Tasarım ve Baskı: AJANSBRAND A 15.09.2014



Similar documents
PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS


Presentation of the France Transfo factories

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

SECTION DRY-TYPE TRANSFORMERS

Electrical Maintenance Workshop

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

Power Transformers Small, Medium & Large

Power transformers. Special transformers Railway

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

DRY TYPE TRANSFORMER

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Power Transformers 10 to 100 MVA

Multi-tap Transformers

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

TRANSFORMATORY DYSTRYBUCYJNE I MOCY POWER AND DISTRIBUTION TRANSFORMERS POL ENG

Oil and Coolant Circulating Heating System. Model - OCSM

Practical Transformers: Operation, Maintenance and Testing

This section applies to the design and installation of transformers.

ECOCIAT. Domestic hot water heat recovery unit

SECTION SUBSTATION TRANSFORMERS

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

SPECIFICATIONS OF STATCOM TRANSFORMER (FOR 2.5 MVAR STATCOM)

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

OLI. Oil level indicator

UNITED ARAB EMIRATES FEDERAL ELECTRICITY AND WATER AUTHORITY

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

An Overview of Lapp Insulator High Voltage Bushing Design

Low Voltage Transformers Sealed, General Purpose, Dry Type

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Distribution transformers. Green distribution transformer program Partnership for a sustainable environment

Fault location on power cables. Fault location on power cables

WINDING RESISTANCE TESTING

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Compact pressure switch Flameproof enclosure Ex d Model PCA

Distribution Voltage Regulators

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

understanding medium frequency induction melting furnace and its components

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Transformer Manufacturing Processes

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Material Name: - 8 MVA, 33/11KV POWER TRANSFORMER CONTENTS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Primary and Secondary Electrical Distribution Systems

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Transformer Design & Design Parameters

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

5800 Temperature Sensor Cable Assembly

James M. Pleasants Company

Transformer Bushings for GIS

3/2-way Solenoid Valve, direct-acting, NC or NO

ASME Packaged Indirect Fired Water Heater

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

OPERATING INSTRUCTIONS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

THE VALUE OF POWER FACTOR TESTING

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

INTERNATIONAL STANDARD

Diesel Engine Driven Generators Page 1 of 6

SELECTION, APPLICATION AND MAINTENANCE

SECTION HEAT PUMPS

TARIFF CODE and updates standard

جامعة البلقاء التطبيقية

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Failure code manual. content

TRANSFORMER FITTINGS & ACCESSORIES

Medical Air Systems: Scroll

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

CATHODIC PROTECTION SYSTEM DESIGN

Lightning Arresters P KVA P KVA. Description & Installation

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Screw Plug Immersion Heaters

Unit 24: Applications of Pneumatics and Hydraulics

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

FAQs-Main switchboard design criteria

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

RAY-MAX Integrated Solar Power Strip

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Transformer Deluge Systems

HP switch LP switch Discharge thermo Comp. Surface thermo

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Transcription:

www.kosgeb.gov.tr Tasarım ve Baskı: AJANSBRAND A 15.09.2014

THE ENERGY TRANSFERRED TO NATURE www.atstrafo.com

ABOUT Having been founded in Adıyaman Organized Industrial District in 2003, ATS Trafo carries out its manufacturing activities in its facilities with an indoor area of 2500 m² and an outdoor area of 000 m². ATS Trafo has been manufacturing tri-phase and mono-phase oil Distribution and Power Transformers up to a power of 2500 kva and an upper voltage of 3 kv as well as custom-made products according to the customer requirements. They include: Hermetic transformers, Cable-box transformers, Plug-in bushing transformers, Low-loss ( AoAk and other) transformers, Autotransformers, Earthing transformers, Furnace transformers, Rectifier transformers, On-load tap-changer transformers. ATS has been carrying on its transformer manufacturing activities with: Experienced personnel and quality equipment, High-quality materials, Optimum design and high efficiency, Short-time deliveries, Aftersales services 24/7, Design with regard to environmental protection, Continually developed project design, And an independent test laboratory. ATS trafo 3

