ Global Comment ] Supplemental Information. Submitter Information Verification. Committee Statement

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

CHAPTER 9 FIRE PROTECTION SYSTEMS

Expansion Modules & Accessories

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

FIRE-FIGHTING DESIGN BRIEF REPORT

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

FIRE ALARM SYSTEM Section Page 1

Medical Air Systems: Scroll

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

INSTALLATION INSTRUCTIONS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Appendix B Forms for Inspection, Testing, and Maintenance

FIRE ALARM AND DETECTION SYSTEMS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

PRODUCT PROFILE FEATURES

Operating Instructions

Potter Plus. Fire Alarm Control Panels

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

SMART SENSOR COLLECTION

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Transcription:

Fire Sprinkler Monitoring PRODUCTS Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof

2

Fire Sprinkler Monitoring Products During a fire condition, sprinkler system reliability is critical, whether it s the operation of a sprinkler head or the monitoring of the sprinkler system itself. System Sensor s line of waterflow detectors, pressure switches, and supervisory switches provide that reliability when monitoring waterflow, system pressure, and valve position within a fire sprinkler system. Waterflow Monitoring Waterflow detectors are available in a variety of configurations and accommodate 2" through 8" pipe for commercial riser applications, as well as 1" NPT connections for residential or branch line signaling. The WFDN series detectors provide a mechanical time delay to help prevent false alarms due to water pressure surges or air trapped in the system. The time delay mechanism now includes an easy-to-rotate timer dial with high contrast pad printed markings to make setting the device easy. The terminal block is designed for easy wiring and the device cover is designed to be damage and shock resistant. Pressure Monitoring System Sensor s line of pressure switches includes the EPS10 series for use in wet, dry, deluge and pre-action automatic sprinkler systems to indicate a discharge from a sprinkler. The EPS40 and EPS120 series supervisory pressure switches are intended for dry pipe systems or pressure tanks and water supplies of automatic water control valves. These models offer a choice of initiating low or high/low pressure alarms, in a variety of pressure ranges. Valve Monitoring The nerve center of a fire sprinkler system is the valves that control the entire system. System Sensor offers a variety of choices for supervising system control valves. Regardless of valve type (outside screw and yoke, post indicator, butterfly, or non-rising stem gate valve), our OSY2, PIBV2, and PSP1 models provide you with the peace of mind that comes from knowing that your system s control valves are being monitored. System Alarms Completing the System Sensor line of sprinkler monitoring products are the PDRP-2001 control panel and SSV/SSM series alarm bells. Our reliable system provides a way to detect and respond to changes on all initiating and release circuits, reducing the risk of loss from fire. Combined with our alarm bells, these devices make it easy to signal any change in your fire sprinkler system. Explosion-Proof To complement our line of fire sprinkler monitoring products, we offer a full line of Explosion- Proof devices intended for use in hazardous locations where volatile vapors or particulates may be present. Our Explosion-Proof product offering includes 2 through 8 waterflow detectors; EPS10, EPS40, and EPS120 pressure switches; and OSY2 and PIBV2 supervisory switches. systemsensor.com/sprinkler 3

How can you be sure your system will operate when needed? The National Fire Protection Association (NFPA) records indicate Sprinklers save lives and protect property from fires. Compared to properties without automatic extinguishing equipment, the death rate per fire in sprinklered homes is 83 percent lower. Direct property damage per fire in sprinklered homes is 73 percent lower. The question then becomes: How can you be sure that your system will operate when needed? System Sensor Sprinkler Monitoring Devices System Sensor products supervise sprinkler systems by monitoring waterflow, valve positions, and system pressure to ensure system reliability and effectiveness. When it comes to installing the very best, always specify System Sensor fire sprinkler monitoring devices. Our engineered products help keep people and property safe. The Power Behind the Products Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology. System Sensor develops products for real-world applications worldwide. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor places a premium on research and development to provide the most reliable, innovative, and comprehensive line of products in the industry. Code Requirements When installing and maintaining a fire sprinkler system, be familiar with NFPA requirements: NFPA 13: Standard for the Installation of Sprinkler Systems NFPA 13D: Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes NFPA 13R: Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems NFPA 72: National Fire Alarm Code NFPA 101: Life Safety Code 4

