Luminaire efficiency factor system for general lighting



Similar documents
Outdoor Workplace Lighting according to CIE S 015:2005 / pren

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

Vehicle Circulation Areas - OPT 3 (Rev 00)

DOSSIER EN m CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012

DOE Solid-State Lighting GATEWAY Program. GATEWAY Registry and Demonstration Reporting Template. U.S. Department of Energy November 2008

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

Solid State Lighting Definitions for Functional and Decorative Applications

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial.

T5 LongLast. GE Lighting DATA SHEET

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

Lighting with Artificial Light

Calculation and Presentation of the Standard CIE UGR Table for Indoor Lighting Luminaires

DIALux. evo 1. User Manual. The Software Standard for Calculating Lighting Layouts

THE MAINTENANCE FACTOR FOR LED LIGHTING

Session 15 Lighting Fundamentals

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Progetto 1. DETAS SpA: No. ordine: Dleds Division: No. cliente: Date: Operator: Giorgio Durin

EN :2011. Light and lighting Lighting of workplaces Part 1: Indoor work places. Head of Strategic Lighting Applications

MAGNA PARK Extension. Report. DHL SUPPLY CHAIN: External Lighting Strategy. June

Guide to new, energy-efficient lighting technologies for your business

Video Conference Indirect Wash LED Fixture

Linear Recessed Center Basket Fixture. Lutron

Robust and waterproof

Lighting Requirements

GUIDE TO THE ARTIFICIAL LIGHTING OF HOCKEY PITCHES

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Eco-$mart, Inc. TOLL FREE: (888) FAX: (941)

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

Technical Report An Analysis on the Use of LED Lighting for Video Conferencing

V anguard. applications 5.1. vanguard vanguard. Assembly lines. Production areas. Gymnasia. Swimming pools. Clean areas. Food processing areas

LED PROFI SYSTEM INDOOR PROFI 80 LED LINE PROFI 80 R LED LINE PROFI 48 WLX LED PROFI 60 WLX LED UP/DN PROFI TEC5 OP LED LINE PROFI TEC5 IND LED LINE

A Guide to the Specification of LED Lighting Products 2012

A Guide to Energy Efficient and Cost Effective Lighting

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

nano led THE GREEN LIGHT

Recessed. EvoKit LED Retrofit Kits Gen 3

A Philips Ledalite Chopstick LED Semi-Indirect Luminaire

L.I ENERGY EFFICIENCY STANDARDS AND LABELLING (NON-DUCTED AIR CONDITIONERS AND SELF-BALLASTED FLUORESCENT LAMPS) REGULATIONS, 2005

KATO. LED Lighting High Bay und Low Bay

Luminaire efficiency: what mandatory and voluntary labels achieve, and what they should achieve in the future

EMERGENCY LIGHTING DESIGN GUIDE

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Linear Luminaire with LED Series EXLUX 6402/2

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Product specifications

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Industrial Linergy LED

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

OSRAM DULUX SUPERSTAR MICRO TWIST

Assessments of LEDs IESNA LM-79, LM-80 & LM-82

FUNDAMENTALS OF LIGHTING ADDENDA #1 BUG RATINGS Backlight, Uplight, and Glare (ref. TM-15 and addenda)

Measurement of illuminance in electrically lit spaces

THESIS SUBMITTED AS PART OF THE APPLIED PHYSICS PROGRAM IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF BACHELOR OF SCIENCE IN PHYSICS

Lumination LED Luminaires

The Coming Revolution in Lighting Practice BY SAM BERMAN

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Stow Lighting Advisory Subcommittee Terminology Guide

English version. Road lighting - Part 2: Performance requirements

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Geometry and Measurement

Emergency Lighting Introduction

H45 LED - Direct and indirect pendant

Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light

T5 Watt-Miser Linear Fluorescent lamps

Bridgelux ES Array Series

BSE Geluid en Licht Pagina 1 van 5. Description

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Lighting (Illumination) in Warehouses

LED Tubular Lamp / Kit Guide

AUTOMATED ELECTRICAL INSTALLATION DESIGN USING JAVA SCRIPT PROGRAM

High flux for outdoor applications

Benchmark Report. Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

Lighting Calculations in the LED Era

Installation, operation and maintenance manual TX 35A

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

Operating Lights. marlux with centrixbeam LIGHT OF THE NEXT GENERATION

Flexible LED system approach

ABS 731 Lighting Design & Technology. Spring 2006

TABLE Lighting Power Densities Using the Space-by-Space Method(continued) TABLE Lighting Power Densities Using the Space-by-Space Method