www.atstrafo.com

TRANSFORMERS TRANSFORMERS WITH AN EXPANSION TANK: A transformer with an oil expansion tank is exposed to atmosphere and provides exchange of air through an air dryer (silica gel) container that prevents the moisture in air from passing into the transformer oil. The size of an expansion tank varies in proportion to the transformer power and size. HERMETIC TRANSFORMERS: Differently than with transformers with an oil expansion tank, hermetic transformers are completely sealed from the atmosphere (exterior milieu). In a hermetic transformer, the tank inside pressure building up due to oil expansion is counteracted by a flexible corrugated sheet metal sized as a result of calculations. In hermetic transformers, oil is filled at +20 C and sealed from atmosphere. SPECIAL TRANSFORMERS: Special transformers are manufactured for special areas of use in line with the client s requirements and requests except standard powers and voltages. Examples include grounding transformers, autotransformers, etc. ON LOAD TAP-CHANGER TRANSFORMERS: They are transformers capable of tap-changing under voltage and load, and power transformers are manufactured with this capability. With a system controlled by voltage regulators, the output voltage can be controlled manually or automatically to the required accuracy. CABLE-BOX TRANSFORMERS: Depending on the client s requests and specifications, transformers can be equipped with a cable box that provides protection against probable touches on areas under voltage (LV and HV terminals). Cable boxes can be designed so as to cover LV terminal or HV terminal or both LV and HV terminals. PLUG-IN BUSHING TRANSFORMERS: At the HV side of transformers, generally plug-in bushings manufactured from epoxy resin are used with a matched cable cap, instead of exposed porcelain insulators. Plug-in bushings are rather used for indoor transformers. ATS trafo 5 DISTRIBUTION & POWER TRANSFORMERS

www.atstrafo.com

PRODUCTION STAGES AND TECHNICAL FEATURES WINDINGS: In distribution and power transformers, windings are designed so as to provide maximum strength to axial and radial forces occurring during a short circuit. LV (low voltage) windings are generally from a foil or paper insulated flat conductor. HV (high voltage) windings are however an enamel insulated round wire conductor or a paper insulated round or flat conductor. Electrolytic copper or aluminium conductors are used. In between the layers of a coil, a special insulating material with increased insulation and high oil absorption is used, such as a craft paper, shellac paper (DDP, DPP) roll pressboards, etc. CORE: In transformers, the core consisting the magnetic circuit is made up from cold-rolled, grains-oriented (CRGO) and low-loss electrical silican steel. Core steel can be in varies thicknesses and qualities and are made up from high-quality silican steel such as M3, M4, M5, MOH, ZDKH85, ZDKH95 and Amorphous steel, depending on the client s requests, warranted iron loses (no load losses) and applicable specifications. Being highly sensitive, core sheets are trenched, cut to required lengths and arrayed. With hub steel, zero blurring is very important for iron losses. Additionally, step-lap, overlap, 45, 90, punctured or un-punctured hub sheets can be made by using different cutting and arraying techniques. Arrayed core steels are compressed by means of yoke compressing irons and studs to minimize iron losses and vibrations. ACTIVE PART: The active part of a transformer consists of the core, coils, upper cover, tap changer, bushings, and protection and connection members on the upper cover. When assembling the active part, the transformer must have a structure to provide the best strength against short-circuit mechanical forces. Therefore, strength stability is increased by additional measures during the construction of the active part. The active part is mounted on the upper cover of the boiler, using screws. Connections of the active part can be made on the upper cover or directly on side walls of the tank as well. ATS trafo 7