Fire Sprinkler Monitoring NEW! WFDN Series Waterflow Detectors The WFDN Series detectors provide an easy to see, feel, and set time delay mechanism. The timer dial is large and easy to turn, with high contrast pad-printed markings. Set by feel in dimly lit locations with tactile features for approximate setting at 30 and 60 seconds. The delay/switch assembly is field replaceable for ease of maintenance. WFDN Series Waterflow Detectors Pipe Size Hole Size Pressure Rating Contact Ratings WFD20N 2 in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD25N 2½ in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD30N 3 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD40N 4 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD50N 5 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD60N 6 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD80N 8 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; Triggering Threshold NEW! T-TAP Series Waterflow Detectors The T-Tap Series Waterflow detectors are designed for residential and branch-line signaling; all have a NEMA 4 rating. Two versions are available one with a built-in time delay and one with instant activation. T-Tap Series Waterflow Detectors Compatible Tee Fittings Time Delay Pressure Rating Contact Ratings Triggering Threshold See, feel, and set timer dial WFDTN 1 in. NPT branch, including: 1in., 1¼in., 1½ in. and 2in. NPT threaded ferrous and brass tees; 1in., 1¼in., 1½in. and 2in. copper sweat tees; Tyco, Spears, NIBBCO brand 1 in. CPVC tees Adjustable 0 to 90 seconds 375 PSI 2 Form C: 10 A @ 125/250 VAC, 2.5 A 24 VDC The new timer dial has high-contrast lettering and tactile markings. Now you can set the timer by sight or touch with repeatable precision: a must when detectors are installed in hard-to-reach or dark spaces. WFDTNRN 1 in. NPT branch, including: 1in., 1¼in., 1½ in. and 2in. NPT threaded ferrous and brass tees; 1in., 1¼in., 1½in. and 2in. copper sweat tees; Tyco, Spears, NIBBCO brand 1 in. CPVC tees Instant activation 375 PSI 2 Form C: 10 A @ 125/250 VAC, 2.5 A 24 VDC systemsensor.com/sprinkler 5

Fire Sprinkler Monitoring Transition from WFD Series to WFDN Series Waterflow Detectors Convert to the fully redesigned WFDN Series Waterflow Detector offering, including the T-Tap Series, designed to meet the needs of today s fire sprinkler professional. See the cross-reference chart below. WFD to WFDN Series Conversion NEW Description WFD20 WFD20N 2" Waterflow Detector WFD25 WFD25N 2.5" Waterflow Detector WFD30-2 WFD30N 3" Waterflow Detector WFD40 WFD40N 4" Waterflow Detector WFD50 WFD50N 5" Waterflow Detector WFD60 WFD60N 6" Waterflow Detector WFD80 WFD80N 8" Waterflow Detector WFDT WFDTN T-Tap Waterflow Detector for use with 1" NPT WFDTH WFDTN T-Tap Waterflow Detector for use with 1" NPT WFDTNR WFDTNRN T-Tap Waterflow Detector for use with 1" NPT, without time delay Supervisory Switches System Sensor manufactures devices for supervising a variety of control valves, including outside screw and yoke, post indicator, butterfly, and rising and non-rising stem gate. Supervisory Switches Description Valve Size Contact Rating OSY2 Used to monitor the open position of an outside screw-and-yoke type gate valve 1 in. to 12 in. 10 A @ 125/250 VAC; Operating Current PIBV2 Used to monitor the open position of post indicator and butterfly control valves 10 A @ 125/250 VAC; PSP1 A plug-in special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used Plug Contacts: 250 ma @ 6/12/24 VAC/DC, normally open Cover Tamper: 5 A @ 125/250 VAC, 2.5 A @ 6/12/24 VAC 250 ma EPS Series Pressure Switches The EPS Series pressure switches are offered in three varieties and with one or two SPDT contacts. The EPS10 alarm pressure switches are ideal for dry pipe systems, while the EPS40 and EPS120 supervisory pressure switches are intended for supervising air pressure in pipes or pressure tanks. EPS Series Pressure Switches EPS10-1 EPS10-2 Operating Pressure Adjustment Range Differential Contact Rating 300 psi 4 to 20 psi 3 psi 10 A, ½ HP @ 125/250 VAC; Threaded Connection reinforced nylon EPS40-1 EPS40-2 300 psi 10 to 100 psi 3 psi @ 10 psi and 6 psi @ 100 psi 10 A, ½ HP @ 125/250 VAC; reinforced nylon EPS120-1 EPS120-2 300 psi 10 to 200 psi 3 psi @ 10 psi and 9 psi @ 200 psi 10 A, ½ HP @ 125/250 VAC; reinforced nylon 6