Medical Lighting. XL4 Patient Light

STREET LIGHTING CONSTRUCTION DESIGN CRITERIA

Lutron Linear Recessed and Video Conference Fixture Solutions

Lumination LED Luminaires

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

Lighting Management solutions

Nightscape High performance floodlights and spotlights for discharge lamps

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI

Luminaires V1.2-SSL Directional Luminaire

Features. High Brightness LED Light source

P850 Next Generation LED Luminaire with AeroFlow Cooling System

Transcription:

Luminaire efficiency factor system for general lighting Axel Stockmar LCI Light Consult International D-29227 Celle KEYWORDS general lighting, luminaire efficiency, utilisation factor, European utilisation factor method, European luminaire efficiency labelling system. ABSTRACT Lighting requirements concern the criteria illuminance level, luminance distribution, glare limitation, modelling, colour appearance, and colour rendition. Besides these photometric quality criteria special attention is paid to the costs for acquisition, installation, maintenance, and operation of the illumination. Here it is of particular interest to what extent the total costs could be reduced by utilising lamps with higher efficacy, ballast with lower losses, and luminaires with higher light output ratios and more appropriate luminous intensity distributions. For lamps and ballasts appropriate classification and labelling systems have been developed and are in use throughout Europe. For luminaires there are a number of proposals for energydependent classification and/or labelling procedures, but for various reasons non of the methods has been developed towards a usable system. As luminaires are being designed to fulfil particular needs, it seems to be impossible to create a system which would cover all luminaires. However for luminaires to be used for general lighting of e.g. offices, stores, workshops, sports facilities etc. a luminaire efficiency factor system could be developed based on an utilisation factors. As the utilisation factor is in proportion to the light output ratio and is dependent on the luminaire flux distribution, the luminaire layout, and the reflection properties of a space, it is necessary to define appropriate standard conditions. Concerning the luminous flux distribution there is a need for more than one category, i.e. direct/semidirect, direct/indirect, and semi-indirect/indirect. To keep the system simple there should be only a few standard rooms, but with two luminaire arrangements for ceiling mounted and suspended installations. The reflectances of ceiling and walls should be suitable also for luminaires with considerable upward flux components. Based on a comprehensive European utilisation factor method a luminaire efficiency factor labelling system for general lighting will be discussed. INTRODUCTION Lighting requirements concern the criteria illuminance level, luminance distribution, glare limitation, modelling, colour appearance, and colour rendition. Besides these photometric quality criteria special attention is paid to the costs of acquisition, installation, maintenance, and operation of the illumination. Here it is of particular interest to what extent the total costs could be reduced by utilising lamps with higher efficacy, ballasts with löwer losses, and luminaires with higher light output ratios and/or more appropriate luminous intensity distributions. For lamps and ballasts appropriate classification and labelling systems have been developed and are in use throughout Europe. For luminaires a number of proposals have been emerged for energy-dependent classification or labelling procedures, but none of the ideas has been developed towards an approved system. The need for such a system has been stressed by the European Commission, which has initialised activities to create a mandated European standard. As luminaires are being designed to fulfil particular needs, it seems to be impossible to create a system, which would RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 311