TANK: In tank manufacturing, the tank lower pan, side walls and the upper cover are made by using black sheet metal to quality St 37. Side surfaces that carry out the cooling function in transformers are made up from cooling members manufactured of 1,2 or 1,5 thick sheet metal, depending on the transformer s power, called corrugated wall panels. For bigger transformers (>2500 kva), radiators are used instead of corrugated wall panels. Every tank through with welding operations is subjected to oil-leakage test (pressure test). All surfaces of the tank to get in contact with oil are cleaned by sanding and special chemical cleaning methods for surface preparation prior to painting. DRYING AND OIL FILLING: The active part through with the assembly operation is dried in a special high-vacuum drying furnace for a period of time set forth within a predetermined program depending on power and voltage values, and placed in the tank. Then oil filling is done under vacuum. Since the drying operation takes away the moisture in the materials making up the active part, it is a very important process for the insulation of the transformer. PAINTING: Tanks complete with manufacturing are prepared by sanding and chemical cleaning methods prior to painting to ensure a longer lifetime for the applied primer and two final coats of paint. Tanks are painted with one coat of primer and two final coats of paint with a total thickness not less than 105 µ (microns). Although the RAL 7033 cement gray is used as a standard, non-standards are also used depending on the client s request. The primer and the paint of final coats are epoxy-based, double-component, acrylic substances and are selected from first-class materials that can endure working and environmental conditions for a long time. For painting, pouring and spraying methods are used. www.atstrafo.com

TRANSFORMER TESTS Routine tests are applied to all transformers through with manufacturing. Type tests and special tests are however conducted upon the client s request and depending on agreements. ROUTINE TESTS: Conversion ratio measurement and connection group determination, Measurement of winding resistances, Applied-voltage test, Induced-voltage test, Measurement of no load loss and current, Measurement of load loss and impedance voltage, Insulation resistance measurement, Core and body insulation checking test, Leakage test. TYPE TESTS: Temperature rise test, Lightning impulse voltage test, Measurement of audible noise level, Mechanical strength test against short circuits. SPECIAL TESTS: Capacity and insulation loss factor measurement (Double test), Insulation resistance measurement (Megger test), Transformer oil dielectric puncture strength measurement, Measurement of harmonics (No load current), Partial discharge test, Zero component impedance measurement. ATS trafo 9 DISTRIBUTION & POWER TRANSFORMERS

500-2500 kva DRAWINGS POS. DESCRIPTION 1 Oil Filling Plug 2 Conservator Oil Drain Nippel 3 Magnetic Oil Level Indicator 4 Earthing Terminals 5 H.V. Bushings L.V. Bushings 7 Wheels 8 Rating Plate 9 Oil Drain Valve 10 Lifting Lugs 11 Off - Load Tap Changer 12 Thermometer With Contact 13 Dehydrating Breather 14 Connection Box 500-2500 kva DRAWINGS POS. DESCRIPTION 1 Oil Filling Pipe 2 Pressure Safety Valve 3 Hermetic Protection Relay 4 Earthing Terminals 5 H.V. Bushings L.V. Bushings 7 Wheels 8 Rating Plate 9 Oil Drain Valve 10 Lifting Lugs 11 Off - Load Tap Changer 12 Lifting Jack Part 13 Arcing Horns 14 Terminal Box www.atstrafo.com

25-200 kva DRAWINGS POS. DESCRIPTION 1 Oil Filling Plug 2 Conservator Oil Drain Nippel 3 Magnetic Oil Level Indicator 4 Earthing Terminals 5 H.V. Bushings L.V. Bushings 7 Rating Plate 8 Oil Drain Valve 9 Lifting Lugs 10 Arcing Horns 11 Off - Load Tap Changer 12 Thermometer Pocket 25-400 kva DRAWINGS POS. DESCRIPTION 1 Oil Filling Pipe 2 Pressure Safety Valve 3 Oil Level Indicator 4 Earthing Terminals 5 H.V. Bushings L.V. Bushings 7 Wheels 8 Rating Plate 9 Oil Drain Valve 10 Lifting Lugs 11 Off - Load Lap Changer 12 Thermometer Pocket 250-400 kva DRAWINGS POS. DESCRIPTION 1 Oil Filling Plug 2 Conservator Oil Drain Nippel 3 Magnetic Oil Level Indicator 4 Earthing Terminals 5 H.V. Bushings L.V. Bushings 7 Wheels 8 Rating Plate 9 NW 22 Oil Drain Valve 10 Lifting Lugs 11 Off - Load Tap Changer 12 Thermometer 13 Dehydrating Breather 14 Pressure Relief Valve ATS trafo 11