Fire Sprinkler Monitoring Explosion-Proof Waterflow Detectors & Switches System Sensor s full line of explosion-proof products are intended for use in hazardous locations where volatile vapors or particulates may be present. System Sensor offers a complete line of explosion-proof waterflow detectors, supervisory switches, and alarm and supervisory pressure switches. WFD Series Explosion-Proof Waterflow Detectors Hazardous Location Classification: Class I, Groups B, C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2; Class III, Division 1 & 2 Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD20EXP 2 in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD25EXP 2½ in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD30-2EXP 3 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD40EXP 4 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD50EXP 5 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD60EXP 6 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; WFD80EXP 8 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; Explosion-Proof Supervisory Switches Hazardous Location Classification: Class I, Groups B, C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2 Description Valve Size Contact Rating OSY2EXP PIBV2EXP Explosion-proof supervisory switch used to monitor the open position of an outside screw-and-yoke type gate valve Explosion-proof supervisory switch used to monitor the open position of post indicator and butterfly control valves 1 in. to 12 in. 10 A @ 125/250 VAC; 10 A @ 125/250 VAC; Explosion-Proof Pressure Switches Hazardous Location Classification: Class I, Groups B, C, D, Division 1 & 2; Class II, Groups E, F, G, Division 1 & 2; Class III, Division 1 & 2 Operating Pressure Adjustment Range Differential Contact Rating EPS10EXP 250 psi 4 to 20 psi 3 psi 10 A, ½ HP @ 125/250 VAC; Threaded Connection brass fitting EPS40EXP 250 psi 10 to 100 psi 3 psi @ 10 psi and 6 psi @ 100 psi EPS120EXP 250 psi 10 to 200 psi 3 psi @ 10 psi and 9 psi @ 200 psi 10 A, ½ HP @ 125/250 VAC; 10 A, ½ HP @ 125/250 VAC; brass fitting brass fitting Alarm Bells & Notification The alarm bells offer high-output notification in security and fire alarm systems. Six-inch, eight-inch, and ten-inch models are available for 24 VDC and 120 VAC systems. Alarm Bells Gong Size Nominal Voltage Operating Voltage Sound Output Current SSM24-6 6 in. 24 VDC 16 33 VDC 82 db DC 31.1 ma / FWR 53.5 ma SSM24-8 8 in. 24 VDC 16 33 VDC 80 db DC 31.1 ma / FWR 53.5 ma SSM24-10 10 in. 24 VDC 16 33 VDC 81 db DC 31.1 ma / FWR 53.5 ma SSV120-6 6 in. 120 VAC 96 132 VAC 85 db 53 ma SSV120-8 8 in. 120 VAC 96 132 VAC 82 db 53 ma SSV120-10 10 in. 120 VAC 96 132 VAC 82 db 53 ma Notification PDRP-2001 P2RHK-120 Description Deluge Pre-action Control Panel: Up to 6 Class A/B initiating zones, up to 4 Class A/B NAC, 100% programmable relays, 80 character LCD display, and a 256 event history SpectrAlert Advance Outdoor Wall-Mount Horn Strobe; Red with FIRE marking, High Candela, 2-Wire, Clear Lens, 120 V systemsensor.com/sprinkler 7

Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology. System Sensor develops products for real-world applications worldwide. With sales, service, and manufacturing facilities throughout the Americas, Europe, and Asia, System Sensor places a premium on research and development to provide the most reliable, innovative, and comprehensive line of products in the industry. www.systemsensor.com/sprinkler 2015 System Sensor. Product specifications subject to change without notice. WFBR50002 2/15