SESSION 12: STANDARDS AND TECHNOLOGY cover all types of luminaires at the same time, such as floodlights, wall washers, and/or road lighting lanterns. However, for luminaires to be used for general lighting of e.g. offices, stores, workshops, sports facilities etc. a luminaire efficiency factor system could be developed based on utilisation factors. At the moment there are several utilisation factor methods being used in Europe showing remarkable differences. A European approach towards a luminaire efficiency factor labelling system requires as a first step a harmonised European utilisation factor method. Lamps, ballasts, and luminaires are usually regarded as independent components having different measures for energy efficiency classifications. But in many cases the combined effect of lamp, ballast, and luminaire type matter, expressed in e.g. system efficacy. If this is specified in addition, it would help to take into account incompatibilities, ambient temperature influences etc. FEASIBILITY STUDIES AND PROPOSALS The ratio of the achievable illumination level, expressed in terms of an average illuminance on a reference surface (usually the utilisation plane), to the necessary electric power depends on the selected lamps, ballasts, and luminaires as well as on the reflectances of all interior surfaces. For lamps and ballasts there are appropriate measures, efficacy and ballast-lamp circuit power respectively, which serve as a basis for energy efficiency labelling systems. However, for luminaires the obvious measure, the light output ratio, is not a suitable quantity, as there exists no relationship to the achievable illumination level. In an early study [1] it was concluded that for general lighting in interiors only a system based on utilisation factors could describe photometric properties while taking into account the necessary electric energy, as the utilisation factor is in proportion to the light output ratio and is dependent on the luminaire flux distribution for given standard conditions. Furthermore it was proposed to consider at the same time the glare limitation, as for some highly effective luminaires the glare could be exceedingly high. When this study has been made public [2] it was felt that the system should be developed further to cover more than one standard room, but without glare considerations. This was regarded not simple enough for a labelling system. In a different proposal [3] the light output ratio was considered as the suitable measure to describe the energy efficiency of luminaires. In building regulations where energy efficiency is expressed in terms of luminaire lumens per circuit watt the light output ratio plays an important role, but it will not describe the lighting performance of the installation. The more recent proposal [4] for the representation of luminaire efficiency factors based on utilisation factors for three standard rooms with room indices k=1.00, k=2.00, and k=5.00 seems to be a logic step towards a luminaire efficiency labelling systems. Unfortunately the envisaged conversion of the room indices into approximate floor plan area sizes is misleading and valid only for ceiling mounted luminaires. The room index depends not only on length and width of the interior but also on the mounting height of the luminaires, i.e. the distance between luminaire plane and reference plane. For a given suspension ratio SR, the ratio of suspension height to mounting plus suspension height, a room index of for example k=5,00 for a suspended luminaire arrangement corresponds with a room index of only 3.5 to 4.0 for a ceiling mounted luminaire arrangement (figure 1) in the same interior, which makes it very difficult to compare different lighting systems. In other words, the floor area leading to the same room index differs by a factor of up to two dependent on the suspension ratio (figure 2). A further problem arises from the fact that there are several utilisation factor methods being used in Europe showing considerable differences. UTILISATION FACTOR METHODS BEING USED IN EUROPE Throughout Europe there are at the moment several methods being used for the calculation of utilisation factors In particular these are the British as described in CIB- SE Technical Memoranda No 5 [5], the German as published in LiTG Publication 3.5 [6], the French as given in the French Norm NF C71-121 [7], the Nordic as part of the NB-Documentation of luminaires [8], and the CIE- Method as specified in Publications No 40 [9] and No 52 [10]. In all utilisation factor methods considered it is assumed that the interiors are empty rectangular parallelepipeds. The working plane is assumed to be materialised by a surface, which will be counted as one of the room surfaces - with reflectance of the floor cavity. All room surfaces (ceiling, walls, and working plane) reflect uniformly and according to Lambert's law. The luminaires are arranged in regular patterns in the luminaire plane at a specified distance above the working plane. The indirect component of the utilisation factors is calculated using the common flux transfer theory. Tabulated transfer factors show virtually no differences whether they have been evaluated for rooms with a square plan or with a rectangular plan (length to width equal to 1.6 to 1). Differences experienced between the different utilisation factor methods are caused by the procedures applied to the calculation of the utilization factors for direct illumination. The important influencing factors are the luminaire layout - described best by the spacing-to-height ratio and the proximity - and the way in which the direct flux onto the working plane is calculated zonal multipliers, stripe multipliers, point-by-point calculation etc. For the standard room with room index k=2.00 the luminaire layouts used in the different utilisation factor methods are shown in figure 3. Similar differences in luminaire arrangements are found for all room indices resulting in considerable differences between the utilisation factors obtained. An example is given in figure 4 for the proposed reflectance combination. Following the proposal for representation of lighting efficiency factors [4] but using the room index instead of the plan area size as parameter leads in consequence to different results applying the different utilisation factor methods (figure 5). The discrepancies are larger for smaller room indices, but also smaller 312 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE

SESSION 12: STANDARDS AND TECHNOLOGY discrepancies for larger room indices could have quite some commercial impact. REQUIREMENTS FOR A LUMINAIRE EFFICIENCY FACTOR LABELLING SYSTEM Utilisation factors for a set of standard rooms seem to be an adequate measure to form the basis for a luminaire efficiency factor labelling system. From the presented results it is obvious that there is still a need for a common European utilisation factor method. A harmonised method should reflect as far as possible current practice. Comparisons have shown that utilisation factors calculated according to the CIE method are somewhere in the middle of the bandwidth of the utilisation factors obtained using the other methods (figure 4) [11]. Therefore a European utilisation factor method should apply the CIE method for the calculation of the utilisation factors for direct illumination. To take advantage of more pronounced luminous intensity distributions the method should allow for luminaire arrangements with different spacing-to-height ratios, preferably between 1.00 and 2.00 in steps of 0.25. For the luminaire efficiency factor system it is proposed to fix the spacing-to-height ratio at 1.00, otherwise it has to be stated every time. In addition to ceiling mounted systems the method should be extended to enable the calculation of utilisation factors for suspended arrangements. This would make it possible to compare different systems regarding luminaire efficiencies. In this case a suspension ratio has to be standardised; a realistic suspension ratio would be _. The standard sets of reflectance combinations should include the one proposed for the representation of luminaire efficiency factors, i.e. 0.70 for ceiling, 0.50 for walls, and 0.20 for the floor cavity, and also a set with higher reflectances for lighting systems with considerable indirect components [12]. CONCLUSIONS Provided a comprehensive European utilisation factor method could be established, calculated utilisation factors for well-defined standard conditions could be used for a luminaire efficiency factor labelling systems. It seems to be necessary to distinguish between ceiling mounted and suspended luminaires to make useful comparisons possible. The borderline between ceiling mounted and suspended luminaires could be set using a downward flux fraction of 0.90. Furthermore, for indirect lighting systems with downward flux fractions smaller than 0.10 it is probably more realistic to use higher than proposed standard reflectances for ceilings and walls. In any case the mounting mode should be stated in the luminaire efficiency factor label and/or the conversion from room index to floor plan area size should reflect the standard suspension ratio. In addition it could be useful to complement the luminaire efficiency factor label with information concerning the luminaire lumens per circuit watt here called the system efficacy which is needed to check conformity with some building regulations as mentioned in an earlier proposal [3]. This could help to identify energy efficient luminaires, which can use only less efficient lamps or ballasts (figure 6). The only problem remaining is the fact that very efficient luminaires could cause considerable glare which will not be notified. Therefore the glare limitation has to be evaluated separately or a glare dependent modifying factor would have to be introduced. BIBLIOGRAPHY [1] Stockmar, A.Evaluation of a Luminaire Specific Index for the Description of Photometric Properties of Interior Luminaires Taking into Account the Efficient Use of Energy, Study on behalf of CELMA, 1994. [2] Stockmar, A.Proposal for a Luminaire Specific Index for the Description of Photometric Properties of Interior Luminaires Taking into Account the Efficient Use of Energy, Proceedings RIGHT LIGHT 4, Volume 2, p. 41-45, 1997. [3] Hampton, B.Conservation of Fuel and Power: Regulations for Energy Efficiency to Protect the Environment An Industry Proposal, CIBSE National Lighting Conference Lancaster,1998. [4] CELMA Proposal for luminaire efficiency factor presentation, CEN TC 169 document N 418, 2001. [5] CIBSE Technical Memoranda 5, The calculation and use of utilisation factors, 1980. [6] LiTG Publikation 3.5, Projektierung von Beleuchtungsanlagen nach dem Wirkungsgradverfahren, 1988. [7] NF C71-121, Méthode simplifiée de prédétermination des éclairement dans les espaces clos et classification correspondante des luminaires, UTE, 1993. [8] NBDOC, A computer program for NB-documentation of luminaires, LTLI Notat 248, 1987. [9] CIE Publication No 40, Calculations for interior Lighting, Basic method, 1978. [10] CIE Publication No 52, Calculations for interior lighting, Applied method, 1982. [11]Stockmar, A.Comparison of Utilisation Factor Methods, CEN TC 169 / WG2 document N184, 2001. [12] Stockmar, A.Proposal for a European Utilisation Factor Method, Proceedings ILUMINAT 2001, paper no. 4, p. 1-4. RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 313

SESSION 12: STANDARDS AND TECHNOLOGY Figure 1: Room Index Dependence for Different Suspension Ratios 314 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE

SESSION 12: STANDARDS AND TECHNOLOGY Figure 2: Floor Area for same Room Index / Different Suspension Ratios RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 315

SESSION 12: STANDARDS AND TECHNOLOGY Figure 3: Different Standard Luminaire Arrangements 316 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE

SESSION 12: STANDARDS AND TECHNOLOGY Figure 4: Comparison of Utilisation Factor Methods RIGHT LIGHT 5, MAY 2002, NICE, FRANCE 317

SESSION 12: STANDARDS AND TECHNOLOGY Figure 5: Comparison of Luminaire Efficiency Factors Figure 6: Luminaire Efficiency Factors 318 RIGHT LIGHT 5, MAY 2002, NICE, FRANCE