TRANSFORMER ACCESSORIES Transformer accessories are protective and indicative equipment that are used depending on the transformer power and type. PRESSURE RELIEF VALVE: A pressure relief valve protects the transformer tank by ensuring the evacuation of sudden pressure rise building up in hermetic transformers in cases of failure. The valve is set to a certain values of pressure and can be selected with or without a contact. BUCHHOLZ RELAY: Buchholz relays are used in transformers with an oil expansion tank. It provides protection by giving contact in cases of electrical failures occurring in the transformer or caused by insulating materials. It has two contacts, warning and tripping, for cases of failure. www.atstrafo.com

DEHYDRATING BREATHER: In transformers with an oil expansion tank, an dehydrating breather mounted on the expansion tank prevents the moisture from penetrating oil by cutting off the direct interaction of oil with the exterior milieu by means of a silica gel put in it. The quantity of silicagel varies depending on the transformer power. HERMETIC PROTECTION RELAY: A hermetic protection relay is a multifunctional protective device that provides protection against temperature rise, pressure rise, low oil level and gas accumulation in hermetic transformers. A relay has two contacts, warning and tripping, against each failure condition. WITH CONTACT THERMOMETER: A contact thermometer has two contacts that are settable according to the permissible oil temperature rise in the transformer. It is possible to monitor oil temperature in the range of 0 to 120 C on the thermometer. YAĞ SEVİYE GÖSTERGESİ: Yağ genleşme depolu transformatörlerde, depodaki yağ seviyesinin kontrol edilebilmesi için kullanılan bir gösterge olup hermetik tip transformatörlerde de değişik tipte olanları vardır. İstendiğinde kontaklı veya kontaksız olmak üzere seçilebilir. ATS trafo 13 DISTRIBUTION & POWER TRANSFORMERS

OIL IMMERSED, 3 PHASE TRANSFORMERS, WITH CONSERVATOR TANK & HERMETICALLY SEALED TECHNICAL VALUES POWER : HV RATED VOLTAGE : LV RATED VOLTAGE : 25-2500 kva up to 15.8 kv 0.4 kv Rated Power Vector Group No Load Losses Po (Ao) Load Losses (Pk) (Ak) Imp. Voltage Uk No Load Current Io Sound Level Regulation at Full Load Efficiency at Full Load kva 25 50 100 10 250 400 30 800 1000 100 2000 2500 Yzn 11 Yzn 11 Yzn 11 Yzn 11 W 5 90 145 210 300 430 00 50 770 950 1200 1450 1750 W @75 450 750 1700 2350 3250 400 000 700 9500 12000 15000 18500 % 4 4 4 4 4 4 4 % 1.8 1. 1.4 1.3 1.2 1.1 1.0 1.0 0.9 0.9 0.8 0.7 0. db(a) 37 39 41 44 47 50 52 53 55 5 58 0 3 pf = 0.8 3.0 3.45 3.31 3.19 3.12 3.03 2.98 4.2 4.27 4.27 4.2 4.2 4.2 pf = 1.0 1.8 1.57 1.32 1.14 1.02 0.89 0.81 0.93 0.94 0.94 0.93 0.93 0.92 pf = 0.8 97.49 97.94 98.29 98.53 98.9 98.8 98.98 98.97 98.9 98.97 98.98 98.98 99.00 pf = 1.0 97.98 98.35 98.2 98.82 98.95 99.09 99.18 99.18 99.17 99.17 99.18 99.18 99.20 HV RATED VOLTAGE : LV RATED VOLTAGE : up to 33 kv 0.4 kv Rated Power Vector Group No Load Losses Po (Ao) Load Losses (Pk) (Ak) Imp. Voltage Uk No Load Current Io Sound Level Regulation at Full Load Efficiency at Full Load kva 25 50 100 10 250 400 30 800 1000 100 2000 2500 Yzn 11 Yzn 11 Yzn 11 Yzn 11 W 112 10 270 390 550 790 1100 1300 1450 1750 2200 2700 3200 W @75 72 1050 150 2150 3000 4150 5500 7000 8900 11500 14500 18000 22500 % 4.5 4.5 4.5 4.5 4.5 4.5 4.5 % 2.0 1.8 1. 1.5 1.4 1.3 1.2 1.1 1.0 1.0 0.9 0.8 0.7 db(a) 47 50 54 57 0 3 5 7 8 9 71 73 pf = 0.8 4.32 4.09 3.8 3.9 3.0 3.50 3.39 4.35 4.3 4.38 4.37 4.37 4.37 pf = 1.0 2.75 2.18 1.74 1.44 1.29 1.13 0.97 1.05 1.07 1.09 1.08 1.08 1.08 pf = 0.8 9.23 97.0 97. 98.05 98.2 98.48 98.71 98.72 98.72 98.9 98.71 98.72 98.73 pf = 1.0 9.9 97.4 98.12 98.44 98.0 98.78 98.9 98.97 98.98 98.95 98.97 98.98 98.98 NOTE: Technical Dimensions and Weights values given in Table sampling is taken from our production, should be considered as approximate values. Any of the technical information contained in the catalog are not binding, may be changes in the value that there should be bear in mind. www.atstrafo.com

OIL IMMERSED, 3 PHASE TRANSFORMERS, WITH CONSERVATOR TANK & HERMETICALLY SEALED TABLE OF TECHNICAL DIMENSIONS & WEIGHTS POWER : HV RATED VOLTAGE : LV RATED VOLTAGE : 25-2500 kva up to 15.8 kv 0.4 kv Hermetic Type Rated Power Length L Width W Height H Oil Weight Act. Part Weig. Total Weight With Conservator Tank Length L Width W Height H Oil Weight Act. Part Weig. Total Weight kva 25 810 50 990 110 175 390 830 700 120 115 190 415 50 890 845 1090 145 335 80 900 800 1350 10 355 710 100 915 850 1140 170 455 745 920 830 1390 185 480 800 10 1050 900 240 20 1050 1100 880 1500 270 0 1150 250 115 925 120 310 80 1320 80 1525 345 905 140 400 940 1350 390 1020 140 1290 880 1700 435 1130 1730 30 1420 980 1550 540 1380 2200 1580 900 1900 550 1470 2385 800 1540 1110 1700 90 1720 2890 150 1000 2020 740 1820 3140 1000 1580 1200 1710 725 1800 3150 1700 1150 2050 790 1900 3220 100 1290 1750 70 190 3390 1730 1200 2100 815 2020 3450 100 1890 1350 1800 975 2480 4320 2050 1350 210 100 250 4550 2000 2140 1410 1920 1150 2990 5450 2275 1400 2300 1320 3150 5700 2500 2400 1470 2075 1450 3585 550 200 1450 2450 1850 3700 50 HV RATED VOLTAGE : LV RATED VOLTAGE : up to 33 kv 0.4 kv Hermetic Type With Conservator Tank Rated Power Length L Width W Height H Oil Weight Act. Part Weig. TTotal Weight Length L Width W Height H Oil Weight Act. Part Weig. TTotal Weight kva 25 80 80 1185 135 200 420 870 700 1290 125 205 435 50 955 80 1290 215 370 710 90 800 1400 175 380 740 100 975 80 1340 220 495 800 995 850 1450 210 505 845 10 1135 950 1450 320 90 1180 1150 900 150 290 705 1230 250 90 1470 30 920 145 1285 80 1595 375 940 1550 400 1315 990 140 485 110 1900 1350 880 175 490 1185 1930 30 1510 1010 1820 575 1575 2495 175 910 1990 590 100 2525 800 180 1190 1920 70 1920 3210 1790 1050 2100 820 1950 3320 1000 10 1280 1935 70 1985 3340 1800 1140 2130 850 2020 340 1700 1350 1990 795 2100 3580 180 1200 2190 890 2140 390 100 2000 1420 2050 1055 2755 475 2200 1350 220 1150 2810 4810 2000 220 1490 2200 1370 320 5770 2420 1420 2420 1520 3330 080 2500 2550 1550 2350 1950 3875 7050 2750 1480 200 2290 3950 7490 ATS trafo 15

www.atstrafo.com